Luminaires - Part 1: General requirements and tests

This Part 1 of IEC 60598 specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. The requirements and related tests of this document cover: classification, marking, mechanical construction, electrical construction and photobiological safety.

Leuchten - Teil 1: Allgemeine Anforderungen und Prüfungen

Luminaires - Partie 1: Exigences générales et essais

Svetilke - 1. del: Splošne zahteve in preskusi - Dopolnilo A11

Ta 1. del standarda IEC 60598 določa splošne zahteve za svetilke, ki vsebujejo električne svetlobne vire, namenjene za delovanje z omrežnim napajanjem do 1000 V. Zahteve in preskusi iz tega dokumenta zajemajo: klasifikacijo, označevanje, mehansko zasnovo, električno zasnovo in fotobiološko varnost.

General Information

Status
Published
Publication Date
07-Apr-2022
Current Stage
6060 - Document made available - Publishing
Start Date
08-Apr-2022
Due Date
20-Apr-2022
Completion Date
08-Apr-2022

Relations

Buy Standard

Amendment
EN IEC 60598-1:2021/A11:2022
English language
7 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-junij-2022
Svetilke - 1. del: Splošne zahteve in preskusi - Dopolnilo A11
Luminaires - Part 1: General requirements and tests
Leuchten - Teil 1: Allgemeine Anforderungen und Prüfungen
Luminaires - Partie 1: Exigences générales et essais
Ta slovenski standard je istoveten z: EN IEC 60598-1:2021/A11:2022
ICS:
29.140.40 Svetila Luminaires
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN IEC 60598-1:2021/A11

NORME EUROPÉENNE
EUROPÄISCHE NORM April 2022
ICS 29.140.40
English Version
Luminaires - Part 1: General requirements and tests
Luminaires - Partie 1: Exigences générales et essais Leuchten - Teil 1: Allgemeine Anforderungen und
Prüfungen
This amendment A11 modifies the European Standard EN IEC 60598-1:2021; it was approved by CENELEC on 2022-02-16. CENELEC
members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this amendment the
status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language made by translation under the
responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as
the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2022 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN IEC 60598-1:2021/A11:2022 E

Contents Page
European foreword . 5
1 Modification to the “Endorsement notice” . 6
2 Modification to “SECTION 3: MARKING” . 6
3 Modification to “SECTION 4: CONSTRUCTION” . 6
4 Modification to “SECTION 5: EXTERNAL AND INTERNAL WIRING” . 6
5 Modification to “SECTION 12: ENDURANCE TEST AND THERMAL TEST” . 7
6 Addition of Annex ZB, “Special national conditions” and Annex ZC, “A-deviations” . 7
7 Addition to the Bibliography . 9

European foreword
This document (EN IEC 60598-1:2021/A11:2022) has been prepared by CLC/TC 34 ”Lighting”.
The following dates are fixed:
• latest date by which this document has to be (dop) 2023-02-16
implemented at national level by publication of
an identical national standard or by
endorsement
• latest date by which the national standards (dow) 2025-02-16
conflicting with this document have to be
withdrawn
This document amends EN IEC 60598-1:2021.
This amendment was developed to introduce common modifications and special national conditions in
EN IEC 60598-1:2021.
This document has been prepared under a Standardization Request given to CENELEC by the
European Commission and the European Free Trade Association, and supports essential requirements
of EU Directive(s) / Regulation(s).
For the relationship with EU Directive(s)) / Regulation(s), see informative Annex ZZ, which is an integral
part of EN IEC 60598-1:2021.
Any feedback and questions on this document should be directed to the users’ national committee. A
complete listing of these bodies can be found on the CENELEC website.
1 Modification to the “Endorsement notice”
Replace the last two lines with the following:
“The text of the International Standard IEC 60598-1:2020 was approved by CENELEC as a European
Standard with agreed common modifications.”
2 Modification to “SECTION 3: MARKING”
In 3.2.12, delete NOTE 4.
3 Modification to “SECTION 4: CONSTRUCTION”
In 4.11.6, at the end of the paragraph commencing with “Following completion of these tests.”, add the
following text:
“the test voltage however being reduced to 1 500 V”.
4 Modification to “SECTION 5: EXTERNAL AND INTERNAL WIRING”
In 5.2.2, paragraph 1, replace “IEC 60227 (all parts) and IEC 60245 (all parts)”, by
“EN 50525 (all parts)”, and delete paragraph 2.
Replace Table 5.1 by the following new table:

Table 5.1 — Supply cord
Luminaire Rubber PVC No insulation
c c
Ordinary class I luminaires
H03RT-H H03VVH2-F
c
H03VV-F
c c
Ordinary class II luminaires
H05RR-F H03VVH2-F
c
H03VV-F
c a c
Luminaires other than ordinary class I
H05RN-F H03VVH2-F
and II
a c
H03VV-F
c
Portable rough service luminaires
H07RN-F
Class III or with SELV or PELV circuits  Uninsulated
b
luminaires
conductor
AC: U ≤ 25 V
DC: U ≤ 60V
Interrupted DC voltage for frequencies
between 10 Hz and
200 Hz: ≤ 25 V peak
Class III or with SELV or PELV circuits Unsheathed basic insulated
luminaires conductor
AC: 25 V < U ≤ 50 V
DC: 60 V < U ≤ 120 V
Luminaire Rubber PVC No insulation
a
For indoor use only.
b
In accordance with IEC 60364 (all parts) uninsulated conductors are not allo
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.