Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet 283: Heat-shrinkable, polyolefin sleeving for bus-bar insulation

IEC 60684-3-283:2010 gives the requirements for two types of heat-shrinkable, polyolefin sleeving for bus-bar insulation, with a nominal shrink ratio of 2,5:1. This sleeving has been found suitable up to temperatures of 100 °C.
- Type A: Medium wall Internal diameter up to 170,0 mm typically
- Type B: Thick wall Internal diameter up to 165,0 mm typically.

Gaines isolantes souples - Partie 3: Spécifications pour types particuliers de gaines - Feuille 283: Gaines thermorétractables, en polyoléfine pour isolation de barre omnibus

La CEI 60684-3-283:2010 donne les exigences relatives à deux types de gaines thermorétractables, en polyoléfine, pour isolation des barres omnibus de rapport de rétreint nominal 2,5:1. Ces gaines se sont révélées être adaptées à des températures jusqu'à 100 °C.
- Type A: Paroi moyenne Diamètre intérieur type jusqu'à 170,0 mm
- Type B: Paroi épaisse Diamètre intérieur type jusqu'à 165,0 mm.

General Information

Status
Published
Publication Date
08-Dec-2010
Current Stage
DELPUB - Deleted Publication
Start Date
20-Aug-2019
Completion Date
12-Oct-2018
Ref Project

Relations

Standard
IEC 60684-3-283:2010 - Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet 283: Heat-shrinkable, polyolefin sleeving for bus-bar insulation Released:12/9/2010
English and French language
21 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
IEC 60684-3-283:2010+AMD1:2013 CSV - Flexible insulating sleeving - Part 3: Specifications for individualtypes of sleeving - Sheet 283: Heat-shrinkable, polyolefin sleeving for bus-bar insulation Released:12/12/2013 Isbn:9782832213100
English and French language
49 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


IEC 60684-3-283 ®
Edition 1.0 2010-12
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Flexible insulating sleeving –
Part 3: Specifications for individual types of sleeving – Sheet 283: Heat-
shrinkable, polyolefin sleeving for bus-bar insulation

Gaines isolantes souples –
Partie 3: Spécifications pour types particuliers de gaines – Feuille 283: Gaines
thermorétractables en polyoléfine pour isolation de barre omnibus

All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by

any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or

IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,

please contact the address below or your local IEC member National Committee for further information.

Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie

et les microfilms, sans l'accord écrit de la CEI ou du Comité national de la CEI du pays du demandeur.

Si vous avez des questions sur le copyright de la CEI ou si vous désirez obtenir des droits supplémentaires sur cette

publication, utilisez les coordonnées ci-après ou contactez le Comité national de la CEI de votre pays de résidence.

IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
 Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
 IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
 Electropedia: www.electropedia.org
The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions
in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical
Vocabulary online.
 Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
A propos de la CEI
La Commission Electrotechnique Internationale (CEI) est la première organisation mondiale qui élabore et publie des
normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.

A propos des publications CEI
Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possédez
l’édition la plus récente, un corrigendum ou amendement peut avoir été publié.
 Catalogue des publications de la CEI: www.iec.ch/searchpub/cur_fut-f.htm
Le Catalogue en-ligne de la CEI vous permet d’effectuer des recherches en utilisant différents critères (numéro de référence,
texte, comité d’études,…). Il donne aussi des informations sur les projets et les publications retirées ou remplacées.
 Just Published CEI: www.iec.ch/online_news/justpub
Restez informé sur les nouvelles publications de la CEI. Just Published détaille deux fois par mois les nouvelles
publications parues. Disponible en-ligne et aussi par email.
 Electropedia: www.electropedia.org
Le premier dictionnaire en ligne au monde de termes électroniques et électriques. Il contient plus de 20 000 termes et
définitions en anglais et en français, ainsi que les termes équivalents dans les langues additionnelles. Egalement appelé
Vocabulaire Electrotechnique International en ligne.
 Service Clients: www.iec.ch/webstore/custserv/custserv_entry-f.htm
Si vous désirez nous donner des commentaires sur cette publication ou si vous avez des questions, visitez le FAQ du
Service clients ou contactez-nous:
Email: csc@iec.ch
Tél.: +41 22 919 02 11
Fax: +41 22 919 03 00
IEC 60684-3-283 ®
Edition 1.0 2010-12
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Flexible insulating sleeving –
Part 3: Specifications for individual types of sleeving – Sheet 283: Heat-
shrinkable, polyolefin sleeving for bus-bar insulation

Gaines isolantes souples –
Partie 3: Spécifications pour types particuliers de gaines – Feuille 283: Gaines
thermorétractables en polyoléfine pour isolation de barre omnibus

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
L
CODE PRIX
ICS 29.035.20 ISBN 978-2-88912-295-0
– 2 – 60684-3-283  IEC:2010
CONTENTS
F OREW O R D . 3

INTRODUCTION . 5

1 Scope . 6

2 Normative references . 6

3 Designation . 7

4 Conditions of test . 7

5 Requirements . 7

6 Sleeving conformance . 7
Annex A (informative) Guidance to the available sizes and wall thicknesses . 11

Table 1 – Property requirements . 8
Table 2 – Requirements for dielectric strength . 9
Table 3 – Resistance to selected fluids . 9
Table 4 – Additional property requirements . 10
Table A.1 – Type A, medium wall . 11
Table A.2 – Type B, thick wall . 11

60684-3-283  IEC:2010 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION

___________
FLEXIBLE INSULATING SLEEVING –

Part 3: Specifications for individual types of sleeving –

Sheet 283: Heat-shrinkable, polyolefin sleeving for bus-bar insulation

FOREWORD
1) The International Electro-technical Commission (IEC) is a worldwide organization for standardization
comprising all national electro-technical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.

International Standard IEC 60684-3-283 has been prepared by IEC technical committee 15:
Solid electrical insulating materials.
The text of this standard is based on the following documents:
FDIS Report on voting
15/597/FDIS 15/605/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all the parts in the IEC 60684 series, under the general title Flexible insulating
sleeving, can be found on the IEC website.

– 4 – 60684-3-283  IEC:2010
The committee has decided that the contents of this publication will remain unchanged until

the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data

related to the specific publication. At this date, the publication will be

• reconfirmed,
• withdrawn,
• replaced by a revised edition, or

• amended.
60684-3-283  IEC:2010 – 5 –
INTRODUCTION
This International Standard is one of a series which deals with flexible insulating sleeving for

electrical purposes.
The series consists of three parts:

Part 1: Definitions and general requirements (IEC 60684-1)

Part 2: Methods of test (IEC 60684-2)

Part 3: Specifications for individual types of sleeving (IEC 60684-3)

This standard comprises one of the sheets of Part 3:
Sheet 283: Heat-shrinkable, polyolefin sleeving for bus-bar insulation.

– 6 – 60684-3-283  IEC:2010
FLEXIBLE INSULATING SLEEVING –

Part 3: Specifications for individual types of sleeving –

Sheet 283: Heat-shrinkable, polyolefin sleeving for bus-bar insulation

1 Scope
This part of IEC 60684 gives the requirements for two types of heat-shrinkable, polyolefin
sleeving for bus-bar insulation, with a nominal shrink ratio of 2,5:1.
This sleeving has been found suitable up to temperatures of 100 °C.
– Type A : Medium wall Internal diameter up to 170,0 mm typically
– Type B : Thick wall Internal diameter up to 165,0 mm typically
These sleevings are normally supplied in colour, red or brown.
Since these types of sleevings cover a significantly large range of sizes and wall thicknesses,
Tables A.1 and A.2 provide guidance to the range of sizes available. The actual size and wall
thickness shall be agreed between the user and supplier depending on the electric strength of
the installed tubing offered and the requirements of the user.
Materials which conform to this specification meet established levels of performance.
However, the selection of a material by a user for a specific application should be based on
the actual requirements necessary for adequate performance in that application and not
based on this specification alone.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 60296:2003, Fluids for electrotechnical applications – Unused mineral insulating oils for
transformers and switchgear
IEC 60684-1:2003, Flexible insulating sleeving – Part 1: Definitions and general requirements
IEC 60684-2:1997, Flexible insulating sleeving – Part 2: Methods of test
Amendment 1 (2003)
Amendment 2 (2005)
IEC 60757:1983, Code for designation of colours
ISO 846:1997, Plastics – Evaluation of the action of microorganisms
ISO 4892-3:2006, Plastics – Methods of exposure to laboratory light sources – Part 3:
Fluorescent UV lamps
60684-3-283  IEC:2010 – 7 –
3 Designation
The sleeving shall be identified by the following designation:

a
Description IEC publication IEC part IEC sheet Type Size Colour
Table 4
number number number
code
(expanded and
recovered internal
diameter in
millimetres)
       
Sleeving IEC 60684 - 3 -283 A - 75,0/30,0 -Red X
a
The addition of “X” at the end of the designation indicates that the properties contained in Table 4 have been agreed upon
between the user and the supplier.
Any colour abbreviation shall comply with IEC 60757, where applicable. Non-standard colours
shall be written out in full.
NOTE This is for package labelling only in accordance with IEC 60684-1.
4 Conditions of test
Unless otherwise specified, the sleeving shall be shrunk in a forced air circulation oven for
(10  1) min at 200 °C  3 K prior to testing.
5 Requirements
In addition to the general requirements given in IEC 60684-1, the sleeving shall comply with
the requirements of Tables 1, 2, 3, and 4 where applicable.
6 Sleeving conformance
Conformance to the requirements of this specification shall normally be based on the results
from typical sizes.
– Type A : Recovered ID 25 mm - 30 mm
– Type B : Recovered ID 25 mm - 40 mm

– 8 – 60684-3-283  IEC:2010
Table 1 – Property requirements

Property IEC 60684-2 Units Max. Requirements Remarks

clause or or
subclause min.
Dimensions 3
– Internal diameter 3.1.2 mm To be agreed
– Wall thickness 3.3.2 mm between the purchaser
– Concentricity 3.3.3 % and the supplier

– expanded Min. 60
– recovered Min. 85
Heat shock 6  Heat at
Tensile strength 19.1 and 19.2 MPa Min. 5 150 C  5 K
Elongation at break 19.1 and 19.2 % Min. 200
Longitudinal 9 % Max. –10
change +5
Bending at low 14 – – No cracking Test at –40 C
temperature shall be visible.
For strips, the mandrel
shall be between 20
and 22 times the wall
thickness. Full section
sleeving is tested
unfilled and the mandrel
shall be between 20
and 22 times the outer
diameter.
Dimensional 16 – – The dimensions shall See Scope.
stability on storage remain as agreed.
Tensile strength 19.1 and 19.2 MPa Min. 8 Use a jaw
400 separation rate
Elongation at break 19.1 and 19.2 % Min.
of 100 mm/min.
Secant modulus 19.4 MPa Max. 160
at 2 % elongation
Dielectric strength 21 kV/mm Min. See Table 2.
Volume resistivity 23 ·m Min. 10
at room temperature 23.4.2
Flame propagation 26 s Max. 60 Burning includes
Method C mm Max. 100 flaming and glowing
Corrosion resistance 32 % Min. No chemical
Heat at 150 C  3 K
interaction
Elongation 19.1 and
19.2
Resistance to 36 MPa Min. 5 Use the fluids and test
selected fluids % Min. 200 temperatures specified
in Table 3.
Tensile strength 19.1 and 19.2
Immersion (24  1)h
Elongation at break 19.1 and 19.2
Heat ageing 39 MPa Min. 5 Heat at 150 °C  3 K
% Min. 200
Tensile strength 19.1 and 19.2

Elongation at break 19.1 and 19.2
Long term ageing 50 % Min. 150 The ageing temperature
19.2
shall be 100 °C  3 K.
Elongation at break
60684-3-283  IEC:2010 – 9 –
Table 2 – Requirements for dielectric strength

a
Expanded wall thickness
Dielectric strength
mm
Min.
All dimensions Expanded ID Dielectric strength kV/mm

Types A+B
All sizes 12
a
Measure the expanded wall thickness and calculate the electric strength by dividing the

breakdown voltage by this value.

NOTE Care should be taken on selection of sizes based on these values. Refer to the
manufacturer for actual values on installed conditions.

The breakdown voltage shall be determined by the method described in 21 of IEC 60684-2.
All values shall comply with the minimum value in this table.
The sleeving shall be tested in the expanded condition.
The rate of application of the voltage shall be 500 V/s.
Table 3 – Resistance to selected fluids
Test Fluids Type Standard or symbol Immersion temperature
fluid
C  2 K
No.
1 Insulating oil Mineral based IEC 60296 23
2 Cleaning fluid Solvent Isopropyl alcohol 23
3 - Water De-ionized 85
Other fluids and/or temperatures may be specified for customers with specific needs. These
additional fluids and/or temperatures shall be applicable when incorporated into agreements
between the supplier and the customer.

– 10 – 60684-3-283  IEC:2010
Table 4 – Additi
...


IEC 60684-3-283 ®
Edition 1.1 2013-12
CONSOLIDATED
VERSION
VERSION
CONSOLIDÉE
colour
inside
Flexible insulating sleeving –
Part 3: Specifications for individual types of sleeving – Sheet 283: Heat-
shrinkable, polyolefin sleeving for bus-bar insulation

Gaines isolantes souples –
Partie 3: Spécifications pour types particuliers de gaines – Feuille 283: Gaines
thermorétractables en polyoléfine pour isolation de barre omnibus

All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form

or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,

please contact the address below or your local IEC member National Committee for further information.

Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite ni
utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les

microfilms, sans l'accord écrit de la CEI ou du Comité national de la CEI du pays du demandeur.

Si vous avez des questions sur le copyright de la CEI ou si vous désirez obtenir des droits supplémentaires sur cette

publication, utilisez les coordonnées ci-après ou contactez le Comité national de la CEI de votre pays de résidence.

IEC Central Office Tel.: +41 22 919 02 11
3, rue de Varembé Fax: +41 22 919 03 00
CH-1211 Geneva 20 info@iec.ch
Switzerland www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.

Useful links:
IEC publications search - www.iec.ch/searchpub Electropedia - www.electropedia.org
The advanced search enables you to find IEC publications The world's leading online dictionary of electronic and
by a variety of criteria (reference number, text, technical electrical terms containing more than 30 000 terms and
committee,…). definitions in English and French, with equivalent terms in
It also gives information on projects, replaced and additional languages. Also known as the International
withdrawn publications. Electrotechnical Vocabulary (IEV) on-line.

IEC Just Published - webstore.iec.ch/justpublished Customer Service Centre - webstore.iec.ch/csc
Stay up to date on all new IEC publications. Just Published If you wish to give us your feedback on this publication
details all new publications released. Available on-line and or need further assistance, please contact the
also once a month by email. Customer Service Centre: csc@iec.ch.

A propos de la CEI
La Commission Electrotechnique Internationale (CEI) est la première organisation mondiale qui élabore et publie des
Normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.

A propos des publications CEI
Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possédez
l’édition la plus récente, un corrigendum ou amendement peut avoir été publié.

Liens utiles:
Recherche de publications CEI - www.iec.ch/searchpub Electropedia - www.electropedia.org
La recherche avancée vous permet de trouver des Le premier dictionnaire en ligne au monde de termes
publications CEI en utilisant différents critères (numéro de électroniques et électriques. Il contient plus de 30 000
référence, texte, comité d’études,…). termes et définitions en anglais et en français, ainsi que
Elle donne aussi des informations sur les projets et les les termes équivalents dans les langues additionnelles.
publications remplacées ou retirées. Egalement appelé Vocabulaire Electrotechnique
International (VEI) en ligne.
Just Published CEI - webstore.iec.ch/justpublished
Service Clients - webstore.iec.ch/csc
Restez informé sur les nouvelles publications de la CEI.
Just Published détaille les nouvelles publications parues. Si vous désirez nous donner des commentaires sur
Disponible en ligne et aussi une fois par mois par email. cette publication ou si vous avez des questions
contactez-nous: csc@iec.ch.
IEC 60684-3-283 ®
Edition 1.1 2013-12
CONSOLIDATED
VERSION
VERSION
CONSOLIDÉE
colour
inside
Flexible insulating sleeving –

Part 3: Specifications for individual types of sleeving – Sheet 283: Heat-

shrinkable, polyolefin sleeving for bus-bar insulation

Gaines isolantes souples –
Partie 3: Spécifications pour types particuliers de gaines – Feuille 283: Gaines

thermorétractables en polyoléfine pour isolation de barre omnibus

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 29.035.20 ISBN 978-2-8322-1310-0

IEC 60684-3-283 ®
Edition 1.1 2013-12
REDLINE VERSION
VERSION REDLINE
colour
inside
Flexible insulating sleeving –
Part 3: Specifications for individual types of sleeving – Sheet 283: Heat-
shrinkable, polyolefin sleeving for bus-bar insulation

Gaines isolantes souples –
Partie 3: Spécifications pour types particuliers de gaines – Feuille 283: Gaines
thermorétractables en polyoléfine pour isolation de barre omnibus

– 2 – 60684-3-283  IEC:2010+A1:2013

CONTENTS
FOREWORD . 3

INTRODUCTION . 5

INTRODUCTION TO THE AMENDMENT . 6

1 Scope . 7

2 Normative references . 7

3 Designation . 8

4 Conditions of test . 8
5 Requirements . 8
6 Sleeving conformance . 8
Annex A (informative) Guidance to the available sizes and wall thicknesses . 12

Table 1 – Property requirements . 9
Table 2 – Requirements for dielectric strength . 10
Table 3 – Resistance to selected fluids . 10
Table 4 – Additional property requirements . 11
Table A.1 – Type A, medium wall . 12
Table A.2 – Type B, thick wall . 12

60684-3-283  IEC:2010+A1:2013 – 3 –

INTERNATIONAL ELECTROTECHNICAL COMMISSION

___________
FLEXIBLE INSULATING SLEEVING –

Part 3: Specifications for individual types of sleeving –

Sheet 283: Heat-shrinkable, polyolefin sleeving for bus-bar insulation

FOREWORD
1) The International Electro-technical Commission (IEC) is a worldwide organization for standardization
comprising all national electro-technical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.

This Consolidated version of IEC 60684-3-283 bears the edition number 1.1. It consists
of the first edition (2010) [documents 15/597/FDIS and 15/605/RVD] and its amendment 1
(2013) [documents 15/687/CDV and 15/704/RVC]. The technical content is identical to
the base edition and its amendment.
In this Redline version, a vertical line in the margin shows where the technical content
is modified by amendment 1. Additions and deletions are displayed in red, with
deletions being struck through. A separate Final version with all changes accepted is
available in this publication.
This publication has been prepared for user convenience.

– 4 – 60684-3-283  IEC:2010+A1:2013

International Standard IEC 60684-3-283 has been prepared by IEC technical committee 15:
Solid electrical insulating materials.

This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.

A list of all the parts in the IEC 60684 series, under the general title Flexible insulating
sleeving, can be found on the IEC website.

The committee has decided that the contents of the base publication and its amendment will

remain unchanged until the stability date indicated on the IEC web site under

"http://webstore.iec.ch" in the data related to the specific publication. At this date, the

publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
IMPORTANT – The “colour inside” logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct understanding
of its contents. Users should therefore print this publication using a colour printer.

60684-3-283  IEC:2010+A1:2013 – 5 –

INTRODUCTION
This International Standard is one of a series which deals with flexible insulating sleeving for

electrical purposes.
The series consists of three parts:

Part 1: Definitions and general requirements (IEC 60684-1)

Part 2: Methods of test (IEC 60684-2)

Part 3: Specifications for individual types of sleeving (IEC 60684-3)

This standard comprises one of the sheets of Part 3:
Sheet 283: Heat-shrinkable, polyolefin sleeving for bus-bar insulation.

– 6 – 60684-3-283  IEC:2010+A1:2013

INTRODUCTION TO THE AMENDMENT
This amendment changes the test method for resistance to weathering since it is quoted

incorrectly as ISO 4892-3 method 1 .This method does not exist in the 2006 edition of

ISO 4892-3. Also after consulting with users of these types of sleevings it was decided that a

period of 3 000 hours exposure to this method was adequate.

60684-3-283  IEC:2010+A1:2013 – 7 –

FLEXIBLE INSULATING SLEEVING –

Part 3: Specifications for individual types of sleeving –

Sheet 283: Heat-shrinkable, polyolefin sleeving for bus-bar insulation

1 Scope
This part of IEC 60684 gives the requirements for two types of heat-shrinkable, polyolefin
sleeving for bus-bar insulation, with a nominal shrink ratio of 2,5:1.
This sleeving has been found suitable up to temperatures of 100 °C.
– Type A : Medium wall Internal diameter up to 170,0 mm typically
– Type B : Thick wall Internal diameter up to 165,0 mm typically
These sleevings are normally supplied in colour, red or brown.
Since these types of sleevings cover a significantly large range of sizes and wall thicknesses,
Tables A.1 and A.2 provide guidance to the range of sizes available. The actual size and wall
thickness shall be agreed between the user and supplier depending on the electric strength of
the installed tubing offered and the requirements of the user.
Materials which conform to this specification meet established levels of performance.
However, the selection of a material by a user for a specific application should be based on
the actual requirements necessary for adequate performance in that application and not
based on this specification alone.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 60296:2003, Fluids for electrotechnical applications – Unused mineral insulating oils for
transformers and switchgear
IEC 60684-1:2003, Flexible insulating sleeving – Part 1: Definitions and general requirements
IEC 60684-2:1997, Flexible insulating sleeving – Part 2: Methods of test
Amendment 1 (2003)
Amendment 2 (2005)
IEC 60757:1983, Code for designation of colours
ISO 846:1997, Plastics – Evaluation of the action of microorganisms
ISO 4892-3:2006, Plastics – Methods of exposure to laboratory light sources – Part 3:
Fluorescent UV lamps
– 8 – 60684-3-283  IEC:2010+A1:2013

3 Designation
The sleeving shall be identified by the following designation:

a
Description IEC publication IEC part IEC sheet Type Size Colour
Table 4
number number number
code
(expanded and
recovered internal
diameter in
millimetres)
↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓
Sleeving IEC 60684 - 3 -283 A - 75,0/30,0 -Red X
a
The addition of “X” at the end of the designation indicates that the properties contained in Table 4 have been agreed upon
between the user and the supplier.
Any colour abbreviation shall comply with IEC 60757, where applicable. Non-standard colours
shall be written out in full.
NOTE This is for package labelling only in accordance with IEC 60684-1.
4 Conditions of test
Unless otherwise specified, the sleeving shall be shrunk in a forced air circulation oven for
(10 ± 1) min at 200 °C ± 3 K prior to testing.
5 Requirements
In addition to the general requirements given in IEC 60684-1, the sleeving shall comply with
the requirements of Tables 1, 2, 3, and 4 where applicable.
6 Sleeving conformance
Conformance to the requirements of this specification shall normally be based on the results
from typical sizes.
– Type A : Recovered ID 25 mm - 30 mm
– Type B : Recovered ID 25 mm - 40 mm

60684-3-283  IEC:2010+A1:2013 – 9 –

Table 1 – Property requirements

Property IEC 60684-2 Units Max. Requirements Remarks

clause or or
subclause min.
Dimensions 3
– Internal diameter 3.1.2 mm To be agreed
– Wall thickness 3.3.2 mm between the purchaser
– Concentricity 3.3.3 % and the supplier

– expanded Min. 60
– recovered Min. 85
Heat shock 6  Heat at
Tensile strength 19.1 and 19.2 MPa Min. 5 150 °C ± 5 K
Elongation at break 19.1 and 19.2 % Min. 200
Longitudinal 9 % Max. –10
change +5
Bending at low 14 – – No cracking Test at –40 °C
temperature shall be visible.
For strips, the mandrel
shall be between 20
and 22 times the wall
thickness. Full section
sleeving is tested
unfilled and the mandrel
shall be between 20
and 22 times the outer
diameter.
Dimensional 16 – – The dimensions shall See Scope.
stability on storage remain as agreed.
Tensile strength 19.1 and 19.2 MPa Min. 8 Use a jaw
400 separation rate
Elongation at break 19.1 and 19.2 % Min.
of 100 mm/min.
Secant modulus 19.4 MPa Max. 160
at 2 % elongation
Dielectric strength 21 kV/mm Min. See Table 2.
Volume resistivity 23 Ω∙m Min. 10
at room temperature 23.4.2
Flame propagation 26 s Max. 60 Burning includes
Method C mm Max. 100 flaming and glowing
Corrosion resistance 32 % Min. No chemical
Heat at 150 °C ± 3 K
interaction
Elongation 19.1 and
19.2
Resistance to
36 MPa Min. 5 Use the fluids and test
selected fluids % Min. 200 temperatures specified
in Table 3.
Tensile strength 19.1 and 19.2
Immersion (24 ± 1)h
Elongation at break 19.1 and 19.2
Heat ageing 39 MPa Min. 5
Heat at 150 °C ± 3 K
% Min. 200
Tensile strength 19.1 and 19.2

Elongation at break 19.1 and 19.2
Long term ageing 50 % Min. 150 The ageing temperature
19.2
shall be 100 °C ± 3 K.
Elongation at break
– 10 – 60684-3-283  IEC:2010+A1:2013

Table 2 – Requirements for dielectric strength

a
Expanded wall thickness
Dielectric strength
mm
Min.
All dimensions Expanded ID Dielectric strength kV/mm

Types A+B
All sizes 12
a
Measure the expanded wall thickness and calculate the electric strength by dividing the

breakdown voltage by this value.

NOTE Care should be taken on selection of sizes based on these values. Refer to the
manufacturer for actual values on installed conditions.

The breakdown voltage shall be determined by the method described in 21 of IEC 60684-2.
All values shall comply with the minimum value in this table.
The sleeving shall be tested in the expanded condition.
The rate of application of the voltage shall be 500 V/s.
Table 3 – Resistance to selected fluids
Test Fluids Type Standard or symbol Immersion temperature
fluid
°C ± 2 K
No.
1 Insulating oil Mineral based IEC 60296 23
2 Cleaning fluid Solvent Isopropyl alcohol 23
3 - Water De-ionized 85
Other fluids and/or temperatures may be specified for customers with specific needs. These
additional fluids and/or temperatures shall be applicable when incorporated into agreements
between the supplier and the customer.

60684-3-283  IEC:2010+A1:2013 – 11 –

Table 4 – Additional property requirements

Property IEC 60684-2 Units Max. or Requirement Remarks

min.
Fungus resistance   The test method shall be ISO 846

Tensile strength 19.1 and 19.2 MPa Min. 7 Method B

Elongation % Min. 350 56 days exposure

Resistance to ISO 4892-3  Test method to ISO 4892-3

weathering (Method 1 C)
Samples for test 19.1 and 19.2
After 5 000 3 000 h
should be taken from recovered

test Test to
sleeving which is flattened.
Min. 8
19.1 Samples for Test 25 should be
MPa Min. 200 taken from specially prepared test
19.2
sheets (6 ± 0,1) mm thick. All
% Min. 2,5 kV
samples should be cut to the
appropriate size to fit the sample
for 20 min
holders.
Intermediate tests may also be
done at 1000 h intervals as an
intermediate check on
performance.
Resistance to 25 – Min. Class 2A Specimens shall be prepared
tracking from cross-linked moulded
2,5 kV
plaques of thickness (6 ± 1) mm
for 1 h
Specimens shall not be abraded

but cleaned with an appropriate
solvent. The method of cleaning
shall be recorded.
– 12 – 60684-3-283  IEC:2010+A1:2013

Annex A
(informative)
Guidance to the available sizes and wall thicknesses

Table A.1 – Type A, medium wall

Internal diameter Wall
Expanded Recovered Recovered wall thickness

Min. Max.
± 20 %
mm mm
15,0 6,0 2,0
30,0 12,0 2,3
50,0 20,0 2,5
70,0 25,0 3,0
75,0 30,0 2,5
90,0 30,0 3,0
100,0 40,0 2,5
120,0 50,0 3,0
170,0 60,0 3,0
Table A.2 – Type B, thick wall
Internal diameter Wall
Expanded Recovered Recovered wall thickness
Min. Max.
± 20 %
mm mm
25,0 10,0 4,0
40,0 16,0 4,0
65,0 25,0 4,0
100,0 40,0 4,0
165,0 60,0 4,0
___________
– 14 – 60684-3-283  CEI:2010+A1:2013

SOMMAIRE
AVANT-PROPOS . 15

INTRODUCTION . 17

INTRODUCTION A L'AMENDEMENT . 18

1 Domaine d'application . 19

2 Références normatives . 19

3 Désignation . 20

4 Conditions d'essai . 20
5 Exigences . 20
6 Conformité des gaines . 20
Annexe A (informative) Guide concernant les dimensions et épaisseurs de paroi
disponibles . 24

Tableau 1 – Propriétés caractéristiques . 21
Tableau 2 – Exigences pour la tension de claquage . 22
Tableau 3 – Résistance à des fluides sélectionnés . 22
Tableau 4 – Exigences de propriétés supplémentaires . 23
Tableau A.1 – Type A, paroi moyenne . 24
Tableau A.2 – Type B, paroi épaisse . 24

60684-3-283  CEI:2010+A1:2013 – 15 –

COMMISSION ELECTROTECHNIQUE INTERNATIONALE

___________
GAINES ISOLANTES SOUPLES –
Partie 3: Spécifications pour types particuliers de gaines –

Feuille 283: Gaines thermorétractables en polyoléfine

pour isolation de barre omnibus

AVANT-PROPOS
1) La Commission Electrotechnique Internationale (CEI) est une organisation mondiale de normalisation
composée de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a
pour objet de favoriser la coopération internationale pour toutes les questions de normalisation dans les
domaines de l'électricité et de l'électronique. A cet effet, la CEI – entre autres activités – publie des Normes
internationales, des Spécifications techniques, des Rapports techniques, des Spécifications accessibles au
public (PAS) et des Guides (ci-après dénommés "Publication(s) de la CEI"). Leur élaboration est confiée à des
comités d'études, aux travaux desquels tout Comité national intéressé par le sujet traité peut participer. Les
organisations internationales, gouvernementales et non gouvernementales, en liaison avec la CEI, participent
également aux travaux. La CEI collabore étroitement avec l'Organisation Internationale de Normalisation (ISO),
selon des conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux de la CEI
intéressés sont représentés dans chaque comité d’études.
3) Les Publications de la CEI se présentent sous la forme de recommandations internationales et sont agréées
comme telles par les Comités nationaux de la CEI. Tous les efforts raisonnables sont entrepris afin que la CEI
s'assure de l'exactitude du contenu technique de ses publications; la CEI ne peut pas être tenue responsable
de l'éventuelle mauvaise utilisation ou interprétation qui en est faite par un quelconque utilisateur final.
4) Dans le but d'encourager l'uniformité internationale, les Comités nationaux de la CEI s'engagent, dans toute la
mesure possible, à appliquer de façon transparente les Publications de la CEI dans leurs publications
nationales et régionales. Toutes divergences entre toutes Publications de la CEI et toutes publications
nationales ou régionales correspondantes doivent être indiquées en termes clairs dans ces dernières.
5) La CEI elle-même ne fournit aucune attestation de conformité. Des organismes de certification indépendants
fournissent des services d'évaluation de conformité et, dans certains secteurs, accèdent aux marques de
conformité de la CEI. La CEI n'est responsable d'aucun des services effectués par les organismes de
certification indépendants
6) Tous les utilisateurs doivent s'assurer qu'ils sont en possession de la dernière édition de cette publication.
7) Aucune responsabilité ne doit être imputée à la CEI, à ses administrateurs, employés, auxiliaires ou
mandataires, y compris ses experts particuliers et les membres de ses comités d'études et des Comités
nationaux de la CEI, pour tout préjudice causé en cas de dommages corporels et matériels, ou de tout autre
dommage de quelque nature que ce soit, directe ou indirecte, ou pour supporter les coûts (y compris les frais
de justice) et les dépenses découlant de la publication ou de l'utilisation de cette Publication de la CEI ou de
toute autre Publication de la CEI, ou au crédit qui lui est accordé.
8) L'attention est attirée sur les références normatives citées dans cette publication. L'utilisation de publications
référencées est obligatoire pour une application correcte de la présente publication.

9) L’attention est attirée sur le fait que certains des éléments de la présente Publication de la CEI peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence.

Cette version consolidée de la CEI 60684-3-283 porte le numéro d'édition 1.1. Elle
comprend la première édition (2010) [documents 15/597/FDIS et 15/605/RVD] et son
amendement 1 (2013) [documents 15/687/CDV et 15/704/RVC]. Le contenu technique est
identique à celui de l'édition de base et à son amendement.
Dans cette version Redline, une ligne verticale dans la marge indique où le contenu
technique est modifié par l’amendement 1. Les ajouts et les suppressions apparaissent
en rouge, les suppressions étant barrées. Une version Finale avec toutes les
modifications acceptées est disponible dans cette publication.
Cette publication a été préparée par commodité pour l’utilisateur.

– 16 – 60684-3-283  CEI:2010+A1:2013

La Norme internationale CEI 60684-3-283 a été établie par le comité d'études 15 de la CEI:

Matériaux isolants électriques solides.

Cette publication a été rédigée selon les Directives ISO/CEI, Partie 2.

Une liste de toutes les parties de la série CEI 60684, présentée sous le titre général Gaines

isolantes souples, peut être consultée sur le site web de la CEI.8

Le comité a décidé que le contenu de la publication de base et de son amendement ne sera

pas modifié avant la date de stabilité indiquée sur le site web de la CEI sous

"http://webstore.iec.ch" dans les données relatives à la publication recherchée. A cette date,

la publication sera
• reconduite;
• supprimée;
• remplacée par une édition révisée, ou
• amendée.
IMPORTANT – Le logo "colour inside" qui se trouve sur la page de couverture de cette
publication indique qu'elle contient des couleurs qui sont considérées comme utiles à
une bonne compréhension de son contenu. Les utilisateurs devraient, par conséquent,
imprimer cette publication en utilisant une imprimante couleur.

60684-3-283  CEI:2010+A1:2013 – 17 –

INTRODUCTION
La présente Norme internationale fait partie d'une série traitant des gaines isolantes souples

à usages électriques.
Cette série est composée de trois parties:

Partie 1: Définitions et exigences générales (CEI 60684-1)

Partie 2: Méthodes d'essai (CEI 60684-2)

Partie 3: Spécifications pour types particuliers de gaines (CEI 60684-3)

La présente norme contient une des feuilles constituant la Partie 3, comme suit:
Feuille 283: Gaines thermorétractables en polyoléfine pour isolation de barre omnibus

– 18 – 60684-3-283  CEI:2010+A1:2013

INTRODUCTION À L'AMENDEMENT
Le présent amendement modifie la méthode d'essai relative à la résistance aux intempéries

en raison du fait qu'elle est citée de manière erronée en tant qu'ISO 4892-3 méthode 1.Or,

cette méthode n'existe pas dans l'édition 2006 de l'ISO 4892-3. De même, après consultation

des utilisateurs de ces types de gaines, il a été décidé qu'une période de 3 000 heures

d'exposition à cette méthode était adéquate.

60684-3-283  CEI:2010+A1:2013 – 19 –

GAINES ISOLANTES SOUPLES –
Partie 3: Spécifications pour types particuliers de gaines –

Feuille 283: Gaines thermorétractables en polyoléfine

pour isolation de barre omnibus

1 Domaine d'application
La présente partie de la CEI 60684 donne les exigences relatives à deux types de gaines
thermorétractables, en polyoléfine, pour isolation des barres omnibus de rapport de rétreint
nominal 2,5:1.
Ces gaines se sont révélées être adaptées à des températures jusqu’à 100 °C.
– Type A: Paroi moyenne Diamètre intérieur type jusqu’à 170,0 mm
– Type B: Paroi épaisse Diamètre intérieur type jusqu’à 165,0 mm
Ces gaines sont normalement proposées en rouge ou en brun.
Comme ces types de gaines couvrent une gamme très large de dimensions et d’épaisseurs
de paroi, les Tableaux A.1 et A.2 donnent un guide de la gamme des dimensions disponibles.
La dimension réelle doit faire l’objet d’un accord entre l’utilisateur et le fournisseur en fonction
de la rigidité diélectrique proposée pour le tube installé et des exigences de l’utilisateur.
Les matériaux conformes à la présente spécification satisfont à des niveaux établis de
performance. Toutefois, il convient que le choix d’un matériau par un utilisateur pour une
application spécifique soit fondé sur les exigences réelles nécessaires pour obtenir des
performances adéquates de l’application concernée et qu’il ne soit pas fondé sur la seule
présente spécification.
2 Références normatives
Les documents de référence suivants sont indispensables pour l'application du présent
document. Pour les références datées, seule l'édition citée s'applique. Pour les références
non datées, la dernière édition du document de référence s'applique (y compris les éventuels
amendements).
CEI 60296:2003, Fluides pour applications électrotechniques – Huiles minérales isolantes
neuves pour transformateurs et appareillages de connexion
CEI 60684-1:2003, Gaines isolantes souples – Partie 1: Définitions et exigences générales
CEI 60684-2:1997, Gaines isolantes souples – Partie 2: Méthodes d'essai
Amendement 1 (2003)
Amendement 2 (2005)
CEI 60757:1983, Code de désignation de couleurs
ISO 846:1997, Plastiques – Evaluation de l’action des micro-organismes
ISO 4892-3:2006, Plastiques – Méthodes d'exposition à des sources lumineuses de laboratoire –
Partie 3: Lampes fluorescentes UV

– 20 – 60684-3-283  CEI:2010+A1:2013

3 Désignation
Les gaines doivent être identifiées par la désignation suivante:

a
Description Numéro de Numéro de Numéro de Type Dimension Couleur
Tableau 4
publication CEI partie CEI feuille CEI
(diamètre intérieur
code
à l'état expansé et
rétreint en mm)
↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓
Gaine CEI 60684 - 3 -283 A - 75,0/30,0 - X

Rouge
a
L’ajout de “X” à la fin de la désignation indique que les propriétés contenues dans le Tableau 4 ont fait l’objet d’un accord
entre l’utilisateur et le fournisseur.
Toutes les abréviations utilisées pour les couleurs doivent satisfaire à la CEI 60757, lorsque
celle-ci est applicable. Les couleurs non normalisées doivent être indiquées en toutes lettres.
NOTE Cette information n’est destinée qu’à l’étiquetage conformément à la CEI 60684-1.
4 Conditions d'essai
Sauf spécification contraire, la gaine doit être rétreinte dans une étuve à ventilation forcée
pendant (10 ± 1) min à 200 °C ± 3 K avant l'essai.
5 Exigences
Les gaines doivent satisfaire aux exigences données dans les Tableaux 1, 2, 3 et 4, si
applicables, en plus des exigences générales données dans la CEI 60684-1.
6 Conformité des gaines
La conformité aux exigences de la présente spécification doit normalement être fondée sur
les résultats provenant des dimensions types
– Type A: DI rétreint 25 mm - 30 mm
– Type B: DI rétreint 25 mm - 40 mm

60684-3-283  CEI:2010+A1:2013 – 21 –

Tableau 1 – Propriétés caractéristiques

Propriété CEI 60684-2 Unités Max. Exigences  Remarques

article ou ou
paragraphe Min.
Dimensions 3
– Diamètre intérieur 3.1.2 mm Doit faire l’objet d’un
– Epaisseur des parois 3.3.2 mm accord entre l’acheteur
– Concentricité 3.3.3 % et le fournisseur

– expansée Min. 60
– rétreinte Min. 85
Choc thermique 6
Chaleur à 150 °C ± 5 K
Résistance à la traction 19.1 et 19.2 MPa Min. 5
Allongement à la 19.1 et 19.2 % Min. 200
rupture
Variation longitudinale 9 % Max. –10
+5
Flexion à basse 14 – – Il ne doit pas y avoir de
Essai à –40 °C
température traces de fendillement.
Pour les bandes, le mandrin
doit avoir une taille comprise
entre 20 et 22 fois l’épais-
seur de paroi. Les gaines de
section complète sont
essayées non remplies et le
mandrin doit correspondre à
une valeur entre 20 et 22
fois le diamètre extérieur.
Stabilité des dimensions 16 – – Les dimensions doivent Voir Domaine
au stockage rester telles qu’elles d’application.
ont été décidées.
Résistance à la traction 19.1 et 19.2 MPa Min. 8 Utiliser une vitesse de
séparation des mâchoires
Allongement à la rupture 19.1 et 19.2 % Min. 400
de 100 mm/min.
Module sécant à 2 % 19.4 MPa Max. 160
d’allongement
Rigidité diélectrique 21 kV/mm Min. Voir le Tableau 2
Résistivité transversale à 23 Min. 10
Ω· m
température ambiante 23.4.2
Propagation de la 26 s Max. 60 La combustion comprend
flamme Méthode C mm Max. 100 l'inflammation et
l'incandescence.
Résistance à la corrosion 32 % Min. Pas d’interaction Chaleur 150 °C ± 3 K
chimique
Allongement 19.1 et 19.2
Résistance à des fluides 36
Utiliser les fluides et les
sélectionnés   températures d’essai
spécifiés au Tableau 3.
Résistance à la traction 19.1 et 19.2 MPa Min. 5
Immersion (24 ± 1) h
Allongement à la rupture 19.1 et 19.2 % Min. 200
Vieillissement thermique 39
Chaleur à 150 °C ± 3 K
Résistance à la traction 19.1 et 9.2 MPa Min. 5

Allongement à la rupture 19.1 et 19.2 % Min. 200
Vieillissement à long 50 % Min. 150 La température de
terme 19.2 vieillissement doit être de

100 °C ± 3 K.
Allongement à la rupture
– 22 – 60684-3-283  CEI:2010+A1:2013

Tableau 2 – Exigences pour la tension de claquage

a
Epaisseur de paroi expansée
Rigidité diélectrique
mm
Min.
Toutes les dimensions DI expansé Rigidité diélectrique kV/mm

Types A+B
Toutes les dimensions 12
a
Mesurer l’épaisseur de paroi expansée et calculer la rigidité diélectrique en divisant la tension
de claquage par cette valeur.
NOTE Il convient d’apporter un soin particulier à la sélection des dimensions de ces valeurs.
S’adresser au fabricant pour les valeurs réelles dans les conditions installées.

La tension de claquage doit être déterminée par la méthode décrite en 21 de la CEI 60684-2.
Toutes les valeurs doivent être conformes à la valeur minimale dans ce tableau.
La gaine doit subir les essais en condition expansée.
La vitesse d’application de la tension doit être de 500 V/s.
Tableau 3 – Résistance à des fluides sélectionnés
Essai Fluides Type Norme ou symbole Température
fluide d’immersion
No.
°C ± 2 K
1 Huile isolante Base minérale CEI 60296 23
2 Fluide de nettoyage Solvant Alcool isopropylique 23
3 - Eau Déminéralisée 85
D’autres fluides et/ou températures peuvent être spécifiés pour les clients ayant des besoins
spécifiques. Ces fluides et/ou températures supplémentaires doivent être applicables
lorsqu’ils sont intégrés à des accords entre fournisseur et client.

60684-3-283  CEI:2010+A1:2013 – 23 –

Tableau 4 – Exigences de propriétés supplémentaires

Propriété CEI 60684-2 Unités Max. Exigence Remarques

ou
min.
Résistance aux   La méthode d’essai doit être

moisissures   celle de l’ISO 846.

Résistance à la traction 19.1 et 19.2 MPa Min. 7 Méthode B

Allongement % Min. 350 56 jours d’exposition

Résistance aux ISO 4892-3  Méthode d’essai pour

intempéries (Méthode 1 C) ISO 4892-3

Après 5000 Il convient que les échantillons

3 000 h pour les essais 19.1 et 19.2
essai Essai soient prélevés de gaine

selon rétreinte aplatie. Il convient
que les échantillons pour les
Min.
19.1
essais 25 soient prélevés de
MPa 200
Min.
feuilles d’essai préparées de
19.2
(6 ± 0,1) mm d’épaisseur. Il
%
2,5 kV
Min.
convient que tous les
pendant 20 min
échantillons soient coupés à la
taille appropriée pour s’adapter
au porte-échantillon.
Des essais intermédiaires
peuvent aussi être effectués à
intervalles de 1000 h comme
vérification intermédiaire de
performance.
Résistance aux 25 - Min. Classe 2A Les échantillons doivent être
courants de préparés à partir de plaques
2,5 kV
cheminement moulées réticulées d’une
épaisseur de (6 ±1) mm.
pour 1 h
Les échantillons ne doivent pas

être abrasés mais ils doivent
être nettoyés avec un solvant
approprié. La méthode de
nettoyage doit être consignée.

– 24 – 60684-3-283  CEI:2010+A1:2013

Annexe A
(informative)
Guide concernant les dimensions et épaisseurs de paroi disponibles

Tableau A.1 – Type A, paroi moyenne

Diamètre intérieur Paroi
Expansé Rétreint Epaisseur de paroi après

Min. Max. rétreint
mm mm ± 20 %
15,0 6,0 2,0
30,0 12,0 2,3
50,0 20,0 2,5
70,0 25,0 3,0
75,0 30,0 2,5
90,0 30,0 3,0
100,0 40,0 2,5
120,0 50,0 3,0
170,0 60,0 3,0
Tableau A.2 – Type B, paroi épaisse
Diamètre intérieur Paroi
Expansé Rétreint Epaisseur de paroi après
Min. Max. rétreint
mm mm ± 20 %
25,0 10,0 4,0
40,0 16,0 4,0
65,0 25,0 4,0
100,0 40,0 4,0
165,0 60,0 4,0
___________
IEC 60684-3-283 ®
Edition 1.1 2013-12
FINAL VERSION
VERSION FINALE
Flexible insulating sleeving –
Part 3: Specifications for individual types of sleeving – Sheet 283: Heat-
shrinkable, polyolefin sleeving for bus-bar insulation

Gaines isolantes souples –
Partie 3: Spécifications pour types particuliers de gaines – Feuille 283: Gaines
thermorétractables en polyoléfine pour isolation de barre omnibus

– 2 – 60684-3-283  IEC:2010+A1:2013

CONTENTS
FOREWORD . 3

INTRODUCTION . 5

INTRODUCTION TO THE AMENDMENT . 6

1 Scope . 7

2 Normative references . 7

3 Designation . 8

4 Conditions of test . 8
5 Requirements .
...