IEC 61083-1:2021 is applicable to digital recorders, including digital oscilloscopes, used for measurements during tests with high impulse voltages and high impulse currents. It specifies the measuring characteristics and calibrations required to meet the measuring uncertainties and procedures specified in IEC 60060-2 and IEC 62475.
This document
• defines the terms specifically related to digital recorders;
• specifies the necessary requirements for such instruments to ensure their compliance with the requirements for high-voltage and high-current impulse tests;
• establishes the tests and procedures necessary to demonstrate their compliance;
• covers digital recorders that permit access to raw data from permanent or temporary storage;
• covers peak meters used for measuring the extreme value of lightning impulses, the peak value of switching or current impulses.
It has the status of a horizontal standard in accordance with IEC Guide 108.
This horizontal standard is primarily intended for use by technical committees in the preparation of standards in accordance with the principles laid down in IEC Guide 108. One of the responsibilities of a technical committee is, wherever applicable, to make use of horizontal standards in the preparation of its publications. The contents of this horizontal standard will not apply unless specifically referred to or included in the relevant publications.
This third edition cancels and replaces the second edition published in 2001. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) Requirements for static integral non-linearity and static differential non-linearity have been removed.
b) Requirement for impulse scale factor non-linearity has been added.
c) Uncertainty requirements for impulse calibrators have been revised.
d) Requirements for peak voltmeter have been revised.

  • Standard
    50 pages
    English and French language
    sale 15% off

IEC 60433:2021 is applicable to string insulator units of the long rod type with insulating parts of ceramic material intended for use in AC overhead power lines with a nominal voltage greater than 1000 V and a frequency not greater than 100 Hz. It is also applicable to insulators of similar design, used in substations. This document is applicable to ceramic string insulator units of the long rod type, either with a clevis end fitting at both ends for coupling with a tongue, or with a socket end fitting at both ends for coupling with a pin ball. The object of this document is to prescribe specified values for electrical and mechanical characteristics, and for the principal dimensions of ceramic string insulator units of the long rod type. This fourth edition cancels and replaces the third edition published in 1998. This edition includes the following significant technical changes with respect to the previous edition:
- wording in Scope changed from "should" to "are intended to";
- new normative references added;
- title of Clause 4 amended, new Note 4 added;
- Table 1 expanded to include more specified mechanical failing loads.

  • Standard
    21 pages
    English and French language
    sale 15% off

IEC 60305:2021 applies to string insulator units of the cap and pin type with insulating parts of ceramic material or glass, intended for AC overhead lines with a nominal voltage greater than 1 000 V and a frequency not greater than 100 Hz. It also applies to insulators of similar design used in substations. This document applies to string insulator units of the cap and pin type either with ball and socket couplings or with clevis and tongue couplings. This document applies to string insulator units for use on overhead lines in clean areas and polluted areas. For use in areas characterized by very heavy pollution levels and for other particular or extreme environmental conditions, it may be necessary for certain dimensions to be changed and insulator units having different creepage distances, spacing and forms may be preferred (for example, flat profile, hemispherical etc.). Insulators for use on DC systems may also need different dimensions. In any case, it is applicable that the standardized mechanical characteristics of this document and coupling sizes are retained. This fifth edition cancels and replaces the fourth edition published in 1995. This edition includes the following significant technical changes with respect to the previous edition:
- wording in Scope changed from "it is recommended" to "it is applicable";
- new normative references added;
- electromechanical or mechanical failing load in Clause 4 specified;
- new figures added showing profiles.

  • Standard
    28 pages
    English and French language
    sale 15% off

This international standard applies to string insulator units of the cap and pin type and also of
the long rod type as well as the fittings used with such insulators.
The object of this document is to define the dimensions of a series of clevis and tongue
couplings to permit the assembly of insulators or fittings supplied by different manufacturers.
NOTE 1 IEC 60305 gives the coordination between the standardized dimensions of Table 1 and the strength
classes of cap and pin insulator. IEC 60433 gives the coordination between the standardized dimensions of Table 2
and the strength classes of long rod insulators.
NOTE 2 If the dimensions given in Table 1 are not sufficient, higher strength classes are given in IEC 60305.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This international standard is applicable to locking devices used with ball and socket
couplings of string insulator units and used with the corresponding metal fittings standardized
in IEC 60120, when they are supplied separately.
When these locking devices are supplied with an insulator or fitting, they are considered as an
integral part of it. In this case, the relevant test is to be included with those of insulators, as
specified in IEC 60383-1 and IEC 61325. On request, a certificate is to be delivered
confirming that the tests on locking devices as specified in this document have been carried
out. The locking devices are usually supplied with the insulator or corresponding metal fittings.
The object of this document is
• to define the shapes and some standard dimensions for locking devices,
• to define the test methods for locking devices,
• to state the acceptance conditions for supply,
• to give other dimensions for guidance of manufacturing only.
The object of this document does not include the specification of the nature of the material,
and the material covered by the scope of this document does not have a surface coating for
corrosion protection. However, the material which will give rise to significant contact
corrosion(chemical reaction) between the locking device and the ball and socket coupling
does not covered by this document.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The object of this international standard is to define the dimensions of a series of standard
ball and socket couplings using the standard locking devices (see IEC 60372) in order to
permit the assembly of insulators or metal fittings supplied by different manufacturers.
This document applies to string insulator units of the cap and pin and long rod types and their
associated metal fittings.
For the pin ball and the socket, dimensions apply to the finished product after any surface
treatment.
Extreme positions of the pin ball in the socket are given in Annex A.
Typical examples of gauges for checking the dimensions of pin balls and sockets are given in
Annex B.
NOTE Only the dimensions necessary for assembly are dealt with in this standard. Properties of material and
working loads are not specified. The co-ordination of dimensions with strength classes is specified in IEC 60305
and IEC 60433.

  • Standard
    40 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60120:2020 define the dimensions of a series of standard ball and socket couplings using the standard locking devices (see IEC 60372) in order to permit the assembly of insulators or metal fittings supplied by different manufacturers. This document applies to string insulator units of the cap and pin and long rod types and their associated metal fittings. For the pin ball and the socket, dimensions apply to the finished product after any surface treatment. Extreme positions of the pin ball in the socket are given in annex. Typical examples of gauges for checking the dimensions of pin balls and sockets are given in annex.

  • Standard
    74 pages
    English and French language
    sale 15% off

IEC 60372:2020 is applicable to locking devices used with ball and socket couplings of string insulator units and used with the corresponding metal fittings standardized in IEC 60120, when they are supplied separately.The object of this document is
- to define the shapes and some standard dimensions for locking devices,
- to define the test methods for locking devices,
- to state the acceptance conditions for supply,
- to give other dimensions for guidance of manufacturing only.
This fourth edition cancels and replaces the third edition published in 1984. This edition includes the following significant technical changes with respect to the previous edition:
a. Two new designated size of couplings, 36 and 40, were introduced;
b. the relevant content of the 28B W-clip was deleted;
c. Annex A is informative, Annex B is normative, Annex C is informative.

  • Standard
    37 pages
    English and French language
    sale 15% off

IEC 60471:2020 applies to string insulator units of the cap and pin type and also of the long rod type as well as the fittings used with such insulators. The object of this document is to define the dimensions of a series of clevis and tongue couplings to permit the assembly of insulators or fittings supplied by different manufacturers.
This third edition cancels and replaces the second edition published in 1977. This edition includes the following significant technical changes with respect to the previous edition:
- there are no new clevis and tongue couplings;
- For the dimensions of the existing designated size of couplings that characterize the same location, the effective number of the size is unified.

  • Standard
    20 pages
    English and French language
    sale 15% off

This document is applicable to composite line post insulators for AC overhead lines with a nominal voltage greater than 1 000 V and a frequency not greater than 100 Hz. It also applies to line post insulators of similar design used in substations or on electric traction lines. This document applies to line post insulators of composite type, generally with metallic couplings, with and without a base plate. It also applies to such insulators when used in complex structures. It does not apply to hollow insulators adapted for use as line post insulators. The object of this document is to specify the main dimensions of the couplings to be used on the composite line post insulators in order to permit the assembly of insulators or fittings supplied by different manufacturers and to allow, whenever practical, interchangeability with existing installations. It also specifies a standard designation system for composite line post insulators.

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61952 is applicable to composite line post insulators for AC overhead lines with a nominal voltage greater than 1 000 V and a frequency not greater than 100 Hz. It also applies to line post insulators of similar design used in substations or on electric traction lines. This document applies to line post insulators of composite type, generally with metallic couplings, with and without a base plate. It also applies to such insulators when used in complex structures. It does not apply to hollow insulators adapted for use as line post insulators. The object of this document is to specify the main dimensions of the couplings to be used on the composite line post insulators in order to permit the assembly of insulators or fittings supplied by different manufacturers and to allow, whenever practical, interchangeability with existing installations. It also specifies a standard designation system for composite line post insulators.

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61952-1:2019 is applicable to composite line post insulators for AC overhead lines with a nominal voltage greater than 1 000 V and a frequency not greater than 100 Hz. It also applies to line post insulators of similar design used in substations or on electric traction lines.
This document applies to line post insulators of composite type, generally with metallic couplings, with and without a base plate. It also applies to such insulators when used in complex structures. It does not apply to hollow insulators adapted for use as line post insulators
The object of this document is to specify the main dimensions of the couplings to be used on the composite line post insulators in order to permit the assembly of insulators or fittings supplied by different manufacturers and to allow, whenever practical, interchangeability with existing installations. It also specifies a standard designation system for composite line post insulators.

  • Standard
    64 pages
    English and French language
    sale 15% off

IEC - Corrected version

  • Corrigendum
    3 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Corrigendum
    3 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC - Corrected version

  • Corrigendum
    3 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Corrigendum
    3 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60404-16:2018 is applicable to Fe-based amorphous strips specified in IEC 60404-8-11 for the measurement of AC magnetic properties at frequencies up to 400 Hz.
The object of this part is to define the general principles and technical details of the measurement of the magnetic properties of Fe-based amorphous strips by means of a single sheet tester.
The contents of the corrigendum of November 2018 have been included in this copy.

  • Standard
    53 pages
    English and French language
    sale 15% off

IEC 62688:2017 describes the fundamental construction and testing requirements for Concentrator Photovoltaic (CPV) modules and assemblies in order to provide safe electrical and mechanical operation during their expected lifetime. Specific topics are provided to assess the prevention of electrical shock, fire hazards, and personal injury due to mechanical and environmental stresses. This document attempts to define the basic requirements for various application classes of concentrator photovoltaic modules and assemblies, but does not encompass all national and regional codes. This document is designed so that its test sequence can coordinate with those of IEC 62108, so that a single set of samples may be used to perform both the safety and performance evaluation of a CPV module and assembly.

  • Standard
    158 pages
    English and French language
    sale 15% off

In some cases, it has been necessary to include in an IEV part a concept taken from another
IEV part, or from another authoritative terminology document (VIM, ISO/IEC 2382, etc.), in
both cases with or without modification to the definition (and possibly to the term).
This is indicated by the mention of this source, printed in lightface, and placed between
square brackets at the end of the definition.
Example: [131-03-13 MOD]
(MOD indicates that the definition has been modified)
Terms in additional IEV languages
These terms are placed at the end of the entry, on separate lines (one single line for each
language), preceded by the alpha-2 code for the language defined in ISO 639, and in the
alphabetic order of this code. Synonyms are separated by semicolons.

  • Standard
    58 pages
    English and French language
    sale 15% off
  • Standard
    58 pages
    English and French language
    sale 10% off
    e-Library read for
    1 day

This International Standard applies to composite hollow core station post insulators consisting
of a load-bearing insulating tube (core) made of resin impregnated fibres an insulating filler
material (e.g. solid, liquid, foam, gaseous – pressurized or unpressurized), a housing (outside
the insulating tube) made of polymeric material (for example silicone or ethylene-propylene)
and metal fixing devices at the ends of the insulating tube. Composite hollow core station post
insulators as defined in this standard are intended for general use in substations in both,
outdoor and indoor environments, operating with a rated AC voltage greater than 1 000 V and
a frequency not greater than 100 Hz or for use in direct current systems with a rated voltage
greater than 1 500 V.
The object of this standard is:
– to define the terms used;
– to prescribe test methods;
– to prescribe acceptance criteria.
All the tests in this standard, apart from the thermal-mechanical test, are performed at normal
ambient temperature. This standard does not prescribe tests that may be characteristic of the
apparatus of which the composite hollow core station post insulator ultimately may form a
part. Further technical input is required in this area.
NOTE 1 "Pressurized" means a permanent gas or liquid pressure greater than 0,05 MPa (0,5 bar) gauge. The gas
can be dry air or inert gases, for example sulphur hexafluoride, nitrogen, or a mixture of such gases.
NOTE 2 "Unpressurized" means a gas or liquid pressure smaller than or equal to 0,05 MPa (0,5 bar) gauge.

  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62772:2016 applies to composite hollow core station post insulators consisting of a load-bearing insulating tube (core) made of resin impregnated fibres an insulating filler material (e.g. solid, liquid, foam, gaseous pressurized or unpressurized), a housing (outside the insulating tube) made of polymeric material (for example silicone or ethylene-propylene) and metal fixing devices at the ends of the insulating tube. Composite hollow core station post insulators as defined in this standard are intended for general use in substations in both, outdoor and indoor environments, operating with a rated AC voltage greater than 1 000 V and a frequency not greater than 100 Hz or for use in direct current systems with a rated voltage greater than 1 500 V. The object of this standard is: - to define the terms used; - to prescribe test methods; - to prescribe acceptance criteria. All the tests in this standard, apart from the thermal-mechanical test, are performed at normal ambient temperature. This standard does not prescribe tests that may be characteristic of the apparatus of which the composite hollow core station post insulator ultimately may form a part.

  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62282-3-400:2016 applies to small stationary fuel cell power systems serving as a heating appliance providing both electric power and useful heat with or without a supplementary heat generator providing peak load function. This standard applies to fuel cell power systems that are intended to be permanently connected to the electrical system of the customer (end user). Direct connection to the mains (parallel operation) is also within the scope of this standard. This standard is limited to gas and liquid fuelled fuel cell CHP appliances that have a heat input based on lower heating value of less than or equal to 70 kW. This standard specifies the requirements for construction, safety, installation, fitness for purpose, rational use of energy, marking, and performance measurement of these appliances. This standard also provides regional and country specific requirements to facilitate the worldwide application of this IEC standard.

  • Standard
    399 pages
    English and French language
    sale 15% off

Prescribes specified values for the mechanical characteristics of the composite string insulator units. Defines the main dimensions of the couplings to be used on the composite string insulator units in order to permit the assembly of insulators of fittings supplied by different manufacturers and to allow, whenever practical, interchangeability with existing installations. It also defines a standard designation system for composite string insulator units.

  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    27 pages
    French language
    sale 10% off
    e-Library read for
    1 day
  • Standard – translation
    25 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day

IEC TS 60815-4:2016(E) which is a Technical Specification, is applicable as first approach for the determination of the required d.c. Unified Specific Creepage Distance for insulators with respect to pollution. To avoid excessive over or under design, existing operation experience should be compared and eventually additional appropriate tests may be performed by agreement between supplier and customer. It is applicable to:
- Glass and porcelain insulators;
- Composite and hybrid insulators with an HTM or non-HTM housing. This part of IEC 60815 gives specific guidelines and principles to arrive at an informed judgement on the probable behaviour of a given insulator in certain pollution environments.

  • Technical specification
    29 pages
    English language
    sale 15% off

IEC 62772:2016 applies to composite hollow core station post insulators consisting of a load-bearing insulating tube (core) made of resin impregnated fibres an insulating filler material (e.g. solid, liquid, foam, gaseous pressurized or unpressurized), a housing (outside the insulating tube) made of polymeric material (for example silicone or ethylene-propylene) and metal fixing devices at the ends of the insulating tube. Composite hollow core station post insulators as defined in this standard are intended for general use in substations in both, outdoor and indoor environments, operating with a rated AC voltage greater than 1 000 V and a frequency not greater than 100 Hz or for use in direct current systems with a rated voltage greater than 1 500 V. The object of this standard is:
- to define the terms used;
- to prescribe test methods;
- to prescribe acceptance criteria.
All the tests in this standard, apart from the thermal-mechanical test, are performed at normal ambient temperature. This standard does not prescribe tests that may be characteristic of the apparatus of which the composite hollow core station post insulator ultimately may form a part.

  • Standard
    45 pages
    English and French language
    sale 15% off

Prescribes specified values for the mechanical characteristics of the composite string insulator units. Defines the main dimensions of the couplings to be used on the composite string insulator units in order to permit the assembly of insulators of fittings supplied by different manufacturers and to allow, whenever practical, interchangeability with existing installations. It also defines a standard designation system for composite string insulator units.

  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    27 pages
    French language
    sale 10% off
    e-Library read for
    1 day
  • Standard – translation
    25 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day

IEC 61000-4-9:2016 is available as IEC 61000-4-9:2016 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61000-4-9:2016 specifies the immunity requirements, test methods, and range of recommended test levels for equipment subjected to impulse magnetic disturbances mainly encountered in industrial installations, power plants, railway installations, and medium voltage and high voltage sub-stations. This second edition cancels and replaces the first edition published in 1993 and Amendment 1:2000. This edition constitutes a technical revision.

  • Standard
    109 pages
    English and French language
    sale 15% off

This International Standard specifies characteristics for composite insulators of electric traction
overhead contact line systems for railways, as defined in IEC 60913. Insulators specified in this
standard are applied for electric traction supply voltages with a nominal voltage greater than
1 000 V for a.c. or a nominal voltage greater than 1 500 V for d.c.. Specific applications where
high torsional loads can occur are outside the scope of this standard and particular tests are
agreed between the supplier and customer to represent the critical loading arrangements.
This International Standard applies to composite insulators as defined in 3.1 below and not to
other polymeric insulators.
The provisions contained in this standard are intended for the design and construction of new
electric traction overhead contact line systems using insulators, or when complete
refurbishment of existing overhead contact line systems takes place.
This standard provides the purchaser and manufacturer with a range of tests which are used to
evaluate the suitability of an insulator product for a given railway environment. Additional tests
may be specified by the client to measure the compliance of the insulator under particular
operating conditions.
The standard establishes the product characteristics, the test methods and acceptance criteria.
The object of this standard is to stipulate the provisions for the design and provision of the
service indicated by the manufacturer to the customer or informed buyer for application on the
railway infrastructure.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61466-1:2016 is applicable to composite string insulator units for a.c. overhead lines with a nominal voltage greater than 1 000 V and a frequency not greater than 100 Hz. It also applies to insulators of similar design used in substations or on electric traction lines. This standard applies to string insulator units of composite type with ball, socket, tongue, clevis, Y-clevis or eye couplings, or a combination thereof. The object of this standard is to prescribe specified values for the mechanical characteristics of the composite string insulator units and define the main dimensions of the couplings to be used on the composite string insulator units in order to permit the assembly of insulators or fittings supplied by different manufacturers and to allow, whenever practical, interchangeability with existing installations. It also defines a standard designation system for composite string insulator units. This edition includes the following significant technical changes with respect to the previous edition:
a) Addition of strength classes reflecting UHV practice;
b) Inclusion of Corrigendum 1:2008 for Y fitting hole dimensions.

  • Standard
    46 pages
    English and French language
    sale 15% off

This part of IEC 62231 is applicable to composite station post insulators for substations with
a.c. voltages greater than 1 000 V up to 245 kV.
It also applies to composite station post insulators of similar design used in power stations of
railway systems.
This part of IEC 62231 specifies main dimensions and values for mechanical and electrical
characteristics of composite station post insulators.
NOTE The composite station post insulators covered by this standard are primarily intended for outdoor service,
but can also be used indoor.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC TS 62073:2016(E) specifies the measurement of the hydrophobicity of the shed and housing material of composite insulators for overhead lines, substations and equipment or ceramic insulators covered or not covered by a coating. The obtained value represents the hydrophobicity at the time of the measurement. The object of this technical specification is to describe three methods that can be used to determine the hydrophobicity of insulators. The determination of the ability of water to wet the surface of insulators may be useful to evaluate the condition of the surface of insulators in service, or as part of the insulator testing in the laboratory. This second edition cancels and replaces the first edition published in 2003. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) Changed wettability to hydrophobicity throughout the document
b) Redefined the criteria for the determination of hydrophobicity class in paragraph 3.4.

  • Technical specification
    20 pages
    English language
    sale 15% off

IEC 62231-1:2015 specifies main dimensions and values for mechanical and electrical characteristics of composite station post insulators.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC TS 62896:2015(E) applies to hybrid insulators for a.c. and d.c. applications consisting of a load-bearing insulating solid or hollow core consisting of ceramic or glass, a housing (defined geometry, outside the insulating core) made of polymeric material and end fittings permanently attached to the insulating core. Hybrid insulators covered by this technical specification are intended for use as suspension/tension line insulators, line post insulators, station post insulators and hollow core insulators for apparatus. The object of this technical specification is to:
- define the terms used;
- prescribe test methods;
- prescribe acceptance criteria.
Silicone or other functional coatings (CIGRE Technical Brochure No. 478, Appendix B), booster sheds, shed extenders and rain deflectors are not within the scope of this technical specification. This technical specification does not include requirements dealing with the choice of insulators for specific operating conditions.

  • Technical specification
    18 pages
    English language
    sale 15% off

IEC 62231-1:2015 specifies main dimensions and values for mechanical and electrical characteristics of composite station post insulators.

  • Standard
    29 pages
    English and French language
    sale 15% off

IEC TS 61245:2015(E) is applicable for the determination of the d.c. withstand characteristics of ceramic and glass insulators to be used outdoors and exposed to polluted atmospheres, on d.c. systems with the highest voltage of the system greater than +/- 1 000 V. These tests are not applicable to polymeric insulators, to greased insulators or to special types of insulators (e.g. insulators with semiconducting glaze or covered with any organic insulating material). The object of this technical specification is to prescribe procedures for artificial pollution tests applicable to insulators for overhead lines, substations and traction lines and to bushings. This second edition cancels and replaces the first edition published in 1993. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) Corrections and the addition of explanatory material;
b) The addition of Clause 4.4.2 on atmospheric correction;
c) The change of upper limit of volume conductivity of tap water for insulator cleaning to 0,1 S/m;
d) The extension to UHV voltages; and
e) The addition of Annex B "Determination of the withstand characteristics of insulators" and Annex E "Supplementary information on artificial pollution tests on insulators for voltage systems of +/- 600 kV and above (solid layer method procedure B).
The contents of the corrigendum of August 2018 have been included in this copy.

  • Technical specification
    36 pages
    English language
    sale 15% off

EN IEC 60507 is applicable for the determination of the power frequency withstand characteristics of ceramic and glass insulators to be used outdoors and exposed to polluted atmospheres, on a.c. systems with the highest voltage of the system greater than 1 000 V. These tests are not directly applicable to polymeric insulators, to greased insulators or to special types of insulators (insulators with semiconducting glaze or covered with any organic insulating material). The object of this International Standard is to prescribe procedures for artificial pollution tests applicable to insulators for overhead lines, substations and traction lines and to bushings It may also be applied to hollow insulators with suitable precautions to avoid internal flashover. In applying these procedures to apparatus incorporating hollow insulators, the relevant technical committees should consider their effect on any internal equipment and the special precautions which may be necessary.

  • Standard
    41 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    41 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61966-12-1:2014(en) specifies the colour gamut metadata format for video systems intended for use in CE (Consumer Electronics) devices. The metadata specified in this part of IEC 61966 is limited to the gamut description of additive three primary colours type displays whose white and black points have the same chromaticity. It is fundamentally based on the conventional VESA-EDID format.

  • Standard
    17 pages
    English language
    sale 15% off

IEC 60507:2013 is applicable for the determination of the power frequency withstand characteristics of ceramic and glass insulators to be used outdoors and exposed to polluted atmospheres, on a.c. systems with the highest voltage of the system greater than 1 000 V. These tests are not directly applicable to polymeric insulators, to greased insulators or to special types of insulators (insulators with semiconducting glaze or covered with any organic insulating material). The object of this International Standard is to prescribe procedures for artificial pollution tests applicable to insulators for overhead lines, substations and traction lines and to bushings. It may also be applied to hollow insulators with suitable precautions to avoid internal flashover. In applying these procedures to apparatus incorporating hollow insulators, the relevant technical committees should consider their effect on any internal equipment and the special precautions which may be necessary. This edition includes the following significant technical changes with respect to the previous edition: a) Corrections and the addition of explanatory material; b) The addition of Clause 4.3.2 on atmospheric correction; c) The change of the upper limit of conductivity of water to 0.1 S/m; and d) The extension to UHV voltages.

  • Standard
    41 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    41 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60507:2013 is applicable for the determination of the power frequency withstand characteristics of ceramic and glass insulators to be used outdoors and exposed to polluted atmospheres, on a.c. systems with the highest voltage of the system greater than 1 000 V. These tests are not directly applicable to polymeric insulators, to greased insulators or to special types of insulators (insulators with semiconducting glaze or covered with any organic insulating material). The object of this International Standard is to prescribe procedures for artificial pollution tests applicable to insulators for overhead lines, substations and traction lines and to bushings. It may also be applied to hollow insulators with suitable precautions to avoid internal flashover. In applying these procedures to apparatus incorporating hollow insulators, the relevant technical committees should consider their effect on any internal equipment and the special precautions which may be necessary. This edition includes the following significant technical changes with respect to the previous edition:
a) Corrections and the addition of explanatory material;
b) The addition of Clause 4.3.2 on atmospheric correction;
c) The change of the upper limit of conductivity of water to 0.1 S/m; and
d) The extension to UHV voltages.
The contents of the corrigendum of August 2018 have been included in this copy.

  • Standard
    77 pages
    English and French language
    sale 15% off

IEC 61786-1:2013 provides guidance for measuring instruments used to measure the field strength of quasi-static magnetic and electric fields that have a frequency content in the range 1 Hz to 100 kHz and with DC magnetic fields to evaluate the exposure levels of the human body to these fields. Sources of fields include devices that operate at power frequencies and produce power frequency and power frequency harmonic fields, as well as devices that produce fields within the frequency range of this document, including devices that produce static fields, and the earth's static magnetic field. The magnitude ranges covered by this standard are 0,1 μT to 200 mT in AC (1 μT to 10 T in DC) and 1 V/m to 50 kV/m for magnetic fields and electric fields, respectively. When measurements outside this range are performed, most of the provisions of this standard will still apply, but special attention should be paid to specified uncertainty and calibration procedures. The first editions of IEC 61786-1 and IEC 61786-2 replace IEC 61786:1998. Part 1 deals with measuring instruments, and Part 2 deals with measurement procedures. The content of the standard was revised in order to give up-to-date and practical information to the user.
It has the status of a horizontal standard in accordance with IEC Guide 108.

  • Standard
    110 pages
    English and French language
    sale 15% off

Applies to string insulator units of the can and pin type and also of the long rod type as well as to the fittings used with such insulators. Defines dimensions of a series of clevis and tongue couplings to permit the assembly of insulators or fittings supplied by different manufacturers.[
]Note: -For co-ordination between standardized dimensions and strength classes of cap and pin type insulators and long rod type insulators see IEC 60305 and 60433.

  • Standard
    13 pages
    English and French language
    sale 15% off

IEC 60743:2013 applies to the terminology used to describe tools, devices, equipment and methods used in live working. It standardizes the name of tools, devices and equipment and permits their identification by providing definitions and illustrations. It contains some example illustrations. This third edition cancels and replaces the second edition, published in 2001, and its Amendment 1:2008.This edition constitutes a technical revision which includes the following significant technical changes with respect to the previous edition: the clause 2 has been simplified and refers directly to IEC 60050-651; some definitions have been moved to specific existing clauses. This new edition is complementary to IEC 60050-651. Different publications under the responsibility of TC 78 include terms and its definitions. IEC 60050-651 (IEV 651) provides precise, brief and correct definitions of internationally accepted concepts in the field of live working, and specifies the terms by which these defined concepts are known. Electropedia gives access to the terms and definitions of IEC 60050-651 (http://www.electropedia.org/). Each product standard gives definitions necessary for the understanding of certain terms used in a specific context. The IEC Glossary (http://std.iec.ch/glossary) gives on-line access to the information.

  • Standard
    128 pages
    English and French language
    sale 15% off

IEC 62264-2:2013 specifies generic interface content exchanged between manufacturing control functions and other enterprise functions. The interface considered is between Level 3 manufacturing systems and Level 4 business systems in the hierarchical model defined in IEC 62264-1. The goal is to reduce the risk, cost, and errors associated with implementing the interface. This second edition cancels and replaces the first edition published in 2004 and constitutes a technical revision. It includes the following technical:
- addition of object models for exchange information used in manufacturing operations management activities;
- displacement of the UML object models that were in IEC 62264-1:2003 into this standard so that the object models and the associated attribute tables were available in the same document;
- addition of the Hierarchy scope object definition to replace the Location attribute used in the previous edition;
- addition of a value type section to define the exchange of non-simple value types;
- definition of simple value types were defined using the ISO 15000-5.

  • Standard
    358 pages
    English and French language
    sale 15% off

This International Standard is applicable to polymeric insulators whose insulating body consists of one or various organic materials. Polymeric insulators covered by this standard include both solid core and hollow insulators. They are intended for use on HV overhead lines and in indoor and outdoor equipment. The object of this standard is
– to define the common terms used for polymeric insulators;
– to prescribe common test methods for design tests on polymeric insulators;
– to prescribe acceptance or failure criteria, if applicable;
These tests, criteria and recommendations are intended to ensure a satisfactory life-time under normal operating and environmental conditions (see Clause 5). This standard shall only be applied in conjunction with the relevant product standard.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    29 pages
    French language
    sale 10% off
    e-Library read for
    1 day
  • Standard – translation
    29 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day

IEC 62217:2012 is applicable to polymeric insulators whose insulating body consists of one or various organic materials. Polymeric insulators covered by this standard include both solid core and hollow insulators. They are intended for use on HV overhead lines and in indoor and outdoor equipment. The object of this standard is: - to define the common terms used for polymeric insulators; - to prescribe common test methods for design tests on polymeric insulators; - to prescribe acceptance or failure criteria, if applicable. These tests, criteria and recommendations are intended to ensure a satisfactory life-time under normal operating and environmental conditions. This standard shall only be applied in conjunction with the relevant product standard. This second edition cancels and replaces the first edition published in 2005. This edition constitutes a technical revision. This edition includes a significant technical change with respect to the previous edition. The first edition of IEC 62217 (2005) included two other alternative tracking and erosion tests (a 5 000 hour multi-stress test and a tracking wheel test) which were based on tests developed by CIGRE and utilities. These tests are no longer given as normative alternatives following the results of a study/questionnaire by TC 36 on the relative merits of all three tracking and erosion tests. The 5 000 hour multi-stress test and a tracking wheel test are described in IEC/TR 62730 (2012).

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    29 pages
    French language
    sale 10% off
    e-Library read for
    1 day
  • Standard – translation
    29 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day

IEC 61850-10:2012 specifies standard techniques for testing of conformance of client, server and sampled value devices and engineering tools, as well as specific measurement techniques to be applied when declaring performance parameters. The use of these techniques will enhance the ability of the system integrator to integrate IEDs easily, operate IEDs correctly, and support the applications as intended. The major technical changes with regard to the previous edition are as follows:
- updates to server device conformance test procedures;
- additions of certain test procedures (client device conformance, sampled values device conformance, (engineering) tool related conformance, GOOSE performance).

  • Standard
    170 pages
    English and French language
    sale 15% off

IEC 62217:2012 is applicable to polymeric insulators whose insulating body consists of one or various organic materials. Polymeric insulators covered by this standard include both solid core and hollow insulators. They are intended for use on HV overhead lines and in indoor and outdoor equipment. The object of this standard is:
- to define the common terms used for polymeric insulators;
- to prescribe common test methods for design tests on polymeric insulators;
- to prescribe acceptance or failure criteria, if applicable.
These tests, criteria and recommendations are intended to ensure a satisfactory life-time under normal operating and environmental conditions. This standard shall only be applied in conjunction with the relevant product standard. This second edition cancels and replaces the first edition published in 2005. This edition constitutes a technical revision. This edition includes a significant technical change with respect to the previous edition. The first edition of IEC 62217 (2005) included two other alternative tracking and erosion tests (a 5 000 hour multi-stress test and a tracking wheel test) which were based on tests developed by CIGRE and utilities. These tests are no longer given as normative alternatives following the results of a study/questionnaire by TC 36 on the relative merits of all three tracking and erosion tests. The 5 000 hour multi-stress test and a tracking wheel test are described in IEC/TR 62730 (2012).

  • Standard