Power line communication apparatus and systems used in low-voltage installations in the frequency range 1,6 MHz to 30 MHz - Part 2-1: Residential, commercial and industrial environment - Immunity requirements

This standard applies to electrical equipment using signals in the frequency range 1,6 MHz to 30 MHz to transmit information on low voltage electrical systems, either on the public supply system or within installations in consumers’ premises. It does not specify the signal modulation methods nor the coding methods nor functional features. Environmental requirements and tests are not included. The immunity requirements have been selected so as to ensure an adequate level of immunity for apparatus at residential, commercial and light industrial premises (Class 1 environment), and industrial premises supplied from a dedicated HV/MV or MV/LV transformers (Class 2 environment). The severity levels required by this standard may not cover extreme cases which may occur in any location but with a low probability of occurrence. In special cases situations will arise where the level of disturbances may exceed the levels specified in this standard (e.g. where a hand-held transmitter is used in proximity to an apparatus). In these instances special mitigation measures may be required.

Kommunikationsgeräte und -systeme auf elektrischen Niederspannungsnetzen im Frequenzbereich 1,6 MHz bis 30 MHz - Teil 2-1: Für den Gebrauch in Wohnbereichen, Geschäfts- und Gewerbebereichen sowie in Kleinbetrieben und in industriellen Räumlichkeiten - Störfestigkeitsanforderungen

Diese Norm gilt für elektrische Betriebsmittel, die Signale im Frequenzbereich 1,6 MHz bis 30 MHz nutzen, um Informationen auf elektrischen Niederspannungsnetzen in öffentlichen Versorgungssystemen oder in Kundenanlagen zu übertragen. Sie beschreibt weder Modulationsarten noch Kodierungsmethoden noch funktionale Merkmale. Umgebungs-anforderungen und Prüfungen sind nicht enthalten. Die Störfestigkeitsanforderungen wurden so ausgewählt, um einen hinreichenden Grad an Störfestigkeit für Geräte im Wohnbereich, Geschäfts- und Gewerbebereich sowie Kleinbetrieben (Klasse 1 Umgebung) und in industriellen Räumlichkeiten, die über einen eigenen HV/MV oder MV/LV Transformator versorgt sind (Klasse 2 Umgebung) sicherzustellen. Die Schärfegrade, die nach dieser Norm gefordert sind, decken jedoch nicht extreme Fälle ab, die in manchen Einsatzorten mit einer sehr geringen Wahrscheinlichkeit auftreten können. In besonderen Fällen wird es Situationen geben, wo die Störgröße den in dieser Norm aufgeführten Wert überschreiten kann, z. B. wo ein Sprechfunkgerät in der Nähe eines Gerätes betrieben wird. In diesen besonderen Fällen können spezielle Abhilfemaßnahmen erforderlich werden.

Equipements et systèmes de communication par courants porteurs utilisés dans les installations à basse tension dans la gamme de fréquences de 1,6 MHz à 30 MHz - Partie 2-1: Environnement résidentiel, commercial et de l'industrie légère - Exigences d'immunité

Cette norme s'applique aux équipements électriques utilisant des signaux dans la gamme de fréquence de 1,6 MHz à 30 MHz pour transmettre l'information sur les réseaux électriques à basse tension, soit sur le réseau d'alimentation public, ou dans des installations privatives. Elle ne spécifie pas les méthodes de modulation du signal ni les méthodes de codage, ni les dispositions fonctionnelles. Les exigences environnementales et les essais ne sont pas inclus. Les exigences d'immunité ont été sélectionnées afin d'assurée un niveau adéquat d'immunité pour les appareils dans des installations résidentielles, commerciales ou de l'industrie légère (environnements de classe 1), et les installations industrielles alimentées par des transformateurs dédiés HT/MT ou MT/BT (environnement de classe 2) Les niveaux de sévérité requis par la présente norme ne couvrent pas les cas extrêmes qui peuvent apparaître mais avec une très faible probabilité. Dans des cas spéciaux, des situations peuvent apparaître dans lesquelles des niveaux de perturbation peuvent dépasser les niveaux d’essai spécifiés dans la présente norme, (par exemple lorsqu’un émetteur portatif est utilisé à proximité d’un appareil). Dans ces cas particuliers, des mesures spécifiques de réductions peuvent s'avérer nécessaires.

Komunikacijske naprave in sistemi elektroenergetskih vodov za nizkonapetostne inštalacije v frekvenčnem območju 1,6 MHz do 30 MHz – 2-1. del: Stanovanja, poslovni prostori in industrijska okolja – Zahteve za odpornost

General Information

Status
Published
Publication Date
28-Sep-2005
Withdrawal Date
31-Mar-2008
Current Stage
9093 - Decision to confirm - Review Enquiry
Completion Date
02-Mar-2022

Buy Standard

Standard
EN 50412-2-1:2006
English language
18 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-januar-2006
.RPXQLNDFLMVNHQDSUDYHLQVLVWHPLHOHNWURHQHUJHWVNLKYRGRY]DQL]NRQDSHWRVWQH
LQãWDODFLMHYIUHNYHQþQHPREPRþMX0+]GR0+]±GHO6WDQRYDQMD
SRVORYQLSURVWRULLQLQGXVWULMVNDRNROMD±=DKWHYH]DRGSRUQRVW
Power line communication apparatus and systems used in low-voltage installations in the
frequency range 1,6 MHz to 30 MHz -- Part 2-1: Residential, commercial and industrial
environment - Immunity requirements
Kommunikationsgeräte und -systeme auf elektrischen Niederspannungsnetzen im
Frequenzbereich 1,6 MHz bis 30 MHz -- Teil 2-1: Für den Gebrauch in Wohnbereichen,
Geschäfts- und Gewerbebereichen sowie in Kleinbetrieben und in industriellen
Räumlichkeiten - Störfestigkeitsanforderungen
Equipements et systèmes de communication par courants porteurs utilisés dans les
installations à basse tension dans la gamme de fréquences de 1,6 MHz à 20 MHz --
Partie 2-1: Environnement résidentiel, commercial et de l'industrie légère - Exigences
d'immunité
Ta slovenski standard je istoveten z: EN 50412-2-1:2005
ICS:
33.040.60 Telekomunikacije po Powerline
elektroenergetskih vodih telecommunications
91.140.50 Sistemi za oskrbo z elektriko Electricity supply systems
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN 50412-2-1
NORME EUROPÉENNE
EUROPÄISCHE NORM September 2005

ICS 33.120.20; 97.120
English version
Power line communication apparatus and systems
used in low-voltage installations
in the frequency range 1,6 MHz to 30 MHz
Part 2-1: Residential, commercial and industrial environment –
Immunity requirements
Equipements et systèmes de Kommunikationsgeräte und -systeme
communication par courants porteurs auf elektrischen Niederspannungsnetzen
utilisés dans les installations im Frequenzbereich 1,6 MHz bis 30 MHz
à basse tension dans la gamme de Teil 2-1: Für den Gebrauch in
fréquences de 1,6 MHz à 20 MHz Wohnbereichen, Geschäfts- und
Partie 2-1: Environnement résidentiel, Gewerbebereichen sowie in
commercial et de l'industrie légère – Kleinbetrieben und in industriellen
Exigences d'immunité Räumlichkeiten –
Störfestigkeitsanforderungen
This European Standard was approved by CENELEC on 2005-04-12. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and
notified to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden,
Switzerland and United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels

© 2005 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.

Ref. No. EN 50412-2-1:2005 E
Contents
Page
Foreword .3
1 Scope .4
2 Normative references.4
3 Definitions and abbreviations .5
3.1 Definitions .5
3.2 Abbreviations .6
4 Objective .7
5 Description of locations .7
6 Conditions during testing.7
7 Performance criteria.8
8 Narrow band responses & radio-frequency continuous conducted tests.8
8.1 Tests on narrow band devices.8
8.2 Tests on broad band devices.9
9 Product documentation .9
10 Applicability .9
Annex ZZ (informative) Coverage of Essential Requirements of EC Directives.18

Figure 1 - Description of ports .5

Table 1 - Enclosure port - Class 1 environment.10
Table 2 - Enclosure port - Class 2 environment.10
Table 3 - AC / Powerline port - Class 1 environment .11
Table 4 - AC / Powerline port - Class 2 environment .12
Table 5 - DC input and output power ports - Class 1 environment .13
Table 6 - DC input and output power ports - Class 2 environment .14
Table 7 - Ports for signal and control Lines - Class 1 environment.15
Table 8 - Ports for signal and control Lines - Class 2 environment.16
Table 9 - Functional earth ports - Class 2 environment .17

– 3 – EN 50412-2-1:2005
Foreword
This European Standard was prepared by SC 205A, Mains communicating systems, of Technical
Committee CENELEC TC 205, Home and Building Electronic Systems (HBES).
The text of the draft was submitted to the Unique Acceptance Procedure and was approved by
CENELEC as EN 50412-2-1 on 2005-04-12.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2006-04-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2008-04-01
This European Standard has been prepared under a mandate given to CENELEC by the European
Commission and the European Free Trade Association and covers essential requirements of
EC Directive 89/336/EEC. See Annex ZZ.
__________
1 Scope
This standard applies to electrical equipment using signals in the frequency range 1,6 MHz to 30 MHz
to transmit information on low voltage electrical systems, either on the public supply system or within
installations in consumers’ premises.
It does not specify the signal modulation methods nor the coding methods nor functional features.
Environmental requirements and tests are not included.
The immunity requirements have been selected so as to ensure an adequate level of immunity for
apparatus at residential, commercial and light industrial premises (Class 1 environment), and industrial
premises supplied from a dedicated HV/MV or MV/LV transformers (Class 2 environment).
The severity levels required by this standard may not cover extreme cases which may occur in any
location but with a low probability of occurrence. In special cases situations will arise where the level
of disturbances may exceed the levels specified in this standard (e.g. where a hand-held transmitter is
used in proximity to an apparatus). In these instances special mitigation measures may be required.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
When the international publication has been modified by CENELEC common modifications indicated
by (mod), the relevant EN/HD applies.
Title EN/HD
IEC
Publication
IEC 60050-161 International Electrotechnical Vocabulary – Chapter 161: -
Electromagnetic compatibility
IEC 61000-4-2 Electromagnetic compatibility – Part 4-2: Testing and EN 61000-4-2
measurement techniques – Section 2: Electrostatic discharge
immunity test
IEC 61000-4-3 Electromagnetic compatibility (EMC) – Part 4-3: Testing and EN 61000-4-3
measurement techniques – Radiated, radio-frequency
electromagnetic field, immunity test
IEC 61000-4-4 Electromagnetic compatibility (EMC) – Part 4-4: Testing and EN 61000-4-4
measurement techniques – Electrical fast/transient burst
immunity test
IEC 61000-4-5 Electromagnetic compatibility (EMC) – Part 4-5: Testing and EN 61000-4-5
measurement techniques – Surge immunity test
IEC 61000-4-6 Electromagnetic compatibility (EMC) – Part 4-6: Testing and EN 61000-4-6
measurement techniques – Conducted disturbances induced
by radio-frequency fields – Immunity test

– 5 – EN 50412-2-1:2005
IEC 61000-4-8 Electromagnetic compatibility (EMC) – Part 4-8: Testing and EN 61000-4-8
measurement techniques – Power-frequency magnetic field
immunity test
IEC 61000-4-11 Electromagnetic compatibility (EMC) – Part 4-11: Testing and EN 61000-4-11
measurement techniques – Voltage dips, short interruptions
and voltage variations immunity test
IEC 61000-6-1 Electromagnetic compatibility (EMC) – Part 6-1: Generic EN 61000-6-1
standards – Immunity for residential, commercial and light-
industrial environments
IEC 61000-6-2 Electromagnetic compatibility (EMC) – Part 6-2: Generic EN 61000-6-2
standards – Immunity for industrial environments
3 Definitions and abbreviations
3.1 Definitions
Definitions related to EMC and to relevant phenomena may be found in the EC Council Directives, in
chapter 161 of the IEV (IEC 60050) and in IEC and CISPR publications. The definitions stated in EC
Council Directive 89/336/EEC on the approximation of the laws of the Member States relating to
Electromagnetic Compatibility take precedence. The following particular definitions are used in this
standard.
3.1.1
port
particular interface of the specified apparatus with the external electromagnetic environment (see
Figure 1)
EncEnclloossurure pore portt
SiSignal porgnal portt ACAC po powerwer//powerpowerlliinene porportt
PowPoweerr Li Linene
CoCommmmununiiccaattionsions Devic Devicee
DC powDC powerer por portt FFunctiunctional earonal earth poth porrtt

Figure 1 - Description of ports
3.1.2
degradation
the unwanted change in operational performance of a EUT due to electromagnetic disturbances. This
does not necessarily mean malfunction or catastrophic failure
3.1.3
enclosure port
the physical boundary of the equipment through which electromagnetic fields may radiate or impinge.
For plug in units, the physical boundary will by the host unit.
3.1.4
cable port
a point at which a conductor or a cable is connected to the equipment

3.1.5
functional earth port
cable port other than signal or power port, intended for connection to earth for purposes other than
electrical safety
3.1.6
AC power/powerline port
point at which a cable for the a.c. power supply is connected to the equipment / point of connection for
the powerline communications device
3.1.7
signal port
any signal connection other than the communications interface between the powerline
communications device and the AC powerline
3.1.8
public mains network
electricity lines to which all categories of consumers have access and which are operated by a supply
or distribution undertaking for the purpose of supplying electrical energy
3.1.9
class 1 environment
residential, commercial and light industrial locations
3.1.10
class 2 environment
industrial locations
3.1.11
type 1 equipment
a special class for equipment defined by the manufacturer as high integrity and able to operate entirely
without manual intervention, for example: Head-end equipment in HV/MV or MV/LV transformer
substations
3.1.12
type 2 equipment
all equipment other than that classed as Type 1
3.2 Abbreviations
EUT Equipment under test
HV high voltage
ISM industrial, scientific and medical
LV low voltage
MV medium voltage
OFDM Orthogonal Frequency Division Multiplexing

– 7 – EN 50412-2-1:2005
4 Objective
The objective of this standard is to define the immunity test requirements for apparatus defined in the
scope in relation to continuous and transient, conducted and radiated disturbances including
electrostatic discharge.
Test requirements are specified for each port considered
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.