IEC 62271-214:2019 specifies requirements for internal arc classification of metal-enclosed pole-mounted switchgear installations used for alternating current with rated voltages above 1 kV and up to and including 52 kV with service frequencies up to and including 60 Hz. This document is applicable to three-phase, two-phase and single phase equipment. Enclosures may include fixed and removable components and may be filled with fluid (liquid or gas) to provide insulation.

  • Standard
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62271-209:2019 is available as IEC 62271-209:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62271-209:2019 covers the connection assembly of fluid-filled and extruded cables to gas-insulated metal enclosed switchgear (GIS), in single- or three-phase arrangements where the cable terminations are fluid-filled or dry-type and there is a separating insulating barrier between the cable insulation and the gas insulation of the switchgear. This second edition cancels and replaces the first edition published in 2007. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) New numbering in accordance with ISO/IEC directives, Part 2 (2016) and to IEC 62271‑1:2017; b) Clause 3: addition of a definition for plug-in cable termination, filling pressure and minimum function pressure for insulation; c) Clause 7: An additional dielectric type test for plug-in cable termination was added; also a pressure type test as well as a leak rate test on the insulator of a cable termination was implemented; d) Clause 12: New clause about safety practices; e) Clause 13: New clause about influence of the product on the environment; f) New informative Annex A: Mechanical forces applied on the flange of the cable connection enclosure.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62271-212:2016 specifies the service conditions, rated characteristics, general structural requirements and test methods of the assemblies of the main electrical functional units of a high-voltage/low-voltage distribution substation, duly interconnected, for alternating current of rated operating voltages above 1 kV and up to and including 52 kV on the high-voltage side, service frequency 50 Hz or 60 Hz. This assembly is to be cable-connected to the network, and intended for installation within an indoor or outdoor closed electrical operating area. This publication is to be read in conjunction with IEC 62271-1:2007

  • Standard
    77 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62271-201:2014 specifies requirements for prefabricated solid-insulation enclosed switchgear and controlgear for alternating current of rated voltages above 1 kV and up to and including 52 kV for indoor installation and for service frequencies up to and including 60 Hz. This second edition cancels and replaces the first edition, published in 2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) apart from updating with the second edition of IEC 62271-200 (issued in 2011), definitions, classifications and testing procedures have been specified more precisely; b) access to the solid-insulation enclosed switchgear and controlgear is now restricted to authorized personnel only. This implies that 'accessibility class B' (public access) has been deleted throughout the document; c) the term 'protection category' has been introduced to replace the term 'protection grade' (PA, PB1 and PB2).

  • Standard
    100 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62271-211:2014 is applicable to single and three phase direct connections between gas-insulated metal-enclosed switchgear (GIS) for rated voltages above 52 kV and transformer arrangements to establish electrical and mechanical interchange ability and to determine the limits of supply of for the transformer connection. This first edition cancels and replaces the first edition of IEC TR 61639:1996 and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) transfer from technical report to international standard; b) the minimum voltage rating was changed from 72,5 kV to above 52 kV; c) update of normative references; d) definition of insulated junction including limit of supply; e) definition of dielectric test of gas-insulated metal-enclosed switchgear for transformer connection in a three phase enclosure; f) addition of interface tolerances at transformer side; g) addition of transformer tolerances in service; h) addition of exceptional loads for bushings and flanges; i) consideration of oil- and gas-insulated transformers; j) inclusion of three-phase enclosed direct connections.

  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62271-202:2014 specifies the service conditions, rated characteristics, general structural requirements and test methods of high voltage/low voltage or low voltage/high voltage prefabricated substations, which are cable-connected, to be operated from inside (walk-in type) or outside (non-walk-in type) for alternating current of rated voltages above 1 kV and up to and including 52 kV on the high voltage side, and for one or more transformers for service frequencies up to and including 60 Hz for outdoor installation at locations with public accessibility and where protection of personnel is provided. This second edition cancels and replaces the first edition published in 2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) regarding temperature-rise test an alternative method for liquid filled transformers is (re)introduced and the temperature-rise test method for dry-type transformers is specified more precisely; b) testing procedure for short time and peak withstand current tests are specified more precisely; c) assessment of electromagnetic fields is considered including a type test (optional) according IEC/TR 62271-208:2009; d) influence of the product on the environment is considered (Clause 12); e) internal arc test requirements have been adapted to IEC 62271-200:2011 and requirements for the assessment of pressure relief volumes below the floor / ground has been assigned; f) the method for defining the load factor in an enclosure for liquid filled transformers is extended with different temperature rises for the transformer outside the enclosure (Annex DD); g) for the calculation of the load factor of dry-type transformers in an enclosure the insulation systems according to IEC 60076-1:2011, Tables B.1 and B.2 are worked out in detail.

  • Standard
    100 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62271-207:2012 applies to gas-insulated switchgear assemblies for alternating current of rated voltages above 52 kV for indoor and outdoor installations, including their supporting structure. This second edition of IEC 62271-207 cancels and replaces the first edition published in 2007. It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - modification of the minimum voltage rating from 72,5 kV to above 52 kV; - harmonisation of qualification procedures for GIS with IEEE 693:2005 Annex A and P by modifying the response spectra; - modification of the test procedures; - addition of criteria of allowed stresses; - addition of dynamic analysis CQC.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62271-203:2011 specifies requirements for gas-insulated metal-enclosed switchgear in which the insulation is obtained, at least partly, by an insulating gas other than air at atmospheric pressure, for alternating current of rated voltages above 52 kV, for indoor and outdoor installation, and for service frequencies up to and including 60 Hz. This second edition of IEC 62271-203 cancels and replaces the first edition of IEC 62271-203, published in 2003, and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - adopting the structure and the content to IEC 62271-1, - harmonisation with IEEE C37.122, - addition of the new Annex F and the new Annex G. This publication is to be read in conjunction with IEC 62271-1:2007.

  • Standard
    82 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62271-200:2011 specifies requirements for prefabricated metal enclosed switchgear and controlgear for alternating current of rated voltages above 1 kV and up to and including 52 kV for indoor and outdoor installation, and for service frequencies up to and including 60 Hz. Enclosures may include fixed and removable components and may be filled with fluid (liquid or gas) to provide insulation. This second edition cancels and replaces the first edition, published in 2003. It is a technical revision. This second edition of IEC 62271-200 has been further updated and improved to the experience gained with the first edition of IEC 62271-200. As maintenance result, this second edition of IEC 62271-200 introduces the following significant changes: - definitions, classifications and testing procedures are specified more precisely; - categories LSC2A and LSC2B have been clarified and LSC2 has been assigned a separate definition; - specific ratings related to fault level to earth (4.5 to 4.7) are introduced; - solid insulated high-voltage parts are no longer considered as compartments on their own; - an optional rating 'cable test voltage' and the associated requirements and type tests are introduced; - for testing the internal arc classification, when assigned by the manufacturer, more specific guidance is provided regarding the test arrangement, room simulation and arc initiation; - a single phase to earth ignition is also recognised for internal arc testing; - the Annexes A and B are renumbered Annexes AA and BB. This publication is to be read in conjunction with IEC 62271-1:2007.

  • Standard
    93 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62271-204:2011 applies to rigid HV gas insulated transmission lines (GIL) in which the insulation is obtained, at least partly, by a non-corrosive insulating gas, other than air at atmospheric pressure, for alternating current of rated voltages above 52 kV, and for service frequencies up to and including 60 Hz. This standard cancels and replaces IEC/TS 61640:1998. It is a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - update to be in line with IEC 62271-1:2007 and 62271-203 and alignment of the voltage ratings and the test voltages; - addition of new information for gas tightness and corrosion protection. This publication is to be read in conjunction with IEC 62271-1:2007.

  • Standard
    58 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62271-206:2011 is applicable to voltage presence indicating systems (VPIS) incorporated in a.c. switchgear and controlgear covered by IEC 62271-200 or IEC 62271-201. Voltage presence indicating systems are devices used to provide information to operators about the voltage condition of the main circuit of the switchgear in which they are installed. This first edition of IEC 62271-206 cancels and replaces the first edition of IEC 61958. This edition constitutes a minor revision. The main changes with respect of the first edition of IEC 61958 are an actualization of references and the degree of protection which has been changed from IPXXB to IP2X.

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC/TR 62271-208:2009 gives practical guidance for the evaluation and documentation of the external electromagnetic fields which are generated by HV switchgear assemblies and HV/LV prefabricated substations. Basic requirements to measure or calculate the electric and magnetic fields are summarised for switchgear assemblies covered by IEC 62271-200 and IEC 62271-201, and for prefabricated substations covered by IEC 62271-202. This technical report applies to equipment rated for voltages up to and including 52 kV and power-frequencies from 15 Hz to 60 Hz.

  • Technical report
    48 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the service conditions, rated characteristics, general structural requirements and test methods of the prefabricated assembly of the main electrical functional units of a HV/LV Distribution Substation, duly interconnected, for alternating current of rated operating voltages above 1 kV and up to and including 52 kV on the HV side, service frequency 50 Hz. This assembly is to be cable-connected to the network. This Compact Equipment Assembly for Distribution Substation (CEADS) as defined in this standard is designed and tested to be a single product with a single serial number and one set of documentation. Such equipment is delivered as single transport unit. For practical reasons manufacturer and user can agree to transport the unit dismantled if transport or installation of the complete CEADS is not possible. In that case suitable verification tests shall be carried out at the installation site. Note 1: Where the functional units are independent each functional unit will also have its own serial number. A CEADS is not a Distribution Substation, either prefabricated (covered by EN 62271 202) or not (covered by EN 61936-1). However CEADS is intended to become part of a Distribution Substation assembling the HV equipment, the power transformer and the LV equipment duly interconnected (see Annex C, which also explains the origin and types of CEADS). The functions of a CEADS are: – switching and control for the operation of the HV side and protection of the HV/LV transformer functional unit; – HV/LV transformation; – switching and control for the operation and protection of the LV feeders. However relevant provisions of this standard are also applicable to designs where not all of these functions exist (e.g. equipment comprising only HV/LV transformation and switching and control for the operation and protection of the LV feeder functions). For public distribution networks, CEADS are intended for installation within an indoor or outdoor closed electrical operating area (see Definition 1.3.3) forming part of a Distribution Substation. For industrial applications, such as factories, installation of CEADS outside a closed electrical operating area may be allowed provided that safety regulations are fulfilled by additional measures adopted at the installation site under the responsibility of the designer of the installation. This standard considers the potential interaction between the individual functions when closely installed and interconnected to form a type tested assembly and defines ratings, particular design and construction requirements and test procedures for this assembly. NOTE 2 Interaction is the influence of one functional units of the equipment on another (i.e. electrical mechanical and thermal stresses). NOTE 3 For the purpose of this standard a self-protected transformer is considered not as a CEADS, but as a functional unit, designed and type tested to its own product standard EN 60076 13.

  • Standard
    63 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC/TS 62271-304:2008 applies to indoor enclosed switchgear and controlgear complying with IEC 62271-200 and IEC 62271-201, intended to be used in service conditions more severe with respect to condensation and pollution than the normal service conditions specified in IEC 62271-1. This technical specification covers equipment where any of the insulation is exposed to indoor climatic conditions. This first edition of IEC/TS 62271-304 cancels and replaces the first edition of IEC/TS 60932, published in 1988, and constitutes a technical revision. This revised document has been basically changed to be updated to today's use of high-voltage switchgear and controlgear up to 52 kV. The contents of the corrigendum of January 2010 have been included in this copy.

  • Technical specification
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 62271 applies to compact switchgear assemblies consisting of at least one switching device directly connected to, or sharing components with, one or more other devices such that there is an interaction between the functions of the individual devices. Such assemblies are made up of devices defined in 1.101 and are designed, tested and supplied for use as a single unit. The interaction between devices may be due to proximity, sharing of components or a combination of both. The assemblies may contain components of air insulated switchgear (AIS) only or a combination of AIS and gas insulated switchgear (GIS), so called mixed technology switchgear (MTS) and may be delivered entirely prefabricated or partially assembled.

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard covers the connection assembly of fluid-filled and extruded cables to gas-insulated metal enclosed switchgear (GIS), in single- or three-phase arrangements where the cable-terminations are fluid-filled or dry type and there is a separating insulating barrier between the cable insulation and the gas insulation of the switchgear.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard applies to compartments pressurized at a maximum pressure of 3 bar (gauge) and with a maximum product pressure x volume of 2000 bar liters with inert gases, for example sulphur hexafluoride or nitrogen or a mixture of such gases, used in indoor or outdoor installations of AC switchgear and controlgear with rated voltages above 1 kV up to and including 52 kV where the gas is used principally for its dielectric and/or arc-quenching properties

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Corrigendum to EN issued August 2007

  • Amendment
    3 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard applies to welded composite enclosures of cast and wrought aluminium and aluminium alloy enclosures pressurized with dry air, inert gases, for example sulphur hexafluoride or nitrogen or a mixture of such gases, used in indoor or outdoor installations of high-voltage switchgear and controlgear with rated voltages of 72,5 kV and above, where the gas is used principally for its dielectric and/or arc-quenching properties. The enclosures comprise parts of electrical equipment not necessarily limited to the following examples: circuit-breakers, switch-disconnectors, disconnectors, earthing switches, current transformers, voltage transformers, surge arrestors, busbars and connections. The scope covers also pressurized components such as the centre-chamber of live tank switchgear and controlgear, gas-insulated current transformers, etc.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard applies to fusion welded wrought aluminium and aluminium alloy enclosures pressurized with dry air, inert gases, for example sulphur hexafluoride or nitrogen or a mixture of such gases, used in indoor or outdoor installations of high-voltage switchgear and controlgear with rated voltages of 72,5 kV and above, where the gas is used principally for its dielectric and/or arc-quenching properties. The enclosures comprise parts of electrical equipment not necessarily limited to the following examples: circuit-breakers, switch-disconnectors, disconnectors, earthing switches, current transformers, voltage transformers, surge arrestors, busbars and connections. The scope covers also pressurized components such as the centre-chamber of live tank switchgear and controlgear, gas-insulated current transformers, etc.

  • Standard
    80 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard applies to switchgear assemblies for alternating current of rated voltages above 52 kV for indoor and outdoor installations, including their supporting structure rigidly connected to the ground, and does not cover the seismic qualification of live tank circuit breakers. Switchgear assemblies do have typically low centers of gravity, e.g. gas-insulated switchgear (GIS). This first edition of IEC 62271-207 cancels and replaces the first edition of IEC 62271-2 and constitutes a technical revision. The change from IEC 62271-2 is as follows: -the minimum voltage rating was changed from 72,5 kV to above 52 kV

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 62271 specifies the service conditions, rated characteristics, general structural requirements and test methods of HV/LV or LV/HV prefabricated substations, which are cable-connected, to be operated from inside (walk-in type) or outside (non-walk-in type) for alternating current of rated voltages above 1 kV and up to and including 52 kV on the HV side, and for one or more transformers for service frequencies up to and including 60 Hz for outdoor installation in locations with public accessibility.

  • Standard
    75 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard is applicable to high-voltage switchgear and controlgear (scope of IEC SC 17A) and assemblies thereof (scope of IEC SC 17C) and specifies equipment for digital communication with other parts of the substation and its impact on testing. This equipment for digital communication, replacing metal parallel wiring, can be integrated into the high-voltage switchgear, controlgear, and assemblies thereof, or can be an external equipment in order to provide compliance for existing switchgear and controlgear and assemblies thereof with the standards of the IEC 61850 series.

  • Standard
    51 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 62271 specifies requirements for factory-assembled insulation-enclosed switchgear and controlgear for alternating current of rated voltages above 1 kV and up to and including 52 kV for indoor installation and for service frequencies up to and including 60 Hz.

  • Standard
    89 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Specifies requirements for gas-insulated, metal-enclosed switchgear in which the insulation is obtained, at least partly, by an insulating gas other than air at atmospheric pressure, for alternating current of rated voltages above 52 kV, for indoor and outdoor installation, and for service frequencies up to and including 60 Hz. For the purpose of this standard, the terms GIS and switchgear are used for gas-insulated metal-enclosed switchgear. The gas-insulated metal-enclosed switchgear covered by this standard consists of individual components intended to be directly connected together and able to operate only in this manner. This standard completes and amends, if necessary, the various relevant standards applying to the individual components constituting GIS. This first edition of EN 62271-203 cancels and replaces the third edition of EN 60517, published in 1990, and constitutes a technical revision. With the revision, significant changes from the previous edition have been made. The most important changes are deleting not used technologies, like 3-phase PD measurements, adopting the content to EN 62271-1 'Common Clauses' and harmonisation with IEEE C37.122. This standard is now more up to date to today's products on the world market. This International Standard should be read in conjunction with EN 60694, second edition, published in 1996, its Amendment 1 (2000) and its Amendment 2 (2001), to which it refers and which is applicable unless otherwise specified.

  • Standard
    74 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Specifies requirements for factory-assembled metal-enclosed switchgear and controlgear for alternating current of rated voltages above 1 kV and up to and including 52 kV for indoor and outdoor installation, and for service frequencies up to and including 60 Hz. Enclosures may include fixed and removable components and may be filled with fluid (liquid or gas) to provide insulation. This standard defines several types of metal enclosed switchgear and controlgear which differ due to - the consequences on network service continuity in case of maintenance on the switchgear and controlgear; - the need and convenience of maintenance of the equipment. For metal-enclosed switchgear and controlgear containing gas-filled compartments, the design pressure is limited to a maximum of 300 kPa (relative pressure). Metal-enclosed switchgear and controlgear for special use, for example, in flammable atmospheres, in mines or on board ships, may be subject to additional requirements. Components contained in metal-enclosed switchgear and controlgear are to be designed and tested in accordance with their various relevant standards. This standard supplements the standards for the individual components regarding their installation in switchgear and controlgear assemblies. This standard does not preclude that other equipment may be included in the same enclosure. In such a case, any possible influence of that equipment on the switchgear and controlgear is to be taken into account. This first edition of EN 62271-200 cancels and replaces the third edition of EN 60298, published in 1990, and constitutes a technical revision. Significant technical changes from the third edition of EN 60298 are as follows: This revised document has been basically changed to be updated to today's use of high- voltage switchgear and controlgear up to 52 kV. The main changes are: new definitions and classification of equipment, introduction of internal arc classes (IAC) and its testing. This standard is to be rea

  • Standard
    90 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to all switchgear and their assemblies for alternating current of rated voltages of 72,5 kV and above for indoor and outdoor installation, including their supporting structure rigidly connected to the ground. Where switchgear and their assemblies are not ground mounted, e.g. in a building, conditions for application are subject to agreement between users and manufacturers. The seismic qualification of the switchgear and their assemblies take into account any auxiliary and control equipment either directly mounted or as a separate structure. This standard provides procedures to seismically qualify ground mounted switchgear and their assemblies for rated voltages of 72,5 kV and above. The seismic qualification of the switchgear and their assemblies is only performed upon request. This standard specifies seismic severity levels and gives a choice of methods that may be applied to demonstrate the performance of high-voltage switchgear and their assemblies for which seismic qualification is required.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Is applicable to voltage presence indicating systems (VPIS) incorporated in a.c. switchgear and controlgear coverred by EN 60298 or EN 60466. Is also applicable to phase comparators specifically designed for use with VPIS.

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Superseded by EN 62271-200:2004

  • Amendment
    2 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Superseded by EN 62271-203:2004

  • Amendment
    2 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Specifies requirements for gas-insulated metal-enclosed switchgear in which the insulation is obtained, at least partly, by an insulating gas other than air at atmospheric pressure, for alternating current of rated voltages of 72.5 kV and above, for indoor and outdoor installation, and for service frequencies up to and including 60 Hz. For the purpose of this standard the term 'switchgear' is used for 'gas-insulated metal-enclosed switchgear'.

  • Standard
    69 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This publication completes EN 60694 as regards a.c. metal-enclosed switchgear and controlgear and applies also to gas-filled compartments used in metal-enclosed switchgear and controlgear. Defines service conditions, applicable terms and rated characteristics. Specifies rules for design and construction and rules for type tests and routine tests. Also provides general information on the selection of devices, tenders, transport, erection and maintenance, etc.

  • Standard
    73 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Specifies the service conditions, rated characteristics, general structural requirements and test method of prefabricated substations, which are cable connected, for alternating current of primary rated voltages above 1 kV and up to and including 52 kV1, and for a transformer of maximum power 1 600 kVA, for service frequencies up to and including 60 Hz.

  • Standard
    51 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard provides test requirements for gas-insulated metal-enclosed disconnectors used to switch small capacitive currents (no load currents) such as occur when sections of busbars or grading capacitors are energized or de-energized.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Supersedes A1:1990 * Corrigendum to EN issued August 2007

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard applies to cast aluminium alloy enclosures pressurized with dry air, insert gases, for example sulphur hexafluoride or nitrogen or a mixture of such gases, used in indoor or outdoor installations of high-voltage switchgear and controlgear with rated voltages above 1 kV, where the gas is used principally for its dielectric and/or arc-quanching properties. The enclosures comprise parts of electrical equipment not necessarily limited to the following examples: circuit breakers, switch-disconnectors, disconnectors, earthing switches, current transformers, voltage transformers, surge arrestors, busbars and connections. The scope also covers pressurized components such as the centre chamber of live tank switchgear, gas-insulated current transformers, etc.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day