SIST EN 60728-7-2:2006
(Main)Cable networks for television signals, sound signals and interactive services -- Part 7-2: Hybrid Fibre Coax Outside Plant Status Monitoring - Media access Control (MAC) Layer Specification
Cable networks for television signals, sound signals and interactive services -- Part 7-2: Hybrid Fibre Coax Outside Plant Status Monitoring - Media access Control (MAC) Layer Specification
Specifies requirements for The Hybrid Fibre Coax (HFC) Outside Plant (OSP) Media Access Control (MAC) Layer. This standard is part of the series developed to support the design and implementation of interoperable management systems for evolving HFC cable networks. The HMS Media Access Control (MAC) layer specification describes the messaging and protocols implemented at the Data Link Layer (DLL), layer 2 in the 7 layer ISO-OSI reference model, that support reliable and efficient communications between HMS compliant transponders interfacing to managed OSP network elements (NEs) and a centralized head-end element (HE).
Kabelnetze für Fernsehsignale, Tonsignale und interaktive Dienste -- Teil 7-2: Zustandsüberwachung Hybrid-Faser-Koax-Netze (HFC) - Festlegung Steuerungsschicht für Mediumzugriff (MAC)
Réseaux de distribution par câbles pour signaux de télévision, signaux de radiodiffusion sonore et services interactifs -- Partie 7-2: Surveillance de l'état des installations extérieures des réseaux hybrides à fibre optique et câble coaxial - Spécification de la couche du contrôle d'accès au support
Specifies requirements for The Hybrid Fibre Coax (HFC) Outside Plant (OSP) Media Access Control (MAC) Layer. This standard is part of the series developed to support the design and implementation of interoperable management systems for evolving HFC cable networks. The HMS Media Access Control (MAC) layer specification describes the messaging and protocols implemented at the Data Link Layer (DLL), layer 2 in the 7 layer ISO-OSI reference model, that support reliable and efficient communications between HMS compliant transponders interfacing to managed OSP network elements (NEs) and a centralized head-end element (HE).
Kabelska omrežja za televizijske in zvokovne signale ter interaktivne storitve – 7-2. del: Nadzorovanje stanja zunanjih inštalacij omrežij hibridnih optično-koaksialnih kablov – Specifikacija plasti za dostop do medijev (MAC) (IEC 60728-7-2:2003)
General Information
- Status
- Published
- Publication Date
- 31-Dec-2005
- Technical Committee
- AVM - Audio, video and multimedia systems and equipment
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-Jan-2006
- Due Date
- 01-Jan-2006
- Completion Date
- 01-Jan-2006
Overview
EN 60728-7-2:2005 (adopted from IEC 60728-7-2:2003) specifies the Media Access Control (MAC) layer requirements for status monitoring of Hybrid Fibre Coax (HFC) Outside Plant (OSP). Part of the EN 60728 series for cable networks, this standard defines messaging and data-link layer protocols that enable reliable communications between HMS-compliant transponders, managed OSP network elements (NEs) and a centralized head-end (HE). It supports interoperable management systems for evolving HFC cable networks used for television, audio and interactive services.
Key Topics
- Scope and Purpose: Defines MAC-layer behaviour for OSP status monitoring within HFC networks to support interoperable management and monitoring.
- Data Link Layer (Layer 2): Describes messaging formats, frame handling and protocol interactions at the ISO-OSI layer 2 for HMS (Head-end Management System) communications.
- HMS Interoperability: Requirements to ensure reliable communication between transponders, network elements and head-end systems for status and fault reporting.
- Protocol Reliability: Elements that support robust, efficient transfer of status and control messages across the HFC outside plant.
- Standardization Context: Aligned with IEC 60728-7-2:2003 and incorporated into the CENELEC/CLC portfolio for national adoption.
Applications
- Network monitoring and OSP status reporting in HFC cable networks
- Designing and implementing HMS-compliant transponders and head-end elements
- Integrating OSP fault detection and telemetry with Network Management Systems (NMS)
- Enabling remote diagnostics, preventive maintenance and condition monitoring of outside plant components
- Ensuring multi-vendor interoperability across HFC deployments for cable operators
Who Should Use This Standard
- Cable network operators and service providers managing HFC Outside Plant
- Equipment manufacturers designing MAC-layer firmware for transponders and network elements
- System integrators and software developers building head-end management and OSS/NMS solutions
- Standards bodies and test labs validating compliance and interoperability
Related Standards
- IEC 60728-7-2:2003 (original international text)
- Other parts of the EN 60728 series covering cable networks, system interfaces and network management (refer to national CENELEC/CLC publications for exact cross-references)
Keywords: EN 60728-7-2, HFC Outside Plant, MAC Layer Specification, Hybrid Fibre Coax, HMS, Data Link Layer, OSP status monitoring, head-end, transponder, cable network management.
Frequently Asked Questions
SIST EN 60728-7-2:2006 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Cable networks for television signals, sound signals and interactive services -- Part 7-2: Hybrid Fibre Coax Outside Plant Status Monitoring - Media access Control (MAC) Layer Specification". This standard covers: Specifies requirements for The Hybrid Fibre Coax (HFC) Outside Plant (OSP) Media Access Control (MAC) Layer. This standard is part of the series developed to support the design and implementation of interoperable management systems for evolving HFC cable networks. The HMS Media Access Control (MAC) layer specification describes the messaging and protocols implemented at the Data Link Layer (DLL), layer 2 in the 7 layer ISO-OSI reference model, that support reliable and efficient communications between HMS compliant transponders interfacing to managed OSP network elements (NEs) and a centralized head-end element (HE).
Specifies requirements for The Hybrid Fibre Coax (HFC) Outside Plant (OSP) Media Access Control (MAC) Layer. This standard is part of the series developed to support the design and implementation of interoperable management systems for evolving HFC cable networks. The HMS Media Access Control (MAC) layer specification describes the messaging and protocols implemented at the Data Link Layer (DLL), layer 2 in the 7 layer ISO-OSI reference model, that support reliable and efficient communications between HMS compliant transponders interfacing to managed OSP network elements (NEs) and a centralized head-end element (HE).
SIST EN 60728-7-2:2006 is classified under the following ICS (International Classification for Standards) categories: 33.060.40 - Cabled distribution systems; 35.100.60 - Presentation layer. The ICS classification helps identify the subject area and facilitates finding related standards.
You can purchase SIST EN 60728-7-2:2006 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of SIST standards.
Standards Content (Sample)
SLOVENSKI SIST EN 60728-7-2:2006
STANDARD
januar 2006
Kabelska omrežja za televizijske in zvokovne signale ter interaktivne storitve –
7-2. del: Nadzorovanje stanja zunanjih inštalacij omrežij hibridnih optično-
koaksialnih kablov – Specifikacija plasti za dostop do medijev (MAC) (IEC
60728-7-2:2003)
(istoveten EN 60728-7-2:2005)
Cable networks for television signals, sound signals and interactive services – Part
7-2: Hybrid Fibre Coax Outside Plant Status Monitoring – Media access Control
(MAC) Layer Specification (IEC 60728-7-2:2003)
ICS 33.060.40; 35.100.60 Referenčna številka
© Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljeno
EUROPEAN STANDARD EN 60728-7-2
NORME EUROPÉENNE
EUROPÄISCHE NORM February 2005
ICS 35.100.60; 33.160; 33.040
English version
Cable networks for television signals,
sound signals and interactive services
Part 7-2: Hybrid Fibre Coax Outside Plant Status Monitoring –
Media access Control (MAC) Layer Specification
(IEC 60728-7-2:2003)
Réseaux de distribution par câbles Kabelnetze für Fernsehsignale,
pour signaux de télévision, signaux Tonsignale und interaktive Dienste
de radiodiffusion sonore et services Teil 7-2: Zustandsüberwachung Hybrid-
interactifs Faser-Koax-Netze (HFC) –
Partie 7-2: Surveillance de l'état Festlegung Steuerungsschicht
des installations extérieures des réseaux für Mediumzugriff (MAC)
hybrides à fibre optique et câble coaxial - (IEC 60728-7-2:2003)
Spécification de la couche du contrôle
d'accès au support
(CEI 60728-7-2:2003)
This European Standard was approved by CENELEC on 2004-12-01. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards
...










Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...