oSIST prEN 17813:2022
(Main)Environmental matrices - Halogens and sulfur by oxidative pyrohydrolytic combustion followed by ion chromatography detection and complementary determination methods
Environmental matrices - Halogens and sulfur by oxidative pyrohydrolytic combustion followed by ion chromatography detection and complementary determination methods
This European Standard specifies a method for the direct determination total fluorine, chlorine, bromine and sulfur content in environmental solid matrices. The method is applicable for the determination of concentrations ≥ 10 mg/kg of each element based on dry matter. The upper limit and exact concentration range covered depends on system blank levels of instrumentation and capacity of the chromatographic separation column used for determination.
Umweltbezogene Charakterisierung fester Matrices - Halogene und Schwefel durch oxidative pyrohydrolytische Verbrennung, gefolgt von ionenchromatographischer Detektion und komplementären Bestimmungsmethoden
Dieses Dokument legt ein Verfahren für die gleichzeitige direkte Bestimmung des Gesamtgehalts an Fluor, Chlor, Brom und Schwefel in Feststoffen in der Umwelt fest. Das Verfahren gilt für die Bestimmung von Konzentrationen jedes Elements von ≥ 10 mg/kg, bezogen auf die Trockenmasse. Die Höchstgrenze und der exakte Konzentrationsbereich, der abgedeckt wird, hängen von den Blindwerten der Geräte und der Kapazität der für die Bestimmung verwendeten chromatographischen Trennsäule ab.
ANMERKUNG Die gleichzeitige Bestimmung des Gesamtjodgehalts ist möglich, aber derzeit nicht validiert.
Matrices environnementales - Méthode de dosage des halogènes et du soufre par combustion pyrohydrolytique oxidative suivie d’une détection par chromatographie ionique et méthodes de dosage complémentaires
Le présent document spécifie une méthode de dosage, directe et simultanée, du fluor total, chlore total, brome total et soufre total dans des matrices environnementales solides. Cette méthode s’applique à la détermination, pour chaque élément, de concentrations supérieures ou égales à 10 mg/kg, en masse de matière sèche. La limite supérieure et la plage de concentration exacte couverte dépendent des niveaux de blanc des appareils et de la capacité de la colonne de séparation chromatographique utilisée pour le dosage.
NOTE Le dosage simultané de l’iode total est possible, mais non validé à l’heure actuelle.
Matriksi z vidika okolja - Določevanje halogenov in žvepla z ionsko kromatografijo in primerljivimi (komplementarnimi) metodami po oksidativnem pirohidrolitskem sežigu
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
oSIST prEN 17813:2022
01-januar-2022
Matriksi z vidika okolja - Določevanje halogenov in žvepla z ionsko kromatografijo
ali komplementarnimi/dopolnilnimi metodami po pirohidrolitskem sežiguEnvironmental matrices - Halogens and sulfur by oxidative pyrohydrolytic combustion
followed by ion chromatography detection and complementary determination methodsUmweltbezogene Charakterisierung fester Matrices - Halogene und Schwefel durch
oxidative pyrohydrolytische Verbrennung, gefolgt von ionenchromatographischer
Detektion und komplementären Bestimmungsmethoden
Ta slovenski standard je istoveten z: prEN 17813
ICS:
71.040.40 Kemijska analiza Chemical analysis
71.040.50 Fizikalnokemijske analitske Physicochemical methods of
metode analysis
oSIST prEN 17813:2022 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------oSIST prEN 17813:2022
---------------------- Page: 2 ----------------------
oSIST prEN 17813:2022
DRAFT
EUROPEAN STANDARD
prEN 17813
NORME EUROPÉENNE
EUROPÄISCHE NORM
January 2022
ICS 71.040.40; 71.040.50
English Version
Environmental matrices - Halogens and sulfur by oxidative
pyrohydrolytic combustion followed by ion
chromatography detection and complementary
determination methods
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 444.If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2022 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 17813:2022 E
worldwide for CEN national Members.---------------------- Page: 3 ----------------------
oSIST prEN 17813:2022
prEN 17813:2022 (E)
Contents Page
European foreword ............................................................................................................................................ 4
1 Scope .......................................................................................................................................................... 5
2 Normative references .......................................................................................................................... 5
3 Terms and definitions ......................................................................................................................... 5
4 Principle ................................................................................................................................................... 5
5 Interferences .......................................................................................................................................... 5
5.1 Interferences during combustion ................................................................................................... 5
5.2 Interferences during absorption ..................................................................................................... 6
5.3 Interferences during ion chromatography .................................................................................. 6
6 Reagents and gases............................................................................................................................... 6
6.1 General...................................................................................................................................................... 6
6.2 Reagents for ion chromatography .................................................................................................. 6
6.2.1 Eluents ...................................................................................................................................................... 6
6.2.2 Water, with a resistivity of ≥ 18 MΩ cm (25°C). ......................................................................... 6
6.2.3 Sodium carbonate (anhydrous), Na CO ...................................................................................... 6
2 36.2.4 Bromide, chloride, fluoride, and sulfate stock solutions, c = 1 000 mg/l of each
element ..................................................................................................................................................... 6
6.2.5 Bromide, chloride, fluoride and sulfate standard solutions ................................................. 7
6.3 Reagents and gases for combustion ............................................................................................... 7
6.3.1 Inert gas, for example Argon, ≥ 99,9 % purity............................................................................ 7
6.3.2 Oxygen, ≥ 99,9 % purity..................................................................................................................... 7
6.3.3 Control standard ................................................................................................................................... 8
6.4 Reagents for absorption ..................................................................................................................... 8
6.4.1 General...................................................................................................................................................... 8
6.4.2 Hydrogen peroxide solution, H O , approx. 30 %, electronic grade ................................. 8
2 26.4.3 Sodium methane sulfonate, CH SO Na ......................................................................................... 9
3 37 Apparatus ................................................................................................................................................ 9
7.1 Combustion apparatus ........................................................................................................................ 9
7.1.1 Combustion furnace ............................................................................................................................. 9
7.1.2 Combustion vessel .............................................................................................................................. 10
7.1.3 Absorption vessel ............................................................................................................................... 10
7.2 Ion Chromatography (IC) system .................................................................................................. 10
7.2.2 HPLC pump ............................................................................................................................................ 10
7.2.3 Sample injection system ................................................................................................................... 10
7.2.4 Separation column ............................................................................................................................. 10
7.2.5 Conductivity detector and suppressor device .......................................................................... 11
7.2.6 Guard column ....................................................................................................................................... 11
7.2.7 data handling unit............................................................................................................................... 11
7.2.8 Quality of the separation system ................................................................................................... 11
8 Sampling and sample preparation ............................................................................................... 12
9 Procedure .............................................................................................................................................. 12
9.1 Combustion ........................................................................................................................................... 12
---------------------- Page: 4 ----------------------oSIST prEN 17813:2022
prEN 17813:2022 (E)
9.1.1 General ................................................................................................................................................... 12
9.1.2 Blank determination ......................................................................................................................... 12
9.2 Absorption ............................................................................................................................................ 12
9.3 Ion chromatography .......................................................................................................................... 13
9.3.1 General ................................................................................................................................................... 13
9.3.2 Calibration............................................................................................................................................. 13
9.3.3 Measurement ....................................................................................................................................... 13
9.4 Initial and daily checks ..................................................................................................................... 13
9.4.1 Initial laboratory capability check ............................................................................................... 13
9.4.2 Daily check ............................................................................................................................................ 14
10 Calculation ............................................................................................................................................ 14
11 Expression of result ........................................................................................................................... 14
12 Reporting ............................................................................................................................................... 15
Bibliography ....................................................................................................................................................... 16
---------------------- Page: 5 ----------------------oSIST prEN 17813:2022
prEN 17813:2022 (E)
European foreword
This document (prEN 17813:2022) has been prepared by Technical Committee CEN/TC 444
“Environmental characterization of solid matrices”, the secretariat of which is held by NEN.
This document is currently submitted to the CEN Enquiry.---------------------- Page: 6 ----------------------
oSIST prEN 17813:2022
prEN 17813:2022 (E)
1 Scope
This document specifies a method for the simultaneous direct determination of the total fluorine,
chlorine, bromine and sulfur content in environmental solid matrices. The method is applicable for the
determination of concentrations ≥ 10 mg/kg of each element based on dry matter. The upper limit and
exact concentration range covered depend on system blank levels of instrumentation and capacity of the
chromatographic separation column used for determination.NOTE Simultaneous determination of total iodine content is possible but currently not validated.
2 Normative referencesThere are no normative references in this document.
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
• IEC Electropedia: available at https://www.electropedia.org/• ISO Online browsing platform: available at https://www.iso.org/obp
3.1
pyrohydrolysis
high temperature chemical reaction with water
4 Principle
The homogenized sample is combusted under oxidative conditions. For the determination of total
fluorine the combustion is performed under pyrohydrolytic conditions. The combustion gases are
absorbed in an aqueous solution. For the determination of total sulfur the absorption solution contains
an additive to ensure complete conversion to sulfate. Changes in the volume of the absorption solution
are considered for concentration calculations.The anions of interest (bromide, chloride, fluoride, sulfate) are separated by liquid chromatography,
applying an anion exchange resin as stationary phase, and aqueous solutions of salts of weak mono- and
dibasic acids as eluents for isocratic or gradient elution. Detection is carried out using a conductivity
detector (CD). When using a CD the eluents shall show a sufficiently low conductivity. For this reason, a
CD is usually combined with a suppressor device (cation exchanger), which will reduce the conductivity
of the eluent and transform the sample species into their respective acids.NOTE A UV detector is not required to carry out this analysis, but can be used for the detection of bromide, if a
higher detection selectivity is required or in case of a matrix interference observed in conductivity detection.
Bromide can be detected directly at λ = 205 nm.5 Interferences
5.1 Interferences during combustion
Missing or too low water supply to establish pyrohydrolytic conditions during total fluorine
determination can lead to negative bias. Sulfur present as inorganic compounds with high melting points
(e.g. earth alkali metal sulfates) can lead to negative bias if combustion temperatures are too low.
---------------------- Page: 7 ----------------------oSIST prEN 17813:2022
prEN 17813:2022 (E)
5.2 Interferences during absorption
Missing or too low amount of oxidizing agent in the absorption solution can lead to negative bias on the
determination of total sulfur. Missing or too low amount of reducing agent in the absorption solution can
lead to an underestimation of total bromine, as elemental bromine can be formed during combustion.
5.3 Interferences during ion chromatographyAny substance that has a retention time similar to that of the analyte ion and generates a detector signal
can cause interference. A high concentration of ions can influence peak resolution and retention time of
the analyte. A gradient elution can help to prevent many such interferences.6 Reagents and gases
6.1 General
Use only reagents of recognized analytical grade. The purity of water, reagents and gases shall be
confirmed. Unless otherwise specified, reagents shall be weighed to an accuracy of ± 1 % of nominal
mass. Commercially available solutions may be used. If necessary, alternative volumes and
concentrations may be prepared for the solutions described in this section.Relevant reagents should be tested for their contribution to the blank value.
6.2 Reagents for ion chromatography
6.2.1 Eluents
Degas all water used for eluent preparation. During operation, gas intake shall be prevented, e.g. by
applying inert gas to the eluent bottles or use of an inline degasser.Carbonate, hydrogen carbonate, or hydroxide salts may be used to prepare eluents. Eluents can be
prepared manually, by low pressure mixing from stock solutions or electrochemically in situ. The choice
of eluent depends on the column chosen and the detector. Follow instructions of the column
manufacturer. The selected combination of separation column and eluent shall fulfil the requirement for
resolution according to 7.2.8. The eluents may be used as long as the requirements of 7.2.8 are met. An
example of a suitable eluent is described in 6.2.3.2.6.2.2 Water, with a resistivity of ≥ 18 MΩ cm (25°C).
6.2.3 Sodium carbonate (anhydrous), Na CO
2 3
6.2.3.1 Sodium carbonate concentrate, c(Na CO ) = 0,09 mol/l
2 3
Dissolve 9,54 g anhydrous sodium carbonate (6.2.3) in water in a 1 000 ml volumetric flask and bring to
volume with water.The solution is stable for six months if stored at 2 °C to 8 °C
6.2.3.2 Sodium carbonate eluent, c(Na CO ) = 0,009 mol/l
2 3
Pipette 100 ml of sodium carbonate concentrate (6.2.3.1) into a 1 000 ml volumetric flask and bring to
volume with water.6.2.4 Bromide, chloride, fluoride, and sulfate stock solutions, c = 1 000 mg/l of each element
Single anion and mixed anion stock solutions are commercially available in sufficiently high quality.
These solutions are considered stable for several months. Alternatively, stock solutions may be prepared
manually according to Table 1.---------------------- Page: 8 ----------------------
oSIST prEN 17813:2022
prEN 17813:2022 (E)
Salts are dried appropriately and dissolved according to the weights stated in the table. For calibration,
use mixed multi component standard solutions with at least five different concentrations.
Table 1 — Weighing and salt pretreatment for stock solutionsAnion Salt Weighing (g) Dry salt at (105 ± 5) °C
for at least
Fluoride NaF 2,210 1 h
Chloride NaCl 1,648 2 h
Bromide NaBr 1,288 6 h
Sulfate Na SO 4,439 3 h
2 4
Other salts with corresponding weights and pretreatment specifications may be used.
6.2.5 Bromide, chloride, fluoride and sulfate standard solutions6.2.5.1 General
Depending on the concentrations expected, prepare single or mixed calibration solutions with different
bromide, chloride, fluoride, and sulfate concentrations from the stock standard solution (6.2.4). The
example in 6.2.5.3 describes preparation...


Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.