IEC 60092-352:2025 provides the basic requirements for the selection, installation and operating conditions of electrical cables intended for fixed electrical systems on board ships at voltages (U) up to and including Um 18/30 (36) kV, symmetrical category cables and fibre optic cables.
The reference to fixed systems includes those that are subjected to vibration (due to the movement of the ship) or movement (due to motion of the ship) and not to those that are intended for frequent flexing.
Cables subject to frequent or continual flexing use, which can withstand the mechanical stress and the environment they are exposed to, are detailed in other IEC specifications such as IEC 60227 and IEC 60245. Flexible cables are frequently used for retractable thrusters, elevators, moving decks, cranes, shore connections and other moving applications on board ships.
This fourth edition cancels and replaces the third edition published in 2005. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) modification of the part title;
b) complete review of the document and establishment of the match with all other standards from the group IEC 60092-350 to IEC 60092-379;
c) addition of terms and definitions;
d) addition of technical requirements for the installation of symmetrical category cables with transmission characteristics up to 1 000 MHz;
e) addition of the technical requirements for the installation of fibre optic cables;
f) addition of technical requirements for the installation of cables for installation between areas with and without explosive atmospheres

  • Standard
    115 pages
    English language
    sale 15% off

HD 626 applies to cables of rated voltage U0/U(Um) = 0,6/1(1,2) kV used in overhead power distribution systems mainly for public distribution, of maximum system voltage not exceeding 1,2 kV. This part (Part 1) specifies the general requirements applicable to these cables, unless otherwise specified in the particular sections of this HD.
The objects of this Harmonisation Document are:
- to standardize cables that are safe and reliable when properly used and equipped with appropriate accessories, in relation to the technical requirements of the system of which they form a part,
- to state the characteristics and manufacturing requirements which have a direct or indirect bearing on safety,
- and to specify methods for checking conformity with those requirements.

  • Standardization document
    377 pages
    English language
    sale 10% off
    e-Library read for
    1 day

HD 626 applies to cables of rated voltage U0/U(Um) = 0,6/1(1,2) kV used in overhead power distribution systems mainly for public distribution, of maximum system voltage not exceeding 1,2 kV. This part (Part 1) specifies the general requirements applicable to these cables, unless otherwise specified in the particular sections of this HD. The objects of this Harmonisation Document are: - to standardize cables that are safe and reliable when properly used and equipped with appropriate accessories, in relation to the technical requirements of the system of which they form a part, - to state the characteristics and manufacturing requirements which have a direct or indirect bearing on safety, - and to specify methods for checking conformity with those requirements.

  • Standardization document
    377 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of UV laser printable coaxial cables, 50 Ω, type WZ, for use in aircraft electrical systems at operating temperatures between −65 °C and 200 °C and specially for high frequency up to 6 GHz.
The document encloses also a reinforced cable version (code R) which is used for sensitive systems with controlled VSWR.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of post installation flexible self-wrapping fire protection sleeves for electrical cable and cable bundles, providing 360° fire protection to electrical harnesses. The sleeve assembly gives fire resistance protection to the internal electrical harness against fire for five minutes and ensures that the electrical characteristics of cables will not be degraded.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the list of product standards and common characteristics of electrical cables for use in the on-board electrical systems of aircraft at operating temperatures between -55 °C and 260 °C (except otherwise specified in product standards).

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of UV laser printable DR family, single and multicore screened (spiral) and jacketed electrical lightweight cables for use in the on-board electrical systems of aircraft, at operating temperatures between −55 °C and 260 °C. Nevertheless, if needed, −65 °C is also acceptable as shown by cold test.
It is also possible to mark these cables by qualified compatible marking.
These markings are compliant with EN 3838.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a method of evaluating the performance of a cable after exposure to a thermal shock.
It is intended to be used together with EN 3475-100.

  • Standard
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC TS 63263:2025 describes a test method for evaluating the lifetime of winding wires under electrical high frequency voltage impulses (with partial discharges) at elevated temperatures. This method is only applicable as a comparative examination under a given sample preparation and testing environment. The comparative nature of this document lies in the fact that the lifetime under partial discharges depends on a large number of influencing factors in the sample preparation and test conditions which could not all be thoroughly investigated so far.
This document applies to round and rectangular magnet wires.

  • Technical specification
    12 pages
    English language
    sale 15% off

IEC TR 63162:2025, which is a Technical Specification, provides failure rates at reference conditions for electric components, considering reference conditions defined in IEC 61709.
Reference conditions are useful since they provide a known standard basis from which failure rates can be modified to account for differences in environment from the environments taken as reference conditions.
To perform reliability prediction, which is described in IEC 61709:2017, Annex C, failure rates, together with assumptions and limitations, are used.
IEC 61709 does not provide failure rates for components, but only provides models that allow failure rates obtained by other means to be converted from one operating condition to another operating condition.
This document provides generic failure rates considering those contained in the list of selected sources, calculated at reference conditions, as defined in IEC 61709. In fact, although models are different, calculated values at reference conditions do not appear to be so different, hence allowing a consistent converging process. See also IEC 61709:2017, 4.6.
Each user can easily calculate failure rates at any condition using IEC 61709.

  • Technical report
    33 pages
    English language
    sale 15% off

IEC 60332‑1‑2:2025 specifies the procedure for testing the resistance to vertical flame propagation for a single vertical electrical insulated conductor or cable, or optical fibre cable, under fire conditions using a 1 kW pre-mixed flame. The apparatus is described in IEC 60332‑1‑1.
NOTE 1 Testing to IEC 60332‑1‑2 can be performed simultaneously with that to IEC 60332‑1‑3, if required.
This group safety publication focusing on test method(s) is primarily intended to be used as a product safety standard for the products mentioned in the scope, but is also intended to be used by technical committees in the preparation of standards for products similar to those mentioned in the scope of this group safety publication, in accordance with the principles laid down in IEC Guide 104 and lSO/lEC Guide 51.
NOTE 2 The performing of this test method on a single insulated conductor or cable or optical fibre cable does not provide compliance with fire propagation requirements in relevant standards in the case that the single insulated conductor or cable or optical fibre cable is installed with or amongst other cables as a group. (See the IEC 60332‑3 series).
One of the responsibilities of a technical committee is, wherever applicable, to make use of basic safety publications and/or group safety publications in the preparation of its publications.

  • Standard
    12 pages
    English language
    sale 15% off

This document specifies the test methods to evaluate the performance of coaxial, quadrax and databus cables after the installation of plastic cable ties.
It is expected to be used together with EN 3475 100.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the dimensions, tolerances, required characteristics and the mass of an AWG 24 shielded quad cable, type KL, intended for high speed (100 Mbit/s) full duplex Ethernet networks.
Linked to this particular application, the operating temperatures of the cable are between −65 °C and 125 °C.
This cable is laser markable, this marking satisfies the requirements of EN 3838.
The characteristics impedance is 100 Ω ± 15 Ω.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies test methods for cable management systems (CMS) intended to provide support for intrinsic fire-resistant cables in order to determine their abilities to maintain the function of electrical power cables and signal/control cables for a specified duration when subjected to fire under defined conditions.
This document establishes a non-hierarchical classification for this ability.
Additional devices to fix the cable management systems providing fire resistant support (CMS-support) to the building structure for example screws, anchors etc. are not covered by this document.
CMS intended to provide support and fire protection for cables are tested according to EN 1366-11.
This document does not apply to powertrack systems.
NOTE   Rules for testing CMS-support for fibre optic cables according to EN 50582 and communication cables according to EN 50289-4-16 are under consideration.

  • Technical specification
    53 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies test methods for cable management systems (CMS) intended to provide support for intrinsic fire-resistant cables in order to determine their abilities to maintain the function of electrical power cables and signal/control cables for a specified duration when subjected to fire under defined conditions. This document establishes a non-hierarchical classification for this ability. Additional devices to fix the cable management systems providing fire resistant support (CMS-support) to the building structure for example screws, anchors etc. are not covered by this document. CMS intended to provide support and fire protection for cables are tested according to EN 1366-11. This document does not apply to powertrack systems. NOTE Rules for testing CMS-support for fibre optic cables according to EN 50582 and communication cables according to EN 50289-4-16 are under consideration.

  • Technical specification
    53 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of UV laser printable DR family, 1 to 11 cores, taped, screened (braided) and jacketed electrical lightweight cables for use in the on-board electrical systems of aircraft, at operating temperatures between −55 °C and 260 °C. Nevertheless, if needed, −65 °C is also acceptable as shown by cold test.
It is possible to mark these cables by qualified compatible marking, in line with EN 3838.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the list of product standards and common characteristics of electrical cables for general purpose with conductors in aluminium or copper-clad aluminium, intended for installation in aircraft electrical systems.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61442:2023 is available as IEC 61442:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61442:2023 specifies the test methods applicable for type testing accessories for power cables with rated voltages from 3,6/6 (7,2) kV up to 18/30 (36) kV. The test methods specified in this document apply to accessories for extruded and paper insulated cables according to IEC 60502-2 and IEC 60055-1 respectively.

  • Standard
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a method to measure the ability of a protective sleeve to withstand specified severities of simulated lightning strikes.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of UV laser printable electrical lightweight wires ADA family for use in the on-board 115 V (phase to neutral) or 200 V (phase-to-phase) AC, 28 VDC electrical systems of aircraft at operating temperatures between −65 °C and 180 °C. These cables are demonstrated to be arc resistant in sizes AWG 26 to 14 (115 VAC/200 VAC).
In addition, these cables can be suitable for use at 230 VAC/400 VAC in pressurized zones only when installed to take account of possible short circuit effects.
Other electrical system configurations are the responsibility of the users.
It is also possible to mark these cables by qualified compatible marking which satisfies the requirements of EN 3838:2022.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of UV laser printable electrical lightweight wires AD family for use in the on-board 115 V (phase to neutral) or 200 V (phase to phase) AC, 28 VDC electrical systems of aircraft at operating temperatures between −65 °C and 180 °C. These cables are demonstrated to be arc resistant in sizes AWG 24 to 14 (115 VDC/200 VDC).
In addition, these cables can be suitable for use at 230 VAC/400 VAC in pressurized zones only when installed to take account of possible short circuit effects.
Other electrical system configurations are the responsibility of the users.
It is also possible to mark these cables by qualified compatible marking which satisfies the requirements of EN 3838:2022.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the test methods to evaluate the wicking of wire and cable insulated with textile braid.
It is intended to be used together with EN 3475-100.

  • Standard
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60851-1:2021 specifies the general notes on methods of test for winding wires. It also gives the definitions for terms used in IEC 60851 (all parts). A survey of the contents of IEC 60851-2 to IEC 60851-6 is given in Annex A. This third edition cancels and replaces the second edition published in 1996, and its amendment 1:2003 and amendment 2:2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- revision to Clause 2 to update the list of normative references;
- revision to 3.2 atmospheric conditions for testing;
- addition to 3.2 with remarks concerning frequency and management of tests;
- revision to Annex A to update the contents list of IEC 60851 series of tests.

  • Standard
    25 pages
    English language
    sale 15% off
  • Standard
    29 pages
    English and French language
    sale 15% off

IEC 60851-1: 2024 Amendment 1

  • Standard
    6 pages
    English and French language
    sale 15% off

This document specifies the characteristics of post installation flexible mechanical protection sleeves for electrical cable and cable bundles made from meta-aramid fibres and provided with a water repellent protection.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies methods for measuring and calculating the coverage of protection sleeves for electrical cables and cable bundles. It is presupposed to be used together with EN 6059 100.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61442:2023 is available as IEC 61442:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61442:2023 specifies the test methods applicable for type testing accessories for power cables with rated voltages from 3,6/6 (7,2) kV up to 18/30 (36) kV. The test methods specified in this document apply to accessories for extruded and paper insulated cables according to IEC 60502-2 and IEC 60055-1 respectively.

  • Standard
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60331-4:2024 specifies the test apparatus and procedure, and gives the performance requirements, including recommended flame application times and flame temperatures, for power cables of rated voltage higher than 0,6/1,0 kV up to and including 18/30 kV for maintaining circuit integrity when subject to fire and mechanical shock under specified conditions.
The test method in this document is restricted to conductor sizes up to and including 120 mm2. The test results for 120 mm2 size conductors constructions qualify larger cross-sections of the same cable construction.
In the case of preassembled three-core cables, then the complete cable is considered as tested when a complete single-core of the cable has been tested.
This document includes details for the specific point of failure, continuity checking arrangement, test sample, test procedure and test report relevant to electric power cables with a rated voltage higher than 0,6/1,0 kV up to and including 18/30 kV.
Annex A provides the method of verification of the burner and control system used for the test.
Annex B provides a choice of the recommended test apparatus.
Annex C provides, as an option, guidance for using either water spray or water jet protocols.
Annex D provides, as an option, the flame temperature of 1 000 °C, which is applicable for special applications.
Requirements are stated for an identification that can optionally be marked on the cable to signify compliance with this document.
This group safety publication focusing on the test method for circuit integrity safety for power cables of rated voltage higher than 1 kV up to and including 30 kV under fire conditions, is primarily intended to be used as a product safety standard for the products mentioned in the scope, but is also intended to be used by TCs in the preparation of publications for products similar to those mentioned in the scope of this group safety publication, in accordance with the principles laid down in IEC Guide 104 and lSO/lEC Guide 51.
One of the responsibilities of a TC is, wherever applicable, to make use of either BSPs or GSPs, or both, in the preparation of its publications.
WARNING – The test given in this document can involve the use of dangerous voltages and temperatures. Suitable precautions should be taken against the risk of shock, burning, fire and explosion that can arise, and against any noxious fumes that can be produced.

  • Standard
    29 pages
    English language
    sale 15% off

IEC 61400-24:2019 applies to lightning protection of wind turbine generators and wind power systems. Refer to guidelines for small wind turbines in annex.
This document defines the lightning environment for wind turbines and risk assessment for wind turbines in that environment. It defines requirements for protection of blades, other structural components and electrical and control systems against both direct and indirect effects of lightning. Test methods to validate compliance are included.
Guidance on the use of applicable lightning protection, industrial electrical and EMC standards including earthing is provided.
This second edition cancels and replaces the first edition, published in 2010. This edition includes the following significant technical changes with respect to the previous edition:
a) it is restructured with a main normative part, while informative information is placed in annexes.

  • Standard
    191 pages
    English language
    sale 15% off
  • Standard
    404 pages
    English language
    sale 15% off
  • Standard
    405 pages
    English and French language
    sale 15% off

IEC 60092-378:2024 is applicable to shipboard and offshore optical fibre cables, intended for fixed installations.
Cables designed to maintain functional integrity during fire given in 6.1 and to be installed in explosive atmospheres given in 6.2 are included.
The various types of optical fibre cables are given in Clause 6. The constructional requirements and test methods are aligned with those indicated in IEC 60092‑350, unless otherwise specified in this document.

  • Standard
    19 pages
    English language
    sale 15% off

IEC 60317-0-3:2024 is available as IEC 60317-0-3:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

IEC 60317-0-3:2024 specifies the general requirements of enamelled round aluminium winding wires with or without a bonding layer. The range of nominal conductor diameters is given in the relevant specification sheet.
This edition includes the following significant technical changes with respect to the previous edition:
a) Revision to Clause 7, designating the test as inappropriate;
b) Revision to Clause 10, designating the test as inappropriate.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60317-0-3:2024 is available as IEC 60317-0-3:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60317-0-3:2024 specifies the general requirements of enamelled round aluminium winding wires with or without a bonding layer. The range of nominal conductor diameters is given in the relevant specification sheet. This edition includes the following significant technical changes with respect to the previous edition: a) Revision to Clause 7, designating the test as inappropriate; b) Revision to Clause 10, designating the test as inappropriate.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61340-6-1:2018 applies to facilities that provide healthcare including hospitals, care centres and clinics. This document provides technical requirements and recommendations for controlling electrostatic phenomena in healthcare facilities, which includes requirements for equipment, materials, and products used to control static electricity. The requirements of this document do not apply to medical electrical equipment specified in IEC 60601-1 and in vitro diagnostic (IVD) medical equipment specified in IEC 61010‑2‑101.

  • Standard
    46 pages
    English language
    sale 15% off
  • Standard
    45 pages
    English and French language
    sale 15% off

IEC 60317-27-1:2020 specifies the requirements of paper tape covered round copper winding wires. This covering consists of two or more layers of paper tape and is primarily intended for winding coils for oil immersed transformers. The range of nominal conductor diameters covered by this document is:
– 0,500 mm up to and including 5,000 mm.
The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1:2013.
The paper tapes included in this document are restricted to those specified in IEC 60554-1 and IEC 60554-3-5.

  • Standard
    22 pages
    English language
    sale 15% off
  • Standard
    21 pages
    English and French language
    sale 15% off

This standard specifies design, dimensions and test requirements for halogen-free cables with extruded insulation and sheath having a voltage rating of up to and including 450/750 V for flexible applications under severe condition for the power supply between the electricity supply point or the charging station and the electric vehicle (EV).
The EV charging cable is intended to supply power and if needed communication (details see EN 61851 1 and the EN 62196 series) to an electric vehicle. The charging cables are applicable for charging modes 1-3 of EN 61851 1. The cables in this standard with rated voltage 300/500 V are only permitted for charging mode 1 of EN 61851 1.
The maximum conductor operating temperatures for the cables in this standard is 90 °C.
The cables may be:
a)   an integral part of the vehicle (case A of EN 61851 1); or
b)   a detachable cable assembly with a vehicle connector and AC supply connection to a socket outlet (case B of EN 61851 1); or
c)   permanently attached to a fixed charging point (case C of EN 61851 1).
This standard describes cables whose safety and reliability is ensured when they are installed and/or used in accordance to the guide to use EN 50565 1 and Annex B

  • Amendment
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies design, dimensions and test requirements for halogen-free cables with extruded insulation and sheath having a voltage rating of up to and including 450/750 V for flexible applications under severe condition for the power supply between the electricity supply point or the charging station and the electric vehicle (EV). The EV charging cable is intended to supply power and if needed communication (details see EN 61851 1 and the EN 62196 series) to an electric vehicle. The charging cables are applicable for charging modes 1-3 of EN 61851 1. The cables in this standard with rated voltage 300/500 V are only permitted for charging mode 1 of EN 61851 1. The maximum conductor operating temperatures for the cables in this standard is 90 °C. The cables may be: a) an integral part of the vehicle (case A of EN 61851 1); or b) a detachable cable assembly with a vehicle connector and AC supply connection to a socket outlet (case B of EN 61851 1); or c) permanently attached to a fixed charging point (case C of EN 61851 1). This standard describes cables whose safety and reliability is ensured when they are installed and/or used in accordance to the guide to use EN 50565 1 and Annex B

  • Amendment
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part 2-2 of the EN IEC 61084 series specifies particular requirements and tests for cable trunking systems (CTS) and cable ducting systems (CDS) intended for mounting underfloor, flushfloor or onfloor.

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part 2-3 of the EN IEC 61084 series specifies particular requirements and tests slotted cable
trunking systems intended for mounting inside cabinets in electrical and/or communication system installations.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Common modifications for the adoption as a European Standard of IEC 61084-2-3:2017 ed 1.0 (PR=72102)

  • Amendment
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Common modifications for the adoption as a European Standard of IEC 61084-2-4:2017 ed 2.0 (PR=72103)

  • Amendment
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Common modifications for the adoption as a European Standard of IEC 61084-1:2017 ed 2.0 (PR= 69866).

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day