Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-3: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Disturbance power

This part of CISPR 16 is designated a basic standard, which specifies the characteristics and calibration of the absorbing clamp for the measurement of radio disturbance power in the frequency range 30 MHz to 1 GHz. This second edition cancels and replaces the first edition published in 2003. It constitutes a technical revision. In this edition a more detailed calibration method for the absorbing clamp is specified. Furthermore, new alternative calibration methods are introduced which are more practicable than the one which was specified previously. Additional parameters to describe the absorbing clamp are defined, like the decoupling factor for the broadband absorber (DF) and the decoupling factor for the current transformer (DR), along with their validation methods. A procedure for the validation of the absorbing clamp test site (ACTS) is also included in the document.

Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Teil 1-3: Geräte und Einrichtungen zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Zusatz-/Hilfseinrichtungen - Störleistungsmessung

Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques - Partie 1-3: Appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques - Matériels auxiliaires - Puissance perturbatrice

La présente partie de la CISPR 16 est une norme fondamentale qui spécifie les caractéristiques et l'étalonnage de la pince absorbante pour la mesure de la puissance perturbatrice radioélectrique dans la gamme de fréquences de 30 MHz à 1 GHz. Cette deuxième édition annule et remplace la première édition parue en 2003. Elle constitue une révision technique. Cette édition spécifie une méthode d'étalonnage plus détaillée pour la pince absorbante. De plus, de nouvelles méthodes d'étalonnage possibles sont introduites, qui sont plus praticables que celle qui était spécifiée auparavant. Des paramètres additionnels pour décrire la pince absorbante sont définis, tels le facteur de découplage pour l'absorbeur large bande DF et le facteur de découplage pour le transformateur de courant DR

Specifikacija za merilne naprave in metode za merjenje radijskih motenj in odpornosti - 1-3. del: Merilne naprave za merjenje radijskih motenj in odpornosti - Pomožna oprema - Moč motenj (CISPR 16-1-3:2004)

Ta del standarda CISPR 16 je osnovni standard, ki določa lastnosti in umerjanje absorbirnih klešč za merjenje moči radijskih motenj v frekvenčnem območju med 30 MHz in 1 GHz.

General Information

Status
Published
Publication Date
29-Nov-2006
Withdrawal Date
30-Jun-2009
Current Stage
6060 - Document made available - Publishing
Start Date
30-Nov-2006
Completion Date
30-Nov-2006

Relations

Buy Standard

Standard
EN 55016-1-3:2007
English language
35 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI SIST EN 55016-1-3:2007

STANDARD
marec 2007
Specifikacija merilnih naprav in metod za merjenje radijskih motenj in
odpornosti - 1-3. del: Merilne naprave za merjenje radijskih motenj in
odpornosti - Pomožna oprema – Moč motenj (CISPR 16-1-3:2004)
Specification for radio disturbance and immunity measuring apparatus and
methods - Part 1-3: Radio disturbance and immunity measuring apparatus -
Ancillary equipment - Disturbance power (CISPR 16-1-3:2004)
ICS 17.220.20; 33.100.20 Referenčna številka
SIST EN 55016-1-3:2007(en)
©  Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljeno

---------------------- Page: 1 ----------------------

EUROPEAN STANDARD
EN 55016-1-3

NORME EUROPÉENNE
November 2006
EUROPÄISCHE NORM

ICS 33.100.10;33.100.20 Supersedes EN 55016-1-3:2004


English version

Specification for radio disturbance
and immunity measuring apparatus and methods
Part 1-3: Radio disturbance and immunity measuring apparatus -
Ancillary equipment -
Disturbance power
(CISPR 16-1-3:2004)

Spécifications des méthodes  Anforderungen an Geräte
et des appareils de mesure und Einrichtungen sowie Festlegung
des perturbations radioélectriques der Verfahren zur Messung
et de l'immunité aux perturbations der hochfrequenten Störaussendung
radioélectriques (Funkstörungen) und Störfestigkeit
Partie 1-3: Appareils de mesure Teil 1-3: Geräte und Einrichtungen
des perturbations radioélectriques zur Messung der hochfrequenten
et de l'immunité aux perturbations Störaussendung (Funkstörungen)
radioélectriques - und Störfestigkeit -
Matériels auxiliaires - Zusatz-/Hilfseinrichtungen -
Puissance perturbatrice Störleistungsmessung
(CISPR 16-1-3:2004) (CISPR 16-1-3:2004)

This European Standard was approved by CENELEC on 2006-07-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, the Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels


© 2006 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 55016-1-3:2006 E

---------------------- Page: 2 ----------------------

EN 55016-1-3:2006 - 2 -
Foreword

The text of the International Standard CISPR 16-1-3:2004, prepared by CISPR SC A, Radio-interference
measurements and statistical methods, was submitted to the CENELEC Unique Acceptance Procedure
and was approved by CENELEC as EN 55016-1-3 on 2006-07-01.

This European Standard supersedes EN 55016-1-3:2004.

In this EN 55016-1-3:2006, a more detailed calibration method for the absorbing clamp is specified.
Furthermore, new alternative calibration methods are introduced which are more practicable than the one
that was specified previously. Additional parameters to describe the absorbing clamp are defined, like the
decoupling factor for the broadband absorber (DF) and the decoupling factor for the current transformer
(DR), along with their validation methods. A procedure for the validation of the absorbing clamp test site
(ACTS) is also included in the document.

The following dates were fixed:

– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2007-07-01

– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2009-07-01
Annex ZA has been added by CENELEC.
__________

Endorsement notice
The text of the International Standard CISPR 16-1-3:2004, including the corrigendum February 2006, was
approved by CENELEC as a European Standard without any modification.
__________

---------------------- Page: 3 ----------------------

- 3 - EN 55016-1-3:2006
Annex ZA
(normative)

Normative references to internati
...

Questions, Comments and Discussion