Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models, instrumentation, and procedures - Part 1: Procedure to determine the specific absorption rate (SAR) for hand-held devices used in close proximity to the ear (frequency range of 300 MHz to 3 GHz)

Applies to any electromagnetic field (EMF) transmitting device intended to be used with the radiating part of the device in close proximity to the human head and held against the ear, including mobile phones, cordless phones, etc. The frequency range is 300 MHz to 3 GHz. The objective of this standard is to specify the measurement method for demonstration of compliance with the specific absorption rate (SAR) limits for such devices.

Exposition humaine aux champs radiofréquence produits par les dispositifs de communications sans fils tenus à la main ou portés près du corps - Modèles de corps humain, instrumentation et procédures - Partie 1: Détermination du débit d'absorption spécifique (DAS) produit par les appareils tenus à la main et utilisés près de l'oreille (plage de fréquence de 300 MHz à 3 GHz)

S'applique aux appareils de communication tels que les téléphones mobiles, les téléphones sans fil, etc., émettant des champs électromagnétiques (EMF) et qui sont destinés à être utilisés tenus contre l'oreille, la partie rayonnante étant proche de la tête. La gamme de fréquences s'étend de 300 MHz à 3 GHz. L'objectif de cette norme est de spécifier la méthode de mesure permettant de démontrer la conformité avec les limites de débit d'absorption spécifique (DAS) applicables à de tels appareils.

General Information

Status
Published
Publication Date
17-Feb-2005
Current Stage
DELPUB - Deleted Publication
Start Date
06-Jul-2016
Completion Date
26-Oct-2025
Ref Project

Relations

Standard
iec62209-1{ed1.0}b - IEC 62209-1:2005 - Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models, instrumentation, and procedures - Part 1: Procedure to determine the specific absorption rate (SAR) for hand-held devices used in close proximity to the ear (frequency range of 300 MHz to 3 GHz) Released:2/18/2005 Isbn:2831878535
English and French language
215 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NORME CEI
INTERNATIONALE IEC
62209-1
INTERNATIONAL
Première édition
STANDARD
First edition
2005-02
Exposition humaine aux champs radiofréquence
produits par les dispositifs de communications
sans fils tenus à la main ou portés près du corps –
Modèles de corps humain, instrumentation
et procédures –
Partie 1:
Détermination du débit d'absorption spécifique
(DAS) produit par les appareils tenus à la main
et utilisés près de l'oreille (plage de fréquence
de 300 MHz à 3 GHz)
Human exposure to radio frequency fields
from hand-held and body-mounted wireless
communication devices – Human models,
instrumentation, and procedures –
Part 1:
Procedure to determine the specific absorption
rate (SAR) for hand-held devices used in close
proximity to the ear (frequency range of
300 MHz to 3 GHz)
Numéro de référence
Reference number
CEI/IEC 62209-1:2005
Numérotation des publications Publication numbering
Depuis le 1er janvier 1997, les publications de la CEI As from 1 January 1997 all IEC publications are
sont numérotées à partir de 60000. Ainsi, la CEI 34-1 issued with a designation in the 60000 series. For
devient la CEI 60034-1. example, IEC 34-1 is now referred to as IEC 60034-1.
Editions consolidées Consolidated editions
Les versions consolidées de certaines publications de la The IEC is now publishing consolidated versions of its
CEI incorporant les amendements sont disponibles. Par publications. For example, edition numbers 1.0, 1.1
exemple, les numéros d’édition 1.0, 1.1 et 1.2 indiquent and 1.2 refer, respectively, to the base publication,
respectivement la publication de base, la publication de the base publication incorporating amendment 1 and
base incorporant l’amendement 1, et la publication de the base publication incorporating amendments 1
base incorporant les amendements 1 et 2. and 2.
Informations supplémentaires Further information on IEC publications
sur les publications de la CEI
Le contenu technique des publications de la CEI est The technical content of IEC publications is kept
constamment revu par la CEI afin qu'il reflète l'état under constant review by the IEC, thus ensuring that
actuel de la technique. Des renseignements relatifs à the content reflects current technology. Information
cette publication, y compris sa validité, sont dispo- relating to this publication, including its validity, is
nibles dans le Catalogue des publications de la CEI available in the IEC Catalogue of publications
(voir ci-dessous) en plus des nouvelles éditions, (see below) in addition to new editions, amendments
amendements et corrigenda. Des informations sur les and corrigenda. Information on the subjects under
sujets à l’étude et l’avancement des travaux entrepris consideration and work in progress undertaken by the
par le comité d’études qui a élaboré cette publication, technical committee which has prepared this
ainsi que la liste des publications parues, sont publication, as well as the list of publications issued,
également disponibles par l’intermédiaire de: is also available from the following:
• Site web de la CEI (www.iec.ch) • IEC Web Site (www.iec.ch)
• Catalogue des publications de la CEI • Catalogue of IEC publications
Le catalogue en ligne sur le site web de la CEI The on-line catalogue on the IEC web site
(www.iec.ch/searchpub) vous permet de faire des (www.iec.ch/searchpub) enables you to search by a
recherches en utilisant de nombreux critères, variety of criteria including text searches,
comprenant des recherches textuelles, par comité technical committees and date of publication. On-
d’études ou date de publication. Des informations en line information is also available on recently
ligne sont également disponibles sur les nouvelles issued publications, withdrawn and replaced
publications, les publications remplacées ou retirées, publications, as well as corrigenda.
ainsi que sur les corrigenda.
• IEC Just Published • IEC Just Published
Ce résumé des dernières publications parues This summary of recently issued publications
(www.iec.ch/online_news/justpub) est aussi dispo- (www.iec.ch/online_news/justpub) is also available
nible par courrier électronique. Veuillez prendre by email. Please contact the Customer Service
contact avec le Service client (voir ci-dessous) Centre (see below) for further information.
pour plus d’informations.
• Service clients • Customer Service Centre
Si vous avez des questions au sujet de cette If you have any questions regarding this
publication ou avez besoin de renseignements publication or need further assistance, please
supplémentaires, prenez contact avec le Service contact the Customer Service Centre:
clients:
Email: custserv@iec.ch Email: custserv@iec.ch
Tél: +41 22 919 02 11 Tel: +41 22 919 02 11
Fax: +41 22 919 03 00 Fax: +41 22 919 03 00
.
NORME CEI
INTERNATIONALE IEC
62209-1
INTERNATIONAL
Première édition
STANDARD
First edition
2005-02
Exposition humaine aux champs radiofréquence
produits par les dispositifs de communications
sans fils tenus à la main ou portés près du corps –
Modèles de corps humain, instrumentation
et procédures –
Partie 1:
Détermination du débit d'absorption spécifique
(DAS) produit par les appareils tenus à la main
et utilisés près de l'oreille (plage de fréquence
de 300 MHz à 3 GHz)
Human exposure to radio frequency fields
from hand-held and body-mounted wireless
communication devices – Human models,
instrumentation, and procedures –
Part 1:
Procedure to determine the specific absorption
rate (SAR) for hand-held devices used in close
proximity to the ear (frequency range of
300 MHz to 3 GHz)
 IEC 2005 Droits de reproduction réservés  Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in any
utilisée sous quelque forme que ce soit et par aucun procédé, form or by any means, electronic or mechanical, including
électronique ou mécanique, y compris la photocopie et les photocopying and microfilm, without permission in writing from
microfilms, sans l'accord écrit de l'éditeur. the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale PRICE CODE XE
International Electrotechnical Commission
Международная Электротехническая Комиссия
Pour prix, voir catalogue en vigueur
For price, see current catalogue

– 2 – 62209-1  CEI:2005
SOMMAIRE
AVANT-PROPOS.8
INTRODUCTION.12
1 Domaine d’application .14
2 Références normatives .14
3 Termes et définitions .14
4 Symboles et abréviations.30
4.1 Grandeurs physiques.30
4.2 Constantes.32
4.3 Abréviations .32
5 Spécifications du système de mesure.32
5.1 Exigences générales .32
5.2 Spécification du fantôme (enveloppe et liquide).34
5.3 Spécification de l’équipement de mesure du DAS .44
5.4 Spécifications du système de balayage .44
5.5 Spécifications du support de l’appareil .44
5.6 Mesure des propriétés diélectriques du liquide .46
6 Protocole pour l’évaluation du DAS .46
6.1 Préparation des mesures .46
6.2 Essais à effectuer.58
6.3 Procédure de mesure .62
6.4 Traitement des mesures du DAS.64
7 Estimation des incertitudes .66
7.1 Considérations générales .66
7.2 Composantes contribuant à l’incertitude .68
7.3 Estimation de l’incertitude.92
8 Rapport de mesure .96
8.1 Généralité .96
8.2 Points à enregistrer dans le rapport .96

Annexe A (normative) Spécifications du fantôme .100
Annexe B (normative) Étalonnage de l'appareillage de mesure (linéarité, isotropie,
sensitivité) et évaluation de l'incertitude .112
Annexe C (normative) Techniques de post-traitement et d'évaluation de l'incertitude.142
Annexe D (normative) Validation du système de mesure du DAS .152
Annexe E (informative) Comparaisons entre laboratoires .166
Annexe F (informative) Définition du système de coordonnées d’un fantôme et d’un
système de coordonnées d’un appareil en essai (DUT).170
Annexe G (informative) Dipôles pour la validation.174
Annexe H (informative) Fantôme plan.178
Annexe I (informative) Formules recommandées pour les liquides équivalents aux
tissus des fantômes de la tête.182
Annexe J (informative) Mesures des propriétés diélectriques des liquides et estimation
des incertitudes .186

Bibliographie .206

62209-1  IEC:2005 – 3 –
CONTENTS
FOREWORD.9
INTRODUCTION.13
1 Scope .15
2 Normative references .15
3 Terms and definitions .15
4 Symbols and abbreviated terms .31
4.1 Physical quantities.31
4.2 Constants.33
4.3 Abbreviations .33
5 Measurement system specifications .33
5.1 General requirements .33
5.2 Phantom specifications (shell and liquid).35
5.3 Specifications of the SAR measurement equipment .45
5.4 Scanning system specifications.45
5.5 Device holder specifications.45
5.6 Measurement of liquid dielectric properties.47
6 Protocol for SAR assessment.47
6.1 Measurement preparation .47
6.2 Tests to be performed.59
6.3 Measurement procedure .63
6.4 Post-processing of SAR measurement data.65
7 Uncertainty estimation .67
7.1 General considerations .67
7.2 Components contributing to uncertainty.69
7.3 Uncertainty estimation .93
8 Measurement report .97
8.1 General .97
8.2 Items to be recorded in the test report.97

Annex A (normative) Phantom specifications .101
Annex B (normative) Calibration (linearity, isotropy, sensitivity) of the measurement
instrumentation and uncertainty estimation.113
Annex C (normative) Post-processing techniques and uncertainty estimation .143
Annex D (normative) SAR measurement system validation .153
Annex E (informative) Interlaboratory comparisons .167
Annex F (informative) Definition of a phantom coordinate system and a device under
test coordinate system .171
Annex G (informative) Validation dipoles .175
Annex H (informative) Flat phantom .179
Annex I (informative)  Recommended recipes for phantom head tissue-equivalent
liquids .183
Annex J (informative) Measurement of the dielectric properties of liquids and
uncertainty estimation.187

Bibliography .207

– 4 – 62209-1  CEI:2005
Figure 1 – Illustration du fantôme donnant les points de référence des oreilles RE et LE,
le point de référence de la bouche M, la ligne de référence N-F et la bande centrale……….36
Figure 2 – Bi-section sagittale du fantôme avec périmètre étendu (montrée en place
sur son côté comme lors des essais de DAS de appareil .36
Figure 3 – Section du SAM au plan de référence contenant B-M .40
Figure 4 – Vue de côté du fantôme montrant les marquages pertinents .42
Figure 5 – Lignes de référence verticale et horizontale et points de référence A, B
sur deux exemples types de combinés .52
Figure 6 – Position “joue” du dispositif sans fil sur le côté gauche du SAM.54
Figure 7 – Position «inclinée» de l’appareil sans fil sur le côté gauche du SAM .56
Figure 8 – Diagramme des essais à effectuer .60
Figure 9 – Orientation de la sonde par rapport à la ligne normale à la surface,
montrée en deux endroits différents .64
Figure 10 – Orientation et surface de volume d’intégration par rapport à la surface
du fantôme .92
Figure A.1 – Illustration des dimensions du Tableau A.1 .102
Figure A.2 – Vue de côté rapprochée du fantôme montrant la région de l’oreille .106
Figure A.3 – Vue de côté du fantôme montrant les marquages pertinents.108
Figure B.1 – Montage expérimental pour l'évaluation de la sensibilité (facteur de
conversion) utilisant un guide d'ondes rectangulaire vertical .120
Figure B.2 – Description du montage d’évaluation du gain de l’antenne .124
Figure B.3 – Montage utilisé pour déterminer l'écart de l'isotropie sphérique dans le
liquide simulant les tissus .130
Figure B.4 – Montage alternatif pour évaluer l’écart de l’isotropie sphérique de la
sonde dans le liquide équivalent aux tissus .132
Figure B.5 – Montage expérimental pour l’évaluation de l’isotropie hémisphèrique [11] .134
Figure B.6 – Conventions pour la position (ξ) du dipôle et la polarisation (θ ) [11] .134
Figure B.7 – Mesure de l’isotropie axiale avec l’antenne de référence.138
Figure B.8 – Mesure de l’isotropie hémisphérique avec la sonde de référence .138
Figure C.1 – Méthode des trois points .144
Figure C.2 – Méthode de la face tangentielle.144
Figure C.3 – Méthode d’intégration.146
Figure C.4 – Méthode d’intégration par extrusion.146
Figure C.5 – Extrapolation de données de DAS à la surface interne du fantôme basée sur

une courbe polynomiale des moindres carrés des données de mesure (points carrés).150
Figure D.1 – Montage pour le contrôle du système .156
Figure F.1 – Exemple de système de coordonnées de référence pour le fantôme SAM.170
Figure F.2 – Exemple de système de coordonnées pour un appareil en essai (DUT) .172
Figure G.1 – Détails mécaniques du dipôle de référence .176
Figure H.1 – Dimensions du montage du fantôme plan utilisé pour déduire les
dimensions minimales pour W et L .178
Figure H.2 – Incertitude prédite par l’utilisation d’un code FDTD, pour un DAS de crête
spatial 10 g moyen, fonction des dimensions du fantôme plan en comparaison avec un
fantôme plan infini .180
Figure J.1 – Montage du banc de mesure .188
Figure J.2 – Sonde coaxiale sans terminaison avec des rayons intérieur et extérieur
respectivement a et b .192
Figure J.3 – Montage pour l’essai diélectrique sur une ligne TEM [60] .196

62209-1  IEC:2005 – 5 –
Figure 1 – Picture of the phantom showing ear reference points RE and LE, mouth
reference point M, reference line N-F, and central strip.37
Figure 2 – Sagittally bisected phantom with extended perimeter (shown placed on its
side as used for device SAR tests).37
Figure 3 – Cross-sectional view of SAM at the reference plane containing B-M .41
Figure 4 – Side view of the phantom showing relevant markings .43
Figure 5 – Handset vertical and horizontal reference lines and reference points A, B on
two example device types .53
Figure 6 – Cheek position of the wireless device on the left side of SAM.55
Figure 7 – Tilt position of the wireless device on the left side of SAM .57
Figure 8 – Block diagram of the tests to be performed .61
Figure 9 – Orientation of the probe with respect to the line normal to the surface,
shown at two different locations .65
Figure 10 – Orientation and surface of the averaging volume relative to the phantom surface . 93
Figure A.1 – Illustration of dimensions in Table A.1 .103
Figure A.2 –Close up side view of phantom showing the ear region.107
Figure A.3 – Side view of the phantom showing relevant markings.109
Figure B.1 – Experimental set-up for assessment of the sensitivity (conversion factor)
using a vertically-oriented rectangular waveguide .121
Figure B.2 – Description of the antenna gain evaluation set-up .125
Figure B.3 – Set-up to assess spherical isotropy deviation in tissue-equivalent liquid .131
Figure B.4 – Alternative set-up to assess spherical isotropy deviation in tissue-
equivalent liquid.133
Figure B.5 – Experimental set-up for the hemispherical isotropy assessment [11] .135
Figure B.6 – Conventions for dipole position (ξ) and polarization (θ ) [11].135
Figure B.7 – Measurement of axial isotropy with a reference antenna .139
Figure B.8 – Measurement of hemispherical isotropy with reference antenna .139
Figure C.1 – Methods of three points.145
Figure C.2 – Method of the tangential face .145
Figure C.3 – Method of averaging .147
Figure C.4 – Extrude method of averaging.147
Figure C.5 – Extrapolation of SAR data to the inner surface of the phantom based on a
least-square polynomial fit of the measured data (squares).151
Figure D.1 – Set-up for the system check .157
Figure F.1 – Example reference coordinate system for the SAM phantom .171
Figure F.2 – Example coordinate system on the device under test .173
Figure G.1 – Mechanical details of the reference dipole .177
Figure H.1 – Dimensions of the flat phantom set-up used for deriving the minimal
dimensions for W and L .179
Figure H.2 – FDTD predicted uncertainty in the 10 g peak spatial-average SAR as a
function of the dimensions of the flat phantom compared with an infinite flat phantom .181
Figure J.1 – Slotted line set-up.189
Figure J.2 – An open-ended coaxial probe with inner and outer radii a and b,
respectively .193
Figure J.3 – TEM line dielectric test set-up [60] .197

– 6 – 62209-1  CEI:2005
Tableau 1 – Propriétés diélectriques du liquide équivalent aux tissus.42
Tableau 2 – Valeurs de référence DAS en watts par kilogrammes utilisées pour estimer
les incertitudes de post-traitement.86
Tableau 3 –Tableau pour l’évaluation de l’incertitude de mesure du DAS des combinés .94
Tableau A.1 – Dimensions de la tête pertinentes pour la forme du fantôme SAM:
dimensions comparées au 90e-percentile le plus grand de la tête masculine du rapport
de Gordon [18] .104
Tableau A.2 – Guides spécifiques à la conception du fantôme SAM et au fichier CAO.106
Tableau B.1 – Analyse de l’incertitude de l’étalonnage du transfert avec des sondes de
température.118
Tableau B.2 – Analyse de l'incertitude pour la technique utilisant la distribution
analytique de champ à l'intérieur de guides d'ondes .122
Tableau B.3 – Analyse de l'incertitude pour l'évaluation du gain des antennes de
référence.126
Tableau B.4 – Analyse de l'incertitude pour la technique utilisant des antennes de
référence.128
Tableau D.1 – Valeurs numériques du DAS de référence pour le dipôle de référence et
le fantôme plan.164
Tableau G.1 – Dimensions mécaniques des dipôles de référence .174
Tableau H.1 – Paramètres utilisés pour calculer les valeurs de DAS de référence du
Tableau D.1.180
Tableau I.1 – Formules suggérées pour obtenir les paramètres diélectriques cibles .184
Tableau J.1 – Paramètres pour le calcul des propriétés diélectriques de différents
liquides de référence .200
Tableau J.2 – Propriétés diélectriques de liquides de référence à 20 °C.202
Tableau J.3 – Exemple de fiche d’incertitudes et exemple de valeurs numériques pour
la mesure de la constante diélectrique (ε ′) et de la conductivité (σ).204
r
62209-1  IEC:2005 – 7 –
Table 1 – Dielectric properties of the tissue-equivalent liquid .43
Table 2 – Reference SAR values in watts per kilogram used for estimating post-
processing uncertainties .87
Table 3 – Measurement uncertainty evaluation template for handset SAR test .95
Table A.1 – Head dimensions relevant to phantom shape: SAM dimensions compared
to 90th-percentile large male head from Gordon report [18] .105
Table A.2 – Specific guidelines for the design of SAM phantom and CAD file .107
Table B.1 – Uncertainty analysis for transfer calibration using temperature probes.119
Table B.2 – Uncertainty template for calibration using analytical field distribution inside
waveguide .123
Table B.3 – Uncertainty template for evaluation of reference antenna gain.127
Table B.4 – Uncertainty template for calibration using reference antenna.129
Table D.1 – Numerical reference SAR values for reference dipole and flat phantom .165
Table G.1 – Mechanical dimensions of the reference dipoles .175
Table H.1 – Parameters used for calculation of reference SAR values in Table D.1 .181
Table I.1 – Suggested recipes for achieving target dielectric parameters.185
Table J.1 – Parameters for calculating the dielectric properties of various reference
liquids .201
o
Table J.2 – Dielectric properties of reference liquids at 20 C.203
Table J.3 – Example uncertainty template and example numerical values for dielectric
constant (ε ′) and conductivity (σ) measurement.205
r
– 8 – 62209-1  CEI:2005
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
EXPOSITION HUMAINE AUX CHAMPS RADIOFRÉQUENCE
PRODUITS PAR LES DISPOSITIFS DE COMMUNICATIONS
SANS FILS TENUS À LA MAIN OU PORTÉS PRÈS DU CORPS –
MODÈLES DE CORPS HUMAIN, INSTRUMENTATION
ET PROCÉDURES –
Partie 1: Détermination du débit d’absorption spécifique (DAS)
produit par les appareils tenus à la main et utilisés près de l’oreille
(plage de fréquence de 300 MHz à 3 GHz)

AVANT-PROPOS
1) La Commission Electrotechnique Internationale (CEI) est une organisation mondiale de normalisation
composée de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a
pour objet de favoriser la coopération internationale pour toutes les questions de normalisation dans les
domaines de l'électricité et de l'électronique. A cet effet, la CEI – entre autres activités – publie des Normes
internationales, des Spécifications techniques, des Rapports techniques, des Spécifications accessibles au
public (PAS) et des Guides (ci-après dénommés "Publication(s) de la CEI"). Leur élaboration est confiée à des
comités d'études, aux travaux desquels tout Comité national intéressé par le sujet traité peut participer. Les
organisations internationales, gouvernementales et non gouvernementales, en liaison avec la CEI, participent
également aux travaux. La CEI collabore étroitement avec l'Organisation Internationale de Normalisation (ISO),
selon des conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux de la CEI
intéressés sont représentés dans chaque comité d’études.
3) Les Publications de la CEI se présentent sous la forme de recommandations internationales et sont agréées
comme telles par les Comités nationaux de la CEI. Tous les efforts raisonnables sont entrepris afin que la CEI
s'assure de l'exactitude du contenu technique de ses publications; la CEI ne peut pas être tenue responsable
de l'éventuelle mauvaise utilisation ou interprétation qui en est faite par un quelconque utilisateur final.
4) Dans le but d'encourager l'uniformité internationale, les Comités nationaux de la CEI s'engagent, dans toute la
mesure possible, à appliquer de façon transparente les Publications de la CEI dans leurs publications
nationales et régionales. Toutes divergences entre toutes Publications de la CEI et toutes publications
nationales ou régionales correspondantes doivent être indiquées en termes clairs dans ces dernières.
5) La CEI n’a prévu aucune procédure de marquage valant indication d’approbation et n'engage pas sa
responsabilité pour les équipements déclarés conformes à une de ses Publications.
6) Tous les utilisateurs doivent s'assurer qu'ils sont en possession de la dernière édition de cette publication.
7) Aucune responsabilité ne doit être imputée à la CEI, à ses administrateurs, employés, auxiliaires ou
mandataires, y compris ses experts particuliers et les membres de ses comités d'études et des Comités
nationaux de la CEI, pour tout préjudice causé en cas de dommages corporels et matériels, ou de tout autre
dommage de quelque nature que ce soit, directe ou indirecte, ou pour supporter les coûts (y compris les frais
de justice) et les dépenses découlant de la publication ou de l'utilisation de cette Publication de la CEI ou de
toute autre Publication de la CEI, ou au crédit qui lui est accordé.
8) L'attention est attirée sur les références normatives citées dans cette publication. L'utilisation de publications
référencées est obligatoire pour une application correcte de la présente publication.
9) L’attention est attirée sur le fait que certains des éléments de la présente Publication de la CEI peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence.
La Norme Internationale CEI 62209-1 a été préparée par le Comité d'Études 106 de la CEI:
Méthodes d’évaluation des champs électriques, électriques et électromagnétiques en relation
avec l’exposition humaine.
Le texte de cette Norme est basé sur les documents suivants:
FDIS Rapport de vote
106/84/FDIS 106/88/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l’approbation de la présente Norme.

62209-1  IEC:2005 – 9 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
HUMAN EXPOSURE TO RADIO FREQUENCY FIELDS FROM HAND-HELD
AND BODY-MOUNTED WIRELESS COMMUNICATION DEVICES –
HUMAN MODELS, INSTRUMENTATION, AND PROCEDURES –

Part 1: Procedure to determine the specific absorption rate (SAR)
for hand-held devices used in close proximity to the ear
(frequency range of 300 MHz to 3 GHz)

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 62209-1 has been prepared by IEC technical committee 106:
Methods for the assessment of electric, magnetic and electromagnetic fields associated with
human exposure.
The text of this standard is based on the following documents:
FDIS Report on voting
106/84/FDIS 106/88/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.

– 10 – 62209-1  CEI:2005
Cette publication a été rédigée selon les Directives de la Partie 2 de l'ISO/CEI.
Le comité a décidé que le contenu de cette publication ne sera pas modifié avant la date de
maintenance indiquée sur le site web de la CEI sous «http://webstore.iec.ch» dans les
données relatives à la publication recherchée. A cette date, la publication sera
• reconduite;
• supprimée;
• remplacée par une édition révisée, ou
• amendée.
62209-1  IEC:2005 – 11 –
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
The committee has decided that the contents of this publication will remain unchanged until
the maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in
the data related to the specific publication. At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
– 12 – 62209-1  CEI:2005
INTRODUCTION
Les Comité d’Etudes CEI TC106, CENELEC TC106X WG1 et IEEE “Standard Coordinating
Committee 34 (SCC34), qui ont un certain nombre de membres communs, travaillent
ensemble de manière informelle pour atteindre l’objectif d’harmonisation, et spécialement au
sein de l’Equipe Projet 62209 du TC 106 CEI, dans le cadre de la préparation de la norme
“Exposition humaine aux champs radiofréquence produits par les dispositifs de commu-
nications sans fils tenus à la main ou portés près du corps“ et l’IEEE SCC34 pour la norme
IEEE 1528 “IEE Recommended Practice for Determining the Peak Spatial-Average Specific
Absorption Rate (SAR) in the Human Head from Wireless Communications Devices:
)
Measurements Techniques” [22] .
Pendant le processus d’élaboration de ces documents, un effort particulier a été fait pour
harmoniser ces deux normes.
———————
)
Les chiffres entre crochets renvoient à la bibliographie figurant à la fin de la présente norme.

62209-1  IEC:2005 – 13 –
INTRODUCTION
The international committees IEC TC 106, CENELEC Technical Committee TC 106x WG1,
and IEEE Standards Coordinating Committee 34 (SCC34) worked together informally through
common membership to achieve the goal of harmonization, specifically between IEC TC 106
Project Team 62209 for the document "Procedure to Measure the Specific Absorption Rate
(SAR) for Hand-Held Mobile Telephones in the Frequency Range of 300 MHz to 3 GHz" and
IEEE SCC34 for the IEEE Std 1528 "IEEE Recommended Practice for Determining the Peak
Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless
Communications Devices: Measurement Techniques" [22] .
During the process a primary effort involved was to harmonize these two standards

———————
1)
Numbers in square brackets refer to the bibliography.

– 14 – 62209-1  CEI:2005
EXPOSITION HUMAINE AUX CHAMPS RADIOFRÉQUENCE
PRODUITS PAR LES DISPOSITIFS DE COMMUNICATIONS
SANS FILS TENUS À LA MAIN OU PORTÉS PRÈS DU CORPS –
MODÈLES DE CORPS HUMAIN, INSTRUMENTATION
ET PROCÉDURES –
Partie 1: Détermination du débit d’absorption spécifique (DAS)
produit par les appareils tenus à la main et utilisés près de l’oreille
(plage de fréquence de 300 MHz à 3 GHz)

1 Domaine d’application
La présente Norme internationale s’applique aux appareils de communication tels que les
téléphones mobiles, les téléphones sans fil, etc., émettant des champs électromagnétiques
(EMF) et qui sont destinés à être utilisés tenus contre l’oreille, la partie rayonnante étant
proche de la tête. La gamme de fréquences s’étend de 300 MHz à 3 GHz.
L’objectif de cette norme est de spécifier la méthode de mesure permettant de démontrer la
conformité avec les limites de débit d’absorption spécifique (DAS) applicables à de tels
appareils.
2 Références normatives
Les documents de référence suivants sont indispensables pour l'application du présent
do
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...