EN 55016-1-3:2006
(Main)Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-3: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Disturbance power
Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-3: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Disturbance power
This part of CISPR 16 is designated a basic standard, which specifies the characteristics and calibration of the absorbing clamp for the measurement of radio disturbance power in the frequency range 30 MHz to 1 GHz. This second edition cancels and replaces the first edition published in 2003. It constitutes a technical revision. In this edition a more detailed calibration method for the absorbing clamp is specified. Furthermore, new alternative calibration methods are introduced which are more practicable than the one which was specified previously. Additional parameters to describe the absorbing clamp are defined, like the decoupling factor for the broadband absorber (DF) and the decoupling factor for the current transformer (DR), along with their validation methods. A procedure for the validation of the absorbing clamp test site (ACTS) is also included in the document.
Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Teil 1-3: Geräte und Einrichtungen zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Zusatz-/Hilfseinrichtungen - Störleistungsmessung
Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques - Partie 1-3: Appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques - Matériels auxiliaires - Puissance perturbatrice
La présente partie de la CISPR 16 est une norme fondamentale qui spécifie les caractéristiques et l'étalonnage de la pince absorbante pour la mesure de la puissance perturbatrice radioélectrique dans la gamme de fréquences de 30 MHz à 1 GHz. Cette deuxième édition annule et remplace la première édition parue en 2003. Elle constitue une révision technique. Cette édition spécifie une méthode d'étalonnage plus détaillée pour la pince absorbante. De plus, de nouvelles méthodes d'étalonnage possibles sont introduites, qui sont plus praticables que celle qui était spécifiée auparavant. Des paramètres additionnels pour décrire la pince absorbante sont définis, tels le facteur de découplage pour l'absorbeur large bande DF et le facteur de découplage pour le transformateur de courant DR
Specifikacija za merilne naprave in metode za merjenje radijskih motenj in odpornosti - 1-3. del: Merilne naprave za merjenje radijskih motenj in odpornosti - Pomožna oprema - Moč motenj (CISPR 16-1-3:2004)
Ta del standarda CISPR 16 je osnovni standard, ki določa lastnosti in umerjanje absorbirnih klešč za merjenje moči radijskih motenj v frekvenčnem območju med 30 MHz in 1 GHz.
General Information
Relations
Standards Content (Sample)
SLOVENSKI SIST EN 55016-1-3:2007
STANDARD
marec 2007
Specifikacija merilnih naprav in metod za merjenje radijskih motenj in
odpornosti - 1-3. del: Merilne naprave za merjenje radijskih motenj in
odpornosti - Pomožna oprema – Moč motenj (CISPR 16-1-3:2004)
Specification for radio disturbance and immunity measuring apparatus and
methods - Part 1-3: Radio disturbance and immunity measuring apparatus -
Ancillary equipment - Disturbance power (CISPR 16-1-3:2004)
ICS 17.220.20; 33.100.20 Referenčna številka
© Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljeno
EUROPEAN STANDARD
EN 55016-1-3
NORME EUROPÉENNE
November 2006
EUROPÄISCHE NORM
ICS 33.100.10;33.100.20 Supersedes EN 55016-1-3:2004
English version
Specification for radio disturbance
and immunity measuring apparatus and methods
Part 1-3: Radio disturbance and immunity measuring apparatus -
Ancillary equipment -
Disturbance power
(CISPR 16-1-3:2004)
Spécifications des méthodes Anforderungen an Geräte
et des appareils de mesure und Einrichtungen sowie Festlegung
des perturbations radioélectriques der Verfahren zur Messung
et de l'immunité aux perturbations der hochfrequenten Störaussendung
radioélectriques (Funkstörungen) und Störfestigkeit
Partie 1-3: Appareils de mesure Teil 1-3: Geräte und Einrichtungen
des perturbations radioélectriques zur Messung der hochfrequenten
et de l'immunité aux perturbations Störaussendung (Funkstörungen)
radioélectriques - und Störfestigkeit -
Matériels auxiliaires - Zusatz-/Hilfseinrichtungen -
Puissance perturbatrice Störleistungsmessung
(CISPR 16-1-3:2004) (CISPR 16-1-3:2004)
This European Standard was approved by CENELEC on 2006-07-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, the Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2006 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 55016-1-3:2006 E
Foreword
The text of the International Standard CISPR 16-1-3:2004, prepared by CISPR SC A, Radio-interference
measurements and statistical methods, was submitted to the CENELEC Unique Acceptance Procedure
and was approved by CENELEC as EN 55016-1-3 on 2006-07-01.
This European Standard supersedes EN 55016-1-3:2004.
In this EN 55016-1-3:2006, a more detailed calibration method for the absorbing clamp is specified.
Furthermore, new alternative calibration methods are introduced which are more practicable than the one
that was specified previously. Additional parameters to describe the absorbing clamp are defined, like the
decoupling factor for the broadband absorber (DF) and the decoupling factor for the current transformer
(DR), along with their validation methods. A procedure for the validation of the absorbing clamp test site
(ACTS) is also included in the document.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2007-07-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2009-07-01
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard CISPR 16-1-3:2004, including the corrigendum February 2006, was
approved by CENELEC as a European Standard without any modification.
__________
- 3 - EN 55016-1-3:2006
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year
CISPR 16-1-2 2003 Specification for radio disturbance and EN 55016-1-2 2004
immunity measuring apparatus and methods
Part 1-2: Radio disturbance and immunity
measuring apparatus - Ancillary equipment -
Conducted disturbances
CISPR 16-2-2 2003 Specification for radio disturbance and EN 55016-2-2 2004
immunity measuring apparatus and methods
Part 2-2: Methods of measurement of
disturbances and immunity - Measurement of
disturbance power
1) 2)
CISPR 16-4-2 - Specification for radio disturbance and EN 55016-4-2 2004
immunity measuring apparatus and methods
Part 4-2: Uncertainties, statistics and limit
modelling - Uncertainty in EMC
measurements
IEC 60050-161 1990 International Electrotechnical Vocabulary - -
+ A1 1997 (IEV) - Chapter 161: Electromagnetic - -
+ A2 1998 compatibility - -
1)
Undated reference.
2)
Valid edition at date of issue.
INTERNATIONAL
CISPR
ELECTROTECHNICAL
16-1-3
COMMISSION
Second edition
2004-06
INTERNATIONAL SPECIAL COMMITTEE ON RADIO INTERFERENCE
Specification for radio disturbance and immunity
measuring apparatus and methods –
Part 1-3:
Radio disturbance and immunity measuring
apparatus – Ancillary equipment –
Disturbance power
IEC 2004 Copyright - all rights reserved
No part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical,
including photocopying and microfilm, without permission in writing from the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
PRICE CODE
V
Commission Electrotechnique Internationale
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
For price, see current catalogue
CISPR 16-1-3 IEC:2004 – 3 –
CONTENTS
FOREWORD.5
1 Scope.9
2 Normative references.9
3 Terms, definitions and abbreviations .9
4 Absorbing clamp instrumentation.11
Annex A (informative) Construction of the absorbing clamp (Subclause 4.2) .35
Annex B (normative) Calibration and validation methods for the absorbing clamp and
the secondary absorbing device (Clause 4).39
Annex C (normative) Validation of the absorbing clamp test site (Clause 4) .59
Figure 1 – Overview of the absorbing clamp measurement method and the associated
calibration and validation procedures.27
Figure 2 – Schematic overview of the absorbing clamp test method.31
Figure 3 – Schematic overview of the clamp calibration methods .33
Figure A.1 – The absorbing clamp assembly and its parts.35
Figure A.2 – Example of the construction of an absorbing clamp.37
Figure B.1 – The original calibration site .51
Figure B.2 – Position of guide for centering the lead under test .51
Figure B.3 – Side view of the calibration jig .53
Figure B.4 – Top view of the jig .53
Figure B.5 – View of the jigs vertical flange .53
Figure B.6 – Test set-up for the reference device calibration method .55
Figure B.7 – Specification of the reference device .55
Figure B.8 – Measurement set-up of the decoupling factor DF .57
Figure B.9 – Measurement set-up of the decoupling factor DR.57
Figure C.1 – Test set-ups for the site attenuation measurement for clamp site
validation using the reference device .63
Table 1 – Overview of the characteristics of the three-clamp calibration methods and
their relation .29
CISPR 16-1-3 IEC:2004 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
INTERNATIONAL SPECIAL COMMITTEE ON RADIO INTERFERENCE
___________
SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY
MEASURING APPARATUS AND METHODS –
Part 1-3: Radio disturbance and immunity measuring apparatus –
Ancillary equipment – Disturbance power
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard CISPR 16-1-3 has been prepared by CISPR subcommittee A: Radio
interference measurements and statistical methods.
This second edition cancels and replaces the first edition published in 2003. It constitutes a
technical revision. In this edition a more detailed calibration method for the absorbing clamp is
specified. Furthermore, new alternative calibration methods are introduced which are more
practicable than the one which was specified previously. Additional parameters to describe
the absorbing clamp are defined, like the decoupling factor for the broadband absorber (DF)
and the decoupling factor for the current transformer (DR), along with their validation
methods. A procedure f
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.