IEC 60143-4:2023 specifies the testing of thyristor controlled series capacitor (TCSC) installations used in series with transmission lines. This document also addresses issues that consider ratings for TCSC thyristor valve assemblies, capacitors, and reactors as well as TCSC control characteristics, protective features, cooling system and system operation. IEC 60143-4:2023 cancels and replaces the first edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) thyristor valve testing requirements refer to IEC 62823; b) Formula (1) in Subclause 4.2 has been corrected; c) Hardware-in-the-loop (HIL) tests, Subclause 7.5.4, replaces previously specified real time protection and control system test with network simulator.

  • Standard
    47 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62146-2:2023 is applicable to TRV capacitors used on high-voltage alternating current circuit-breakers with rated voltages above 100 kV with 50 Hz or 60 Hz. TRV capacitors are installed phase to earth, either in parallel to the bushing on dead tank circuit-breakers, or immersed inside the circuit-breaker, or freestanding close to the circuit-breaker. Their function is to limit the transient recovery voltage (TRV) and the rate of rise of recovery voltage (RRRV) on the circuit-breaker. Capacitors in compliance with this document can be used as TRV capacitor. This document applies to TRV capacitors falling into one or both of the following categories for: - mounting on or close to air insulated switchgear (AIS) dead tank and live tank circuit-breakers, or - mounting on gas insulated switchgear (GIS) circuit-breakers. The testing for each of the above applications is in some cases different. This document does not apply to grading capacitors installed in parallel to the chambers of the circuit-breaker, which are specified in IEC 62146-1. This document does not apply to capacitors not directly associated with high-voltage alternating current circuit-breakers. The object of this document is: - to define uniform rules regarding performances, testing and rating - to define specific safety rules - to provide a guidance for installation and operation The TRV capacitor is a sub-component for the circuit-breaker and is specified in accordance with the circuit-breaker specifications according to IEC 62271-1, IEC 62271-100, and if applicable to IEC 62271-203. TRV capacitors are commonly built with composite or ceramic housings (insulators). Those insulators follow IEC 61462 or IEC 62155. Other housings can be used if they can sustain applicable type tests according to IEC 61462 and IEC 62155. This International Standard is to be used in conjunction with IEC 62146-1:2013 and IEC 62146-1:2013/AMD1:2016.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60358-4:2018 applies to DC or AC single-phase capacitor-dividers connected between line and ground used for manufacturing Voltage Transformers as well as for other applications. IEC 60358-4:2018 is to be used in conjunction with the latest edition of IEC 60358-1 and its amendments. IEC 60358-4:2018 was established on the basis of the IEC 60358-1:2012. IEC 60358-4:2018 supplements or modifies the corresponding clauses in IEC 60358-1:2012. This standard cancels and replaces the second edition of IEC 60358 (1990), and constitutes a technical revision.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

his document is applicable to both self-healing capacitor units and self-healing capacitor banks intended to be used, particularly, for power-factor correction of AC power systems having a rated voltage above 1 000 V and fundamental frequencies of 15 Hz to 60 Hz. The following capacitors are excluded from this document: - shunt power capacitors of the self-healing type for AC systems having a rated voltage up to and including 1 000 V (IEC 60831-1, -2); - shunt power capacitors of the non-self-healing type for AC systems having a rated voltage up to and including 1 000 V (IEC 60931-1, -2 and -3); - shunt capacitors of the non-self-healing type for AC power systems having a rated voltage above 1 000 V (IEC 60871-1, -2, -3 and -4); - capacitors for inductive heat-generating plants operating at frequencies between 40 Hz and 24 000 Hz (IEC 60110-1 and -2); - series capacitors (IEC 60143-1, -2, -3 and -4); - AC motor capacitors (IEC 60252-1 and -2); - coupling capacitors and capacitor dividers (IEC 60358-1, -2, -3, -4); - capacitors for power electronic circuits (IEC 61071); - small AC capacitors to be used for fluorescent and discharge lamps (IEC 61048 and IEC 61049); - capacitors for suppression of radio interference; - capacitors intended to be used in various types of electrical equipment, and thus considered as components; - capacitors intended for use with DC voltage superimposed on the AC voltage. Requirements for accessories such as insulators, switches, instrument transformers and external fuses are given in the relevant IEC standards and are not covered by the scope of this document. The object of this document is to: a) formulate uniform rules regarding performances, testing and rating; b) formulate specific safety rules; c) provide a guide for installation and operation.

  • Standard
    59 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60143-1:2015 applies both to capacitor units and capacitor banks intended to be used connected in series with an a.c. transmission or distribution line or circuit forming part of an a.c. power system having a frequency of 15 Hz to 60 Hz. The primary focus of this standard is on transmission application. The series capacitor units and banks are usually intended for high-voltage power systems. This standard is applicable to the complete voltage range. This standard does not apply to capacitors of the self-healing metallized dielectric type. The following capacitors, even if connected in series with a circuit, are excluded from this standard: - capacitors for inductive heat-generating plants (IEC 60110-1); - capacitors for motor applications and the like (IEC 60252 (all parts)); - capacitors to be used in power electronics circuits (IEC 61071); - capacitors for discharge lamps (IEC 61048 and IEC 61049). For standard types of accessories such as insulators, switches, instrument transformers, external fuses, etc. see the pertinent IEC standard. The object of this standard is: - to formulate uniform rules regarding performance, testing and rating; - to formulate specific safety rules; - to serve as a guide for installation and operation. This fifth edition cancels and replaces the fourth edition, published in 2004. This edition constitutes a technical revision. The main change with respect to the previous edition is that the endurance test has been replaced by an ageing test because voltage cycling is already performed in the cold duty test. The guide section has been expanded regarding long line correction and altitude correction. In addition the insulation tables and references to other standards have been updated. Keywords: a.c. transmission or distribution line, capacitor units and banks for high-voltage power systems

  • Standard
    66 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60143-3:2015 applies to internal fuses designed to isolate faulty capacitor elements, to allow operation of the remaining parts of that capacitor unit and the bank in which the capacitor unit is connected. Such fuses are not a substitute for a switching device such as a circuit-breaker, or for external protection of the capacitor bank, or any part thereof. The object of this part of IEC 60143 is: - to formulate requirements regarding performance and testing; - to provide a guide for coordination of fuse and bank protection. This second edition cancels and replaces the first edition published in 1998. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: The test procedure has been largely simplified. Keywords: faulty capacitor elements, fuse and bank protection

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60871-1:2014 is applicable to both capacitor units and capacitor banks intended to be used, particularly, for power-factor correction of a.c. power systems having a rated voltage above 1 000 V and frequencies of 15 Hz to 60 Hz. This part of IEC 60871 also applies to capacitors intended for use in power filter circuits. The object of this part of IEC 60871 is as follows: - to formulate uniform rules regarding the performance and rating of units and banks, and the testing of units; to formulate specific safety rules; - to provide a guide for installation and operation. This fourth edition cancels and replaces the third edition published in 2005. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - the overvoltage cycling test has been moved to this standard from the IEC 60871-2; - the ranges of the standardized values of the highest voltage for equipment have been modified; - for installations installed on altitudes above 1 000 m a correction factor to all insulation requirements has been introduced; - new standard insulation tables have been defined. Keywords: capacitor units and capacitor banks, power filter circuits

  • Standard
    58 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60871-4:2014 applies to internal fuses which are designed to isolate faulty capacitor elements, in order to allow operation of the remaining parts of that capacitor unit and the bank in which the capacitor unit is connected. Such fuses are not a substitute for a switching device such as a circuit-breaker, or for external protection of the capacitor bank or any part thereof. The object of this part of IEC 60871 is to formulate requirements regarding performance and testing and to provide a guide for coordination of fuse protection. This second edition cancels and replaces the first edition published in 1996. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: The disconnecting requirements have been modified. Keywords: internal fuses, faulty capacitor elements, fuse protection

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60831-2:2014 applies to capacitors according to IEC 60831-1 and gives the requirements for the ageing test, self-healing test and destruction test for these capacitors. This third edition cancels and replaces the second edition published in 1995. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - Updating of the normative references; - Discharge cycles before ageing test carried out at ambient temperature; - Alternative Self-healing test at d.c. voltage; - Modified acceptance conditions after Self-healing test; - Modifications to Destruction test. Keywords: IEC 60831-1, requirements for the ageing test, self-healing test and destruction test for capacitors

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEW! IEC 60831-1:2014 is available as IEC Standards+ 60831-1:2014 which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 60831-1:2014 is applicable to both capacitor units and capacitor bank s intended to be used, particularly, for power-factor correction of a.c. power systems having a rated voltage up to and including 1 000 V and frequencies of 15 Hz to 60 Hz. This part of IEC 60831 also applies to capacitors intended for use in power filter circuit s. Additional definitions, requirements, and tests for power filter capacitors are given in Annex A. The object of this part of IEC 60831 is to: - formulate uniform rules regarding performances, testing and rating; - formulate specific safety rules; - provide a guide for installation and operation. This third edition cancels and replaces the second edition published in 1996 and Amendment 1:2002. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - Updating of the normative references; - Test conditions have been clarified; - Thermal stability test has been clarified; - Maximum permissible voltage and current have been clarified; - The protection of the environment has been amended with safety concerns and plastic quality requirements. Keywords: capacitor units and capacitor banks, uniform rules regarding performances, testing and rating; safety rules; guide for installation and operation

  • Standard
    40 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60358-3:2013 applies to AC or DC single-phase coupling capacitor, with rated voltage higher than 1 000 V, connected line to ground with the low voltage terminal either permanently earthed or connected to a tuning device for harmonic-filters applications. It replaces Clause 1 of IEC 60358-1:2012. Keywords: AC or DC single-phase coupling capacitor

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62146-1:2013 is applicable to grading capacitors used on circuit-breakers. Their function is to control the voltage distribution across the individual interrupter units of a multi-break circuit-breaker. Grading capacitors can also be used in parallel to the interrupter unit on single break circuit-breakers to modify the Transient Recovery Voltage (TRV). The grading capacitor is a sub-component for the circuit-breaker and shall be specified in accordance with the circuit-breaker specifications. This standard applies to grading capacitors falling into one or both of the following categories for: - mounting on air-insulated circuit-breakers; - mounting on enclosed circuit-breakers (for example immersed in SF6, in oil, etc.). The testing for each of the above applications is in some cases different. The object of this standard is: - to define uniform rules regarding performances, testing and rating; - to define specific safety rules; - to provide a guidance for installation and operation. Keywords: grading capacitors, circuit-breakers

  • Standard
    38 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Ta del IEC 60252 velja za zaganjalne kondenzatorje, namenjene povezavi z navitji asinhronih motorjev, napajanih iz enofaznega sistema, ki imajo frekvenco javnega omrežja. Ta standard zajema zaganjalne kondenzatorje motorjev, ki so ali niso impregnirani in ki imajo dielektrik iz papirja ali plastičnega filma ali kombinacije obeh, ter elektrolitske zaganjalne kondenzatorje, ki nimajo trdnih elektrolitov, z ocenjeno napetostjo do in vključno 660 V.

  • Amendment
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60252 applies to motor capacitors intended for connection to windings of asynchronous motors supplied from a single-phase system having a frequency up to and including 100 Hz, and to capacitors to be connected to three-phase asynchronous motors so that these motors may be supplied from a single-phase system. This standard covers impregnated or unimpregnated capacitors having a dielectric of paper, plastic film, or a combination of both, either metallized or with metal-foil electrodes, with rated voltages up to and including 660 V. Motor start capacitors are covered by IEC 60252-2. The object of this standard is a) to formulate uniform rules regarding performance, testing and rating; b) to formulate specific safety rules; c) to provide a guidance for installation and operation.

  • Amendment
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60358-2:2013 applies to AC or DC single-phase coupling capacitors, with rated voltage > 1 000 V, connected between line and ground with a low voltage terminal either permanently earthed or connected to a device for power line carrier-frequency (PLC) applications at frequencies from 30 kHz to 500 kHz or similar applications (DC or AC) at power frequencies from 15 Hz to 60 Hz. The transmission requirements for coupling devices for power line carrier (PLC) systems are defined in IEC 60481. Keywords: AC or DC single-phase coupling capacitors, power line carrier-frequency (PLC)

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60143-2:2012 covers protective equipment for series capacitor banks, with a size larger than 10 Mvar per phase. Protective equipment is defined as the main circuit apparatus and ancillary equipment, which are part of a series capacitor installation, but which are external to the capacitor part itself. The recommendations for the capacitor part are given in IEC 60143-1:2004. The protective equipment is mentioned in Clause 3 and 10.6 of IEC 60143-1:2004. This second edition cancels and replaces the first edition published in 1994. It constitutes a technical revision. The main changes with respect to the previous edition are: - updated with respect to new and revised component standards; - updates with respect to technology changes. Outdated technologies have been removed, i.e. series capacitors with dual self-triggered gaps. New technologies have been added, i.e. current sensors instead of current transformers; - the testing of spark gaps has been updated to more clearly specify requirements and testing procedures. A new bypass making current test replaces the old discharge current test; - Clause 5, Guide, has been expanded with more information about different damping circuits and series capacitor protections. Keywords: protective equipment for series capacitor banks

  • Standard
    60 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60252-2:2010 applies to motor start capacitors intended for connection to windings of asynchronous motors supplied from a single-phase system having the frequency of the mains. Covers impregnated or unimpregnated metallized motor start capacitors having a dielectric of paper or plastic film, or a combination of both and electrolytic motor start capacitors with non-solid electrolyte, with rated voltages up to and including 660 V. The main changes with respect to the previous edition are: - definition of segmented film capacitors; - clearer definition of the purpose of d.c. conditioning in destruction test.

  • Standard
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60252-1:2010 applies to motor capacitors intended for connection to windings of asynchronous motors supplied from a single-phase system having a frequency up to and including 100 Hz, and to capacitors to be connected to three-phase asynchronous motors so that these motors may be supplied from a single-phase system. This standard covers impregnated or unimpregnated capacitors having a dielectric of paper, plastic film, or a combination of both, either metallized or with metal-foil electrodes, with rated voltages up to and including 660 V. This edition includes the following significant technical changes with respect to the previous edition: - the definition of 'segmented capacitors' has been added in 3.6; - the definition of 'classes of operation' has been clarified, with the addition of the concept of 'probable life' with reference to statistics, in 3.9; - the following wording 'Operation above the rated voltage will reduce the life expectancy of the capacitor' has been introduced in 6.1. - some clarifications have been added to Clause 8, Marking, mainly for small capacitors.

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60143-4:2010 specifies testing of thyristor controlled series capacitor (TCSC) installations used in series with transmission lines. This standard also addresses issues that consider ratings for TCSC thyristor valve assemblies, capacitors, and reactors as well as TCSC control characteristics, protective features, cooling system and system operation. This part of IEC 60143 is to be used in conjonction with the following standards: IEC 60143-1:2004, IEC 60143-2:1994 and IEC 60143-3:1998.

  • Standard
    57 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60358 applies to: • Capacitors, with rated voltage > 1 000 V, connected line to ground with the low voltage terminal either permanently earthed or connected to devices, for applications listed hereunder and other similar uses. This standard serves as basic standard for the coupling capacitor, the different parts of this standard will present the supplementary specifications and tests, for example IEC 60358-2, IEC 60358-3 or IEC 60358-4.

  • Corrigendum
    8 pages
    English and French language
    sale 10% off
    e-Library read for
    1 day

This International Standard applies to capacitors for power electronics applications. The operating frequency of the systems in which these capacitors are used is usually up to 15kHz, while the pulse frequencies may be up to 5 to 10 times the operating frequency. The standard distinguishes between a.c. and d.c. capacitors which are considered as components when mounted in enclosures. This standard covers an extremely wide range of capacitor technologies for numerous applications, e.g. overvoltage protection, d.c. and a.c. filtering, switching circuits, d.c. energy storage, auxiliary inverters, etc.

  • Standard
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applicable to low-voltage a.c. capacitor banks intended to be used for power factor correction purposes, equipped with a built-in switchgear and controlgear apparatus capable of connecting to or disconnecting from the mains part(s) of the bank with the aim to correct its power factor.

  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Is applicable both to indoor capacitor units and indoor capacitor banks intended to be used, particularly, for power factor correction in induction heating, melting, stirring or casting installations, and similar applications with controlled or adjustable a.c. voltage systems in a frequency range up to 50 kHz, and with a rated voltage not exceeding 3,6 kV.

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Gives guidance for the use of passive a.c. harmonic filters and shunt capacitors for the limitation of harmonics and power factor correction intended to be used in industrial applications, at low and high voltages. The measures proposed in this standard are applicable to harmonic orders greater than 1 and up to and including 25.

  • Standard
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to non-self-healing capacitor units and capacitor banks intended to be used for power-factor correction of a.c. power systems having a rated voltage up to and including 1000 V and frequencies 15 Hz to 60 Hz. Also applies to capacitors intended for use in power filter circuits.

  • Standard
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to capacitors for microwave ovens operating at rated a.c. voltages of up to 3 000 V and a superimposed d.c. voltage of up to 1.13 times the value of rated a.c. voltage. Relates specifically to capacitors with a metal case and an upper rated maximum temperature of up to 100 °C, non-self-healing, with metal foil electrodes and dielectrics of paper and/or plastic, impregnated with a suitable oil. This part contains uniform rules regarding performance, testing and rating and specific safety rules.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to internal fuses which are designed to isolate faulty capacitor elements or capacitor unit, in order to allow operation of the remaining parts of that capacitor unit and the bank. Such fuses are not a substitute for a switching device such as a circuit-breaker, or for external protection of the capacitor bank.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to capacitors according to EN 60931-1 and gives the requirements for the ageing test and destruction test for these capacitors. The two ageing test methods are intended to ensure that the capacitor case temperature is maintained constant during the test. The destruction test is performed to evaluate the behaviour of the capacitor at the end of its life.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This report applies to capacitors according to IEC Publication 871-1 and gives the requirements for endurance testing of these capacitors

  • Standardization document
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Project stopped because deleted at IEC level (lack of experts)

  • Draft
    42 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 60871 is applicable to both capacitor units and capacitor banks intended to be used, particularly, for power-factor correction of a.c. power systems having a rated voltage above 1 000 V and frequencies of 15 Hz to 60 Hz. This part of EN 60871 also applies to capacitors intended for use in power filter circuits.

  • Standard
    54 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to both capacitor units and capacitor banks intended to be used connected in series with an a.c. transmission or distribution line or circuit forming part of an a.c. power system having a frequency of 15 Hz to 60 Hz. Focuses primarily on transmission application. The series capacitor units and banks are usually intended for high-voltage power systems. This standard is applicable to the complete voltage range. This standard formulates uniform rules regarding performance, testing and rating, formulates specific safety rules and serves as a guide for installation and operation.

  • Standard
    63 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to motor start capacitors intended for connection to windings of asynchronous motors supplied from a single-phase system having the frequency of the mains. Covers impregnated or unimpregnated metallized motor start capacitors having a dielectric of paper or plastic film, or a combination of both and electrolytic motor start capacitors with non-solid electrolyte, with rated voltages up to and including 660 V.

  • Standard
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to motor capacitors intended for connection to windings of asynchronous motors supplied from a single-phase system having a frequency up to and including 100 Hz, and to capacitors to be connected to three-phase asynchronous motors so that these motors may be supplied from a single-phase system. This standard covers impregnated or unimpregnated capacitors having a dielectric of paper, plastic film, or a combination of both, either metallized or with metal-foil electrodes, with rated voltages up to and including 660 V.

  • Standard
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Concerns internal fuses designed to isolate faulty capacitor elements, to allow operation of the remaining parts of that capacitor unit and the bank in which the capacitor unit is connected. Such fuses are not a substitute for a switching device such as a circuit-breaker, or for external protection of the capacitor bank, or any part thereof.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to capacitor units and capacitor banks intended to be used in particular for power-factor correction of a.c. power systems having a rated voltage above 1000 V and a frequency of 15 Hz to 60 Hz.

  • Standard
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to self-healing capacitor units and banks intended to be used, in particular, for power-factor correction of a.c. power systems of up to and including 1000 V rated voltage and frequency 15 Hz to 60 Hz. Also applies to capacitors intended for use in power filter circuits.

  • Standard
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to internal fuses which are designed to isolate faulty capacitor elements, in order to allow operation of the remaining parts of that capacitor unit and the bank. Such fuses are not a substitute for a switching device such as a circuit-breaker, or for an external protection of the capacitor bank.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to capacitors according to EN 60831-1 and gives the requirements for ageing test, self-healing test and destruction test for these capacitors.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to capacitors intended to be used in power electronic equipment, particularly for : -semiconductor switching and protection, -filtering and energy storage. The rated voltage of capacitors is limited to 10 000 V. The operating frequency of the systems in which these capacitors are used is usually below 1 000 Hz.

  • Standard
    37 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to power electronic capacitors according to EN 61071-1 and gives the requirements for: - disconnecting test on fuses, - destruction test, - self-healing test, - endurance test of these capacitors. Has the status of a technical report, type 2.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This specification is applicable to fixed a.c. aluminium electrolytic capacitors intended: - for connection to windings of asynchronous motors supplied from a single-phase system having a frequency up to and including 100Hz. - to be connected to three-phase asynchronous motors so that the motors may be supplied from a single-phase system. This specification is not applicable to radio interference suppression capacitors, covered by EN 132 400. Neither is it applicable to capacitors for use in electronic equipment, covered by EN 130 000. It establishes standard terms inspection procedures, methods of test for use in sectional and detail specifications within the CECC System, guide-lines for safety rules and for installation and operation.

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This specification applies to aluminuim electrolytic capacitors with non-solid electrolyte primarily intended for a.c. motor starting applications. It covers capacitors for connection to windings of asynchronous motors supplied from a single-phase system having a frequency of up to and including 100 Hz, with rated voltages up to and including 500 V. It prescribes preferred ratings and characteristics and selects from the specification EN 137000 the appropriate quality assessment procedures, tests and measuring methods and gives general performance requirements for this type of capacitor.

  • Standard
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This blank detail specification is for fixed aluminium electrolytic a.c. capacitors with non-solid electrolyte for motor starter applications

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Covers protective equipment for series capacitor banks, with a size larger than 10 Mvar per phase. Protective equipment is the main circuit apparatus and ancillary equipment, which are part of a series of capacitor installations, but which are external to the capacitor part itself.

  • Standard
    55 pages
    English language
    sale 10% off
    e-Library read for
    1 day