Explosive atmospheres - Part 10-1: Classification of areas - Explosive gas atmospheres

IEC 60079-10-1:2008 is concerned with the classification of areas where flammable gas or vapour or mist hazards may arise and may then be used as a basis to support the proper selection and installation of equipment for use in a hazardous area. It is intended to be applied where there may be an ignition hazard due to the presence of flammable gas or vapour, mixed with air under normal atmospheric conditions, but it does not apply to a) mines susceptible to firedamp; b) the processing and manufacture of explosives; c) areas where a hazard may arise due to the presence of combustible dusts or fibres; d) catastrophic failures which are beyond the concept of abnormality; e) rommos used for medial purposes; f) domestic premises. This first edition of IEC 60079-10-1 cancels and replaces the fourth edition of IEC 60079-10, published in 2002, and constitutes a technical revision. The significant technical changes with respect to the previous edition are: - introduction of Annex D which deals with explosion hazard from flammable mists generated by the release under pressure of high flash point liquids; - introduction of Clause A.3 (release rate) which gives thermodynamic equations for release rate with a number of examples for estimating release rate of fluids and gases.

Explosionsfähige Atmosphäre - Teil 10-1: Einteilung der Bereiche - Gasexplosionsgefährdete Bereiche

Atmosphères explosives - Partie 10-1: Classement des emplacements - Atmosphères explosives gazeuses

La CEI 60079-10-1:2008 est relative au classement des emplacements dans lesquels des risques dus à des gaz, vapeurs ou brouillards inflammables peuvent apparaître, et ainsi constituer une base pour le choix et l'installation corrects du matériel utilisé dans de tels emplacements. Elle est destinée à être appliquée là où il peut exister un danger d'inflammation du fait de la présence de gaz ou vapeurs inflammables, en mélange avec l'air, dans les conditions atmosphériques normales; mais elle ne s'applique pas: a) aux mines grisouteuses; b) au traitement et à la fabrication des explosifs; c) aux emplacements dans lesquels un danger dû à la présence de poussières ou fibres inflammables peut apparaître; d) aux défaillances catastrophiques, qui dépassent le concept d'anormalité traité dans la présente norme; e) aux locaux utilisés à des fins médicales; f) aux locaux à usage domestique. Cette première édition de la CEI 60079-10-1 annule et remplace la quatrième édition de la CEI 60079-10, publiée en 2002, et constitue une révision technique. Les principales modifications techniques suivantes ont été apportées par rapport à l'édition précédente: - introduction de l'Annexe D qui traite du danger d'explosion du brouillard inflammable généré par l'échappement sous pression de liquides au point d'éclair élevé; - introduction de l'Article A.3 (taux de dégagement) qui donne des équations thermodynamiques pour le taux de dégagement avec des exemples pour l'estimation du taux de dégagement des fluides et de gaz.

Eksplozivne atmosfere - 10-1. del: Razvrstitev prostorov - Eksplozivne plinske atmosfere (IEC 60079-10-1:2008)

General Information

Status
Withdrawn
Publication Date
25-Mar-2009
Withdrawal Date
29-Feb-2012
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
13-Oct-2018
Completion Date
13-Oct-2018

Relations

Buy Standard

Standard
EN 60079-10-1:2009 (EN)
English language
69 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Standard
EN 60079-10-1:2009 (FR)
French language
75 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 60079-10-1:2009
01-september-2009
1DGRPHãþD
SIST EN 60079-10:2003
Eksplozivne atmosfere - 10-1. del: Razvrstitev prostorov - Eksplozivne plinske
atmosfere (IEC 60079-10-1:2008)
Explosive atmospheres -- Part 10-1: Classification of areas - Explosive gas atmospheres
Explosionsfähige Atmosphäre – Teil 10-1: Einteilung der Bereiche –
Gasexplosionsgefährdete Bereiche
Atmosphères explosives -- Partie 10-1: Classement des emplacements - Atmosphères
explosives gazeuses
Ta slovenski standard je istoveten z: EN 60079-10-1:2009
ICS:
29.260.20 (OHNWULþQLDSDUDWL]D Electrical apparatus for
HNVSOR]LYQDR]UDþMD explosive atmospheres
SIST EN 60079-10-1:2009 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 60079-10-1:2009

---------------------- Page: 2 ----------------------

SIST EN 60079-10-1:2009

EUROPEAN STANDARD
EN 60079-10-1

NORME EUROPÉENNE
March 2009
EUROPÄISCHE NORM

ICS 29.260.20 Supersedes EN 60079-10:2003


English version


Explosive atmospheres -
Part 10-1: Classification of areas -
Explosive gas atmospheres
(IEC 60079-10-1:2008)


Atmosphères explosives -  Explosionsfähige Atmosphäre -
Partie 10-1: Classement Teil 10-1: Einteilung der Bereiche -
des emplacements - Gasexplosionsgefährdete Bereiche
Atmosphères explosives gazeuses (IEC 60079-10-1:2008)
(CEI 60079-10-1:2008)




This European Standard was approved by CENELEC on 2009-03-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: avenue Marnix 17, B - 1000 Brussels


© 2009 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60079-10-1:2009 E

---------------------- Page: 3 ----------------------

SIST EN 60079-10-1:2009
EN 60079-10-1:2009 - 2 -
Foreword
The text of document 31J/159/FDIS, future edition 1 of IEC 60079-10-1, prepared by SC 31J,
Classification of hazardous areas and installation requirements, of IEC TC 31, Equipment for explosive
atmospheres, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as
EN 60079-10-1 on 2009-03-01.
This European Standard supersedes EN 60079-10:2003.
The significant technical changes with respect to EN 60079-10:2003 are as follows:
– introduction of Annex D which deals with explosion hazard from flammable mists generated by the
release under pressure of high flash point liquids;
– introduction of Clause A.3 (release rate) which gives thermodynamic equations for release rate with a
number of examples for estimating release rate of fluids and gases.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2009-12-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2012-03-01
Annexes ZA and ZB have been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 60079-10-1:2008 was approved by CENELEC as a European
Standard without any modification.
__________

---------------------- Page: 4 ----------------------

SIST EN 60079-10-1:2009
- 3 - EN 60079-10-1:2009
Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications

The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.

NOTE  When an international publication has been modified by common modific
...

SLOVENSKI STANDARD
SIST EN 60079-10-1:2009
01-september-2009
1DGRPHãþD
SIST EN 60079-10:2003
Eksplozivne atmosfere - 10-1. del: Razvrstitev prostorov - Eksplozivne plinske
atmosfere (IEC 60079-10-1:2008)
Explosive atmospheres -- Part 10-1: Classification of areas - Explosive gas atmospheres
Explosionsfähige Atmosphäre – Teil 10-1: Einteilung der Bereiche –
Gasexplosionsgefährdete Bereiche
Atmosphères explosives -- Partie 10-1: Classement des emplacements - Atmosphères
explosives gazeuses
Ta slovenski standard je istoveten z: EN 60079-10-1:2009
ICS:
29.260.20 (OHNWULþQLDSDUDWL]D Electrical apparatus for
HNVSOR]LYQDR]UDþMD explosive atmospheres
SIST EN 60079-10-1:2009 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 60079-10-1:2009

---------------------- Page: 2 ----------------------

SIST EN 60079-10-1:2009

NORME EUROPÉENNE
EN 60079-10-1

EUROPÄISCHE NORM
Mars 2009
EUROPEAN STANDARD

ICS 29.260.20 Remplace EN 60079-10:2003


Version française


Atmosphères explosives -
Partie 10-1: Classement des emplacements -
Atmosphères explosives gazeuses
(CEI 60079-10-1:2008)


Explosionsfähige Atmosphäre -  Explosive atmospheres -
Teil 10-1: Einteilung der Bereiche - Part 10-1: Classification of areas -
Gasexplosionsgefährdete Bereiche Explosive gas atmospheres
(IEC 60079-10-1:2008) (IEC 60079-10-1:2008)




La présente Norme Européenne a été adoptée par le CENELEC le 2009-03-01. Les membres du CENELEC
sont tenus de se soumettre au Règlement Intérieur du CEN/CENELEC qui définit les conditions dans lesquelles
doit être attribué, sans modification, le statut de norme nationale à la Norme Européenne.

Les listes mises à jour et les références bibliographiques relatives à ces normes nationales peuvent être
obtenues auprès du Secrétariat Central ou auprès des membres du CENELEC.

La présente Norme Européenne existe en trois versions officielles (allemand, anglais, français). Une version
dans une autre langue faite par traduction sous la responsabilité d'un membre du CENELEC dans sa langue
nationale, et notifiée au Secrétariat Central, a le même statut que les versions officielles.

Les membres du CENELEC sont les comités électrotechniques nationaux des pays suivants: Allemagne,
Autriche, Belgique, Bulgarie, Chypre, Danemark, Espagne, Estonie, Finlande, France, Grèce, Hongrie, Irlande,
Islande, Italie, Lettonie, Lituanie, Luxembourg, Malte, Norvège, Pays-Bas, Pologne, Portugal, République
Tchèque, Roumanie, Royaume-Uni, Slovaquie, Slovénie, Suède et Suisse.

CENELEC
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
European Committee for Electrotechnical Standardization

Secrétariat Central: avenue Marnix 17, B - 1050 Bruxelles


© 2009 CENELEC - Tous droits d'exploitation sous quelque forme et de quelque manière que ce soit réservés dans le monde entier aux
membres du CENELEC.
Ref. n° EN 60079-10-1:2009 F

---------------------- Page: 3 ----------------------

SIST EN 60079-10-1:2009
EN 60079-10-1:2009 - 2 -
Avant-propos
Le texte du document 31J/159/FDIS, future édition 1 de la CEI 60079-10-1, préparé par le SC 31J,
Classification des emplacements dangereux et règles d'installation, du CE 31 de la CEI, Equipements
pour atmosphères explosives, a été soumis au vote parallèle CEI-CENELEC et a été approuvé par le
CENELEC comme EN 60079-10-1 le 2009-03-01.
Cette Norme Européenne remplace la EN 60079-10:2003.
Les principales modifications techniques suivantes ont été apportées par rapport à la EN 60079-10:2003:
– introduction de l’Annexe D qui traite du danger d’explosion du brouillard inflammable généré par
l’échappement sous pression de liquides au point d’éclair élevé;
– introduction de l’Article A.3 (taux de dégagement) qui donne des équations thermodynamiques pour le
taux de dégagement avec des exemples pour l’estimation du taux de dégagement des fluides et de
gaz.
Les dates suivantes ont été fixées:
– date limite à laquelle la EN doit être mise en application
au niveau national par publication d'une norme
nationale identique ou par entérinement (dop) 2009-12-01
– date limite à laquelle les normes nationales
conflictuelles doivent être annulées (dow) 2012-03-01
Les Annexes ZA et ZB ont été ajoutées par le CENELEC.
__________
Notice d’entérinement
Le texte de la Norme internationale CEI 60079-10-1:2008 a été approuvé par le CENELEC comme
Norme Européenne sans aucune modification.
__________

---------------------- Page: 4 ----------------------

SIST EN 60079-10-1:2009
- 3 - EN 60079-10-1:2009
Annexe ZA
(normative)

Références normatives à d'autres publications internationales
avec les publications européennes correspondantes

Les documents de référence suivants sont indispensables pour l'application du prés
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.