Lamp controlgear - Part 2-14: Particular requirements for DC and/or AC supplied electronic controlgear for fluorescent induction lamps

IEC 61347-2-14:2018 specifies particular safety requirements for electronic controlgear for use on AC supplies up to 1 000 V at 50 Hz or 60 Hz and/or DC supplies with operating frequencies deviating from the supply frequency, associated with fluorescent induction lamps as specified in IEC 62532 and IEC 62639, for high-frequency operation.

Geräte für Lampen - Teil 2-14: Besondere Anforderungen an gleich- und/oder wechselstromversorgte elektronische Betriebsgeräte für Induktions-Leuchtstofflampen

Appareillages de lampes - Partie 2-14: Exigences particulières pour les appareillages électroniques alimentés en courant continu et/ou alternatif pour les lampes fluorescentes à induction

L'IEC 61347-2-14:2018 spécifie les exigences particulières de sécurité applicables aux appareillages électroniques destinés à être alimentés en courant alternatif jusqu’à 1 000 V à 50 Hz ou 60 Hz et/ou à courant continu avec des fréquences de fonctionnement différentes de la fréquence du réseau d’alimentation, associés aux lampes fluorescentes à induction spécifiées dans l’IEC 62532 et l’IEC 62639, pour un fonctionnement à haute fréquence.

Krmilne stikalne naprave za sijalke - 2-14. del: Posebne zahteve za enosmerno in/ali izmenično napajane elektronske krmilne stikalne naprave za fluorescenčne indukcijske sijalke (IEC 61347-2-14:2018)

Ta del standarda IEC 61347 določa posebne varnostne zahteve za elektronske krmilne stikalne naprave za uporabo z enosmernim napajanjem do 1000 V pri 50 Hz ali 60 Hz in/ali izmeničnim napajanjem z delovno frekvenco, ki odstopa od napajalne frekvence, v povezavi s fluorescenčnimi indukcijskimi sijalkami, kot so opredeljene v standardih IEC 62532 in IEC 62639, za delovanje pri visokih frekvencah.
Za zasilno razsvetljavo so posebne zahteve za centralno napajane krmilne stikalne naprave so podane v dodatku J. Zahteve glede delovanja za varno delovanje zasilne razsvetljave so prav tako zajete v dodatku J.
Zahteve za necentralno napajane krmilne stikalne naprave za zasilno razsvetljavo so podane v standardu IEC 61347-2-7.
OPOMBA: Zahteve glede delovanja, navedene v dodatku J, so tiste, ki so povezane z varnostjo glede zanesljivega zasilnega delovanja.

General Information

Status
Published
Publication Date
26-Apr-2018
Current Stage
6060 - Document made available
Due Date
27-Apr-2018
Completion Date
27-Apr-2018

Buy Standard

Standard
EN IEC 61347-2-14:2018
English language
39 pages
sale 10% off
Preview
sale 10% off
Preview

e-Library read for
1 day

Standards Content (sample)

SLOVENSKI STANDARD
SIST EN IEC 61347-2-14:2018
01-julij-2018
.UPLOQHVWLNDOQHQDSUDYH]DVLMDONHGHO3RVHEQH]DKWHYH]DHQRVPHUQR
LQDOLL]PHQLþQRQDSDMDQHHOHNWURQVNHNUPLOQHVWLNDOQHQDSUDYH]DIOXRUHVFHQþQH
LQGXNFLMVNHVLMDONH ,(&

Lamp controlgear - Part 2-14: Particular requirements for d.c. and/or a.c. supplied

electronic controlgear for fluorescent induction lamps (IEC 61347-2-14:2018)
Ta slovenski standard je istoveten z: EN IEC 61347-2-14:2018
ICS:
29.130.01 Stikalne in krmilne naprave Switchgear and controlgear
na splošno in general
29.140.99 Drugi standardi v zvezi z Other standards related to
žarnicami lamps
SIST EN IEC 61347-2-14:2018 en

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN IEC 61347-2-14:2018
---------------------- Page: 2 ----------------------
SIST EN IEC 61347-2-14:2018
EUROPEAN STANDARD EN IEC 61347-2-14
NORME EUROPÉENNE
EUROPÄISCHE NORM
April 2018
ICS 29.140.99
English Version
Lamp controlgear - Part 2-14: Particular requirements for DC
and/or AC supplied electronic controlgear for fluorescent
induction lamps
(IEC 61347-2-14:2018)

Appareillages de lampes - Partie 2-14: Exigences Geräte für Lampen - Teil 2-14: Besondere Anforderungen

particulières pour les appareillages électroniques alimentés an gleich- und/oder wechselstromversorgte elektronische

en courant continu et/ou alternatif pour les lampes Betriebsgeräte für Induktions-Leuchtstofflampen

fluorescentes à induction (IEC 61347-2-14:2018)
(IEC 61347-2-14:2018)

This European Standard was approved by CENELEC on 2018-04-03. CENELEC members are bound to comply with the CEN/CENELEC

Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC

Management Centre or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other language made by translation

under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the

same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,

Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,

Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden,

Switzerland, Turkey and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels

© 2018 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.

Ref. No. EN IEC 61347-2-14:2018 E
---------------------- Page: 3 ----------------------
SIST EN IEC 61347-2-14:2018
EN IEC 61347-2-14:2018 (E)
European foreword

The text of document 34C/1374/FDIS, future edition 1 of IEC 61347-2-14, prepared by IEC/SC 34C:

"Auxiliaries for lamps, of IEC technical committee 34: Lamps and related equipment" was submitted to

the IEC-CENELEC parallel vote and approved by CENELEC as EN IEC 61347-2-14:2018.
The following dates are fixed:
(dop) 2019-01-03
• latest date by which the document has to be
implemented at national level by
publication of an identical national
standard or by endorsement
• latest date by which the national (dow) 2021-04-03
standards conflicting with the
document have to be withdrawn

Attention is drawn to the possibility that some of the elements of this document may be the subject of

patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.

Endorsement notice

The text of the International Standard IEC 61347-2-14:2018 was approved by CENELEC as a

European Standard without any modification.

In the official version, for Bibliography, the following note has to be added for the standard indicated:

IEC 60598-2-22 NOTE Harmonized as EN 60598-2-22.
---------------------- Page: 4 ----------------------
SIST EN IEC 61347-2-14:2018
EN IEC 61347-2-14:2018 (E)
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications

The following documents are referred to in the text in such a way that some or all of their content

constitutes requirements of this document. For dated references, only the edition cited applies. For

undated references, the latest edition of the referenced document (including any amendments)

applies.

NOTE 1 Where an International Publication has been modified by common modifications, indicated by (mod), the relevant

EN/HD applies.

NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here:

www.cenelec.eu.
Publication Year Title EN/HD Year
IEC 60929 2011 AC and/or DC-supplied electronic control EN 60929 2011
gear for tubular fluorescent lamps -
Performance requirements
- - + AC 2011
IEC 61347-1 2015 Lamp controlgear - Part 1: General and EN 61347-1 2015
safety requirement
+ A1 2017 + A1 2018
IEC 61347-2-7 2011 Lamp controlgear -- Part 2-7: Particular EN 61347-2-7 2012
requirements for battery supplied electronic
controlgear for emergency lighting (self-
contained)
+ A1 2017 - -
IEC 61547 - Equipment for general lighting purposes - EN 61547 -
EMC immunity requirements
IEC 62532 2011 Fluorescent induction lamps - Safety EN 62532 2011
specifications
IEC 62639 2012 Fluorescent induction lamps - Performance EN 62639 2012
specification
---------------------- Page: 5 ----------------------
SIST EN IEC 61347-2-14:2018
---------------------- Page: 6 ----------------------
SIST EN IEC 61347-2-14:2018
IEC 61347-2-14
Edition 1.0 2018-02
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Lamp controlgear –
Part 2-14: Particular requirements for DC and/or AC supplied electronic
controlgear for fluorescent induction lamps
Appareillages de lampes –
Partie 2-14: Exigences particulières pour les appareillages électroniques
alimentés en courant continu et/ou alternatif pour les lampes fluorescentes à
induction
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 29.140.99 ISBN 978-2-8322-5448-6

Warning! Make sure that you obtained this publication from an authorized distributor.

Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.

® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale
---------------------- Page: 7 ----------------------
SIST EN IEC 61347-2-14:2018
– 2 – IEC 61347-2-14:2018 © IEC 2018
CONTENTS

FOREWORD ........................................................................................................................... 4

INTRODUCTION ..................................................................................................................... 6

1 Scope .............................................................................................................................. 7

2 Normative references ...................................................................................................... 7

3 Terms and definitions ...................................................................................................... 7

4 General requirements ...................................................................................................... 9

5 General notes on tests .................................................................................................... 9

6 Classification ................................................................................................................... 9

7 Marking ........................................................................................................................... 9

7.1 General ................................................................................................................... 9

7.2 Mandatory markings ................................................................................................ 9

7.3 Information to be provided, if applicable ................................................................ 10

8 Protection against accidental contact with live parts ...................................................... 10

9 Terminals ...................................................................................................................... 10

10 Provisions for earthing ................................................................................................... 10

11 Moisture resistance and insulation ................................................................................. 10

12 Electric strength ............................................................................................................ 10

13 Thermal endurance test for windings ............................................................................. 10

14 Fault conditions ............................................................................................................. 10

15 Protection of associated components............................................................................. 11

15.1 Maximum peak voltage under normal operation conditions .................................... 11

15.2 Maximum working voltage under normal and abnormal operating conditions ......... 11

15.3 Compliance ........................................................................................................... 11

15.4 Insulation of input terminals of controllable electronic controlgear ......................... 11

16 Abnormal conditions ...................................................................................................... 12

16.1 Abnormal conditions for DC and/or AC supplied electronic controlgear ................. 12

16.2 Additional abnormal conditions for DC only electronic controlgear ........................ 12

17 Construction .................................................................................................................. 12

18 Creepage distances and clearances .............................................................................. 12

19 Screws, current-carrying parts and connections ............................................................. 12

20 Resistance to heat, fire and tracking .............................................................................. 13

21 Resistance to corrosion ................................................................................................. 13

Annex A (normative) Test to establish whether a conductive part is a live part which

may cause an electric shock ................................................................................................. 14

Annex B (normative) Particular requirements for thermally protected lamp controlgear ........ 15

Annex C (normative) Particular requirements for electronic lamp controlgear with

means of protection against overheating ............................................................................... 16

Annex D (normative) Requirements for carrying out the heating tests of thermally

protected lamp controlgear ................................................................................................... 17

Annex E (normative) Use of constant S other than 4 500 in t tests ..................................... 18

Annex F (normative) Draught-proof enclosure ...................................................................... 19

Annex G (normative) Explanation of the derivation of the values of pulse voltages .............. 20

Annex H (normative) Tests................................................................................................... 21

---------------------- Page: 8 ----------------------
SIST EN IEC 61347-2-14:2018
IEC 61347-2-14:2018 © IEC 2018 – 3 –

Annex I (normative) Additional requirements for built-in magnetic ballast with double

or reinforced insulation ......................................................................................................... 22

Annex J (normative) Particular additional safety requirements for DC and/or AC

supplied electronic controlgear for emergency lighting .......................................................... 23

J.1 General ................................................................................................................. 23

J.2 Marking ................................................................................................................. 23

J.2.1 Mandatory markings ...................................................................................... 23

J.2.2 Information to be provided if applicable ......................................................... 23

J.3 General statement ................................................................................................ 23

J.4 Starting conditions ................................................................................................ 24

J.5 Operating conditions ............................................................................................. 24

J.6 Current ................................................................................................................. 24

J.7 EMC immunity....................................................................................................... 24

J.8 Pulse voltage from central battery systems ........................................................... 24

J.9 Tests for abnormal conditions ............................................................................... 24

J.10 Temperature cycling test and endurance test ........................................................ 25

J.11 Functional safety (EBLF) ....................................................................................... 25

Annex K (informative) Conformity testing during manufacture .............................................. 26

Annex L (normative) Particular additional requirements for controlgear providing SELV ....... 27

Annex M (informative) Dielectric strength test voltages for controlgear intended for

the use in impulse withstand Category III .............................................................................. 28

Annex N (normative) Requirements for insulation materials used for double or

reinforced insulation ............................................................................................................. 29

Annex O (normative) Additional requirements for built-in electronic controlgear with

double or reinforced insulation .............................................................................................. 30

Annex P (normative) Creepage distances and clearances and distance through

insulation (DTI) for lamp controlgear which are protected against pollution by the use

of coating or potting .............................................................................................................. 31

Annex Q (informative) Example for U calculation ............................................................... 32

Annex R (informative) Concept of creepage distances and clearances ................................. 33

Annex S (informative) Examples of controlgear insulation coordination ................................ 34

Annex T (informative) Creepage distances and clearances for controlgear with a

higher degree of availability (impulse withstand category III) ................................................. 35

Bibliography .......................................................................................................................... 36

Table 1 – Relation between RMS working voltage and maximum peak voltage ..................... 11

Table J.1 – Pulse voltages .................................................................................................... 24

---------------------- Page: 9 ----------------------
SIST EN IEC 61347-2-14:2018
– 4 – IEC 61347-2-14:2018 © IEC 2018
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
LAMP CONTROLGEAR –
Part 2-14: Particular requirements for DC and/or AC supplied
electronic controlgear for fluorescent induction lamps
FOREWORD

1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising

all national electrotechnical committees (IEC National Committees). The object of IEC is to promote

international co-operation on all questions concerning standardization in the electrical and electronic fields. To

this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,

Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC

Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested

in the subject dealt with may participate in this preparatory work. International, governmental and non-

governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely

with the International Organization for Standardization (ISO) in accordance with conditions determined by

agreement between the two organizations.

2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international

consensus of opinion on the relevant subjects since each technical committee has representation from all

interested IEC National Committees.

3) IEC Publications have the form of recommendations for international use and are accepted by IEC National

Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC

Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any

misinterpretation by any end user.

4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications

transparently to the maximum extent possible in their national and regional publications. Any divergence

between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in

the latter.

5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity

assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any

services carried out by independent certification bodies.

6) All users should ensure that they have the latest edition of this publication.

7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and

members of its technical committees and IEC National Committees for any personal injury, property damage or

other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and

expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC

Publications.

8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is

indispensable for the correct application of this publication.

9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of

patent rights. IEC shall not be held responsible for identifying any or all such patent rights.

International Standard IEC 61347-2-14 has been prepared by subcommittee 34C: Auxiliaries

for lamps, of IEC technical committee 34: Lamps and related equipment.
The text of this International Standard is based on the following documents:
FDIS Report on voting
34C/1374/FDIS 34C/1383/RVD

Full information on the voting for the approval of this International Standard can be found in

the report on voting indicated in the above table.

This document has been drafted in accordance with the ISO/IEC Directives, Part 2.

---------------------- Page: 10 ----------------------
SIST EN IEC 61347-2-14:2018
IEC 61347-2-14:2018 © IEC 2018 – 5 –
This document is to be used in conjunction with IEC 61347-1:2015 and
IEC 61347-1:2015/AMD1:2017.
NOTE In this document, the following print types are used:
– Requirements proper: in roman type.
– Test specifications: in italic type.
– Explanatory matter: in smaller roman type.

A list of all parts in the IEC 61347 series, published under the general title Lamp controlgear,

can be found on the IEC website.

The committee has decided that the contents of this document will remain unchanged until the

stability date indicated on the IEC website under "http://webstore.iec.ch" in the data related to

the specific document. At this date, the document will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
---------------------- Page: 11 ----------------------
SIST EN IEC 61347-2-14:2018
– 6 – IEC 61347-2-14:2018 © IEC 2018
INTRODUCTION

This document specifies requirements for fluorescent induction lamp controlgear. The

formatting of IEC 61347-2 into separately published parts provides for ease of future

amendments and revisions. Additional requirements will be added as and when a need for

them is recognized.

This document, and the parts which make up IEC 61347-2, in referring to any of the clauses

of IEC 61347-1, specify the extent to which such a clause is applicable and the order in which

the tests are to be performed; they also include additional requirements, as necessary. All

parts which make up IEC 61347-2 are intended to be self-contained and, therefore, do not

include references to each other. However, for the case of emergency lighting lamp

controlgear, some cross-referencing has been used.

Where the requirements of any of the clauses of IEC 61347-1 are referred to in this document

by the phrase ”The requirements of clause n of IEC 61347-1 apply”, this phrase is interpreted

as meaning that all requirements of the clause in question of Part 1 apply, except any which

are clearly inapplicable to the specific type of lamp controlgear covered by this particular part

of IEC 61347-2.
---------------------- Page: 12 ----------------------
SIST EN IEC 61347-2-14:2018
IEC 61347-2-14:2018 © IEC 2018 – 7 –
LAMP CONTROLGEAR –
Part 2-14: Particular requirements for DC and/or AC supplied
electronic controlgear for fluorescent induction lamps
1 Scope

This part of IEC 61347 specifies particular safety requirements for electronic controlgear for

use on AC supplies up to 1 000 V at 50 Hz or 60 Hz and/or DC supplies with operating

frequencies deviating from the supply frequency, associated with fluorescent induction lamps

as specified in IEC 62532 and IEC 62639, for high-frequency operation.

For emergency lighting operation, particular requirements for controlgear operated from a

central supply are given in Annex J. Performance requirements appropriate to the safe

operation of emergency lighting are also contained in Annex J.

Requirements for emergency lighting controlgear operating from non-centralized power

supplies are given in IEC 61347-2-7.

NOTE Performance requirements detailed in Annex J are those considered to be safety related with respect to

reliable emergency operation.
2 Normative references

The following documents are referred to in the text in such a way that some or all of their

content constitutes requirements of this document. For dated references, only the edition

cited applies. For undated references, the latest edition of the referenced document (including

any amendments) applies.

IEC 60929:2011, AC and/or DC-supplied electronic control gear for tubular fluorescent lamps

– Performance requirements
IEC 61347-1:2015, Lamp controlgear – Part 1: General and safety requirements
IEC 61347-1:2015/AMD1:2017

IEC 61347-2-7:2011, Lamp controlgear – Part 2-7: Particular requirements for battery

supplied electronic controlgear for emergency lighting (self-contained)
IEC 61347-2-7:2011/AMD1:2017
IEC 61547, Equipment for general lighting purposes – EMC immunity requirements
IEC 62532:2011, Fluorescent induction lamps – Safety specifications
IEC 62639:2012, Fluorescent induction lamps – Performance specification
3 Terms and definitions

For the purposes of this document, the terms and definitions given in IEC 61347-1, IEC 62532

and IEC 62639 and the following apply.
---------------------- Page: 13 ----------------------
SIST EN IEC 61347-2-14:2018
– 8 – IEC 61347-2-14:2018 © IEC 2018

ISO and IEC maintain terminological databases for use in standardization at the following

addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.org/obp
3.1
DC and/or AC supplied electronic controlgear

mains/battery-supplied DC only, AC/DC or AC only to AC invertor including stabilizing

elements for starting and operating one or more fluorescent induction lamps, generally at high

frequency
3.2
maximum allowed peak voltage

highest permitted peak voltage across any insulation under open-circuit condition and any

normal and abnormal operating conditions

Note 1 to entry: The maximum peak voltage is related to the declared RMS working voltage (see Table 1).

3.3
emergency lighting
lighting provided for use when the supply to the normal lighting fails

Note 1 to entry: Emergency lighting includes escape lighting and standby lighting.

3.4
rated battery voltage
voltage declared by the battery manufacturer
3.5
rated emergency power supply voltage
rated voltage of the emergency power supply claimed by the manufacturer
3.6
starting aid
device which facilitates the starting of the lamp

Note 1 to entry: A conductive strip affixed to the outer surface of the lamp and a conductive plate which is spaced

within an appropriate distance from a lamp are examples of starting aids.
3.7
ballast lumen factor

ratio of the luminous flux of a reference lamp when the controlgear under test is operated at

its rated voltage and frequency compared with the luminous flux of the same lamp operated

with the appropriate reference ballast supplied at its rated voltage and frequency

3.8
emergency ballast lumen factor
EBLF

ratio of the emergency luminous flux of the lamp supplied by the emergency controlgear to the

luminous flux of the same lamp operated with the appropriate reference ballast at its rated

voltage and frequency
Note 1 to entry: This note only applies to the French language.
3.9
total circuit power

total power dissipated by ballast and lamp in combination, at the rated voltage and frequency

of the ballast
---------------------- Page: 14 ----------------------
SIST EN IEC 61347-2-14:2018
IEC 61347-2-14:2018 © IEC 2018 – 9 –
3.10
reference lamp

lamp selected for testing controlgear which, when associated with a reference ballast, has

electrical characteristics which are close to the rated values as stated in the relevant lamp

standard
Note 1 to entry Relevant starting lamp data sheets are contained in IEC 62639.

[SOURCE: IEC 61347-1:2015, 3.3, modified – "ballasts" has been replaced with "controlgear"

and the note has been added.]
4 General requirements

The requirements of IEC 61347-1:2015 and IEC 61347-1:2015/AMD1:2017, Clause 4 apply,

together with the following additional requirement:

DC and/or AC supplied electronic controlgear for emergency lighting shall comply with the

requirements of Annex J.
5 General notes on tests

The requirements of IEC 61347-1:2015 and IEC 61347-1:2015/AMD1:2017, Clause 5 apply

together with the following additional requirement with regard to the number of specimens.

The following number of specimens shall be submitted for testing:
– one unit for the tests of Clauses 6 to 12 and 15 to 21;

– one unit for the test of Clause 14 (additional units or components, where necessary, may

be required in consultation with the manufacturer).

Tests to meet the safety requirements for DC and/or AC supplied electronic controlgear for

emergency lighting are made under the conditions specified in Annex J.
6 Classification

The requirements of IEC 61347-1:2015 and IEC 61347-1:2015/AMD1:2017, Clause 6 apply.

7 Marking
7.1 General
Controlgear which forms an integral part of the luminaire need not be marked.
7.2 Mandatory markings

In accordance with the requirements of IEC 61347-1:2015 and IEC 61347-1:2015/AMD1:2017,

7.2, controlgear, other than integral controlgear, shall be clearly and durably marked with the

following mandatory markings:

a) items a), b), c), d), e), k) and l) of IEC 61347-1:2015 and IEC 61347-1:2015/AMD1:2017,

7.1, together with
b) the symbol for earthing, as applicable;
c) for controllable controlgear, the control terminals shall be identified;
d) a declaration of the maximum working voltage (RMS) according to 15.3 between
– output terminals,
– any output terminal and earth.
---------------------- Page: 15 ----------------------
SIST EN IEC 61347-2-14:2018
– 10 – IEC 61347-2-14:2018 © IEC 2018
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.