This part of IEC 60598 specifies requirements for recessed luminaires incorporating electric light sources for operation from supply voltages up to 1 000 V. It also specifies requirements for recessed air-handling luminaires for use with a ventilation duct or ventilated space (plenum). NOTE The expressions “ventilation” and “ventilated” in this section refer to forced ventilation.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62722-2-1:2023 specifies the performance requirements for LED luminaires, together with the test methods and conditions. It applies to LED luminaires for general lighting purposes. Semi-luminaires are not covered under the scope of this document. This second edition cancels and replaces the first edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
alignment with IEC 62717:2014, IEC 62717:2014/AMD1:2015 and IEC 62717:2014/AMD2:2019;
clarification of temperature requirements for the maintenance test, in 10.2 and Annex A;
introduction of a new Annex C on methods for calculation and measurements of parameters for extension of electric and photometric data.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEXT ACTION: PUBLICATION EXPECTED BY 2020-04

  • Amendment
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60598-2-20:2022 is available as IEC 60598-2-20:2022 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60598-2-20:2022 specifies requirements for lighting chains fitted with series, parallel or a combination of series/parallel connected light sources for use either indoors or outdoors on supply voltages not exceeding 250 V. This fifth edition cancels and replaces the fourth edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - specific provisions for temporarily installed protected lighting (TPL) chains have been added; - new terms and definitions have been added.

  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60598 specifies requirements for fixed luminaires intended for use in the water, or in contact with the water, in, for example, the basins of swimming pools, fountains, paddling pools, and garden pools, for use with electric light sources. NOTE Electrical installation rules for swimming pools are given in IEC 60364-7-702. This document does not cover luminaires not in contact with the water (e.g. mounted behind a glass panel which is separate from the luminaire) or hand-held or portable luminaires.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 62722 covers specific performance and environmental requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. Unless otherwise detailed, performance data covered under the scope of this document are for the luminaires in a condition representative of new manufacture, with any specified initial aging procedures completed. This document covers requirements for luminaires to support energy efficient use and responsible environmental management to the end of life. The object of this document is to provide a set of requirements which are considered to be generally applicable to most types of luminaires. Where additional performance requirements for specific types of light source are relevant, these are specified in the IEC 62722-2 series. The IEC 62722-2 series can also cover a wider scope of performance aspects appropriate to the particular light source technology. Semi-luminaires are not covered under the scope of this document. For some types of luminaires (e.g. decorative or household) the provision of performance data under the scope of this document is not appropriate.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60598 specifies requirements for emergency luminaires for use with electrical lamps on emergency power supplies not exceeding 1 000 V. This document does not cover the effects of non-emergency voltage reductions on luminaires incorporating high pressure discharge lamps. This document gives general requirements for emergency lighting equipment. In this document, the term "lamp" which also includes "light source(s)" where appropriate, is used.

  • Standard
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2018-09-14 PeC: Cited under the LVD in C 326/02
20180129: BT decision D139/C142 for implementation dates

  • Amendment
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60598-2-1:2020 specifies requirements for fixed general purpose luminaires for use with electric light sources on supply voltages not exceeding 1 000 V. This second edition cancels and replaces the first edition published in 1979 and Amendment 1:1987. This edition constitutes a technical revision. This edition includes the following technical changes with respect to the previous edition (there are no major technical changes, see Annex A): a) the scope has been modified to be in line with Part 1 to include all electric light sources, b) references to Part 1 have been updated.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEW!IEC 60598-2-4:2017 is available as IEC 60598-2-4:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60598-2-4:2017 specifies requirements for portable general purpose luminaires for indoor and/or outdoor use (e.g. garden use), other than handlamps, designed to be used with or incorporating electrical light sources on supply voltages not exceeding 250 V. This third edition cancels and replaces the second edition published in 1997. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - alignment with IEC 60598-1; - modification of the scope, classification and requirements to cover portable luminaires for both indoor and outdoor applications, by introducing the requirements already listed in IEC 60598-2-7; NOTE In this edition of IEC 60598-2-4 all requirements listed in IEC 60598-2-7 have been incorporated. As a consequence, IEC 60598-2-7 will be withdrawn after publication of this standard. - modification of the scope to cover all electrical light sources (it was previously limited to tungsten filament, tubular fluorescent and other discharge lamps); - introduction of the symbol for luminaires which are other than ordinary, but suitable for indoor applications only (e.g. luminaire using PVC cable); - modification in the detail of test to clarify that the stability test on an inclined plane (see 4.7.3) shall be carried out with the light source(s) in place; - modification of the minimum degree of protection against dust and moisture for portable luminaires for outdoor use from IPX3 to IPX4 (see 4.5.2); as a consequence, the requirements for cable entry position, as given in IEC 60598-2-7:1982, 7.6.3 were deleted as they are covered by IPX4; - modification of the requirements for the acceptance criteria of plug and socket outlet; - modification of the IP test requiring the most unfavourable of the overturned positions to cover all classes (and not only class II luminaires as in 7.13.1 of IEC 60598-2-7:1982).

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60598-2-17:2017 specifies requirements for stage, television, film and photographic studio luminaires (including spot and floodlighting projectors) for use outdoors and indoors, with electric light sources on supply voltages not exceeding 1 000 V. This second edition cancels and replaces the first edition published in 1984 and Amendement 2:1990. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) extension of the applicable scope from light source to electric light source and replacement of "tungsten filament, tubular fluorescent and other discharge lamps" with "electric light source" in 17.1. b) consideration of the fact that there are many LED luminaires with non-replaceable light source, and light source without a glass bulb, or with low operation temperature: the applicable scope of relevant clauses therefore only applies to replaceable light source luminaires with a glass bulb lamp, or with high surface temperature.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60598-1:2020 is available as IEC 60598-1:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60598-1:2020 specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. The requirements and related tests of this document cover: classification, marking, mechanical construction, electrical construction and photobiological safety. This ninth edition cancels and replaces the eighth edition published in 2014 and Amendment 1:2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - Revision of Clause 4.30, Fixing cover live parts of non-user replaceable light source; - Subclause 4.24.2, Blue Light Hazard: removal of Risk Group 0; - Subclause 5.2.16: additional requirements for AC mains appliance inlets related to IEC 61984; - Addition of Subclause 3.3.25, UV protection of cable; - Addition of Clause 4.34, Inclusion of EMF safety requirements (IEC 62493); - Revision of the requirements for functional earth and protective earth; - Addition of Clause 4.35, Protection against fast rotating parts; - Revision of Clause 3.2, Rated voltage marking; - Revision of Subclause 5.2.10, Cord anchorage; - Revision of Annex G for touch current and protective conductor current test set-up; - Addition of requirements for constant light output function and programmable current output; - Revision of Subclause 8.2.3 c), touch voltage limits for interrupted DC voltage; - Introduction of PELV; - Introduction of Ethernet power supply connection for luminaires (PoE); - Section 9, Introduction of IPX9; - Addition of Subclause 3.3.26 for wall mounted luminaires; - Revision of Annex D introducing alternative thermal tests for luminaires with ta marking higher than 25°C; - Revision of Table 10.3 and Subclause 3.3.19 for protective conductor current limits; - Track-mounted luminaires: cross reference to Annex A of IEC 60570:2003/AMD2:2019; - Revision of Subclause 10.2.2, alternative DC electric strength test; - Revision of Annex D for recessed luminaires; - Subclause 4.12.5: revision of Table 4.2 for torque test on metal glands; - Revision of use of bridging capacitors in luminaires; - Revision of electrical connection to class III plugs.

  • Standard
    239 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60598-2-23:2020 specifies requirements for extra-low-voltage lighting systems for ELV light sources, intended for ordinary interior use on supply voltages not exceeding 1 000 V. The luminaires, being connected in parallel, are supplied via freely suspended continuous supporting conductors or profiles, the current in the ELV part of the system not exceeding 25 A. This second edition cancels and replaces the first edition published in 1996 and Amendment 1:2000. This edition constitutes a technical revision. This edition includes the following technical changes with respect to the previous edition (there are no major technical changes, see Annex A): a) The title has been modified to allow the inclusion of other light sources; b) The scope has been updated to be aligned with the other parts of the IEC 60598-2 series and to include other light sources; c) Normative references and the reference to transformer and controlgear standards have been updated; d) The short circuit test (23.7.6.1 and 23.7.6.2) was removed and reference is now made to the same test in Part 1.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEXT ACTION: CCMC to finalize publication
2019-11-13 PeC: BT approved the publication
2019-03-21 - GEM - TC discussed with consultant (C. Maes) at meeting (MArch 2019) - comments accepted - Annex ZA to be dated. Project has normative refverence to PR=63474, which creates a dependency.
2019-02-28 PC: to be flagged for LVD citation when ready
2018-12-17 PC: "Lack of compliance" for LVD, undated references in the Annex ZA and some points in the standards should be clarified
2017-11-21 - Negative assessment is received during CDV stage. Consultant assessment request is missing for FDIS.

  • Amendment
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Part 2 of IEC 60598 specifies requirements for ground recessed luminaires incorporating electric light sources for operation from supply voltages up to 1 000 V, for indoor or outdoor use, e.g. in gardens, yards, carriageways, parking lots, cycleways, footways, pedestrian areas, swimming pools areas outside zones for SELV, nurseries and similar applications.

  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62722-2-1:2014 specifies the performance requirements for LED luminaires, together with the test methods and conditions, required to show compliance with this standard. It applies to LED luminaires for general lighting purposes. This first edition of IEC 62722-2-1 cancels and replaces IEC PAS 62722-2-1. published in 2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the Publicly Available Specification. a) The testing time is aligned with IEC 62717 and the option of 2 000 h is removed. Products containing modules not in compliance with IEC 62717 are now tested to 6 000 h. b) Testing sample sizes have been modified to give valid statistical data. c) The temperature reduction of 10 °C for street lanterns and floodlights has been removed. d) Life definitions have been updated and aligned with IEC 62717.

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62722-1:2014 covers specific performance and environmental requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. Unless otherwise detailed, performance data covered under the scope of this standard are for the luminaires in a condition representative of new manufacture, with any specified initial aging procedures completed. This first edition cancels and replaces IEC PAS 62722-1 published in 2011 and constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC PAS 62722-1. a) The inclusion of more precise requirements for the comparison of the photometric distribution shape, with the comparison method given in Annex D. b) Further regional standards added to the schedule given in Annex A.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60598-2-5:2015 specifies requirements for floodlights for use with electrical light sources on supply voltages not exceeding 1 000 V. This third edition cancels and replaces the second edition published in 1998, and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: it introduces requirements for the glass breaking test.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60598-2-21:2014 specifies requirements for rope lights (sealed lighting chains) fitted with non-replaceable series- or parallel- or a combination of series/parallel-connected light sources for use either indoors or outdoors on supply voltages not exceeding 250 V.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60598-2-20:2014 specifies requirements for lighting chains fitted with series, parallel or a combination of series/parallel connected light sources for use either indoors or outdoors on supply voltages not exceeding 250 V. For combinations where rope lights (also known as sealed lighting chains) are included, see IEC 60598-2-21. This fourth edition cancels and replaces the third edition (2010). This edition includes the following significant technical changes with respect to the previous edition, where the requirements for rope lights (sealed lighting chains) have been removed and are now dealt with in IEC 60598-2-21.

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60598-2-22:2014 specifies requirements for emergency luminaires for use with electrical lamps on emergency power supplies not exceeding 1 000 V. This fourth edition cancels and replaces the third edition published in 1997, AMD1:2002 and AMD2:2008. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Clause 22.3, addition of definitions for PELF and Self-contained portable emergency luminaire; b) Clause 22.5, updated with the introduction of requirements for non-replaceable lamp and batteries; c) Clause 22.6, improved requirements to confirm that the charge indication is correctly connected to the circuit together with other clarifications regarding the controlgear and the remote box with its connecting cabe to the emergency luminaire; d) Clause 22.12, improved requirements to ensure that the luminaire shall not become unsafe; e) Clause 22.16, full revision of the photometric testing to align with ISO and CIE; f) Clause 22.17, now only references the requirements which are now covered in IEC 61347 2-7; g) Clause 22.19, now only references the requirements which are now covered in IEC 61347 2-7; h) Annex A, now includes nickel metal hydride batteries and reference to cell types in IEC 61951-1; i) Annex B, minor changes to the classifications; j) Annex C, Figure C.1 deleted in favour of a revised text; k) Annex E, the additional requirements covering self-contained portable emergency luminaires. This publication is to be read in conjunction with IEC 60598-1:2014.

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60598-2-24:2013 series specifies requirements for luminaires intended for use where the necessity of limited temperature on the outer surface exists, due to the risk of thermal effects, combustion or degradation of materials but where the risk of explosion in the atmosphere does not exist. The luminaires are for use with electric light sources on supply voltages not exceeding 1 000 V. This standard specifically excludes requirements for luminaires for use in explosive gas atmospheres and explosive dust atmospheres. This second edition cancels and replaces the first edition published in 1997. It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) change of required degree of protection from IP6X to IP4X to harmonize with the international wiring rules; b) temperature limits introduced for glass surface of any light source exposed to risk of dust.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60598-2-11:2013 specifies requirements for household aquarium luminaires incorporating electric light sources on supply voltages not exceeding 1 000 V. This second edition cancels and replaces the first edition published in 2005. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Subclause 11.1, change of the scope to open the standard for all kinds of electrical light sources. b) Subclause 11.4.2, change of the definition in order to clarify non-permanently attached aquarium luminaire. c) Subclause 11.11.3, for indoor operated aquarium luminaire, change of the size of external cable to at least 0,75 mm2 instead of 1,0 mm2 in the former edition. This publication is to be read in conjunction with IEC 60598-1:2008.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60598-2-8:2013 specifies requirements for handlamps and similar portable luminaires which are held in the hand, hooked up or resting on a surface for use with electric light sources on supply voltages not exceeding 250 V. It is to be read in conjunction with those sections of Part 1 to which reference is made. This third edition cancels and replaces the second edition, published in 1996, its Amendment 1 (2000) and its Amendment 2 (2007). It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition. a) The requirements have been updated to make them consistent and to solve contradicting requirements introduced in the Amendment 2. In that amendment, a requirement was introduced specifying that handlamp shall always be classified as rough service luminaire only. The implication of this statement was that according to 4.13.4 of Part 1 this kind of luminaire shall always be IP54. This requirements is in contradiction with several points of this Part 2 where it is considered acceptable for ordinary luminaires (e.g. 8.11.1, 8.11.2 and 8.13.1). b) Furthermore, the contradiction between the requirement in 8.7.1 and 8.7.2 regarding the type of material used for the protective cover has been corrected.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60598-2-12:2013 specifies requirements for mains socket-outlet mounted nightlights for use with electric light sources, on supply voltages not exceeding 250 V a.c. 50/60 Hz. It is to be read in conjunction with those sections of Part 1 to which reference is made. This second edition cancels and replaces the first edition published in 2006. It constitutes a technical revision for harmonization of thermal tests in 12.13 to relevant parts of 10.12.1 of IEC 60598-2-10.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62034:2012 specifies the basic performance and safety requirements for individual products and components that are incorporated into automatic test systems for use with emergency lighting systems on supply voltages not exceeding 1 000 V. This second edition cancels and replaces the first edition published in 2006. It constitutes a technical revision. The main changes with respect to the first edition are the improvement of the understanding of the requirements in the various clauses and the compliance requirements listed below and the updating of the normative references. - 4.2 Monitoring of the timing circuit - 4.3 Functional requirements - 4.3.1 The automatic test system (ATS) - 4.4.2 Intercommunications failure - 4.4.4 Component failures - 4.4.7 Software failure - 5.1 Functional test - 5.2 Duration test - 6.2.2 Timing accuracy - 6.3.2.2 Testing alternate luminaires - 6.3.3.4 Limited duration test - 7.1 General.

  • Standard
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2012-01-20 - Publication editing allocated to cpalagi@cencenelec.eu

  • Amendment
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2011-12-20 - Publication editing allocated to cpalagi@cencenelec.eu

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60598-2-2:2011 specifies requirements for recessed luminaires incorporating electric light sources for operation from supply voltages up to 1 000 V. This section does not apply to air-handling or liquid-cooled luminaires. This third edition cancels and replaces the second edition published in 1996 and its Amendment 1 (1997), of which is constitutes a technical revision. The changes introduced by this new edition are those required to maintain consistency later versions of IEC 60598-1 that have been published since the previous edition of this standard.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2011-04-22: Publication text allocated to cpalagi@cencenelec.eu .

  • Amendment
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60598-2-14:2009 applies to luminaires for cold cathode tubular discharge lamps and similar equipment, operating on a no-load rated output voltage over 1 000 V but not exceeding 10 000 V, mainly used for general lighting, for indoor or outdoor applications and for supply voltages up to 1 000 V. This publication is intended to be read in conjunction with IEC 60598-1: Luminaires - Part 1: General requirements and tests. It was established on the basis of the seventh edition (2008) of that standard. This publication is intended to be read in conjunction with IEC 60598-1:2008.

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard applies to track systems for ordinary interior use with two or more poles and with provision for earthing (Class 1), with a rated voltage not exceeding 440 V between poles (live conductors), rated frequency not exceeding 60 Hz and a rated current not exceeding 16 A per conductor for the connection of luminaires to the electrical supply.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Specifies requirements for luminaires for road and street lighting, for use with tungsten filament, tubular fluorescent and other discharge lamps on supply voltages not exceeding 1 000 V.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Part 2 of IEC 60598 specifies requirements for ground recessed luminaires incorporating electric light sources for operation from supply voltages up to 1 000 V, for indoor or outdoor use, e.g. in gardens, yards, carriageways, parking lots, cycleways, footways, pedestrian areas, swimming pools areas outside zones for SELV, nurseries and similar applications.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the provision of illumination of escape routes and safety signs in the event of failure of the normal supply, and specifies the minimum provision of such emergency lighting based on the size, type and usage of the premises. This standard relates to the provision of electric emergency escape lighting in all work places and premises open to the public. This European Standard does not cover private domestic premises but its provisions are applicable to common access routes within multi-storey dwellings. This European Standard is also applicable to standby lighting used as emergency escape lighting. There are emerging way guidance techniques that, when applied to escape routes in addition to conventional emergency lighting luminaires, can enhance its effectiveness in an emergency.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Specifies requirements for portable child-appealing luminaires for use with tungsten filament lamps on supply voltages not exceeding 24 V (SELV).

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Details specific requirements for luminaires for use with tungsten filament, fluorescent and other discharge lamps on supply voltages not exceeding 1 000 V for use in clinical areas in which medical treatment, examination and medical care takes place in hospital and health care buildings.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Specifies requirements for fixed luminaires intended for use in water, or in contact with water, for example in swimming pools, fountains, paddling pools, and garden pools, and for use with tungsten filament lamps.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Specifies safety requirements for air-handling luminaires for use with a ventilation space (plenum), for use with tubular fluorescent lamps on supply voltages not exceeding 1 000 V.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60598-1:2024 specifies general safety requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. Requirements for semi-luminaires are included in this document. This tenth edition cancels and replaces the ninth edition published in 2020. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) new structure to comply with the ISO/IEC Directives, Part 2; b) addition of a new Annex V for comparison with the previous edition; c) revision of 7.32 for SPDs and for SPCs; d) the terms "live part" and "active part" were reviewed and aligned with the definitions of "live part" and "hazardous live part" given in IEC 60050-195; e) revision of 7.14.2 for conductor mechanical stress; f) revision of 14.5.2, Item 4 to include controlgear; g) revision of 9.2.1 (Earthing) with the deletion of the word "permanently"; h) revision of Annex N: earth continuity test time; i) revision of 7.11.4; 7.14.1; Table 22 (14.4.3): Introduction of requirements for suspension by magnets; j) addition of a new Annex W for luminaires using batteries; k) clarification of Clause 6 for marking requirements for nature of supply; l) addition of a new Subclause 7.31.5: Additional requirements for luminaires using controllable controlgear providing SELV output(s); m) revision of 6.4.16: Information to be provided for luminaire having protective earth current > 10 mA; n) revision of 6.3.23; 6.4.18; 6.4.24; 7.30 and 10.2.1 for serviceable, non-user serviceable and non-serviceable components; o) revision of Annex D: Draught-proof enclosure; p) revision of 8.2.1 and 13.2.1: Inconsistencies in the inclusion of the limits of voltage ranges; q) revision of 9.2.10 for looping-in; r) Revision of Clause 2 and 7.8: update of the reference to IEC 61058-1-1, IEC 61058-1-2 and IEC 61058­2­1. Update of temperature limits in Table 21 (14.4.3) for luminaires incorporating switches according to IEC 60669-1 or IEC 60669-2-1; s) revision of 6.3.22 and 7.24 for photobiological safety; t) addition of a new Subclause 6.3.27 for marking of mains socket outlet moved from information requirements.

  • Draft
    257 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60598-1:2014 specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. The requirements and related tests of this standard cover: classification, marking, mechanical construction, electrical construction and photobiological safety. This eighth edition cancels and replaces the seventh edition published in 2008. This edition constitutes a technical revision and includes the following significant technical changes with respect to the previous edition: a) requirements to support the construction methods for new LED luminaires entering the market; b) photobiological requirements extended; c) more precise requirements for insulation between different types of electrical circuit; d) other general updates and improvements.

  • Standard
    216 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard specifies the basic performance and safety requirements for individual products and components that are incorporated into automatic test systems for use with emergency lighting systems on supply voltages not exceeding 1000 V.

  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60598-2-20:2010 specifies requirements for lighting chains fitted with series- or parallel- or a combination of series/parallel-connected incandescent lamps for use either indoors or outdoors on supply voltages not exceeding 250 V. This third edition cancels and replaces the second edition published in 1996, its Amendment 1 (1998), its Amendment 2 (2002) and the interpretation sheets of March 2001 (1) and July 2003 (2 and 3). This third edition is based on the second edition, its Amendments 1 and 2 and the interpretation sheets of March 2001 (1) and July 2003 (2 and 3) and incorporates some changes relating to 20.7.15. This third edition constitutes a minor revision. This publication is intended to be read in conjunction with IEC 60598-1: Luminaires - Part 1: General requirements and tests. It was established on the basis of the seventh edition (2008) of that standard.

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60598-1:2008 specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. The requirements and related tests of this standard cover: classification, marking, mechanical construction and electrical construction. This seventh edition cancels and replaces the sixth edition published in 2003. It constitutes a technical revision. The major changes which may affect certification are given in Annex R. Annex R shows where a new text has been included which contains more serious/critical requirements requiring products to be re-tested. Subclauses 1.2.71, 3.2.19, 4.21, 4.24, Annex P: Requirements self shielded lamps and UV protection. Subclauses 1.2.42, 5.2.14, 5.2.16, 8.2.3, 9.2: SELV requirements. Subclauses 1.2.78, 1.2.79, 1.2.80, 3.3, 10.1, 10.3, Annex G: Touch current, protective current and electric burn. Subclauses 1.2.81, 1.2.82, 3.2.20, 4.14.3, Table 12.1: Hot surfaces. Subclauses 0.5.2, 1.2.83, Annex V: Terminal block with integrated earthing contact. Subclauses 3.2.22, Figure 1: replaceable fuses. Subclauses 1.2.8, 8.2.1, 8.2.4, 8.2.5, 8.2.6: Access to basic insulation of luminaries. Subclauses 2.4, 12.6, 3.2.9, 3.2.21, 4.16, Annex D, Annex N: Marking of luminaires not suitable for mounting on normally flammable surfaces and covering with insulation. Subclause 4.12.4: Torque requirements for lampholders with a single means of fixing exposed to a rotary action. Subclause 9.2: Requirements for protection of lamp splashing.

  • Standard
    204 pages
    English language
    sale 10% off
    e-Library read for
    1 day