Status
Not Published
Public Enquiry End Date
17-Sep-2026
Current Stage
4020 - Public enquire (PE) (Adopted Project)
Start Date
30-Jun-2026
Due Date
17-Nov-2026
Completion Date
07-Sep-2026

Buy Documents

Draft

oSIST prEN IEC 62271-205:2026 - BARVE

English language (38 pages)
Preview
Preview
e-Library read for
×1 day

oSIST prEN IEC 62271-205:2026 is the SIST publication of IEC 62271-205 for high-voltage switchgear and controlgear. It specifies service conditions, ratings, design and construction rules, and test methods for AC compact switchgear assemblies, mobile substations and prefabricated substations for rated voltages above 52 kV and service frequencies up to 60 Hz. It is written for manufacturers, users, and test and commissioning teams that need to specify, build, test, transport or install these assemblies.

What does oSIST prEN IEC 62271-205:2026 specify?

oSIST prEN IEC 62271-205:2026 covers service conditions, rated characteristics, general structural requirements and test methods for compact switchgear assemblies, mobile substations and prefabricated substations. It is built around IEC 62271-1 and adds requirements for assemblies that combine several devices into one functional unit.

The document applies to indoor and/or outdoor installations. It also makes a clear distinction between compact switchgear assemblies, mobile substations and prefabricated substations, while allowing them to overlap in practice.

Compact switchgear assemblies may be air-insulated, mixed technology switchgear (MTS) or other combinations of switching devices and associated equipment. Complete GIS-only switchgear assemblies are outside this part and are covered by IEC 62271-203.

AnnexWhat it covers
Annex AExplanations and examples of compact switchgear assemblies, including the main arrangement types
Annex BBackground and scope explanation for mobile substations
Annex CBackground and scope explanation for prefabricated substations

The main clauses cover scope, normative references, terms and definitions, service conditions, ratings, design and construction, type tests, routine tests, selection guidance, procurement information, transport and installation, safety, and environmental influence.

What are the key requirements of oSIST prEN IEC 62271-205:2026?

Service conditions and ratings

Clause 4 applies the service conditions of IEC 62271-1, with extra guidance for enclosed installations and for substations that may be used outdoors or indoors. For enclosed installations, indoor service conditions are assumed; if the internal air temperature rises above the device limits, derating can be needed. In practice, this means the user and manufacturer need to match the design to the installation environment before ordering.

Clause 5 defines the main ratings for both compact switchgear assemblies and mobile/prefabricated substations. The document requires the ratings to be assigned so that no individual device is driven outside its own rated capability. For mobile and prefabricated substations, high-voltage and medium-voltage parts are rated separately where needed.

Design, construction and safety

Clause 6 requires the design to take account of electrical, mechanical and thermal interaction between devices. That matters because these assemblies are compact and shared components can affect performance, heating and clearances.

For substations, the clause also requires safe operation, inspection and maintenance, and resistance to transport and handling loads. It points the reader to IEC 61936-1 for minimum safety requirements such as escape routes, clearances to live parts, touch and step voltages, and access limitations.

Earthing, nameplates, locking devices and position indication are all addressed in Clause 6. The document requires a common earthing terminal or individual earthing terminals, and all accessible main-circuit parts must be capable of being earthed for maintenance. For compact switchgear assemblies, a common nameplate must show the key ratings from Clause 5; for mobile substations, a common nameplate is recommended and should also help identify transport and safety information.

Gas and vacuum tightness are handled at the level of individual devices rather than as one overall property of the full assembly. The document also requires pressure relief devices to limit danger to operators and says moving pressurized equipment must keep its function during movement.

Type testing

Clause 7 is centered on representative testing. For compact switchgear assemblies, type tests may be done on the full assembly or on representative combinations, but the manufacturer must show that the missing parts do not reduce the stresses seen in the test. Table 1 groups the main type tests for compact switchgear assemblies, including dielectric, radio interference voltage (RIV), resistance measurement, continuous current, short-time and peak withstand current, and mechanical and environmental tests.

For mobile and prefabricated substations, the document takes a different approach. If the devices are individually type-tested and the overall design meets the relevant requirements, full substation type testing is not necessarily required. Project-specific special tests can also be agreed between the manufacturer and user.

Routine tests and site checks

Clause 8 requires routine testing of complete prefabricated substations or transport units whenever practicable. The routine programme includes dielectric tests on interconnections, tests on auxiliary and control circuits, resistance measurement of the main circuit, tightness checks, design and visual checks, functional tests, and tests after site assembly where relevant.

For compact switchgear assemblies, routine tests should be carried out on the fully assembled unit at the manufacturer’s premises when possible. If that is not possible, tests on single devices are allowed, but the parties need to agree whether site tests are also required.

Procurement, transport, installation and maintenance

Clauses 9 and 10 are especially useful for buyers and specifiers. They describe the information to collect for selection, enquiries, tenders and orders, including functions, system connection, service conditions, electrical ratings, transformer data, transport limits, environmental exposure, intended use and expected service life.

Clause 11 covers transport, storage, installation, operating instructions and maintenance. The manufacturer is expected to provide enough information for on-site tests and correct installation, and the user and manufacturer should agree on risk-mitigation measures for mobile and prefabricated substations.

What terms does oSIST prEN IEC 62271-205:2026 define?

  • Compact switchgear assembly - An assembly of high-voltage devices where at least one switching device is directly connected to or shares components with other devices, so the functions interact.
  • Prefabricated substation - A prefabricated high-voltage assembly that includes at least a power transformer and/or high-voltage switchgear and controlgear, usually with additional modules and circuits.
  • Mobile substation - A prefabricated electrical substation designed to be relocated during its lifetime and connected to the grid itself or via a substation.
  • High-voltage module - A functional unit above 52 kV that may include switching devices, instrument transformers and the connection to the grid.
  • Medium-voltage module - A functional unit up to and including 52 kV that may include switching devices, instrument transformers and related auxiliary and control devices.
  • Protection & control module - A functional unit that may integrate automation, communication, protection relays, safety automatic devices and AC and DC power supply systems.
  • Vehicle - The transportation system used to relocate a mobile substation or parts of it.
  • Agreement between user and manufacturer - A documented understanding that sets the responsibilities, technical requirements and conditions for the product or system.

Who uses oSIST prEN IEC 62271-205:2026?

Manufacturers use oSIST prEN IEC 62271-205:2026 to design assemblies, assign ratings, define tests and prepare nameplates and instructions. Users and customers use it to specify what they need in tenders and contracts.

Test laboratories and inspection teams use it to plan type tests, routine tests and site checks. Installation, commissioning and maintenance teams use it for transport, handling, site assembly, functional checks and safe operation of these compact and often customized installations.

It is relevant to high-voltage switchgear and substation projects where rated voltage is above 52 kV and where compact, prefabricated or mobile solutions are considered.

What changed in oSIST prEN IEC 62271-205:2026 from the previous edition?

oSIST prEN IEC 62271-205:2026 is the second edition and replaces the first edition published in 2008.

The document states these main changes:

  • the scope was enlarged to include prefabricated substations and mobile substations
  • the terms mobile substation and prefabricated substation were added
  • references to IEC publications were updated
  • the clauses and subclauses were reorganized to separate compact switchgear assemblies, mobile substations and prefabricated substations where needed

Which standards are used with oSIST prEN IEC 62271-205:2026?

  • IEC 62271-1 - the core common specification for alternating current switchgear and controlgear; this part is read with it unless stated otherwise.
  • IEC 61936-1 - provides the installation, insulation and safety framework for power installations exceeding 1 kV AC and 1.5 kV DC.
  • IEC 62271-4 - gives the handling procedures for insulating and switching gases, used for gas-handling recommendations.
  • IEC 62271-203 - covers gas-insulated metal-enclosed switchgear above 52 kV and applies where a compact switchgear assembly includes GIS.
  • IEC 60068-2-17 - gives the environmental sealing test referenced for sealing-related checks.
  • IEC 60076 (all parts) - applies to transformer-module requirements mentioned for prefabricated and mobile substations.
  • IEC 61869-10 and IEC 61869-11 - provide requirements for low-power passive current and voltage transformers named in the prefabricated substation example.
  • IEC 62052-11 - provides the metering equipment reference named in the prefabricated substation example.
  • IEC 62271-202 - is referenced for medium-voltage prefabricated substations and related background in the annexes.

What does the oSIST prEN IEC 62271-205:2026 document contain?

The document contains a clause structure that covers scope, definitions, service conditions, ratings, design, type tests, routine tests, procurement information, installation, maintenance, safety and environmental aspects. Clause 7 includes Table 1 for type tests on compact switchgear assemblies.

It also contains many explanatory figures in Annexes A, B and C that show example arrangements, module combinations and simplified lifetimes for compact switchgear assemblies, mobile substations and prefabricated substations. Those illustrations help readers understand how the assemblies are built and how they are used in practice.

For buyers and project teams, the most useful parts are the procurement clauses, the transport and commissioning guidance, and the test requirements for assemblies and transport units.

Relations

Effective Date
26-Jul-2022

Buy Documents

Draft

oSIST prEN IEC 62271-205:2026 - BARVE

English language (38 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

IMQ S.p.A. (Certification)

Italian electrical product certification.

ACCREDIA Italy Verified

SLG Prüf- und Zertifizierungs GmbH

German testing and certification body.

DAKKS Germany Verified

UL Solutions

Global safety science company with testing, inspection and certification.

ANAB United States Verified

Sponsored listings

Frequently Asked Questions

oSIST prEN IEC 62271-205:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "High-voltage switchgear and controlgear - Part 205: Compact switchgear assemblies, mobile and prefabricated substations for rated voltage above 52 kv". This standard covers: High-voltage switchgear and controlgear - Part 205: Compact switchgear assemblies, mobile and prefabricated substations for rated voltage above 52 kv

High-voltage switchgear and controlgear - Part 205: Compact switchgear assemblies, mobile and prefabricated substations for rated voltage above 52 kv

oSIST prEN IEC 62271-205:2026 is classified under the following ICS (International Classification for Standards) categories: 29.130.10 - High voltage switchgear and controlgear; 29.130.99 - Other switchgear and controlgear. The ICS classification helps identify the subject area and facilitates finding related standards.

oSIST prEN IEC 62271-205:2026 has the following relationships with other standards: It is inter standard links to SIST EN 62271-205:2008. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

oSIST prEN IEC 62271-205:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 INTRODUCTION
  • 2 This standard uses the terms compact switchgear assemblies, prefabricated substations and
  • 11 Compact switchgear assemblies consist of at least one mechanical switching device directly
  • 15 A combination of above-described terms is possible. For instance, a compact switchgear
  • 28 The CIGRE Technical Brochure 907 [1] “Mobile substations incorporating HV GIS” provides
  • 37 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR-
  • 39 Part 205: AC compact switchgear assemblies, mobile and prefabricated
  • 69 The interaction between devices might be due to proximity, sharing of components or a
  • 77 The parts of this document relevant for compact switchgear assemblies do not apply to
  • 84 In general, a prefabricated substation is a high-voltage assembly, comprising of different
  • 95 Compact switchgear assemblies can be an integral part of the high-voltage switchgear and
  • 97 A mobile substation is a prefabricated substation designed and intended to be transported

1 INTRODUCTION

2 This standard uses the terms compact switchgear assemblies, prefabricated substations and

3 mobile substations. Even if these terms suggest a clear distinction, the real applications show 4 a wide overlap and also a mixture of these terms. This is, among other things, due to the fact, 5 that compact switchgear assemblies, prefabricated substations and mobile substations are 6 generally highly customized and thus almost each application can be considered individual. 7 A prefabricated substation is basically designed for installation without further relocation. It is 8 pre-built off-site e.g., in a factory, and then transported to its final installation site. 9 A mobile substation is designed for temporary installations and relocations. It is pre-built off- 10 site, e.g., in a factory, and then transported to its location for use.

11 Compact switchgear assemblies consist of at least one mechanical switching device directly

12 connected to, or sharing components, with one or more other devices (e.g., instrument 13 transformers, bushings etc.). In general, they are designed for fixed installation and in most 14 cases transported to site as a whole.

15 A combination of above-described terms is possible. For instance, a compact switchgear

16 assembly may also form a part of a mobile substation.

17 Within mobile or prefabricated substations with rated voltages above 52 kV, switching devices 18 rated up to 52 kV (e.g., medium-voltage switching devices at 36 kV) as well as high-voltage 19 switching devices (e.g., 145 kV) may be used. For a better understanding in reading this 20 document the term “medium-voltage” will be used where necessary. 21 Mobile substations and prefabricated substations usually, but not exclusively, consist of the 22 following modules:

23 – High-voltage module; 24 – Power transformer module; 25 – Medium-voltage module; 26 – Protection and control module; 27 Mobile substations require additional suitable vehicles for transportation.

28 The CIGRE Technical Brochure 907 [1] “Mobile substations incorporating HV GIS” provides

29 guidance for mobile substation applications, which extend from those intended for rapid 30 deployment in an emergency through relocatable designs to prefabricated or ’build off-site’ 31 solutions. Three cases for mobile/prefabricated substation are defined:

32 – Substation for short term (emergency) use – typically 1 week ÷ 6 months; 33 – Substation for intermediate term use – typically 6 months ÷ 3 years; 34 – Substation for long term use – typically more than 3 years. 35 More explanatory information could be found in CIGRE Technical Brochure 907 [1].

oSIST prEN IEC 62271-205:2026

37 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR-

39 Part 205: AC compact switchgear assemblies, mobile and prefabricated

40 substations for rated voltage above 52 kV

43 1 Scope 44 1.1 General 45 This part of IEC 62271 series applies to service conditions, rated characteristics, general 46 structural requirements and test methods of compact switchgear assemblies, mobile 47 substations and prefabricated substations, for indoor and/or outdoor installations in systems 48 having rated voltages above 52 kV and service frequencies up to and including 60 Hz. 49 1.2 Compact switchgear assemblies 50 In general, compact switchgear assemblies consist of at least one mechanical switching device 51 directly connected to or sharing components with one or more other devices such that there is 52 an interaction between the functions of the individual devices. 53 The devices, defined by IEC standards, which can be a part of a compact switchgear assembly 54 are exemplary listed below and is not be limited to:

55 NOTE To simplify the reading of this document, the term "switching device" is used instead of the term "mechanical 56 switching device".

57 Switching devices:

58 – Circuit-breakers 59 – Disconnectors/Earthing switches 60 – Switch-disconnectors 61 – Disconnecting circuit-breakers 62 Devices:

63 – Instrument transformers 64 – Surge arresters 65 – Bushings 66 – Insulators 67 – Cable connections 68 – Transformer connections

69 The interaction between devices might be due to proximity, sharing of components or a

70 combination of both. The assemblies can contain devices of air insulated switchgear (AIS) only 71 or a combination of part of AIS and part of gas-insulated metal-enclosed switchgear (GIS), so 72 called mixed technology switchgear (MTS) and can be delivered entirely prefabricated or 73 partially assembled.

74 Each switching device forming a part of a compact switchgear assembly shall comply with the 75 relevant individual standard. If a part of the compact switchgear assembly is formed by gas- 76 insulated metal-enclosed switchgear devices, the requirements of IEC 62271-203:2022 apply.

77 The parts of this document relevant for compact switchgear assemblies do not apply to

78 switchgear assemblies (for fixed or mobile purpose) consisting solely of GIS which are covered 79 by IEC 62271-203.

oSIST prEN IEC 62271-205:2026

80 It is not possible to define all potential arrangements of compact switchgear assemblies. Four 81 examples are shown for information in Annex A.

83 1.3 Prefabricated substation and mobile substation

84 In general, a prefabricated substation is a high-voltage assembly, comprising of different

85 functional type-tested modules, assembled off-site in a factory and then transported to its final 86 location for installation. The majority of the assembly and testing operations which are normally 87 carried out at site are completed before delivery in order to shorten site works. A prefabricated 88 substation is based on functional modules and consists at least of a power transformer module 89 and/or a high-voltage switchgear and controlgear module. Further functional modules, which 90 may be part of a prefabricated substation, are listed below but shall not be seen as conclusive:

91 – Protection and control module 92 – Medium-voltage module 93 – Lightning protection 94 – Power cable

95 Compact switchgear assemblies can be an integral part of the high-voltage switchgear and

96 controlgear module and can be therefore part of a prefabricated substation.

97 A mobile substation is a prefabricated substation designed and intended to be transported

98 during lifetime by use of an adequate vehicle. Requirements for the vehicle can be linked to 99 local regulations and are not in the scope of this document. 100 In general, it is not feasible to specify every possible configuration of prefabricated and mobile 101 substations. Annex B provides more information on mobile substations and Annex C on 102 prefabricated substations.

103 NOTE For the use of this document high voltage (IEC 60050-601:1985 [2], 601-01-27) is the rated voltage above 104 1 000 V. However, medium voltage (IEC 60050-601:1985 [2], 601-01-28) is commonly used for distribution systems 105 with voltages above 1 000 V and generally applied up to and including 52 kV. For a better understanding in reading 106 this document the term “medium voltage” will be used where necessary. 107 2 Normative references 108 The following publications are referred to in the text in such a way that some or all of their 109 content constitutes requirements of this document. For dated references, only the edition cited 110 applies. For undated references, the latest edition of the referenced publication (including any 111 amendments) applies.

112 IEC 60068-2-17 Environmental testing - Part 2-17: Tests - Test Q: Sealing 113 IEC 61936-1 Power installations exceeding 1 kV AC and 1,5 kV DC - Part 1: AC 114 IEC 62271-1 High-voltage switchgear and controlgear – Part 1: Common specifications for 115 alternating current switchgear and controlgear 116 IEC 62271-4 High-voltage switchgear and controlgear – Part 4: Handling procedures for gases 117 for insulating and/or switching 118 IEC 62271-203 High-voltage switchgear and controlgear – Part 203: Gas-insulated metal- 119 enclosed switchgear for rated voltages above 52 kV 120 3 Terms and definitions 121 3.1 General terms 122 For the purposes of this document, the terms and definitions given in IEC 62271-1:2017 and 123 IEC 62271-1:2017/AMD1:2021, the publications mentioned in clause 2 and the following apply.

oSIST prEN IEC 62271-205:2026

124 ISO and IEC maintain terminology databases for use in standardization at the following 125 addresses:

126 – IEC Electropedia: available at https://www.electropedia.org/ 127 – ISO Online browsing platform: available at https://www.iso.org/obp 128 3.1.1 129 agreement between user and manufacturer 130 documented understanding between the user and/or customer and the manufacturer defining 131 responsibilities, technical requirements, and conditions applicable to the product or system. 132 3.2 Assemblies of switchgear and controlgear 133 3.2.1 134 compact switchgear assembly 135 assembly of high-voltage devices consisting of at least one switching device directly connected 136 to, or sharing components with, one or more other devices such that there is an interaction 137 between the functions of the individual devices 138 Note 1 to entry: Assembly of high-voltage devices can be made of “air insulated/air insulated” or “air insulated/gas 139 insulated” devices. Annex A provides examples of compact switchgear assemblies. 140 Note 2 to entry: A compact switchgear assembly may be mounted on one or more structures, but it is only intended 141 for installation and operation as a single, complete unit. 142 Note 3 to entry: Interaction is the transfer of stresses (e.g., electrical, mechanical and thermal) between the 143 individual devices.

144 3.2.2 145 prefabricated substation 146 prefabricated high-voltage assembly comprising at least a power transformer and/or a high- 147 voltage switchgear and controlgear, and usually one or several of the following devices:

148 medium-voltage switchgear and controlgear, high-voltage interconnection, medium-voltage 149 interconnection, auxiliary and control equipment and circuits 150 Note 1 to entry: A prefabricated substation includes all main and earthing circuits to be connected through 151 appropriate interfaces to external high-voltage and medium-voltage cables and to external earthing system and 152 (protective) bonding conductor (if any).

153 Note 2 to entry: A prefabricated substation may be partially or completely protected by an enclosure. 154 Note 3 to entry: A prefabricated substation is normally not designed for relocation to alternative sites during it s 155 lifetime.

156 Note 4 to entry: Annex C provides some more information of prefabricated substations. 157 [SOURCE: IEC 62271-202:2022 [3], 3.2.101, modified - change from “low-voltage” to “medium- 158 voltage”; “and type-tested” deleted; “an enclosure containing” deleted; Note 2, Note 3 and 159 Note 4 to entry added] 160 3.2.3 161 mobile substation 162 pre-fabricated electrical substation which is designed to be relocated to alternative sites during 163 lifetime and connectable to the grid itself or via a substation. 164 Note 1 to entry: Mobile substations are normally mounted as an integral part of a vehicle for road or train 165 transportation. Alternatively, they can also be mounted on e.g., a platform or rack which is at site unloaded and 166 placed on ground until relocation.

167 Note 2 to entry: According to the intended usage of the mobile substation ( e.g., short term emergency use or 168 intermediate use during renovation/reconstruction of an existing substation) the design and requirements e.g., on 169 type-tests and site acceptance tests may differ.

170 Note 3 to entry: A mobile substation can consist of different transportation units 171 Note 4 to entry: Annex B provides more information and examples of mobile substations. 172 3.2.4 173 high-voltage module 174 functional unit with a rated voltage above 52 kV, may consisting of, but not limited for, switching 175 devices, instrument transformers including their associated auxiliary and control devices, 176 establishing the connection to the existing grid by either overhead line or cable connection

oSIST prEN IEC 62271-205:2026

177 Note 1 to entry: The functional unit may be prefabricated. 178 Note 2 to entry: The functional unit may be based on compact switchgear assemblies or e.g., GIS (covered by 179 IEC 62271-203).

180 3.2.5 181 transformer module 182 functional unit for a power transformer and additional windings if applicable and/or a shunt 183 reactor, as well as associated auxiliary, protection and control devices . 184 3.2.6 185 medium-voltage module 186 functional unit with a rated voltage up to and including 52 kV, may consisting of, but not limited 187 to, switching devices, instrument transformers, medium-voltage / low-voltage power 188 transformer, reactive power compensation device including their associated auxiliary and 189 control devices 190 Note 1 to entry: The functional unit may be prefabricated. 191 3.2.7 192 protection & control module 193 functional unit which may integrate automation system, scheduling automation system, 194 communication system, protection relay and safety automatic device, AC and DC power supply 195 system, time synchronization device, auxiliary facilities intelligent control and other equipment 196 Note 1 to entry: The functional unit may be a combination of protection & control system and local power supply 197 system.

198 3.2.8 199 vehicle 200 transportation system designed to relocate mobile substation or parts of it ( e.g., trailer) 201 4 Normal and special service conditions 202 Clause 4 of IEC 62271-1:2017 and IEC 62271-1:2017/AMD1:2021 is applicable with the 203 following additions:

204 Unless otherwise specified in this document, a prefabricated or mobile substation is intended 205 to be used in accordance with its rated characteristics and at locations compliant with the 206 normal service conditions defined for outdoor switchgear and controlgear in IEC 62271-1:2017 207 and IEC 62271-1:2017/AMD1:2021.

208 Inside an enclosed installation (e.g., inside a container or indoor installation) of a prefabricated 209 or mobile substation, it is assumed that the normal indoor service conditions defined for indoor 210 switchgear and controlgear in IEC 62271-1:2017 and IEC 62271-1:2017/AMD1:2021 prevail. 211 The air temperature inside an enclosed installation of a prefabricated or mobile substation might 212 differ from the ambient air temperature. If the air temperature inside the enclosed installation is 213 higher than the limits defined for the devices in their respective product standards, de -rating 214 can be necessary 215 Generally, as compact switchgear assemblies, prefabricated substations and mobile 216 substations can contain devices that are not covered by IEC 62271-1 (e.g., voltage 217 transformers), the normal and special service conditions of these devices shall at least meet 218 Clause 4 of IEC 62271-1:2017 and IEC 62271-1:2017/AMD1:2021 without the need for derating.

oSIST prEN IEC 62271-205:2026

221 5 Ratings 222 5.1 Compact switchgear assemblies 223 5.1.1 General 224 Subclause 5.1 of IEC 62271-1:2017 and IEC 62271-1:2017/AMD1:2021 is applicable, except 225 as follows.

226 The ratings of a compact switchgear assembly are the following:

227 a) rated voltage (Ur); 228 rated insulation level (Up, Ud, and US where applicable); 229 b) rated frequency (fr) 230 c) rated continuous current (I ) (for main circuits); r 231 d) rated short-time withstand current (Ik) (for main and earthing circuits); 232 e) rated peak withstand current (I ) (for main and earthing circuits); p 233 f) rated duration of short-circuit (t ) (for main and earthing circuits); k 234 and as applicable 235 g) Individual rated values of the high-voltage devices forming the compact switchgear 236 assembly, including their operating devices (supply voltage and frequency), auxiliary and 237 control circuits 238 The ratings of the compact switchgear assembly shall be assigned ensuring that operation of 239 the compact switchgear assembly within its assigned ratings does not expose any individual 240 device to conditions which are outside its rated capabilities. 241 Further ratings are subjected to agreement between user and manufacturer. 242 5.1.2 Rated voltage (Ur) 243 Subclause 5.2 of IEC 62271-1:2017 and IEC 62271-1:2017/AMD1:2021 is applicable with the 244 following addition:

245 The compact switchgear assembly shall be suitable for the rated voltage. 246 For the purposes of this document, the rated voltage (U ) defined in IEC 62271-1:2017 and r 247 IEC 62271-1:2017/AMD1:2021 is the rated voltage of the compact switchgear assembly (U ) r 248 NOTE 1: Devices forming part of the compact switchgear assembly can have individual values of rated voltage in 249 accordance with the relevant product standards.

250 5.1.3 Rated insulation level (Up, Ud, and Us) 251 Subclause 5.3 of IEC 62271-1:2017 and IEC 62271-1:2017/AMD1:2021 is applicable with the 252 following addition:

253 The compact switchgear assembly shall be suitable for the rated insulation level. 254 5.1.4 Rated frequency (fr) 255 Subclause 5.4 of IEC 62271-1:2017 and IEC 62271-1:2017/AMD1:2021 is applicable with the 256 following addition:

257 The compact switchgear assembly shall be suitable for the rated frequency. 258 5.1.5 Rated continuous current (Ir) 259 Subclause 5.5 of IEC 62271-1:2017 and IEC 62271-1:2017/AMD1:2021 is applicable with the 260 following addition:

oSIST prEN IEC 62271-205:2026

261 The compact switchgear assembly shall be suitable for the rated continuous current. 262 5.1.6 Rated short-time withstand current (Ik) 263 Subclause 5.6 of IEC 62271-1:2017 and IEC 62271-1:2017/AMD1:2021 is applicable with the 264 following addition:

265 The compact switchgear assembly shall be suitable for the rated short-time withstand current. 266 An earthing switch may be assigned a rating different from the rating of the related main circuit 267 (if applicable).

268 An earthing switch forming an integral part of a combined function earthing switch may be 269 assigned to a rating different from the rating of its main circuit. 270 5.1.7 Rated peak withstand current (Ip) 271 Subclause 5.7 of IEC 62271-1:2017 and IEC 62271-1:2017/AMD1:2021 is applicable with the 272 following addition:

273 The compact switchgear assembly shall be suitable for the rated peak withstand current. 274 An earthing switch may be assigned a rating different from the rating of the related main circuit 275 (if applicable).

276 An earthing switch forming an integral part of a combined disconnecting-earthing switch may 277 be assigned a rating different from the rating of its main circuit. 278 5.1.8 Rated duration of short-circuit (tk) 279 Subclause 5.8 of IEC 62271-1:2017 and IEC 62271-1:2017/AMD1:2021 is applicable with the 280 following addition:

281 The compact switchgear assembly shall be suitable for the rated duration of short -circuit. 282 An earthing switch may be assigned a rating different from the rating of the related main circuit . 283 An earthing switch forming an integral part of a combined disconnecting-earthing switch may 284 be assigned to a rating different from the rating of its main circuit. 285 5.1.9 Rated supply voltage of auxiliary and control circuits (U ) a 286 Subclause 5.9 of IEC 62271-1:2017 and IEC 62271-1:2017/AMD1:2021 is applicable. 287 5.1.10 Rated supply frequency of auxiliary circuits 288 Subclause 5.10 of IEC 62271-1:2017 and IEC 62271-1:2017/AMD1:2021 is applicable. 289 5.2 Mobile substations and prefabricated substations 290 5.2.1 General 291 Subclause 5.1 of IEC 62271-1:2017 and IEC 62271-1:2017/AMD1:2021 is applicable, except 292 as follows.

...