IEC/SC 23A - IEC_SC_23A
To prepare international standards for products and systems used for the management of all types of cables, information and communication lines, electrical power distribution conductors and associated accessories. Management includes support and/or containment and/or retention and/or protection against external influences.
IEC_SC_23A
To prepare international standards for products and systems used for the management of all types of cables, information and communication lines, electrical power distribution conductors and associated accessories. Management includes support and/or containment and/or retention and/or protection against external influences.
General Information
IEC 62275:2018 specifies requirements for metallic, non-metallic and composite cable ties and their associated fixing devices used for the management and support of wiring systems in electrical installations. This third edition cancels and replaces the second edition published in 2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) consideration of adhesive fixing devices, b) revised and updated normative references, c) modified definitions for metallic and composite cable ties, d) new definitions, e) improvement of test procedures, f) new figures for typical arrangement of test assembly for fixing devices and for integral fixing devices.
- Standard45 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 63355:2022 specifies a method for the determination of the content of halogens in cable management system (CMS) products or system components made completely or partly of combustible material(s). The determination is made by combustion and subsequent analysis of the combustion product by ion chromatography. This document specifies how CMS products or system components can be declared as halogen-free.
- Standard19 pagesEnglish languagesale 10% offe-Library read for1 day
2018-11-02 - assessment is now 'compliant', BT route to be followed to adress annex ZZ
2018-08-13: non complinat assessment
2018-05-18 - Sent to HAS
2018-03-22 - TC request to BT to keep ratification pending until Annex ZZ is available
(TC213 Plenary decision to prepare Annex ZZ and associated risk assessment for submission to CCMC and to update BT (See Decision 2 in TC213/Sec1214/RM).
2017-05-16 - Cannot allocate for publication due to missing assessment from Consultant.
2016-12-12 - Annex ZZ delivered by TC and to be sent to Consultant when FDIS starts and included in lt file for NC's voting period.
- Amendment13 pagesEnglish languagesale 10% offe-Library read for1 day
This International Standard specifies requirements and tests for cable cleats used for securing cables in electrical installations and for intermediate restraints used for holding cables together in formation in electrical installations. Cable cleats provide resistance to electromechanical forces where declared. This document includes cable cleats that rely on a mounting surface specified by the manufacturer for axial and/or lateral retention of cables. Various types of cable cleats and intermediate restraints are shown in Annex A. NOTE Requirements for manufacturers in this document also apply to importers and responsible vendors where appropriate. This document does not apply to cable ties.
- Standard45 pagesEnglish languagesale 10% offe-Library read for1 day
Not available
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
Not available
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
Clause 1 of IEC 61386-1:2008 is applicable, except as follows: Addition: This part of IEC 61386 specifies the requirements for flexible conduit systems.
- Standard16 pagesEnglish languagesale 10% offe-Library read for1 day
Clause 1 of IEC 61386-1:2008 is applicable, except as follows: Addition: This part of IEC 61386 specifies the requirements for rigid conduit systems.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
Clause 1 of IEC 61386-1:2008 is applicable, except as follows: Addition: This part of IEC 61386 specifies the requirements for pliable conduit systems including self-recovering conduit systems.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
NEXT ACTION: TB ACTION
2020-07-01: TC 213 request to delay ratification until A11 is available
2019-09-23 PeC: LVD "lack of compliance"
2019-08-27 PeC: sent for LVD assessment
- Amendment12 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 61534 specifies general requirements and tests for powertrack (PT) systems with a rated voltage not exceeding 277 V a.c. single phase, or 480 V a.c. two or three phase 50 Hz/60 Hz with a rated current not exceeding 63 A. These systems are used for distributing electricity in household, commercial and industrial premises.
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61534-21:2014 specifies the particular requirements and tests for PT systems intended for mounting on walls and/or ceiling. They may be installed flush or semi-flush, surface mounted, suspended or spaced away from the surface using fixing devices. This second edition cancels and replaces the first edition published in 2006 and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - Clauses 18 to 22 have been adapted to IEC 61534-1:2011 and include short-circuit test requirements; - Additional classification, terms and requirements for wall powertrack (PT) systems mounted at the skirting level (close to the floor) position. This publication is to be read in conjunction with IEC 61534-1:2011.
- Standard13 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard13 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61534-22:2014 specifies the particular requirements and tests for PT systems intended for mounting on, or under the floor level and floor service units which are mounted on the floor, under the floor or flush with the floor. This second edition cancels and replaces the first edition published in 2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - Clauses 18 to 22 have been adapted to IEC 61534-1:2011 and include short-circuit test requirements; - addition of a new (500 N) classification for the resistance to traffic load applied to small surface areas on a flushfloor service unit; - addition of a new classification for the non-automatic closing of the lid on flushfloor service units and appropriate tests; - addition of tests for floor service units declared for use when a floor is wet treated. This publication is to be read in conjunction with IEC 61534-1:2011.
- Standard24 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62549:2011 specifies requirements and tests for systems with adaptable linear geometry for cable guiding intended for the accommodation and retention of cables and possibly other electrical equipment in electrical and/or communication systems installations. The maximum voltage of these installations is 1 000 V a.c. and 1 500 V d.c. This standard does not apply to cable trunking systems, cable ducting systems, conduit systems, cable tray systems, cable ladder systems, powertrack systems, energy conveying chains or equipment covered by other standards.
- Standard44 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61386-25:2011 specifies requirements and tests for conduit fixing devices used for support and/or retention of conduit for cable management. This publication is to be read in conjunction with IEC 61386-1:2008.
- Standard20 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61534-1:2011 specifies general requirements and tests for powertrack (PT) systems with a rated voltage not exceeding 277 V a.c. single phase, or 480 V a.c. two or three phase 50 Hz/60 Hz with a rated current not exceeding 63 A. These systems are used for distributing electricity in household, commercial and industrial premises. This second edition cancels and replaces the first edition published in 2003 and constitutes a technical revision. The main changes from the previous edition are as follows: - updated normative references (Clause 2); - changes to the number of samples to be tested (Subclause 5.3); - inclusion of a short circuit test (New Clause 18); - changes to external influences (Clause 21).
- Standard71 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard71 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62444:2010 provides requirements and tests for the construction and performance of cable glands. This standard covers complete cable glands as supplied by the manufacturer or the supplier responsible for placing the product on the market. This standard does not cover cable glands for mineral insulated cables. This standard covers cable glands with IEC 60423 metric entry threads. This standard can be used as a guide for cable glands with other type of entry threads.
- Standard33 pagesEnglish languagesale 10% offe-Library read for1 day
This standard specifies requirements and tests for conduit systems buried underground including conduits and conduit fittings for the protection and management of insulated conductors and/or cables in electrical installations or in communication systems. This standard applies to metallic, non-metallic and composite systems including threaded and non-threaded entries which terminate the system.
- Standard19 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements and tests for cable trunking systems (CTS) and cable ducting systems (CDS) intended for the accommodation, and where necessary for the electrically protective separation, of insulated conductors, cables and possibly other electrical equipment in electrical and/or communication systems installations. The maximum voltage of these installations is 1 000 V a.c. and 1 500 V d.c. Service poles and service posts are intended to be mounted in free space and in contact with mounting surface(s) only at one or two ends, where the word “mounted” means fixed or placed on the floor with a weighted base or linked to a mounting surface through a flexible component. NOTE Service poles and service posts can also be part of a CTS/CDS intended for wall or ceiling mounting covered by Part 2 1 or floor mounting covered by Part 2-2 and are then also tested according to Part 2-1 and/or Part 2-2 as appropriate. This European Standard does not apply to conduit systems, cable tray systems, cable ladder systems, powertrack systems or equipment covered by other standards. This European Standard shall be used in conjunction with EN 50085-1:2005 “Cable trunking systems and cable ducting systems for electrical installations – Part 1: General requirements” which is referred to in this document as Part 1.
- Standard27 pagesEnglish languagesale 10% offe-Library read for1 day
Replacement: This European Standard specifies requirements and tests for cable trunking systems (CTS) and cable ducting systems (CDS) intended for the accommodation, and where necessary for the electrically protective separation, of insulated conductors, cables and possibly other electrical equipment in electrical and/or communication systems installations. The maximum voltage of these installations is 1 000 V a.c. and 1 500 V d.c. These systems are intended for mounting underfloor, flushfloor or onfloor. This standard does not apply to CTS/CDS which are intended to be fixed to the wall and supported by the floor. This standard does not apply to conduit systems, cable tray systems, cable ladder systems, power track systems or equipment covered by other standards. This standard shall be used in conjunction with EN 50085-1:2005, Cable trunking systems and cable ducting systems for electrical installations – Part 1: General requirements, which is referred to in this document as Part 1.
- Standard31 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 61386 specifies requirements and tests for conduit systems, including conduits and conduit fittings, for the protection and management of insulated conductors and/or cables in electrical installations or in communication systems up to 1 000 V a.c. and/or 1 500 V d.c. This second edition cancels and replaces the first edition published in 1996, and its Amendment 1 (2000), and it constitutes a technical revision. The changes to the first edition are as follows: - change to the length of the test specimen between fittings for the tensile test, - editorial and normative reference updates.
- Standard42 pagesEnglish languagesale 10% offe-Library read for1 day
Amandma A11:2011 je dodatek k standardu SIST EN 61386-22:2004
Specifies the requirements for pliable conduit systems including self-recovering conduit systems.
- Amendment2 pagesEnglish languagesale 10% offe-Library read for1 day
This International Standard specifies outside diameters for conduits used in electrical installations or in communication systems and the dimensional requirements for threads. It also specifies the dimensional requirements for threads used in associated fittings. It is not applicable to extra heavy-duty electrical rigid steel conduits specified in IEC 60981. This third edition cancels and replaces the second edition published in 1993. This edition constitutes a technical revision. The following main changes have been made to the second edition: -revised figures and tables plus editorial and normative reference updates -conduit range increased to 110 mm outside diameter.
- Standard16 pagesEnglish languagesale 10% offe-Library read for1 day
This International Standard specifies requirements and tests for cable tray systems and cable ladder systems intended for the support and accommodation of cables and possibly other electrical equipment in electrical and/or communication systems installations. Where necessary, cable tray systems and cable ladder systems may be used for the division or arrangement of cables into groups.
- Standard85 pagesEnglish languagesale 10% offe-Library read for1 day
Replacement: This European Standard specifies requirements and tests for cable trunking systems (CTS) and cable ducting systems (CDS) intended for the accommodation, and where necessary for the electrically protective separation, of insulated conductors, cables and possibly other electrical equipment in electrical and/or communication systems installations. The maximum voltage of these installations is 1 000 V a.c. and 1 500 V d.c. These systems are intended for mounting on walls and/or ceilings. They may be embedded, installed in a flush or semi-flush state, surface mounted or mounted away from the surface using fixing devices. This standard does not apply to conduit systems, cable tray systems, cable ladder systems, power track systems or equipment covered by other standards. This standard shall be used in conjunction with EN 50085-1:2005: Cable trunking systems and cable ducting systems for electrical installations - Part 1 General requirements which is referred to in this document as Part 1.
- Standard24 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements and tests for cable trunking systems (CTS) and cable ducting systems (CDS) intended for the accommodation, and where necessary for the electrically protective separation, of insulated conductors, cables and possibly other electrical equipment in electrical and/or communication systems installations. The maximum voltage of these installations is 1 000 V a.c. and 1 500 V d.c. This standard does not apply to conduit systems, cable tray systems, cable ladder systems, power track systems or equipment covered by other standards. This Part 1 shall be used in conjunction with the relevant Part 2 for particular requirements. NOTE This Part 1 is not intended to be used by itself.
- Standard43 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62275:2022 specifies requirements for metallic, non-metallic and composite cable ties and their associated fixing devices as a means used for managing or securing the wiring systems in electrical installations. Cable ties and associated fixing devices can also be suitable for other applications, such as support of wiring systems, and where so used, additional requirements can apply. This fourth edition cancels and replaces the third edition published in 2018. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - scope clarification, - new definitions, - deletion of the exception for the stabilization of the moisture content, - possibility to carry out tensile strength tests with dead weights, - differentiation of rubber and acrylic adhesive fixings, - clarification for mechanical testing of integral devices, - clarifications on Table 6, - clarifications in 9.1, - the minimum installation temperature test for cable ties is carried out only when the declared minimum temperature is lower than 0 °C, - a requirement that metallic cable ties be classified according to 6.2.3, - definition of colours to be tested for contribution to fire, - addition of a "some countries" note in Clause 10, - clarification of the mounting of fixing devices in the resistance to ultraviolet light test, - clarification on the testing of integral devices in the resistance to ultraviolet light test.
- Draft40 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61914:2015 is available as IEC 61914:2015 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61914:2015 specifies requirements and tests for cable cleats and intermediate restraints used for securing cable in electrical installations. Cable cleats provide resistance to electromechanical forces where declared. This standard includes cable cleats that rely on a mounting surface specified by the manufacturer for axial and/or lateral retention of cables. This second edition cancels and replaces the first edition published in 2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Additional declaration and test for lateral load retention depending on cleat mounting orientation with associated new figures; b) Additional declaration of the distance between the cable centres in any short-circuit test and associated new figures; c) Specification of the cable to be used in short-circuit testing and relaxation of the ambient temperature limits for the test; d) Additional requirement to photograph the short-circuit test arrangement before and after the test and to record more complete details of the cable used; e) Revised parameters for the test of resistance to UV light. This edition also includes the following editorial changes with respect to the previous edition: f) Revised and updated normative references and bibliography; g) Editorial clarification of definitions; h) Editorial clarification of procedures for selection of test samples and the testing of cleats designed for more than one cable; i) Relaxation of some mandrel material requirements; j) Clarification of the inspection requirements following a short-circuit test and adding the option of either a.c. or d.c. voltage testing following a second short-circuit; k) Clarification that the resistance to corrosion test applies to all types of fixing; l) New cleat example illustration; m) Limitations of use of the formulae in Annex B added.
- Standard31 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62275:2013 specifies requirements for metallic, non-metallic and composite cable ties and their associated fixing devices used for the management and support of wiring systems in electrical installations. This second edition cancels and replaces the first edition published in 2006 and constitutes a technical revision. It incorporates additional tables, an annex and figures as well as revisions to such that appeared in the first edition. In places the text has been substantially altered including: - revised and updated normative references, - integral cable ties and fixing devices, - change in the range of the diameter of the test mandrel, - general notes on tests, - mechanical properties and associated tests as well as tests for resistance to ultraviolet light and corrosion.
- Standard37 pagesEnglish languagesale 10% offe-Library read for1 day
Amandma A11:2011 je dodatek k standardu SIST EN 61386-23:2004
Specifies the requirements for flexible conduit systems.
- Amendment2 pagesEnglish languagesale 10% offe-Library read for1 day
Amandma A11:2011 je dodatek k standardu SIST EN 61386-21:2004
Specifies the requirements for rigid conduit systems. A conduit system which complies with this standard is deemed safe for use when installed in accordance with national wiring regulations, whilst applying the manufacturer's installation instructions and conduit classification.
- Amendment2 pagesEnglish languagesale 10% offe-Library read for1 day
This International Standard specifies requirements for metallic, non-metallic and composite cable ties and their associated fixing devices used for the management and support of wiring systems in electrical installations. Cable ties and associated fixing devices may also be suitable for other applications and where so used, regard should be taken of any additional requirements.
- Standard31 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard establishes the requirements and tests for cover plates and cover tapes used for the mechanical protection, identification and warning of the location of buried cables or buried conduits in underground installations. NOTE This European Standard does not apply to meshes and tapes falling under EN 12613.
- Standard14 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61914:2009 specifies requirements and tests for cable cleats and intermediate restraints used for securing cable in electrical installations. Cable cleats provide resistance to electromechanical forces where declared. This standard includes cable cleats that rely on a mounting surface specified by the manufacturer for axial and/or lateral retention of cables.
- Standard31 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61534-22:2009 applies to PT systems which are intended to be mounted on, or under the floor level and floor service units which are mounted on the floor, under the floor or flush with the floor. This standard is to be used in conjunction with IEC 61534-1:2003, Powertrack systems - Part 1: General requirements.
- Standard22 pagesEnglish languagesale 10% offe-Library read for1 day
This standard specifies the particular requirements and tests for PT systems intended for mounting on walls and/or ceiling. They may be installed flush or semi-flush, surface mounted, suspended or spaced away from the surface using fixing devices.
- Standard11 pagesEnglish languagesale 10% offe-Library read for1 day
Supersedes EN 50086-2-2:1995 + A11:1998 * Corrigendum to EN issued April 2004
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61386-21:2002 specifies the requirements for rigid conduit systems. This part 21, which specifies particular requirements for rigid conduit systems, is to be used in conjunction with IEC 61386-1, Conduit systems for electrical installations – Part 1: General requirements, and its amendments. It was established on the basis of the first edition (1996) of that standard and its amendment 1 (2000).
- Standard19 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61386-23:2002 specifies the requirements for flexible conduit systems. This part 23, which specifies particular requirements for flexible conduit systems, is to be used in conjunction with IEC 61386-1, Conduit systems for cable installations – Part 1: General Requirements 1, and its amendments. It was established on the basis of the first edition (1996) of that standard and its amendment 1 (2000).
- Standard16 pagesEnglish languagesale 10% offe-Library read for1 day
This part of EN 61534 specifies general requirements and tests for powertrack (PT) systems with a rated voltage not exceeding 277 V a.c. single phase, or 480 V a.c. two or three phase 50 Hz/60 Hz, with a rated current not exceeding 63 A. These systems are used for distributing electricity in household, commercial and industrial premises.
- Standard65 pagesEnglish languagesale 10% offe-Library read for1 day
This International Standard specifies requirements and tests for cable tray systems and cable ladder systems intended for the support and accommodation of cables and possibly other electrical equipment in electrical and/or communication systems installations. Where necessary, cable tray systems and cable ladder systems may be used for the segregation of cables. This standard does not apply to conduit systems, cable trunking systems and cable ducting systems or any current-carrying parts.
- Standard64 pagesEnglish languagesale 10% offe-Library read for1 day
Specifies requirements and tests for conduit systems, including conduits and conduit fittings, for the protection and management of insulated conductors and/or cables in electrical installations or in communication systems up to 1 000 V a.c. and/or 1 500 V d.c.
- Standard51 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 61386-24:2010
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 62275:2009
- Standard16 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements and tests for slotted cable trunking systems intended for the accommodation, and where necessary for the segregation, of conductors, cables or cords, inside cabinets for electrical and/or communication systems installations up to 1 000 V a.c. and/or 1 500 V d.c.This standard does not apply to conduit, cable tray or cable ladder or current carrying parts within the system. This standard shall be used in conjunction with EN 50085-1:1997, Cable trunking systems and cable ducting systems for electrical installations - Part 1: General requirements, which is referred to in this document as part 1. Wherever reference is made in this standard to EN 50085-1:1997 this does not apply to cable ducting systems
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements and tests for cable trunking systems and cable ducting systems intended for the accommodation, and where necessary for the segregation, of insulated conductors, cables, cords and possibly other electrical equipment in electrical and/or communication systems installations up to 1 000 V a.c. and/or 1 500 V d.c. This standard does not apply to conduit systems, cable tray systems, cable ladder systems, power track systems or equipment covered by other standards. This Part 1 shall be used in conjunction with the relevant Part 2 for particular requirements. NOTE: This Part 1 is not intended to be used by itself.
- Standard27 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 61386-23:2004
- Amendment2 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 61386-21:2004
- Amendment2 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 50085-1:2005
- Amendment2 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 61386-22:2004