EN 60896-21:2004
(Main)Stationary lead-acid batteries - Part 21: Valve regulated types - Methods of test
Stationary lead-acid batteries - Part 21: Valve regulated types - Methods of test
This part of EN 60896 applies to all stationary lead-acid cells and monobloc batteries of the valve regulated type for float charge applications, (i.e. permanently connected to a load and to a d.c. power supply), in a static location (i.e. not generally intended to be moved from place to place) and incorporated into stationary equipment or installed in battery rooms for use in telecom, uninterruptible power supply (UPS), utility switching, emergency power or similar applications. The objective of this part of EN 60896 is to specify the methods of test for all types and construction of valve regulated stationary lead acid cells and monobloc batteries used in standby power applications
Ortsfeste Blei-Akkumulatoren - Teil 21: Verschlossene Bauarten - Prüfverfahren
Batteries stationnaires au plomb - Partie 21: Types étanches à soupapes - Méthodes d'essais
La présente partie de la EN 60896 s'applique à tous les éléments et batteries monoblocs stationnaires au plomb de type étanche à soupapes pour les applications en charge flottante, (c'est-à-dire connectés en permanence à une charge et à une source d'alimentation continue), à un emplacement fixe (c'est-à-dire n'étant pas prévus pour être déplacés d'un emplacement à l'autre) et incorporés dans un matériel stationnaire ou installés dans un local pour batteries pour des applications telles que: télécommunication, alimentation sans interruption (ASI), commutation, alimentation de secours ou applications similaires. Le but de cette partie de la EN 60896 est de spécifier les méthodes d'essai pour tous les types et constructions d'éléments ou batteries monoblocs stationnaires au plomb de type étanche à soupapes utilisées dans les applications d'alimentation de secours.
Stationary lead-acid batteries - Part 21: Valve regulated types - Methods of test
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-maj-2004
1DGRPHãþD
SIST EN 60896-2:1997
Stationary lead-acid batteries - Part 21: Valve regulated types - Methods of test
Stationary lead-acid batteries -- Part 21: Valve regulated types - Methods of test
Ortsfeste Blei-Akkumulatoren -- Teil 21: Verschlossene Bauarten - Prüfverfahren
Batteries stationnaires au plomb -- Partie 21: Types étanches à soupapes - Méthodes
d'essais
Ta slovenski standard je istoveten z: EN 60896-21:2004
ICS:
29.220.20 .LVOLQVNLVHNXQGDUQLþOHQLLQ Acid secondary cells and
EDWHULMH batteries
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD EN 60896-21
NORME EUROPÉENNE
EUROPÄISCHE NORM March 2004
ICS 29.220.20 Supersedes EN 60896-2:1996
English version
Stationary lead-acid batteries
Part 21: Valve regulated types –
Methods of test
(IEC 60896-21:2004)
Batteries stationnaires au plomb Ortsfeste Blei-Akkumulatoren
Partie 21: Types étanches à soupapes - Teil 21: Verschlossene Bauarten -
Méthodes d'essais Prüfverfahren
(CEI 60896-21:2004) (IEC 60896-21:2004)
This European Standard was approved by CENELEC on 2004-03-01. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and
notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden,
Switzerland and United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2004 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60896-21:2004 E
Foreword
The text of document 21/594/FDIS, future edition 1 of IEC 60896-21, prepared by IEC TC 21,
Secondary cells and batteries, was submitted to the IEC-CENELEC parallel vote and was approved by
CENELEC as EN 60896-21 on 2004-03-01.
This European Standard supersedes EN 60896-2:1996.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2004-12-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2007-03-01
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 60896-21:2004 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:
IEC 60050-826 NOTE Harmonized as HD 384.2 S1:1986 (not modified).
IEC 60095 NOTE Harmonized in EN 60095 series (partly modified).
IEC 61056 NOTE Harmonized in EN 61056 series (not modified).
IEC 61427 NOTE Harmonized as EN 61427:2001 (not modified).
ISO 9000 NOTE Harmonized as EN ISO 9000:2000 (not modified).
ISO 9001 NOTE Harmonized as EN ISO 9001:1994 (not modified).
ISO 9001 NOTE Harmonized as EN ISO 9001:2000 (not modified).
__________
- 3 - EN 60896-21:2004
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
Publication Year Title EN/HD Year
IEC 60068-2-32 1975 Basic environmental testing procedures
Part 2: Tests - Test Ed: Free fall
(Procedure 1)
+ A2 1990 HD 323.2.32 S2 1991
1) 2)
IEC 60695-11-10 - Fire hazard testing EN 60695-11-10 1999
Part 11-10: Test flames - 50 W
horizontal and vertical flame test
methods
1) 2)
IEC 60707 - Flammability of solid non-metallic EN 60707 1999
materials when exposed to flame
sources - List of test methods
IEC 60896-22 2004 Stationary lead-acid batteries EN 60896-22
Part 22: Valve regulated types –
Requirements
IEC 60950-1 2001 Information technology equipment - EN 60950-1 2001
(mod) Safety
Part 1: General requirements
IEC 61430 1997 Secondary cells and batteries - Test - -
methods for checking the performance
of devices designed for reducing
explosion hazards - Lead-acid starter
batteries
ISO 1043-1 2001 Plastics - Symbols and abbreviated - -
terms
Part 1: Basic polymers and their special
characteristics
1)
Undated reference.
2)
Valid edition at date of issue.
NORME CEI
INTERNATIONALE IEC
60896-21
INTERNATIONAL
Première édition
STANDARD
First edition
2004-02
Batteries stationnaires au plomb –
Partie 21:
Types étanches à soupapes –
Méthodes d'essai
Stationary lead-acid batteries –
Part 21:
Valve regulated types –
Methods of test
IEC 2004 Droits de reproduction réservés Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in any
utilisée sous quelque forme que ce soit et par aucun procédé, form or by any means, electronic or mechanical, including
y compris la photocopie et les photocopying and microfilm, without permission in writing from
électronique ou mécanique,
microfilms, sans l'accord écrit de l'éditeur. the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
CODE PRIX
W
PRICE CODE
Commission Electrotechnique Internationale
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
Pour prix, voir catalogue en vigueur
For price, see current catalogue
60896-21 IEC:2004 – 3 –
CONTENTS
FOREWORD.5
1 Scope.9
2 Normative references .9
3 Definitions .11
4 Functional characteristics .21
5 Test set-up .25
6 Test methods.33
Bibliography.79
Figure 1 – Suggested layout for the test.33
Figure 2 – Typical test circuit .41
Figure 3 – Test fixture (IEC 61430) .43
Figure 4 – Orientation of the cell or monobloc battery in the test.45
Figure 5 – Suggested test circuit (fuse protected d.c. source) for the evaluation of
ground short propensity .45
Figure 6 – U-shaped tubing for the detection of gas flow through the valve .51
Figure 7 – Top view of the arrangement for monobloc batteries and single cells .69
Figure 8 – Top view of the arrangement for front-access monobloc batteries .71
Figure 9 – Impact locations.77
Figure 10 – Configuration for the shortest edge drop test.77
Figure 11 – Configuration for the corner drop test.77
Table 1 – Safe operation characteristics .23
Table 2 – Performance characteristics .23
Table 3 – Durability characteristics .25
Table 4 – Safe operation characteristics .31
Table 5 – Performance characteristics .31
Table 6 – Durability characteristics .31
Table 7 – Spark test according to IEC 61430 (for a venting system only) .43
Table 8 – Final voltage de-rating factor in commissioning or acceptance test.55
Table 9 – List of results of float service with daily discharges .59
Table 10 – Summary of results of float service with daily discharges .61
Table 11 – Data report .73
60896-21 IEC:2004 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
STATIONARY LEAD-ACID BATTERIES –
Part 21: Valve regulated types –
Methods of test
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60896-21 has been prepared by IEC technical committee 21:
Secondary cells and batteries.
This standard cancels and replaces IEC 60896-2 published in 1995.
The text of this standard is based on the following documents:
FDIS Report on voting
21/594/FDIS 21/600/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
-------------------
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.