IEC/SC 23H - IEC_SC_23H
To prepare standards for industrial plugs, socket-outlets and couplers suitable for use in industrial, commercial, private or public locations, either indoors or outdoors. To prepare standards for other accessories, such as industrial cable reels among others, intended for use with industrial plugs, socket-outlets and couplers. To prepare standards for connection products intended for the connection of electric vehicles to the supply network and/or to dedicated supply equipment. The rated voltages of products covered by these standards lie within IEC 60038
IEC_SC_23H
To prepare standards for industrial plugs, socket-outlets and couplers suitable for use in industrial, commercial, private or public locations, either indoors or outdoors. To prepare standards for other accessories, such as industrial cable reels among others, intended for use with industrial plugs, socket-outlets and couplers. To prepare standards for connection products intended for the connection of electric vehicles to the supply network and/or to dedicated supply equipment. The rated voltages of products covered by these standards lie within IEC 60038
General Information
IEC 60309-5:2017 applies to a single type of plug, socket-outlet, ship connector and ship inlet, hereinafter referred to as accessories, intended to connect ships to dedicated shore supply systems described in IEC/IEEE 80005-3. This part of IEC 60309 applies to three-phase accessories with an earth contact and with four pilot contacts. This publication is to be read in conjunction with IEC 60309-1:2012.
- Standard19 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62196-2:2016 applies to plugs, socket-outlets, vehicle connectors and vehicle inlets with pins and contact-tubes of standardized configurations, herein referred to as accessories. They have a nominal rated operating voltage not exceeding 480 V a.c., 50 Hz to 60 Hz, and a rated current not exceeding 63 A three-phase or 70 A single phase, for use in conductive charging of electric vehicles. This second edition cancels and replaces the first edition published in 2011 and constitutes a technical revision. This second edition includes the following significant technical changes with respect to the previous edition. a) Standard sheets for configurations type 2 and type 3 have been updated. b) Configuration type 2 is now available with optional shutter. This publication is to be read in conjunction with IEC 62196-1:2014.
- Standard64 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62196-3:2014 is applicable to vehicle couplers with pins and contact-tubes of standardized configuration, herein also referred to as "accessories", intended for use in electric vehicle conductive charging systems which incorporate control means, with rated operating voltage up to 1 500 V d.c. and rated current up to 250 A, and 1 000 V a.c. and rated current up to 250 A. This part of IEC 62196 applies to high power d.c. interfaces and combined a.c./d.c. interfaces of vehicle couplers specified in IEC 62196-1:2014, and intended for use in conductive charging systems for circuits specified in IEC 61851-1:2010, and IEC 61851-23:2014. This publication is to be read in conjunction with IEC 62196-1:2011.
- Standard60 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62196-1:2014 is applicable to plugs, socket-outlets, vehicle connectors, vehicle inlets and cable assemblies for electric vehicles, herein referred to as "accessories", intended for use in conductive charging systems which incorporate control means, with a rated operating voltage not exceeding: - 690 V a.c. 50 Hz to 60 Hz, at a rated current not exceeding 250 A; - 1 500 V d.c. at a rated current not exceeding 400 A. This third edition cancels and replaces the second edition published in 2011 and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) addition of a preferred operating voltage of 1 000 V d.c.; b) addition of a preferred rated current of 80 A d.c.; c) addition of a provision for a combined interface a.c./d.c.; d) description of d.c. configurations (previously under consideration); e) addition of requirements pertaining to the locking mechanism, the interlock and the latching device; f) addition of a test for accessories not suitable for making and breaking an electrical circuit under load; g) addition of requirements and tests for insulated end caps.
- Standard91 pagesEnglish languagesale 10% offe-Library read for1 day
Applies to plugs and socket-outlets, cable couplers and appliance couplers, with a rated operating voltage not exceeding 690 V d.c. or a.c. and 500 Hz a.c. and a rated current not exceeding 250 A, primarily intended for industrial use, either indoors or outdoors. The list of preferred ratings is not intended to exclude other ratings, requirements for which are under consideration. This European Standard applies to Series I products only. Series II products are not allowed and not suitable for use in Europe: reference and requirements for Series II products are reported in this standard for information only and shall be ignored. This European Standard applies to products intended to be used with cables with metric sizes (mm2) only. Reference and requirements to AWG and MCM cables are present in the relevant IEC publication and they are reported in this standard for information only. See Annex ZB for a list of references to Series II and/or AWG/MCM cable which are excluded from this standard.
- Amendment15 pagesEnglish languagesale 10% offe-Library read for1 day
2012-03-21: Publication processing allocated to svandriessche@cencenelec.eu
- Amendment5 pagesEnglish languagesale 10% offe-Library read for1 day
Applies to plugs and socket-outlets, cable couplers and appliance couplers with a rated operating voltage not exceeding 690 V, 500 Hz and a rated current not exceeding 125 A, primarily intended for industrial use, either indoors or outdoors. This standard applies to plugs and socket-outlets, cable couplers and appliance couplers with pins and contact tubes of standardized configurations. This standard applies to plugs and socket-outlets, cable couplers and appliance couplers, hereinafter referred to as accessories, for use when the ambient temperature is normally within the range -25 °C to 40 °C. The use of these accessories on building sites and for agricultural, commercial and domestic applications is not precluded. Socket-outlets or appliance inlets incorperated in or fixed to electrical equipment are within the scope of this standard. This standard also applies to accessories intended to be used in extralow voltage installations. This European Standard applies to Series I products only. Series II products are not allowed and not suitable for use in Europe: reference and requirements for. Series II products are reported in this standard for information only and shall be ignored. This European Standard applies to products intended to be used with cables with metric sizes (mm2) only. Reference and requirements to AWG and MCM cables are present in the relevant IEC publication and they are reported in this standard for information only. See Annex ZC for a list of references to Series II and/or AWG/MCM cable which are excluded from this standard.
- Amendment10 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 60309 applies to self-contained products that combine within a single enclosure, a socket-outlet or connector according to IEC 60309-1 or IEC 60309-2 and a switching device, with a rated operating voltage not exceeding 690 V d.c. or a.c. and 500 Hz , and a rated current not exceeding 250 A, primarily intended for industrial use, either indoors or outdoors.
- Standard27 pagesEnglish languagesale 10% offe-Library read for1 day
Merged with prAA:2005 (pr=16884)
- Amendment17 pagesEnglish languagesale 10% offe-Library read for1 day
The contents of the corrigendum of May 2014 have been included in this copy.
- Amendment33 pagesEnglish languagesale 10% offe-Library read for1 day
This standard applies to conversion adaptors intended mainly for industrial use, comprising a housing of insulating material which incorporates an industrial 2P + , 16 A, 6 h 250 V~ type plug part (Table 104 in standard EN 60309-2) and one or two socket-outlets in accordance with the relevant national standards for socketoutlets for household and similar use, with a rated current up to 16 A, intended mainly for industrial use either indoors or outdoors. Adaptors can be used in conjunction with socket-outlets and/or connectors This standard applies to all applications where the ambient temperature does not normally exceed 40 °C. The use of these adaptors on building sites, for agricultural, commercial and domestic applications is not precluded but care should be taken in considering protecting devices in use. Adaptors are for temporary use only. In locations where special conditions prevail, for example on board ship or where explosions are liable to occur, additional requirements may be necessary.
- Standard31 pagesEnglish languagesale 10% offe-Library read for1 day
Applies to cable reels with a rated operating voltage not exceeding 690 V a.c./d.c. and 500 Hz with a rated current not exceeding 63A, primarily intended to industrial use, either indoors or outdoors, for use with accessories complying with EN 60309-1.
- Standard31 pagesEnglish languagesale 10% offe-Library read for1 day
Applies to plugs and socket-outlets, cable couplers with a rated operating voltage not exceeding 690 V, 500 Hz and a rated current not exceeding 125 A. , primarily intented for industrial use , either indoors or outdoors.
- Standard74 pagesEnglish languagesale 10% offe-Library read for1 day
Applies to plugs and socket-outlets, cable couplers and appliance couplers, with a rated operating voltage not exceeding 690 V d.c. or a.c, 500 Hz a.c. and a rated current not exceeding 250 A, primarily intended for industrial use, either indoors or outdoors when the ambient temperature does not normally exceed 40°C.
- Standard81 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60309-2:2021 applies to plugs, fixed or portable socket-outlets, and appliance inlets, hereinafter referred to as accessories, with a rated operating voltage not exceeding 1 000 V DC or 1 000 V AC with a frequency not exceeding 500 Hz and a rated current not exceeding 125 A, primarily intended for industrial use, either indoors or outdoors. This fifth edition cancels and replaces the fourth edition published in 1999, Amendment 1:2005 and Amendment 2:2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: addition of requirements and test for non-solid pins; additional rating IPX9; additional marking to indicate neutral terminal and/or earthing terminal. This document is to be read in conjunction with IEC 60309-1:2021.
- Draft72 pagesEnglish languagesale 10% offe-Library read for1 day
2019-04-01: PM requested FWD assessment. Deadline: 2019-05-05.
- Draft93 pagesEnglish languagesale 10% offe-Library read for1 day
2019-05-27: changed from A1 to new edition further to same change at IEC
- Draft58 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60309-1:2021 applies to plugs, fixed or portable socket-outlets and appliance inlets hereinafter referred to as accessories, with a rated operating voltage not exceeding 1 000 V DC or 1 000 V AC with a frequency not exceeding 500 Hz and a rated current not exceeding 800 A, primarily intended for industrial use, either indoors or outdoors. This fifth edition cancels and replaces the fourth edition published in 1999, Amendment 1:2005 and Amendment 2:2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: addition of classification, requirements and tests for accessories with shutters; additional marking to indicate neutral terminal and/or earthing terminal; replacement of the term "connector" by the term "portable socket-outlet".
- Draft91 pagesEnglish languagesale 10% offe-Library read for1 day
2019-04-01: PM requested FWD assessment. Deadline: 2019-05-05.
- Draft65 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60309-4:2021 applies to self-contained products primarily intended for industrial use, either indoors or outdoors that combine the following items within a single enclosure: – a fixed or portable socket-outlet according to IEC 60309-1 or IEC 60309-2 with a rated operating voltage not exceeding 1 000 V DC or 1 000 V AC with a frequency not exceeding 500 Hz and a rated current not exceeding 800 A; – a switching device. This second edition cancels and replaces the first edition published in 2006 and Amendment 1:2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: – updated in order to take into account the technical revisions to IEC 60309-1 and to IEC 60309-2. This document is to be read in conjunction with IEC 60309-1:2021 and with IEC 60309‑2:2021.
- Draft22 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61316:2021 is available as IEC 61316:2021 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61316:2021 applies to cable reels provided with a non-detachable flexible cable with a rated operating voltage not exceeding 690 V DC and/or 690 V AC with a frequency not exceeding 500 Hz and a rated current not exceeding 63 A, primarily intended for industrial use, either indoors or outdoors, for use with accessories complying with IEC 60309-1, IEC 60309-2 or IEC 60309-4. This third edition cancels and replaces the second edition, published in 1999. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - Implementation of the latest tests and requirements previously included in IEC 60309-1.
- Draft53 pagesEnglish languagesale 10% offe-Library read for1 day
Typing error in the German translation provided by DKE
- Corrigendum1 pageGerman languagesale 10% offe-Library read for1 day
IEC 62196-1:2011 is applicable to plugs, socket-outlets, connectors, inlets and cable assemblies for electric vehicles (EV), herein referred to as 'accessories', intended for use in conductive charging systems which incorporate control means, with a rated operating voltage not exceeding: - 690 V a.c. 50 Hz - 60 Hz, at a rated current not exceeding 250 A, - 1 500 V d.c. at a rated current not exceeding 400 A. This second edition cancels and replaces the first edition published in 2003 and constitutes a technical revision. The main changes from the previous edition are as follows: - increase in d.c.voltage for accessories; - permitted use of accessories with vehicles complying with Subclause 7.2.3.1 of 61851-1:2010; - minor changes to definitions; - additional voltage and current ratings (Clause 5) and test values (Clause 12, 13,); - removal of markings to identify generic types of vehicle inlets and connectors; - addition of a 'high power d.c.' to the type of accessories covered by the Standard; - modification of the description of 'universal' and 'basic' interfaces based on changes to 61851-1:2010; - simplification of the marking requirements (Clause 8); - additional requirements for accessories with shutters; - division of Clause 9 to create Clauses 9 and 11; - Clause 9: specific requirements for inlet, plug and socket-outlet; - Clause 11: EVSE (Electric Vehicle Supply Equipment) requirements: the basic generic requirements for charging stations; - renumbering of annexes.
- Standard80 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62196-2:2011 applies to plugs, socket-outlets, vehicle connectors and vehicle inlets with pins and contact-tubes of standardized configurations, herein referred to as accessories. They have a nominal rated operating voltage not exceeding 500 V a.c., 50 to 60 Hz, and a rated current not exceeding 63 A three-phase or 70 A single phase, for use in conductive charging of electric vehicles. This standard covers the basic interface accessories for vehicle supply as specified in IEC 62196-1, and intended for use in conductive charging systems for circuits specified in IEC 61851-1:2010. This publication is to be read in conjunction with IEC 62196-1:2011.
- Standard62 pagesEnglish languagesale 10% offe-Library read for1 day
D124/111: To be dealt with by BTWG 112-1 * Superseded by EN 60309-1:1999/A1:2007
- Amendment2 pagesEnglish languagesale 10% offe-Library read for1 day
D124/111: To be dealt with by BTWG 112-1 * Superseded by EN 60309-2:1999/A1:2007
- Amendment3 pagesEnglish languagesale 10% offe-Library read for1 day
This part of EN 62196 is applicable to plugs, socket-outlets, connectors, inlets and cable assemblies for electric vehicles, intended for use in conductive charging systems which incorporate control means, with a rated operating voltage not exceeding: 690 V a.c., 50 - 60 Hz, at a rated current not exceeding 250 A; 600 V d.c., at a rated current not exceeding 400 A.
- Standard75 pagesEnglish languagesale 10% offe-Library read for1 day
This standard applies to plugs and socket-outlets, cable couplers and appliance couplers with a rated operating voltage not exceeding 690 V, 500 Hz and a rated current not exceeding 125 A, primarily intended for industrial use, either indoors or outdoors. This standard applies to plug and socket-outlets, cable couplers and appliance couplers with pins and contact tubes of standardized configurations. This standard applies to plugs and socket-oulets, cable couplers and appliance couplers, herinafter referred to as accessories, for use when the ambient temperature is normally within the range -25 °C to 40 °C. The use of these accessories on building sites and for agricultural, commercial and domestic applications is not precluded. Socket-outlets or appliance inlets incorporated in or fixed to electrical equipment are within the scope of this standard. This standard also applies to accessories intended to be used in extra-low voltage installations.
- Standard71 pagesEnglish languagesale 10% offe-Library read for1 day
This standard applies to plugs and socket-outlets, cable couplers and appliance couplers, with a rated voltage not exceeding 690 V d.c. or a.c. and 500 Hz a.c. and a rated current not exceeding 250 A, primarily intended for industrial use, either indoors or outdoors. The list of preferred ratings is not intended to exclude other ratings, requirements for which are under consideration. This standard applies to plugs and socket-outlets, cable couplers and appliance couplers, hereinafter referred to as accessories, for use when the ambient temperature is normally within the range of -25 °C to +40 °C. These accessories are intended to be connected to cables of copper or copper alloy only. The use of these accessories on building sites and for agricultural, commercial and domestic applications is not precluded. Socket-outlets or appliance inlets incorporated in or fixed to electrical equipment are within the scope of this standard. This standard also applies to accessories to be used in extra-low voltage installations. This standard does not apply to accessories primarily intended for domestic and similar general purposes. In locations where special conditions prevail, for example on board ship or where explosions are liable to occur, additional requirements may be necessary.
- Standard78 pagesEnglish languagesale 10% offe-Library read for1 day
This standard applies to plugs and socket-outlets, cable couplers and appliance couplers, with a rated operating voltage not exceeding 690 V d.c. or a.c. and 500 Hz a.c. and a rated current not exceeding 250 A, primarily intended for industrial use, either indoors or outdoors. The list of preferred ratings is not intended to exclude other ratings, requirements for which are under consideration. This standard applies to plugs and socket-outlets, cable couplers and appliance couplers, hereinafter referred to as accessories, for use when the ambient temperature does not normally exceed 40 C. The use of these accessories on building sites and for agricultural, commercial and domestic applications is not precluded. Socket-outlets or appliance inlets incorporated in or fixed to electrical equipment are within the scope of this standard. This standard also applies to accessories intended to be used in extra-low voltage installations. This standard does not apply to accessories primarily intended for domestic and similar general purposes. In locations where special conditions prevail, for example on board ship or where explosions are liable to occur, additional requirements may be necessary.
- Standard66 pagesEnglish languagesale 10% offe-Library read for1 day