This European Prestandard establishes the Healthcare Information Framework (HIF) as a logical mappling between the healthcare environment and informatics applications which support and facilitate clinical and other functions. This European Prestandard specifies the set of requirements, recommendations and guidelines which apply to developments within CEN/TC 251 which enable consistent development and evolution of healthcare domain specific informatics standards.
Medicinska informatika – Okvirne določbe o informacijah o zdravstvenem varstvu (HIF)
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
01-oktober-2003
0HGLFLQVNDLQIRUPDWLND±2NYLUQHGRORþEHRLQIRUPDFLMDKR]GUDYVWYHQHPYDUVWYX
+,)
Medical Informatics - Healthcare Information Framework (HIF)
Ta slovenski standard je istoveten z: ENV 12443:1999
ICS:
35.240.80 Uporabniške rešitve IT v IT applications in health care
zdravstveni tehniki technology
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
...
This May Also Interest You
This document is intended for use by parties to the design, development, acquisition, use and monitoring of health-care related information and information systems. It provides a list of units of measurement to be used in representing values of measurable quantities in health sciences.
The International System of Units forms the basis for this EN. Units with their associated kinds-of-quantity are arranged in order of dimension in Tables 1, 2 and 4 (Clause 5), and in Annex A.
Different kinds-of-quantity may apply to a given combination of component(s) and system. Often the different quantities are interconvertible and examples of such interconvertibility are given in Annex C.
Tables of conversion factors (Annex A) are provided from units in current use to SI units or their multiples.
To represent the result of a measurement (Clause 6), this EN addresses requirements for the following:
¾ relational operator (Clause 4)
¾ numerical value (Subclause 6.1)
¾ uncertainty of measurement (Subclause 6.2; Annex D)
¾ unit of measurement (Clause 5).
This EN covers the requirements for representation of these data elements in displayed and printed form, and provides an approach for support of languages in non-Roman alphabets (Clause 7).
The scope of this standard is limited to textual representation. Support is not provided for the display or printing of images or graphs.
This standard does not cover the requirements for expression of the results of measurements in speech, speech synthesis or handwriting. It does not cover the form and syntax of requests for clinical measurements, nor detailed aspects of data transmission. It refers the user to other CEN standards that address the detailed specification of the interchange format. It does not address the syntax for recording of natural-language statements about quantities, such as those used in recording information about drugs dispensed or about treatment of patients. It does not cover the units of financial quantitie
- Standard116 pagesEnglish languagesale 10% offe-Library read for×1 day
This document is intended for use by parties to the design, development, acquisition, use and monitoring of health-care related information and information systems. It provides a list of units of measurement to be used in representing values of measurable quantities in health sciences.
The International System of Units forms the basis for this EN. Units with their associated kinds-of-quantity are arranged in order of dimension in Tables 1, 2 and 4 (Clause 5), and in Annex A.
Different kinds-of-quantity may apply to a given combination of component(s) and system. Often the different quantities are interconvertible and examples of such interconvertibility are given in Annex C.
Tables of conversion factors (Annex A) are provided from units in current use to SI units or their multiples.
To represent the result of a measurement (Clause 6), this EN addresses requirements for the following:
¾ relational operator (Clause 4)
¾ numerical value (Subclause 6.1)
¾ uncertainty of measurement (Subclause 6.2; Annex D)
¾ unit of measurement (Clause 5).
This EN covers the requirements for representation of these data elements in displayed and printed form, and provides an approach for support of languages in non-Roman alphabets (Clause 7).
The scope of this standard is limited to textual representation. Support is not provided for the display or printing of images or graphs.
This standard does not cover the requirements for expression of the results of measurements in speech, speech synthesis or handwriting. It does not cover the form and syntax of requests for clinical measurements, nor detailed aspects of data transmission. It refers the user to other CEN standards that address the detailed specification of the interchange format. It does not address the syntax for recording of natural-language statements about quantities, such as those used in recording information about drugs dispensed or about treatment of patients. It does not cover the units of financial quantitie
- Standard116 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies the composition, tolerances and characteristics, i.e. mechanical, acoustic, optical and thermal properties, of folio interlayers for the manufacturing of laminated glass and laminated safety glass for use in buildings and construction works and it defines their general quality criteria.
This document does not apply to interlayers for laminated glass which are achieved by pouring the interlayer material in liquid state on or between the plies of glass or plastic glazing sheet material generally followed by drying or by chemical or ultraviolet curing.
- Draft13 pagesEnglish languagesale 10% offe-Library read for×1 day
- 11-Mar-2025
- 81.040.20
- CEN/TC 129
This document specifies requirements for washer-disinfectors (WD) that are intended to be used for emptying, flushing, washing and thermal disinfection of non-critical devices in the form of human waste containers by one operating cycle.
This document is intended to be used in conjunction with the general requirements specified in ISO 15883-1:2024, except for those specified in 4.1.1, and with the requirements of ISO 15883-5:2021, except for those specified in 4.1.2.
- Draft21 pagesEnglish languagesale 10% offe-Library read for×1 day
- 11-Mar-2025
- 11.080.10
- 2017/745
- M/575
- CEN/TC 102
This document specifies requirements for washer-disinfectors (WD) that are intended for use for the cleaning and thermal disinfection, in a single operating cycle, of reusable critical and semi-critical medical devices, such as surgical instruments, anaesthetic equipment, and any non-critical devices used in conjunction with critical and semi-critical medical devices, such as bowls, dishes and receivers, utensils and glassware.
This document is intended to be used in conjunction with the general requirements specified in ISO 15883-1:2024, except those specified in 4.1.1.
NOTE The specified performance requirements of this document cannot ensure the inactivation or removal of the causative agent(s) (prion protein) of transmissible spongiform encephalopathies.
- Draft24 pagesEnglish languagesale 10% offe-Library read for×1 day
- 11-Mar-2025
- 11.080.10
- 2017/745
- M/575
- CEN/TC 102
The standard contains guidelines for developing and establishing policies and procedures for deletion
of PII in organizations by specifying:
— a harmonized terminology for PII deletion;
— an approach for defining deletion rules in an efficient way;
— a description of required documentation; and
— a broad definition of roles, responsibilities and processes.
This document is intended to be used by organizations where PII are stored or processed.
This document does not address:
— specific legal provision, as given by national law or specified in contracts;
— specific deletion rules for particular clusters of PII as are to be defined by PII controllers for
— processing PII;
— deletion mechanisms;
— reliability, security and suitability of deletion mechanisms;
— specific techniques for de-identification of data.
- Draft31 pagesEnglish languagesale 10% offe-Library read for×1 day
- 11-Mar-2025
- 35.030
- 2016/679
- CEN/CLC/TC 13
This document specifies a method for determining the effect of heat on unplasticized poly(vinyl chloride) (PVC-U) profiles, to be carried out in air at 150 °C.
It is also applicable to PVC-based profiles at specified temperatures/test conditions.
- Draft5 pagesEnglish languagesale 10% offe-Library read for×1 day
- 11-Mar-2025
- 83.080.20
- 97.220.30
- 97.220.40
- CEN/TC 249
1.1 This document specifies the safety requirements for the construction and installation of power operated lifts attached to cranes and intended for access to workplaces on cranes. The lift serves defined landing levels and has a car which is:
a) designed for the transportation of persons and goods;
b) guided;
c) travelling vertically or along a path within 15 degrees maximum from the vertical;
d) supported by rack and pinion or suspended by steel wire ropes;
e) travelling with a speed not more than 1,0 m/s for permanent installed lifts and not more than 0,4 m/s for temporarily installed lifts.
1.2 This document identifies hazards as listed in Annex A that arise during the various phases in the life of such equipment and describes methods for the elimination or reduction of these hazards when used as intended by the manufacturer.
This document deals with significant hazards, hazardous situations and events relevant to lifts for cranes, when it is used as intended and under conditions of misuse which are reasonably foreseeable by the manufacturer. This document specifies the appropriate technical measures to eliminate or reduce risks arising from the significant hazards (see Annex A).
1.3 This document does not specify requirements for:
a) noise;
b) lighting;
c) potentially explosive atmospheres;
NOTE Directive 2014/34/EU concerning equipment and protective systems intended for use in potentially explosive atmospheres can be applicable to the type of machine or equipment covered by this document. The present standard is not intended to provide means of complying with the essential health and safety requirements of Directive 2014/34/EU.
d) electromagnetic compatibility (emission, immunity);
e) handling of loads the nature of which could lead to dangerous situations (e.g. molten metal, acids/bases, radiating materials, fragile loads);
f) the use of combustion engines;
g) hydraulic drive units.
1.4 This document is not applicable to:
a) builders hoists according to EN 12158 1:2021, EN 12158 2:2000+A1:2010 and EN 12159:2012 and transport platforms according to EN 16719:2018;
b) elevating control stations according to EN 14502 2:2005+A1:2008;
c) lifts according to EN 81 20:2020.
1.5 This document deals with the complete lift design but excludes the design of the crane. It includes the base frame and base enclosure of the lift but excludes the design of any concrete, hard core, timber or other foundation arrangement. It includes the design of mast ties and the design of anchorage parts between the mast tie and the crane structure. This document also includes the design of the landing gates and their fixings.
1.6 This document does not apply to lifts for cranes manufactured before the date of publication of this document by CEN.
- Draft80 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies principles for the design and selection (independent of the nature of the energy source) of interlocking devices associated with guards and provides guidance on measures to minimize the possibility of defeat of interlocking devices in a reasonably foreseeable manner.
This document covers principles for the design, selection and application of the following:
— parts of the guards which actuate interlocking devices;
— trapped key interlocking devices and systems for machinery applications.
NOTE ISO 14120 specifies general requirements for the design and construction of guards provided primarily to protect persons from mechanical hazards. The processing of the signal from the interlocking device to stop the machine and prevent unexpected start up is covered in ISO 14118, ISO 13849-1 and IEC 62061.
- Draft121 pagesEnglish languagesale 10% offe-Library read for×1 day
- 11-Mar-2025
- 31-Jan-2023
- 13.110
- 2006/42/EC
- M/396
- CEN/TC 114
- Draft11 pagesEnglish languagesale 10% offe-Library read for×1 day
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.