EN 60728-3:2011
(Main)Cable networks for television signals, sound signals and interactive services - Part 3: Active wideband equipment for cable networks
Cable networks for television signals, sound signals and interactive services - Part 3: Active wideband equipment for cable networks
IEC 60728-3:2010(E) lays down the measuring methods, performance requirements and data publication requirements for active wideband equipment of cable networks for television signals, sound signals and interactive services. It covers the frequency range 5 MHz to 3 000 MHz; applies to all broadband amplifiers used in cable networks; lays down the basic methods of measurement of the operational characteristics of the active equipment in order to assess the performance of this equipment; identifies the performance specifications to be published by the manufacturers; states the minimum performance requirements of certain parameters. This fourth edition cancels and replaces the third edition published in 2005 of which it constitutes a technical revision. It includes the following significant technical changes with respect to the previous edition: extension of upper frequency range limit for cable network equipment from 862 MHz to 1 000 MHz; method of measurement and requirements for immunity to surge voltages; extension of scope to equipment using symmetrical ports; additional normative references; additional terms and definitions and abbreviations.
Kabelnetze für Fernsehsignale, Tonsignale und interaktive Dienste - Teil 3: Aktive Breitbandgeräte für Kabelnetze
Réseaux de distribution par câbles pour signaux de télévision, signaux de radiodiffusion sonore et services interactifs - Partie 3: Matériel actif à large bande pour réseaux de distribution par câbles
La CEI 60728-3:2010 présente les méthodes de mesure, les exigences de performance et les exigences de publication des données caractéristiques des matériels actifs à large bande des réseaux de distribution par câbles pour signaux de télévision, signaux de radiodiffusion sonore et services interactifs. Cette quatrième édition annule et remplace la troisième édition parue en 2005, dont elle constitue une révision technique. Elle contient les modifications techniques significatives suivantes par rapport à l'édition précédente: - extension de la limite supérieure de la gamme de fréquences pour les matériels de réseaux de distribution par câbles de 862 MHz à 1 000 MHz; - méthode de mesure et exigences pour l'immunité aux tensions de choc; - extension du domaine d'application aux matériels à accès symétriques; - références normatives supplémentaires; - termes, définitions et abréviations supplémentaires. La version française de cette norme n'a pas été soumise au vote.
Kabelska omrežja za televizijske in zvokovne signale ter interaktivne storitve - 3. del: Aktivna širokopasovna oprema za koaksialna kabelska omrežja (IEC 60728-3:2010)
Ta del IEC 60728 predpisuje metode merjenja, zahteve za zmogljivost in zahteve za objave podatkov za aktivno širokopasovno opremo koaksialnih kabelskih omrežij za televizijske signale, zvočne signale in interaktivne storitve. Ta standard: – velja za vse širokopasovne ojačevalce, ki se uporabljajo v koaksialnih kabelskih omrežjih; – zajema frekvenčni razpon od 5 MHz do 3000 MHz; – velja za enosmerno in dvosmerno opremo; – podaja osnovne metode merjenja značilnosti delovanja aktivne opreme za ocenitev zmogljivosti te opreme; – določa specifikacije za zmogljivost, ki jih morajo objaviti proizvajalci; – navaja minimalne zahteve za delovanje nekaterih parametrov. Ojačevalniki so razdeljeni na naslednji dve ravni kakovosti: razred 1: ojačevalniki, običajno namenjeni postavitvi v kaskadi; razred 2: ojačevalniki, običajno uporabljeni v stanovanjskih blokih ali posameznem stanovanju, ki napajajo nekaj izhodov. Praktične izkušnje so pokazale, da ti tipi izpolnjujejo večino tehničnih zahtev, potrebnih za zagotavljanje minimalne kakovosti signala naročnikom. Ta klasifikacija ne predstavlja zahteve, temveč je namenjena uporabnikom in proizvajalcem kot informacija o kriterijih minimalne kakovosti materiala, potrebnega za postavitev omrežij različnih velikosti. Operater sistema mora izbrati ustrezen material, da zadosti minimalni kakovosti signala pri naročnikovem izhodu in da optimizira strošek/zmogljivost ob upoštevanju velikosti omrežja in lokalnih okoliščin. Vse zahteve in objavljene podatke je treba razumeti kot zagotovljene vrednosti v določenem frekvenčnem razponu in v enakih okoliščinah.
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-julij-2011
1DGRPHãþD
SIST EN 50083-3:2003
SIST EN 60728-3:2008
Kabelska omrežja za televizijske in zvokovne signale ter interaktivne storitve - 3.
del: Aktivna širokopasovna oprema za koaksialna kabelska omrežja (IEC 60728-
3:2010)
Cable networks for television signals, sound signals and interactive services - Part 3:
Active wideband equipment for cable networks (IEC 60728-3:2010)
Kabelnetze für Fernsehsignale, Tonsignale und interaktive Dienste - Teil 3: Aktive
Breitbandgeräte für koaxiale Kabelnetze (IEC 60728-3:2010)
5pVHDX[GHGLVWULEXWLRQSDUFkEOHVSRXUVLJQDX[GHWpOpYLVLRQVLJQDX[GHUDGLRGLIIXVLRQ
VRQRUHHWVHUYLFHVLQWHUDFWLIV3DUWLH0DWpULHODFWLIjODUJHEDQGHSRXU
UpVHDX[GHGLVWULEXWLRQSDUFkEOHV&(,
Ta slovenski standard je istoveten z: EN 60728-3:2011
ICS:
33.060.40 Kabelski razdelilni sistemi Cabled distribution systems
33.120.10 Koaksialni kabli. Valovodi Coaxial cables. Waveguides
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN 60728-3
NORME EUROPÉENNE
February 2011
EUROPÄISCHE NORM
ICS 33.060.40; 33.170 Supersedes EN 60728-3:2006
English version
Cable networks for television signals, sound signals and interactive
services -
Part 3: Active wideband equipment for cable networks
(IEC 60728-3:2010)
Réseaux de distribution par câbles pour Kabelnetze für Fernsehsignale,
signaux de télévision, signaux de Tonsignale und interaktive Dienste -
radiodiffusion sonore et services Teil 3: Aktive Breitbandgeräte für koaxiale
interactifs - Kabelnetze
Partie 3: Matériel actif à large bande pour (IEC 60728-3:2010)
réseaux de distribution par câbles
(CEI 60728-3:2010)
This European Standard was approved by CENELEC on 2011-01-13. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Management Centre: Avenue Marnix 17, B - 1000 Brussels
© 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60728-3:2011 E
Foreword
The text of document 100/1746/FDIS, future edition 4 of IEC 60728-3, prepared by Technical Area 5,
Cable networks for television signals, sound signals and interactive services, of IEC TC 100, Audio, video
and multimedia systems and equipment, was submitted to the IEC-CENELEC parallel vote and was
approved by CENELEC as EN 60728-3 on 2011-01-13.
This European Standard supersedes EN 60728-3:2006.
– extension of upper frequency range limit for cable network equipment from 862 MHz to 1 000 MHz;
– method of measurement and requirements for immunity to surge voltages;
– extension of scope to equipment using symmetrical ports;
– additional normative references;
– additional terms and definitions and abbreviations.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent
rights.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
(dop) 2011-10-13
national standard or by endorsement
– latest date by which the national standards conflicting
(dow) 2014-01-13
with the EN have to be withdrawn
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 60728-3:2010 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:
IEC 60728-6:2003 NOTE Harmonized as EN 60728-6:2003 (not modified).
IEC 60728-10 NOTE Harmonized as EN 60728-10.
IEC 61169-2 NOTE Harmonized as EN 61169-2.
IEC 61169-24 NOTE Harmonized as EN 61169-24.
__________
- 3 - EN 60728-3:2011
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year
IEC 60065 - Audio, video and similar electronic apparatus -EN 60065 -
Safety requirements
IEC 60068-1 1988 Environmental testing - EN 60068-1 1994
Part 1: General and guidance
IEC 60068-2-1 - Environmental testing - EN 60068-2-1 -
Part 2-1: Tests - Test A: Cold
IEC 60068-2-2 - Environmental testing - EN 60068-2-2 -
Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-6 - Environmental testing - EN 60068-2-6 -
Part 2-6: Tests - Test Fc: Vibration
(sinusoidal)
IEC 60068-2-14 - Environmental testing - EN 60068-2-14 -
Part 2-14: Tests - Test N: Change of
temperature
IEC 60068-2-27 - Environmental testing - EN 60068-2-27 -
Part 2-27: Tests - Test Ea and guidance:
Shock
IEC 60068-2-29 - Environmental testing - EN 60068-2-29 -
Part 2: Tests - Test Eb and guidance: Bump
IEC 60068-2-30 - Environmental testing - EN 60068-2-30 -
Part 2-30: Tests - Test Db: Damp heat, cyclic
(12 h + 12 h cycle)
IEC 60068-2-31 - Environmental testing - EN 60068-2-31 -
Part 2-31: Tests - Test Ec: Rough handling
shocks, primarily for equipment-type
specimens
IEC 60068-2-32 - Environmental testing. EN 60068-2-32 -
Part 2-32: Tests. Test Ed: Free fall
IEC 60068-2-40 - Basic environmental testing procedures - EN 60068-2-40 -
Part 2-40: Tests - Test Z/AM: Combined
cold/low air pressure tests
IEC 60068-2-48 - Environmental testing - EN 60068-2-48 -
Part 2-48: Tests - Guidance on the application
of the tests of IEC 60068 to simulate the
effects of storage
IEC 60529 - Degrees of protection provided by enclosures - -
(IP Code)
Publication Year Title EN/HD Year
IEC 60728-1 - Cable networks for television signals, sound EN 60728-1 -
signals and interactive services -
Part 1: System performance of forward paths
IEC 60728-2 - Cabled distribution systems for television and EN 50083-2 -
sound signals -
Part 2: Electromagnetic compatibility for
equipment
IEC 60728-4 - Cable networks for television signals, sound EN 60728-4 -
signals and interactive services -
Part 4: Passive wideband equipment for
coaxial cable networks
IEC 60728-5 - Cable networks for television signals, sound EN 60728-5 -
signals and interactive services -
Part 5: Headend equipment
IEC 60728-11 - Cable networks for television signals, sound EN 60728-11 -
signals and interactive services -
Part 11: Safety
IEC 60950-1 - Information technology equipment - Safety - EN 60950-1 -
Part 1: General requirements
IEC 61000-4-5 - Electromagnetic compatibility (EMC) - EN 61000-4-5 -
Part 4-5: Testing and measurement
techniques - Surge immunity test
IEC 61319-1 - Interconnections of satellite receiving EN 61319-1 -
equipment -
Part 1: Europe
IEC 61319-2 - Interconnections of satellite receiving - -
equipment -
Part 2: Japan
ITU-T - Transmission aspects of unbalance about - -
Recommendation earth
G.117
ITU-T - Measuring arrangements to assess the - -
Recommendation degree of unbalance about earth
O.9
IEC 60728-3 ®
Edition 4.0 2010-12
INTERNATIONAL
STANDARD
colour
inside
Cable networks for television signals, sound signals and interactive services –
Part 3: Active wideband equipment for cable networks
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
PRICE CODE
XB
ICS 33.060.40; 33.170 ISBN 978-2-88912-251-6
– 2 – 60728-3 ã IEC:2010(E)
CONTENTS
FO R EW OR D . 6
IN T R OD U CT ION . 8
1 Sc op e . . 9
2 Normative references . 9
3 Terms, definitions, symbols and abbreviations . 11
3.1 Terms and definitions . 11
3.2 Sym bol s . 15
3.3 Abbreviations . 16
4 Methods of measurement . 17
4.1 Ge ne ral . 17
4.2 Linear distortion . 18
4.2.1 Return loss . 18
4.2.2 Flatness . 19
4.2.3 Chrominance/luminance delay inequality for PAL/SECAM only . 19
4.3 Non-linear distortion . 20
4.3.1 General . 20
4.3.2 Types of measurements. 20
4.3.3 Inte r m od ulation . 20
4.3.4 Composite triple beat . 22
4.3.5 Composite second order beat . 25
4.3.6 Com posite crossmodulation . 26
4.3.7 Method of measurement of non-linearity for pure digital channel load . 29
4.3.8 Hum modulation of carrier. 29
4.4 Automatic gain and slope control step response . 33
4.4.1 Def initions . 33
4.4.2 Equipment required . 33
4.4.3 Connection of equipment . 34
4.4.4 Mea surement procedure . 34
4.5 Noise figure . 35
4.5.1 General . 35
4.5.2 Equipment required . 35
4.5.3 Connection of equipment . 35
4.5.4 Mea surement procedure . 35
4.6 Crosstal k attenuation . 36
4.6.1 Crosstalk attenuation for loop through ports. 36
4.6.2 Crosstalk attenuation for output ports . 36
4.7 Signal level for digitally modulated signals . 38
4.8 Measurement of composite intermodulation noise ratio (CINR ) . 38
4.8.1 General . 38
4.8.2 Equipment required . 38
4.8.3 Connection of equipment . 39
4.8.4 Mea surement procedure . 40
4.8.5 Presentation of the results . 40
4.9 Immunity to surge voltages .
...
Questions, Comments and Discussion