Safety rules for the construction and installation of lifts - Particular applications for passenger and goods passenger lift - Part 70: Accessibility to lifts for persons including persons with disability

This document specifies the minimum requirements for the safe and independent access and use of lifts
by persons, including persons with disabilities. It covers the needs of persons with disabilities according
to Annex A.
NOTE For guidance on solutions for increased accessibility and usability, see Annex D.

Sicherheitsregeln für die Konstruktion und den Einbau von Aufzügen - Besondere Anwendungen für Personen- und Lastenaufzüge - Teil 70: Zugänglichkeit von Aufzügen für Personen einschließlich Personen mit Behinderungen

Dieses Dokument legt die Mindestanforderungen für den sicheren und unabhängigen Zugang und die Benutzung von Aufzügen durch einen weiten Personenkreis einschließlich Personen mit Behinderungen fest. Sie deckt die Bedürfnisse von Menschen mit Behinderungen gemäß Anhang A ab.
ANMERKUNG    Siehe Anhang D als Anleitung für Lösungen zu einer erhöhten Zugänglichkeit und Bedienbarkeit.

Règles de sécurité pour la construction et l'installation des élévateurs - Applications particulières pour les ascenseurs et ascenseurs de charge - Partie 70 : Accessibilité aux ascenseurs pour toutes les personnes y compris les personnes avec handicap

Varnostna pravila za konstruiranje in vgradnjo dvigal (liftov) - Posebne izvedbe osebnih in osebno-tovornih dvigal - 70. del: Dostopnost dvigal za osebe, vključno z invalidi

Ta dokument določa minimalne zahteve za varno in neodvisno uporabo dvigal, namenjenih za osebe, vključno z invalidi, ter dostop do njih. Obravnava potrebe invalidov v skladu z dodatkom A.
OPOMBA: Za smernice o rešitvah za boljšo dostopnost in uporabnost glej dodatek D.

General Information

Status
Published
Publication Date
24-Aug-2022
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
22-Jul-2022
Due Date
26-Sep-2022
Completion Date
25-Aug-2022

Relations

Buy Standard

Standard
EN 81-70:2021+A1:2022
English language
33 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 81-70:2021+A1:2022
01-oktober-2022
Varnostna pravila za konstruiranje in vgradnjo dvigal (liftov) - Posebne izvedbe
osebnih in osebno-tovornih dvigal - 70. del: Dostopnost dvigal za osebe, vključno
z invalidi
Safety rules for the construction and installation of lifts - Particular applications for
passenger and goods passenger lift - Part 70: Accessibility to lifts for persons including
persons with disability
Sicherheitsregeln für die Konstruktion und den Einbau von Aufzügen - Besondere
Anwendungen für Personen- und Lastenaufzüge - Teil 70: Zugänglichkeit von Aufzügen
für Personen einschließlich Personen mit Behinderungen
Règles de sécurité pour la construction et l'installation des élévateurs - Applications
particulières pour les ascenseurs et ascenseurs de charge - Partie 70 : Accessibilité aux
ascenseurs pour toutes les personnes y compris les personnes avec handicap
Ta slovenski standard je istoveten z: EN 81-70:2021+A1:2022
ICS:
91.140.90 Dvigala. Tekoče stopnice Lifts. Escalators
SIST EN 81-70:2021+A1:2022 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN 81-70:2021+A1:2022

---------------------- Page: 2 ----------------------
SIST EN 81-70:2021+A1:2022


EN 81-70:2021+A1
EUROPEAN STANDARD

NORME EUROPÉENNE

July 2022
EUROPÄISCHE NORM
ICS 91.140.90 Supersedes EN 81-70:2021
English Version

Safety rules for the construction and installation of lifts -
Particular applications for passenger and goods passenger
lift - Part 70: Accessibility to lifts for persons including
persons with disability
Règles de sécurité pour la construction et l'installation Sicherheitsregeln für die Konstruktion und den Einbau
des élévateurs - Applications particulières pour les von Aufzügen - Besondere Anwendungen für
ascenseurs et ascenseurs de charge - Partie 70 : Personen- und Lastenaufzüge - Teil 70: Zugänglichkeit
Accessibilité aux ascenseurs pour toutes les personnes von Aufzügen für Personen einschließlich Personen
y compris les personnes avec handicap mit Behinderungen
This European Standard was approved by CEN on 12 January 2021 and includes Amendment 1 approved by CEN on 8 May 2022.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.

This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.





EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2022 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 81-70:2021+A1:2022 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------
SIST EN 81-70:2021+A1:2022
EN 81-70:2021+A1:2022 (E)
Contents Page
European foreword . 3
0 Introduction . 5
1 Scope . 6
2 Normative references . 6
3 Terms and definitions . 6
4 Significant hazards and barriers to accessibility . 6
5 Safety requirements and/or protective measures . 7
5.1 General . 7
5.2 Entrances – Door openings . 8
5.3 Car dimensions and equipment in the car . 8
5.3.1 Car dimensions . 8
5.3.2 Equipment in the car . 11
5.4 Control devices and signals . 12
5.4.1 General . 12
5.4.2 Control devices and signals for collective control systems . 13
5.4.3 Control devices and signals for destination control systems . 17
6 Verification of safety requirements and/or protective measures . 19
7 Information for use . 22
Annex A (normative) Categories of disability considered . 23
Annex B (normative) Extra large control devices . 24
Annex C (normative) Touch screen devices for destination control systems . 26
Annex D (informative) Guidance for increased accessibility and usability . 27
Annex E (informative) Determination of luminance contrast and light reflectance values . 28
Annex ZA (informative) Relationship between this European Standard and the essential
requirements of Directive 2014/33/EU aimed to be covered . 32
Bibliography . 33

2

---------------------- Page: 4 ----------------------
SIST EN 81-70:2021+A1:2022
EN 81-70:2021+A1:2022 (E)
European foreword
This document (EN 81-70:2021+A1:2022) has been prepared by Technical Committee CEN/TC 10 “Lifts,
escalators and moving walks”, the secretariat of which is held by AFNOR.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by January 2023, and conflicting national standards shall
be withdrawn at the latest by July 2024.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document includes Amendment 1 approved by CEN on 8 May 2022.
This document supersedes !EN 81-70:2021".
The start and finish of text introduced or altered by amendment is indicated in the text by tags !".
This document has been prepared under a Standardization Request given to CEN by the European
Commission and the European Free Trade Association, and supports essential requirements of
EU Directive(s) / Regulation(s).
For relationship with EU Directive(s) / Regulation(s), see informative Annex ZA, which is an integral part
of this document.
In comparison with !EN 81-70:2018", the following significant changes have been made:
— Clarification of relationship to other EN 81 standards;
— Information on building related issues deleted;
— Information in assumptions on negotiations deleted;
— Scope editorially modified;
— Normative references updated;
— References to negotiations in Clause 5 deleted;
— Optional use of additional control devices deleted;
— References to EN 81-20 and EN 81-28 deleted in verification table;
— Content of information for use updated;
— Annex ZA is modified;
— Bibliography updated.
!The need for this Amendment 1 was based on the following points:
— Modified requirements on luminance contrast by changing from LRV difference to Michelson
contrast for symbols to their background;
— Addition of requirement for illumination of control devices;
3

---------------------- Page: 5 ----------------------
SIST EN 81-70:2021+A1:2022
EN 81-70:2021+A1:2022 (E)
— New Annex for guidance on measurement of luminance contrast."
The content of this document provides the enhanced design rules, examinations and tests for lifts which
are intended to be used by persons including persons with disability. This document can only be used in
conjunction with the EN 81-20:2020 which gives the basic requirements for passenger and goods
passenger lifts.
This document is part of the EN 81 series of standards. The structure of the EN 81 series is described in
CEN/TR 81-10:2008.
Any feedback and questions on this document should be directed to the users’ national standards body.
A complete listing of these bodies can be found on the CEN website.
According to the CEN-CENELEC Internal Regulations, the national standards organizations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia,
Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland,
Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of North
Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United
Kingdom.
4

---------------------- Page: 6 ----------------------
SIST EN 81-70:2021+A1:2022
EN 81-70:2021+A1:2022 (E)
0 Introduction
0.1 General
This document is a type C standard as stated in EN ISO 12100:2010.
The lifts concerned and the extent to which hazards, hazardous situations or hazardous events are
covered is indicated in the scope of this standard.
When provisions of this type C standard are different from those which are stated in type A or B
standards, the provisions of this type C standard take precedence over the provisions of the other
standards for lifts that have been designed and built according to the provisions of this type C standard.
0.2 Principles
For the revision of this document the following have been considered:
a) practical experience with the first version of this standard;
b) market demand for including new technology;
c) CEN-CENELEC Guide 6;
d) current legal framework for accessibility and usability, in particular:
The non-discrimination clause (art 6a) based on disability and age of Article 19 of consolidated
version 2016 of the Treaty of Lisbon of the European Union requests a new understanding of
diversity of users in the built environment, transport and products, similar to that established in
information and communication technologies.
The UN Convention on the Rights of Persons with Disabilities with reference also to accessibility in
the built environment – considering human diversity, social inclusion and equality for all people - is
the first ratified EU agreement on human rights and ratified also by most Member States. It is also
the first international legally binding instrument on human rights setting minimum standards for the
rights for people with disabilities around the world.
5

---------------------- Page: 7 ----------------------
SIST EN 81-70:2021+A1:2022
EN 81-70:2021+A1:2022 (E)
1 Scope
This document specifies the minimum requirements for the safe and independent access and use of lifts
by persons, including persons with disabilities. It covers the needs of persons with disabilities according
to Annex A.
NOTE For guidance on solutions for increased accessibility and usability, see Annex D.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 81-20:2020, Safety rules for the construction and installation of lifts - Lifts for the transport of persons
and goods - Part 20: Passenger and goods passenger lifts
EN ISO 12100:2010, Safety of machinery - General principles for design - Risk assessment and risk reduction
(ISO 12100:2010)
ISO 4190-5:2006, Lift (Elevator) installation - Part 5: Control devices, signals and additional fittings
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN ISO 12100:2010, EN 81-20:2020
and the following apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
• ISO Online browsing platform: available at https://www.iso.org/obp
• IEC Electropedia: available at http://www.electropedia.org/
3.1
collective control system
lift control system where required direction of travel is registered on the landing and the destination floor
is registered in the car
3.2
destination control system
lift control system where the destination floor is registered on the landing
3.3
accessibility button
means to activate enhanced accessibility features or services for a single trip
4 Significant hazards and barriers to accessibility
This clause contains all significant hazards, hazardous situations and events as far as they are dealt with
in this standard, identified by risk assessment as significant for this type of machinery and which require
actions to eliminate or reduce the risk (see Table 1).
In this document, barriers to accessibility and additional risks encountered by the person with disability
or by the devices used by that person are identified particularly in Table 1, No 8 (ergonomic hazards).
6

---------------------- Page: 8 ----------------------
SIST EN 81-70:2021+A1:2022
EN 81-70:2021+A1:2022 (E)
Table 1 — List of significant hazards
No Hazards listed in EN ISO 12100:2010, Relevant clauses
Annex B
1 Mechanical hazards due to:
 Crushing 5.3.2.3
 Impact 5.3.2.3
 Slip, trip, fall 5.3.2.4
8 Ergonomic hazards due to:
 Access 5.2.1, 5.2.2, 5.3.1, 5.3.2.3
 Design or location of indicators, visual and 5.1.3, 5.4.2.4, 5.4.2.5, 5.4.3.3,
audible display units 5.4.3.4
 Design, location or identification of control 5.1.2, 5.4.2.1, 5.4.2.2, 5.4.2.3,
devices 5.4.3.1, 5.4.3.2
 Effort 5.3.2.1, 5.3.2.2
5 Safety requirements and/or protective measures
5.1 General
5.1.1 Passenger and goods passenger lifts shall comply with the safety requirements and/or protective
measures of the following clauses. In addition, passenger and goods passenger lifts shall be designed
according to the principles of EN ISO 12100:2010 for relevant but not significant hazards which are not
dealt with by this document.
5.1.2 !Where luminance contrast between adjacent surfaces is required, it shall comply with Table 2.
Table 2 — Requirements for luminance contrast
Minimum light
Minimum Minimum light
reflectance
luminance reflectance
Clause Item value point Viewing angle
contrast       value of lighter
difference LRV –
1
C [%] surface LRV
M 1
LRV
2
Table 4, item c) Active part of 30 - - 45° above
push buttons to horizontal
their
surrounding
Table 4, item d) Face plates to 30 - - Horizontal
their
surrounding
Table 4, item j) Symbols on push - 50 50 45° above
buttons to active horizontal
areas
5.4.3.3 c) Lift designation - 50 50 Horizontal
markings to
background
7

---------------------- Page: 9 ----------------------
SIST EN 81-70:2021+A1:2022
EN 81-70:2021+A1:2022 (E)
NOTE 1 For determination of luminance contrast (Michelson contrast C ) and light reflectance values (LRV), see
M
informative Annex E. For further guidance on contrast, see ISO 21542:2021, 5.3 and Annex E.
NOTE 2 On shiny and direct reflective surfaces, unfavourable reflections can reduce luminance contrast. Light
colour tones for ceiling and wall surfaces, diffuse reflective materials and a wide light distribution prevent
disturbing reflections on the control devices."
5.1.3 When an audible signal or voice announcement is required, the sound level shall be adjustable
between 35 dB(A) and at least 65 dB(A) to suit the site conditions. In noisy environments (e.g. on landings
in train stations) the maximum sound level shall be adjustable up to 80 dB(A). The means of adjustment
shall be accessible only to authorized persons.
5.2 Entrances – Door openings
5.2.1 The landing and car doors shall be automatic power operated horizontally sliding doors.
The clear opening width shall be at least 800 mm for type 1 cars, 900 mm for type 2, type 3 and type 4
cars and 1 100 mm for type 5 cars. In existing buildings, the clear opening width shall be at least 800 mm
for type 2 cars.
5.2.2 The door dwell time shall be adjustable at least between 2 s and 20 s to suit the conditions where
the lift is installed. The means of adjustment shall be accessible only to authorized persons.
NOTE A door dwell time of at least 6 s is needed for persons with reduced mobility (see also 5.4.2.2.3).
A door close button may be provided to reduce the door dwell time.
5.3 Car dimensions and equipment in the car
5.3.1 Car dimensions
The inside dimensions of cars with a single entrance or with two opposite or two adjacent entrances shall
be chosen in accordance with Table 3.
Car dimensions shall be measured between the structural car walls. Decorative finishes on each wall that
reduce the minimum car dimensions given by Table 3 shall not exceed 15 mm in thickness.
There shall be no additional features attached to the car walls below a height of 800 mm which may
restrict the accommodation and turning of passengers using wheelchairs or passengers with other
walking aids. This would particularly be the case for type 1 and type 2 cars restricting the minimum depth
and for type 4 cars restricting the smaller minimum dimension.
8

---------------------- Page: 10 ----------------------
SIST EN 81-70:2021+A1:2022
EN 81-70:2021+A1:2022 (E)
Table 3 — Minimum car dimensions for cars with a single entrance or two entrances
Minimum car Accessibility
Building types, usage Remarks
a
dimensions level
Car width: This car Shall only be used in existing Type 1 provides only limited
1 000 mm accommodates buildings where building accessibility for persons using
one wheelchair constraints do not permit the a manual wheelchair as
Car depth:
user without an installation of a type 2 car. described in EN 12183:2014
1 300 mm
Type of
accompanying or an electrically powered

(450 kg)
car
person. wheelchair of class A

1
described in EN 12184:2014.
This type also provides
accessibility for persons using
walking aids (e.g. a walking
stick) and for persons with
sensory and intellectual
disabilities.
2 Car width: This car Shall be the minimum size for Type 2 provides accessibility
1 100 mm accommodates new buildings. for persons using a manual
one wheelchair wheelchair as described in
Car depth:
user and an EN 12183:2014 or an
1 400 mm
accompanying electrically powered
(630 kg)
person. wheelchair of class A or B as
described in EN 12184:2014.
This type also provides
accessibility for persons using
walking aids (e.g. walking
sticks, crutches or rollators).
Passengers with wheelchairs
or walking aids are unlikely to
be able to turn around in this
type of car and have to leave
the car backwards.
3 Car width: This car Recommended size for cars in Type 3 provides accessibility
1 100 mm accommodates public areas (e.g. outdoor for persons using a manual
one user with a facilities, stations, etc.) and for wheelchair as described in
Car depth:
wheelchair of cars where transport of EN 12183:2014 or an
2 100 mm
class C and some wheelchairs of class C shall be electrically powered
(1 000 kg)
other
provided wheelchair of class A, B or C
passengers. It described in EN 12184:2014.
also allows
It also provides accessibility
transport of
for persons using a manual
stretchers.
wheelchair with tractor unit
(propulsion attachment).
When cars of this type are
configured with two opposite
entrances this can provide
straight through circulation
from the main entrance to
different floor levels.
9

---------------------- Page: 11 ----------------------
SIST EN 81-70:2021+A1:2022
EN 81-70:2021+A1:2022 (E)
Minimum car Accessibility
Building types, usage Remarks
a
dimensions level
Car width: This car Shall only be used in existing Type 1 provides only limited
1 000 mm accommodates buildings where building accessibility for persons using
one wheelchair constraints do not permit the a manual wheelchair as
Car depth:
user without an installation of a type 2 car. described in EN 12183:2014
1 300 mm
Type of
accompanying or an electrically powered

(450 kg)
car
person. wheelchair of class A

1
described in EN 12184:2014.
This type also provides
accessibility for persons using
walking aids (e.g. a walking
stick) and for persons with
sensory and intellectual
disabilities.
4 Car width: This car Shall be the minimum size for Type 4 provides accessibility
1 600 mm accommodates cars with doors on adjacent for persons using a manual
b
one wheelchair walls . wheelchair as described in
Car depth:
user and a few EN 12183:2014 or an
1 400 mm
other electrically powered
or
passengers. It wheelchair of class A or B as
Car width:
also allows a described in EN 12184:2014.
1 400 mm
wheelchair to be
Type 4 provides sufficient
rotated within
Car depth:
space for most wheelchairs
1 600 mm the car.
users and for passengers with
(1 000 kg) walking aids.
5 Car width: This car  Type 5 provides accessibility
2 000 mm accommodates for persons using a manual
one wheelchair wheelchair as described in
Car depth:
user and several EN 12183:2014 or an
1 400 mm
other electrically powered
or
passengers. It wheelchair of class A, B or C as
Car width:
also allows a described in EN 12184:2014.
1 400 mm
wheelchair to be
Type 5 provides sufficient
rotated within
Car depth:
turning space for persons
2 000 mm the car.
using wheelchairs of class A or
(1 275 kg) B and for persons using
walking aids (e.g. walking
frames, rollators, etc.).
a
The car width is defined as the horizontal distance between the inner surface of the structural walls of the car, measured parallel
to the front entrance. The car depth is defined as the horizontal distance between the inner surfaces of the structural walls of the
car, measured perpendicular to the width.
b
The distances between doors and adjacent car walls as shown in Figure 1 should be as large as possible.
10

---------------------- Page: 12 ----------------------
SIST EN 81-70:2021+A1:2022
EN 81-70:2021+A1:2022 (E)

Key
a distance between door and adjacent car wall
Figure 1 — Cars with doors on adjacent walls
5.3.2 Equipment in the car
5.3.2.1 A handrail shall be installed on the side wall where the car operating panel is located as
follows:
a) the handrail shall be interrupted where the car operating panel is located in order to avoid
obstructing control devices;
b) the handrail may only be installed on one side of the car operating panel if the shorter side would not
accommodate a handrail with an overall length of at least 400 mm;
c) the gripping part of the handrail shall have cross-sectional dimensions between 30 mm and 45 mm
with a minimum radius of 10 mm (see Figure 2);
d) the distance between the wall and the gripping part of the handrail shall be at least 35 mm;
e) the height of the top edge of the gripping part of the handrail shall be 900 mm ± 25 mm from the
finished floor level;
f) the ends of the handrails shall be closed. Where there is a risk of collision with the projecting ends,
e.g. where the handrail is interrupted in front of the car operating panel, the handrail shall return
towards the wall.
For car types 1, 2 and 3, the handrail may be installed on the opposite side wall if the handrail would
restrict the car entrance width.
For car types 4 and 5 a second handrail shall be installed on the opposite side wall or on the rear wall.
11

---------------------- Page: 13 ----------------------
SIST EN 81-70:2021+A1:2022
EN 81-70:2021+A1:2022 (E)
Dimensions in millimetres

Key
1 maximum outer circle for handrail profile
2 minimum inner circle for handrail profile
Figure 2 — Cross sectional dimensions of handrails
5.3.2.2 Where a tip-up seat is provided in the car it shall have the following characteristics:
a) a height from the finished floor level of 500 mm ± 25 mm;
b) a depth of 300 mm to 400 mm;
c) a width of 400 mm to 500 mm;
d) an ability to support a load of at least 120 kg.
5.3.2.3 For car types 1, 2 and 3, a device shall be installed to enable passengers to observe obstacles
behind them when moving backwards out of the car.
5.3.2.4 The car floor shall be slip-resistant, taking into consideration the environment in which the
lift is installed, in particular where passengers with wet shoes are regularly expected to enter the car. The
same material as used in the lift lobbies may be used for the lift car floor.
5.3.2.5 !Lighting shall provide a minimum illuminance of 100 lx in the plane of the item which
can be vertical or tilted."
5.4 Control devices and signals
5.4.1 General
5.4.1.1 Control devices for collective control systems
Collective control systems shall be used in general applications.
The following control devices according to 5.4.2 shall be used:
— push buttons on landings and in the car; or
— extra large push buttons on landings and in the car; or
12

---------------------- Page: 14 ----------------------
SIST EN 81-70:2021+A1:2022
EN 81-70:2021+A1:2022 (E)
— push buttons on landings, keypads in the car for floor selection and push buttons in the car for other
control operations.
NOTE For buildings with many landings, keypad-devices can help to fulfil the requirements of Table 5.
5.4.1.2 Control devices for destination control systems
Destination control systems may only be used where guidance to passengers about the specific
operational features of the lift can be ensured.
NOTE Due to their complexity, destination control systems provide a lower level of accessibility for some
passengers than collective control systems, particularly where a touch screen with an accessibility button and
associated acoustic menu is used. When using the acoustic menu, passengers are required to listen, understand and
react to audible information within a specific time period.
The following control devices according to 5.4.3 shall be used:
— keypads and if applicable accessibility buttons on landings, and push buttons in the car; or
— touch screens and accessibility buttons on landings, and push buttons in the car.
5.4.2 Control devices and signals for collective control systems
5.4.2.1 Requirements for design and arrangement of control devices
Requirements for the design of control devices are given in Table 4 and requirements for the
arrangement of control devices are given in Table 5.
13

---------------------- Page: 15 ----------------------
SIST EN 81-70:2021+A1:2022
EN 81-70:2021+A1:2022 (E)
Table 4 — Control devices-Requirements for design
# Subject Landing controls devices Car controls devices
2
a) Minimum area of active part 490 mm
of push buttons
b) Minimum dimension of active Inscribed circle with a diameter of 20 mm
part of push buttons
c) Identification of active part of Identifiable visually (by contrast, see 5.1.2) and by touch
push buttons (protruded) from face plate or immediate surrounds
d) Identification of face plate Luminance contrast to its Luminance contrast to its
a
surrounds (see 5.1.2) surrounds (see 5.1.2) in case of
less than 5 buttons
e) Operating force 2,5 N to 5,0 N
f) Operating feedback Required to inform passengers that the button, once pushed, has
been operated (e.g. button possesses perceivable movement or is
provided with a system of mechanical feedback)
g) Registration feedback Required to inform passengers that the call or function has been
registered by visible and audible signal. The audible signal shall
comply with 5.1.3 and shall be given on every individual operation of
button even if the call is already registered.
h) Button fo
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.