This European Standard specifies requirements and test methods for the safety in use of power operated door, gate and barrier, intended for installation in areas in the reach of persons, and for which the main intended use is  giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises.
This European Standard also covers power operated vertically moving commercial doors such as rolling shutters and rolling grilles, used in retail premises which are mainly provided for goods protection.
This European Standard deals with all significant hazards, hazardous situations and events relevant to the power operation of industrial, commercial and garage doors, and gates when they are used as intended and under conditions of misuse which are reasonably foreseeable as identified in Clause 4.
All lifetime phases of the machinery including transportation, assembly, dismantling, disabling and scrapping are considered by this standard.
This European Standard does not apply to
-   lock gates and dock gates;
-   doors on lifts;
-   doors on vehicles;
-   armoured doors;
-   doors mainly for the retention of animals, unless they are at the site perimeter ;
-   theatre textile curtains;
-   horizontally moving power operated doors mainly intended for pedestrian use;
-   doors outside the reach of people (such as crane gantry fences);
-   railway barriers;
-   barriers intended solely for use by pedestrians;
-   barriers used solely for vehicles on motorways.
Whenever the term "door" is used in this document, it shall be deemed to cover the full scope of types and variances of doors, gates and barriers in the scope of this Standard.
This European Standard does not deal with any specific requirements on noise emitted from power operated door, gate and barrier, intended for installation in areas in the reach of persons, and for which the main intended use is giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises as their noise emission is not considered to be a relevant hazard.
NOTE   Noise emission of power operated doors is not a significant hazard for the users of these products. It is a comfort aspect.
This European Standard is not applicable to machinery which are manufactured before the date of publication of the standard.

  • Standard
    68 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies mechanical requirements and test methods for manually operated doors, gates and barriers, intended for installation in areas in the reach of persons, and for which the main intended use is giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises.
This European Standard also covers manually operated vertically moving commercial doors such as rolling shutters and rolling grilles, used in retail premises which are mainly provided for goods protection.
This document applies only to doors which are not part of the load carrying structure of the building.
It does not apply to:
—   lock gates and dock gates;
—   doors on vehicles;
—   doors mainly for the retention of animals unless they are at the site perimeter;
—   doors intended for pedestrian use;
—   railway barriers.
Whenever the term “door” is used in this document, it is deemed to cover the full scope of types and variances of doors, gates and barriers defined by the scope of this European Standard.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   General
This European Standard specifies the safety and performance requirements, except resistance to fire and smoke control characteristics, for industrial, commercial, garage doors and gates and barriers, intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises.
Fire resisting and/or smoke control characteristics for industrial, commercial, garage doors and gates are covered by EN 16034.
This European Standard also covers commercial doors such as rolling shutters and rolling grilles used in retail premises which are mainly provided for the access of persons rather than vehicles or goods.
These doors can include pass doors incorporated in the door leaf which are also covered by this European Standard.
These devices can be manually or power operated.
This European Standard does not cover operation in environments where the electromagnetic disturbances are outside the range of those specified in EN 61000 6 3.
1.2   Exclusions
This European Standard does not apply to the following which are intended for a different use:
-   lock gates and dock gates;
-   doors on lifts;
-   doors on vehicles;
-   armoured doors;
-   doors mainly for the retention of animals;
-   theatre textile curtains;
-   horizontally moving power operated doors mainly intended for pedestrian use in accordance with EN 16361;
-   revolving doors of any size;
-   railway barriers;
-   barriers used solely for vehicles.
This European Standard does not cover the radio part of doors. If a radio operating device is used, the relevant ETSI standards should be applied in addition.
This European Standard does not contain any specific requirement for doors which are moving because of energy stored by dedicated means from human power such as manually tensioned springs.
This European Standard does not contain any specific requirements for doors on escape routes. The ability to open the door leaf safely and easily cannot normally be achieved by industrial, commercial and garage doors due to size, weight and/or mode of operation.
The noise emission of powered doors and gates is not considered to be a relevant hazard. Therefore this European Standard does not contain any specific requirements on noise in relation to the Machinery Directive.
1.3   Specific applications
This European Standard should also apply to power operated doors which have been created by the addition of power operation to an installed manual door in respect of the relevant requirements. Annex ZA does not apply to this kind of door.
It also identifies requirements and classes of performance for additional characteristics considered to be of importance to the trade.
When a door is part of the load carrying structure of the building the requirements of this European Standard can apply on a voluntary basis in addition to the requirements for the load carrying structure, which are not dealt with in this European Standard. Annex ZA does not apply for this kind of doors.

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    30 pages
    German language
    sale 10% off
    e-Library read for
    1 day

This Technical Report gives simplified calculation relating to the energy losses through doors taking into account:
-   heat transmission with closed door by temperature difference,
-   air leakage through a closed door due to wind,
-   air leakage through a closed door due to a chimney effect, and
-   air infiltration with a door open (due to wind).

  • Technical report
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Technical report
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   General
This European Standard specifies a method for calculating the thermal transmittance of industrial, commercial and garage doors in a closed position.
The doors are intended for installation in areas in the reach of people, for which the main intended uses are giving safe access for goods, vehicles and persons in industrial, commercial or residential premises.
The doors may be manually or power operated.
This document applies to all doors provided in accordance with EN 13241-1.
The calculation can include different types of glazing, frames with or without thermal breaks, and different types of opaque panels and thermal bridge effects at the edge of the panel or joint between the glazed area, the frame area and the panel area.
This paper does not include the effects of solar radiation, heat transfer caused by air leakage, calculation of condensation, additional heat transfer at the corners and edges of the door connections to the main building structure, or thermal effects between the door and the main building structure.
1.2   Exclusions
It does not apply to:
-   lock gates and dock gates;
-   doors on lifts;
-   doors on vehicles;
-   armoured doors;
-   doors mainly for the retention of animals;
-   theatre textile curtains;
-   horizontally moving doors less than 2,5 m wide and 6,25 m2 area, designed principally for pedestrian use;
-   revolving doors of any size;
-   doors outside the reach of people (such as crane gantry fences);
-   railway barriers;
-   barriers used solely for vehicles.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   General
This European Standard applies for design, construction and testing of sensitive protective devices where the device is used to detect pedestrians including in particular applications, slow moving elderly persons, slow moving disabled persons and children who may be exposed to injury by power operated doors, gates and barriers, electrically powered from a public supply and intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial, public or residential premises.
This standard also covers safety devices for commercial doors such as rolling shutters and rolling grilles when used as doors on retail premises which are mainly provided for the access of persons rather than vehicles or goods.
This standard deals with all significant hazards listed in annex A and specifies requirements to eliminate or minimise them.
This standard covers the requirements for electrical powered safety devices using mains supply provided for installation on or used in conjunction with powered doors in order to avoid hazardous situations which can be encountered when a door is used normally.
The sensitive protective device is designed to give a change in the output signal switching device which may be used to provide protection for the person being at risk. It applies to ready to use sensitive protective device and integrated sensitive protective device (mounted on or connected to a power operated door in normal use).
This standard only applies to door safety devices manufactured after the date of publication.
1.2   Exclusions
This European Standard does not apply to protective equipment for installation on doors which are intended for a different use than the one described above such as:
-   lock gates and dock gates;
-   doors on lifts;
-   doors on vehicles;
-   doors mainly for the retention of animals;
-   theatre textile curtains;

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    33 pages
    German language
    sale 10% off
    e-Library read for
    1 day

1.1 General This European Standard specifies the test method and / or calculation of resistance to wind load for doors in a closed position. The doors are intended for installation in areas in the reach of people, for which the main in-tended uses are giving safe access for goods, vehicles and persons in industrial, commercial or residential premises. The doors may be manually or power operated. This document applies to all doors provided in accordance with prEN 13 241:1998. 1.2 Exclusions It does not apply to: - lock gates and dock gates; - doors on lifts; - doors on vehicles; - armoured doors; - door mainly for the retention of animals; - theatre textile curtains;    
- horizontally moving doors less than 2,5 m wide and 6,25 m ² area, designed principally for pedestrian use; - revolving doors of any size;
- doors outside the reach of people (such as crane gantry fences); - railway barriers; - barriers used solely for vehicles.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    14 pages
    German language
    sale 10% off
    e-Library read for
    1 day

1.1 General This European Standard specifies the classification for resistance to water penetration for doors in a closed position, when tested in accordance with EN 12489. The doors are intended for installation in areas in the reach of people, for which the main in-tended
uses are giving safe access for goods, vehicles and persons in industrial, commercial or residential premises. The doors may be manually or power operated. This document applies to all doors provided in accordance with prEN 13241:1998. 1.2 Exclusions It does not apply to: - lock gates and dock gates; - doors on lifts; - doors on vehicles; - armoured doors; - doors mainly for the retention of animals; - theatre textile curtains; - horizontally moving doors less than 2,5 m wide and 6,25 m² area, designed principally for pedestrian use; - revolving doors of any size; - doors outside the reach of people (such as crane gantry fences); - railway barriers; - barriers used solely for vehicles.

  • Standard
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1 General This European Standard specifies a test method for determining the air permeability for doors in a closed position. The doors are intended for installation in areas in the reach of people, for which the main in-tended uses are giving safe access for goods, vehicles and persons in industrial, commercial or residential premises. The doors may be manually or power operated. This document applies to all doors provided in accordance with prEN 13 241:1998. 1.2 Exclusions It does not apply to: - lock gates and dock gates; - doors on lifts;
- doors on vehicles; - armoured doors; - doors mainly for the retention of animals; - theatre textile curtains; - horizontally moving doors less than 2,5 m wide and 6,25 m² area, designed principally for pedestrian use; - revolving doors of any size; - doors outside the reach of  people (such as crane gantry fences); - railway barriers; - barriers used solely for vehicles.

  • Standard
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1 General This European Standard specifies the test method for determining the resistance to water penetration for doors in a closed position. The doors are intended for installation in areas in the reach of people, for which the main intended uses are giving safe access for goods, vehicles and persons in industrial, commer-cial or residential premises. The doors may be manually or power operated. This document applies to all doors provided in accordance with prEN 13 241:1998. 1.2 Exclusions It does not apply to: - lock gates and dock gates; - doors on lifts; - doors on vehicles; - armoured doors; - doors mainly for the retention of animals; - theatre textile curtains; - horizontally moving doors less than 2,5 m wide and 6,25 m² area, designed principally for pedestrian use; - revolving doors of any size;
- doors outside the reach of people (such as crane gantry fences); - railway barriers; - barriers used solely for vehicles.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1 General This European Standard specifies the classification for wind load for doors in a closed posi-tion. The doors are intended for installation in areas in the reach of people, for which the main intended uses are giving safe access for goods, vehicles and persons in industrial, commer-cial or residential premises.The doors may be manually or power operated. NOTE In case of wind load it is not necessary that the door can be opened or closed. This document applies to all doors provided in accordance with prEN 13241:1998. 1.2 Exclusions It does not apply to: - lock gates and dock gates; - doors on lifts; - doors on vehicles; - armoured doors; - doors mainly for the retention of animals; - theatre textile curtains; - horizontally moving doors less than 2,5 m wide and 6,25 m² area, designed principally for
pedestrian use; - revolving doors of any size; - doors outside the reach of people (such as crane gantry fences); - railway barriers; - barriers used solely for vehicles.

  • Standard
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    4 pages
    German language
    sale 10% off
    e-Library read for
    1 day

1.1 General This European Standard specifies the classification for air permeability for doors in a closed position, when tested in accordance with EN 12427. The doors are intended for installation in areas in the reach of people, for which the main in-tended uses are giving safe access for goods, vehicles and persons in industrial, commercial or residential premises. The doors may be manually or power operated. This document applies to all doors provided in accordance with prEN 13241:1998. 1.2 Exclusions It does not apply to: - lock gates and dock gates; - doors on lifts; - doors on vehicles; - armoured doors; - doors mainly for the retention of animals; - theatre textile curtains; - horizontally moving doors less than 2,5 m wide and 6,25 m² area, designed principally for pedestrian use; - revolving doors of any size; - doors outside the reach of people (such as crane gantry fences); - railway barriers; - barriers used solely for vehicles.

  • Standard
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the terminology for doors, gates and barriers, intended for installation in areas in the reach of people, for which the main intended uses are giving safe access for goods and vehicles accompanied by persons in industrial and commercial premises and in residential garages. This standard specifies with the help of sketches most types of doors, gates and barriers in common use, irrespective of the material used. Doors for the passage of persons only are covered by prEN 12650-1 and prEN 12519.

  • Standard
    13 pages
    English, French and German language
    sale 10% off
    e-Library read for
    1 day

This standard specifies the terms for parts of most types of doors, gates and barriers in common use. The terms used are therefore also applicable for barriers.

  • Standard
    13 pages
    English or French or German language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements and test methods for sensitive protective equipment put separately on the market as safety components to be used with entrance equipment such as power operated industrial, commercial and garage doors, gates and barriers, power operated pedestrian doors and power operated pedestrian entrance control equipment.
NOTE   Requirements for the safe function of the combination of protective device and industrial, commercial and garage doors and barriers are given in EN 12453.
This document deals with all significant hazards, hazardous situations and events relevant to the power operation of doors, and gates and barriers when they are used as intended and under conditions of misuse which are reasonably foreseeable as identified in Clause 4.
All lifetime phases of the sensitive protective equipment including transportation, assembly, dismantling, disabling and scrapping are considered by this document.
Whenever the term „door” is used in this document, it is deemed to cover the full scope of types and variances of doors, gates and barriers and entrance control equipment listed in the scope of EN 12453:2017+A1:2021, EN 16005:2012 and EN 17352:2022.
This document is not intended to be used for sensitive protective equipment using ultrasonic, radar, capacitive, inductive, and passive infrared and vision based technologies. For these types of equipment this document can be used as a guide to demonstrate that such a device is allowed.
This document is not applicable to sensitive protective equipment manufactured before the date of its publication.

  • Draft
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the performance requirements for doors, gates and barriers, intended for installation in areas in the reach of people, for which the main intended uses are giving safe access for goods and vehicles accompagnied by persons in industrial and commercial premises and in residential garages. The devices may be manually or power operated. Note: Power operated doors may be supplied either as an original power operated door or by the retrospective addition of a drive unit to a previously manually operated door.

  • Draft
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a test method for determining the air permeability for industrial, commercial and garage doors and gates according prEN 13241:2020 in a closed position.
For the purposes of this document the term ‘door’ is used as a general term for ‘industrial, commercial and garage doors and gates’ unless clearly stated.

  • Draft
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the test method and/or calculation of resistance to wind load for industrial, commercial and garage doors and gates according prEN 13241:2020 in a closed position.
For the purposes of this document the term ‘door’ is used as a general term for ‘industrial, commercial and garage doors and gates’ unless clearly stated.

  • Draft
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the test method for determining the resistance to water penetration for industrial, commercial and garage doors and gates according prEN 13241:2020 in a closed position.
For the purposes of this document the term ‘door’ is used as a general term for ‘industrial, commercial and garage doors and gates’ unless clearly stated.

  • Draft
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements and test methods for the safety in use of power operated door, gate and barrier, intended for installation in areas in the reach of persons, and for which the main intended use is  giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises.
This European Standard also covers power operated vertically moving commercial doors such as rolling shutters and rolling grilles, used in retail premises which are mainly provided for goods protection.
This European Standard deals with all significant hazards, hazardous situations and events relevant to the power operation of industrial, commercial and garage doors, and gates when they are used as intended and under conditions of misuse which are reasonably foreseeable as identified in Clause 4.
All lifetime phases of the machinery including transportation, assembly, dismantling, disabling and scrapping are considered by this standard.
This European Standard does not apply to
-   lock gates and dock gates;
-   doors on lifts;
-   doors on vehicles;
-   armoured doors;
-   doors mainly for the retention of animals, unless they are at the site perimeter ;
-   theatre textile curtains;
-   horizontally moving power operated doors mainly intended for pedestrian use;
-   doors outside the reach of people (such as crane gantry fences);
-   railway barriers;
-   barriers intended solely for use by pedestrians;
-   barriers used solely for vehicles on motorways.
Whenever the term "door" is used in this document, it shall be deemed to cover the full scope of types and variances of doors, gates and barriers in the scope of this Standard.
This European Standard does not deal with any specific requirements on noise emitted from power operated door, gate and barrier, intended for installation in areas in the reach of persons, and for which the main intended use is giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises as their noise emission is not considered to be a relevant hazard.
NOTE   Noise emission of power operated doors is not a significant hazard for the users of these products. It is a comfort aspect.
This European Standard is not applicable to machinery which are manufactured before the date of publication of the standard.

  • Draft
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies mechanical requirements and test methods for manually operated doors, gates and barriers, intended for installation in areas in the reach of persons, and for which the main intended use is giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises.
This European Standard also covers manually operated vertically moving commercial doors such as rolling shutters and rolling grilles, used in retail premises which are mainly provided for goods protection.
This document applies only to doors which are not part of the load carrying structure of the building.
It does not apply to
-   lock gates and dock gates;
-   doors on vehicles;
-   doors mainly for the retention of animals unless they are at the site perimeter;
-   doors intended for pedestrian use;
-   railway barriers.
Whenever the term "door" is used in this document, it is deemed to cover the full scope of types and variances of doors, gates and barriers defined by the scope of this Standard.

  • Draft
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements and test methods for sensitive protective equipment to be used with power operated industrial/commercial/garage doors, gates and barriers covered by EN 12453 and power operated pedestrian doors covered by EN 16005.
NOTE   "safety protective equipment" means a device:
-   which serves to fulfil a safety function,
-   which is independently placed on the market,
-   the failure and/or malfunction of which endangers the safety of persons, and
-   which is not necessary in order for the machinery to function, or for which normal components may be substituted in order for the machinery to function.
Whenever the term "door" is used in this document, it need to be deemed to cover the full scope of types and variances of doors, gates and barriers defined by the scope of EN 12453 and EN 16005.
This standard does not deal with sensitive protective equipment using ultrasonic, radar, capacitive, inductive or active infrared technologies.
This standard does not apply to inherent sensitive protective equipment.

  • Draft
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the information to be provided to ensure safe use, including installation, maintenance and repair and dismantling of manual and power operated industrial, commercial and garage doors and gates and barriers intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises.
This European Standard also covers power operated vertically moving commercial doors such as rolling shutters and rolling grilles, used in retail premises which are mainly provided for goods protection.
This European Standard does not apply to:
-   lock gates and dock gates;
-   doors on lifts;
-   doors on vehicles;
-   armoured doors;
-   doors mainly for the retention of animals, unless they are at the site perimeter ;
-   theatre textile curtains;
-   horizontally moving power operated doors mainly intended for pedestrian use;
-   doors outside the reach of people (such as crane gantry fences);
-   railway barriers;
-   barriers intended solely for use by pedestrians;
-   barriers used solely for vehicles on motorways.
Whenever the term "door" is used in this document, it is deemed to cover the full scope of types and variances of doors, gates and barriers defined by the scope of this Standard.

  • Draft
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1 General This standard specifies the performance requirements in regard of the safety in use for any type of power operated
doors, gates and barriers intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises. 1.2 Exclusions
It does not apply to - lock gates and dock gates; - doors on lifts; - doors on vehicles; - armoured doors; - doors mainly for the retention of animals; - theatre textile curtains; - horizontally moving doors < 2,5 m wide and 6,25 m² area, designed principally for pedestrian use;
- revolving doors of any size; - doors outside the reach of people (such as crane gantry fences); - railway barriers; - barriers used solely for vehicles. 1.3 Specific applications Doors, gates and barriers can be of sliding, sidefolding, tilting, pivoting, rolling, vertical lifting and other types with many variances for each type. If not specified otherwise, the word "door" refers to any of these types and variances of doors, gates and barriers. In the following, a power-operated door is considered as a whole. Nevertheless such a door can be the result of
the implementation of a drive unit onto a manual door. In that case, this standard is applicable for the completed final installation.
Requirements for specific characteristics (such as fire resistance, blast-resistance, acoustic, escape route function, burglar resistance or thermal insulation, etc.) which certain doors are required to comply with, are notspecified in this standard. If the specifications of a standard on the special characteristics of such doors are in conflict with the requirements of this standard, that standard has preference.

  • Draft
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the test methods to be applied to a power operated door, gate or barrier to demonstrate compliance with the requirements specified in prEN 12453:2005. In particular it specifies the method of measuring the forces developed by a power operated door, gate or barrier.
It applies to any power operated door, gate or barrier covered by prEN 12453:2005.
This document does not apply to power operated doors, gates and barriers which are manufactured before the date of publication of this document by CEN.

  • Draft
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

General
This document specifies the methods to verify the safety requirements stated in prEN 12604:2005 for doors, gates and barriers or their components intended for installation in areas in the reach of people and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial and residential premises.
Exclusions
It does not apply to
   lock gates and dock gates;
   doors on lifts;
   doors on vehicles;
   armoured doors;
   doors mainly for the retention of animals;
   theatre textile curtains;
   horizontally moving doors less than 2,5 m wide and 6,25 m2 area, designed principally
   for pedestrian use;
   doors outside the reach of people (such as crane gantry fences);
   revolving doors of any size;
   railway barriers;
   barriers used solely for vehicles.
This document is not applicable to doors, gates and barriers which are manufactured before the date of publication of this document by CEN.
Specific applications
This document applies only to doors which are not part of the load carrying structure of the building.

  • Draft
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the safety, structural and mechanical requirements for doors, gates and barriers or their components, intended for installation in areas in the reach of people and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial and residential premises.
This document also covers commercial doors such as rolling shutters and rolling grilles used in retail premises which are mainly provided for the access of persons rather than vehicles or goods.
This document deals with all significant hazards listed in Annex A and specifies requirements to eliminate or minimise them.
These products may be manually or power operated. Calculation and sizing of the drive unit is not covered in this document.

  • Draft
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   General
This European Standard specifies the safety and performance requirements for doors, gates and barriers, intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises.
This European Standard also covers commercial doors such as rolling shutters and rolling grilles used in retail premises which are mainly provided for the access of persons rather than vehicles or goods.
These doors can include pass doors incorporated in the door leaf which are also covered by this European Standard.
These devices can be manually or power operated.
This European Standard does not cover operation in environments where the electromagnetic disturbances are outside the range of those specified in EN 61000-6-3.
1.2   Exclusions
This European Standard does not apply to the following which are intended for a different use:
-   lock gates and dock gates;
-   doors on lifts;
-   doors on vehicles;
-   armoured doors;
-   doors mainly for the retention of animals;
-   theatre textile curtains;
-   horizontally moving manually operated pedestrian doors with a leaf size less than 6,25 m²;
-   horizontally moving power operated doors less than 2,5 m wide and 6,25 m² area, designed principally for pedestrian use in accordance with prEN 12650-1;
-   revolving doors of any size;
-   railway barriers;
-   barriers used solely for vehicles.
This European Standard does not cover the radio part of doors. If a radio operating device is used, the relevant ETSI standards should be applied in addition.
This European Standard does not contain any specific requirements for fire resistance or smoke control characteristics which are covered in prEN 13241-2.
(....)

  • Draft
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   General
This European Standard specifies the information to be provided by the door manufacturer and the components manufacturer to ensure safe installation, operation, use (including maintenance and repair) of doors, gates and barriers intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises.
This European Standard also covers commercial doors such as rolling shutters and rolling grilles used in retail premises which are mainly provided for the access of persons rather than vehicles or goods.
This European Standard applies to manually operated and power operated doors, to doors and components intended to be installed by “non professional installers” and may also apply to the installation and use of upgrading component(s).
The European Standard only applies to the doors and components manufactured after the date of publication.
1.2   Exclusions
This European Standard does not apply to doors that are intended for a different use than the one described in 1.1 such as:
-   lock gates and dock gates;
-   doors on lifts;
-   doors on vehicles;
-   doors mainly for the retention of animals;
-   theatre textile curtains;
-   railway barriers;
-   barriers used solely for vehicles.
This European Standard does not apply to machinery other than power operated doors.
This European Standard does not cover operation in environments where the electromagnetic disturbances are outside the range of those specified in EN 61000-6-2 or for domestic garage doors those specified in EN 55014-2.
This European Standard does not cover:
- products to be used in potential explosive atmosphere or on armoured doors;
- programmable devices (see IEC 61508 series);
- shock resistance of component (example IK code).
These exclusions are based on technology used at the publication time of this standard.
When a door is part of

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    16 pages
    German language
    sale 10% off
    e-Library read for
    1 day
  • Standard – translation
    18 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements and test methods for the safety in use of power operated door, gate and barrier, intended for installation in areas in the reach of persons, and for which the main intended use is  giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises.
This European Standard also covers power operated vertically moving commercial doors such as rolling shutters and rolling grilles, used in retail premises which are mainly provided for goods protection.
This European Standard deals with all significant hazards, hazardous situations and events relevant to the power operation of industrial, commercial and garage doors, and gates when they are used as intended and under conditions of misuse which are reasonably foreseeable as identified in Clause 4.
All lifetime phases of the machinery including transportation, assembly, dismantling, disabling and scrapping are considered by this standard.
This European Standard does not apply to
-   lock gates and dock gates;
-   doors on lifts;
-   doors on vehicles;
-   armoured doors;
-   doors mainly for the retention of animals, unless they are at the site perimeter ;
-   theatre textile curtains;
-   horizontally moving power operated doors mainly intended for pedestrian use;
-   doors outside the reach of people (such as crane gantry fences);
-   railway barriers;
-   barriers intended solely for use by pedestrians;
-   barriers used solely for vehicles on motorways.
Whenever the term "door" is used in this document, it shall be deemed to cover the full scope of types and variances of doors, gates and barriers in the scope of this Standard.
This European Standard does not deal with any specific requirements on noise emitted from power operated door, gate and barrier, intended for installation in areas in the reach of persons, and for which the main intended use is giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises as their noise emission is not considered to be a relevant hazard.
NOTE   Noise emission of power operated doors is not a significant hazard for the users of these products. It is a comfort aspect.
This European Standard is not applicable to machinery which are manufactured before the date of publication of the standard.

  • Standard
    61 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements and classification systems for burglar resistant characteristics of pedestrian doorsets, windows, curtain walling, grilles and shutters. It is applicable to the following means of opening: Turning, tilting, folding, turn-tilting, top or bottom hung, sliding (horizontally and vertically) and rolling as well as fixed constructions. It also covers products that include items such as letter plates or ventilation grilles. It specifies requirements for the burglar resistance of a construction product (as defined in 3.1 of this standard).
This European Standard does not directly cover the resistance of locks and cylinders to attack with picking tools. It also does not cover precast concrete elements.
It also does not cover the attack of electric, electronic and electromagnetic operated burglar resistant construction products using attack methods that might defeat these characteristics.
NOTE 1   The mechanical parts of electric, electronic and electromagnetic operated burglar resistant construction products may be tested in electrical powerless condition.
This European Standard does not apply to doors, gates and barriers, intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises, as covered by EN 13241-1.
NOTE 2   Construction products that can be reached or driven through by vehicles should be protected by appropriate measures such as barriers, extensible ramps, etc.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies mechanical requirements and test methods for manually operated doors, gates and barriers, intended for installation in areas in the reach of persons, and for which the main intended use is giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises.
This European Standard also covers manually operated vertically moving commercial doors such as rolling shutters and rolling grilles, used in retail premises which are mainly provided for goods protection.
This document applies only to doors which are not part of the load carrying structure of the building.
It does not apply to
-   lock gates and dock gates;
-   doors on vehicles;
-   doors mainly for the retention of animals unless they are at the site perimeter;
-   doors intended for pedestrian use;
-   railway barriers.
Whenever the term "door" is used in this document, it is deemed to cover the full scope of types and variances of doors, gates and barriers defined by the scope of this Standard.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the test methods to verify the mechanical requirements of manual and power operated industrial, commercial and garage doors and gates and maintenance verification of all doors as specified in EN xxxxxx (WI 236) Industrial, commercial and garage doors and gates - Product standard - General document. This document is including door as: - industrial and commercial doors; - garage doors; - shutters; - barriers; - gates.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the mechanical performance requirements of manual and power operated industrial, commercial and garage doors and gates and defines the minimum requirements to ensure the safe construction and use of doors. NOTE: Use means normal use and foreseeable misuse of the doors. A door is not part of the load carrying structure of the building. This standard is including door as: - industrial and commercial doors; - garage doors; - shutters; - barriers; - gates.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies the test methods to be applied to a power operated door to demonstrate compliance with the requirements specified in prEN 12453 : 2000. In particular it specifies the method of measuring the forces developed by a power operated door.
It applies to any power operated door covered by prEN 12453 : 2000.

  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1 General This standard specifies the performance requirements in regard of the safety in use for any type of power operated
doors, gates and barriers intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises. 1.2 Exclusions
It does not apply to - lock gates and dock gates; - doors on lifts; - doors on vehicles; - armoured doors; - doors mainly for the retention of animals; - theatre textile curtains; - horizontally moving doors < 2,5 m wide and 6,25 m² area, designed principally for pedestrian use;
- revolving doors of any size; - doors outside the reach of people (such as crane gantry fences); - railway barriers; - barriers used solely for vehicles. 1.3 Specific applications Doors, gates and barriers can be of sliding, sidefolding, tilting, pivoting, rolling, vertical lifting and other types with many variances for each type. If not specified otherwise, the word "door" refers to any of these types and variances of doors, gates and barriers. In the following, a power-operated door is considered as a whole. Nevertheless such a door can be the result of
the implementation of a drive unit onto a manual door. In that case, this standard is applicable for the completed final installation.
Requirements for specific characteristics (such as fire resistance, blast-resistance, acoustic, escape route function, burglar resistance or thermal insulation, etc.) which certain doors are required to comply with, are notspecified in this standard. If the specifications of a standard on the special characteristics of such doors are in conflict with the requirements of this standard, that standard has preference.

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   General
This European Standard specifies the safety and performance requirements for doors, gates and barriers, intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises.
This European Standard also covers commercial doors such as rolling shutters and rolling grilles used in retail premises which are mainly provided for the access of persons rather than vehicles or goods.
These doors can include pass doors incorporated in the door leaf which are also covered by this European Standard.
These devices can be manually or power operated.
This European Standard does not cover operation in environments where the electromagnetic disturbances are outside the range of those specified in EN 61000-6-3.
1.2   Exclusions
This European Standard does not apply to the following which are intended for a different use:
-   lock gates and dock gates;
-   doors on lifts;
-   doors on vehicles;
-   armoured doors;
-   doors mainly for the retention of animals;
-   theatre textile curtains;
-   horizontally moving manually operated pedestrian doors with a leaf size less than 6,25 m²;
-   horizontally moving power operated doors less than 2,5 m wide and 6,25 m² area, designed principally for pedestrian use in accordance with prEN 12650-1;
-   revolving doors of any size;
-   railway barriers;
-   barriers used solely for vehicles.
This European Standard does not cover the radio part of doors. If a radio operating device is used, the relevant ETSI standards should be applied in addition.
This European Standard does not contain any specific requirements for fire resistance or smoke control characteristics which are covered in prEN 13241-2.
!deleted text"
(....)

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard identifies the particular requirements and classifications necessary to demonstrate the characteristics of fire resistance, smoke leakage control and self closing durability for pedestrian doorsets, industrial type doorsets and openable windows.
Requirements for performance characteristics for these products can be found in the appropriate product standards.
This document does not cover any component reliability or durability testing of mechanical heat detectors (e.g. fusible link devices).
The requirements relating to the use of alternative items of building hardware are provided.
NOTE   Fire resistance of doorsets and fire resistance of openable windows and smoke control of doorsets which differ from the original test specimen(s) are covered by the fields of direct and extended application relative to the result of test(s) to EN 1634-1 for fire resistance and EN 1634-3 for smoke control.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1 General This European Standard specifies the calculation requirements for the thermal transmittance for doors in a closed position.
The doors are intended for installation in areas in the reach of people, for which the main intended uses are giving safe access for goods, vehicles and persons in industrial, commer-cial or residential premises. The doors may be manually or power operated. This document applies to all doors provided in accordance with prEN 13241:1998. 1.2 Exclusions It does not apply to: - lock gates and dock gates;
- doors on lifts; - doors on vehicles; - armoured doors; - doors mainly for the retention of animals; - theatre textile curtains; - horizontally moving doors less than 2,5 m wide and 6,25 m² area, designed principally for pedestrian use; - revolving doors of any size; - doors outside the reach of people (such as crane gantry fences); - railway barriers; - barriers used solely for vehicles.

  • Standard
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European prestandard specifies requirements and classification for burglar resistant properties of doors, windows and shutters. It is applicable to the following means of opening: turning, tilting, folding, turn-tilting, top or bottom hung, sliding (horizontally and vertically) and rolling, as well as fixed constructions. This European Prestandard is not applicabl to manipulation and burglary attempts in respect of electronic or electromagnetic security devices. Note: Building elements which can be reached or driven through by vehicles should be protected by appropriate measures such as barriers etc.

  • Standardization document
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the safety and performance requirements for doors, gates and barriers, intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises.
This European Standard also covers commercial doors such as rolling shutters and rolling grilles used in retail premises which are mainly provided for the access of persons rather than vehicles or goods.
These doors can include pass doors incorporated in the door leaf which are also covered by this European Standard.
These devices can be manually or power operated.
This European Standard does not cover operation in environments where the electromagnetic disturbances are outside the range of those specified in EN 61000-6-3.

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard applies to safety devices used on power operated doors, as defined and required in EN 12453 "Safety in use of power operated doors - Requirements and classification". This standard contains requirements for design, construction and testing of protective equipment where the equipment is used to detect persons who may be exposed to injury by doors and give an output signal which is used to provide protection for the person who is at risk. It applies to ready to use protective equipment and integrated protective equipment (mounted on or linked to a door as in normal use).

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies requirements for safe assembly, installation, use, operation, maintenance and repair of industrial, commercial and garage doors and gates. It covers manually operated and power operated doors and gates, that are directly operated by the user via controls and those operated by remote or automatic systems that are not controlled directly by the user. This standard applies to doors and gates that are mass produced and also to doors that are special to contract, tailor made products.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day