31.060.30 - Paper and plastics capacitors
ICS 31.060.30 Details
Paper and plastics capacitors
Papierkondensatoren. Kunststoffkondensatoren
Condensateurs papier et plastique
Papirni kondenzatorji in folijski kondenzatorji
General Information
e-Library Subscription
Create subscription and get permanent access to documents within 31.060.30 - Paper and plastics capacitors
Currently subscription includes documents marked with .We are working on making all documents available within the subscription.
IEC 60384-16:2019 applies to fixed capacitors with metallized electrodes and polypropylene dielectric for use in electronic equipment. These capacitors can have "self-healing properties" depending on conditions of use. They are mainly intended for use with direct voltage. Capacitors for alternating voltage and pulse applications are not included, but are covered by IEC 60384-17. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384-14. Capacitors for electrical shock hazard protection (covered by IEC 60065) and fluorescent lamp and motor capacitors are also excluded.
- Standard40 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-11:2019 is applicable to fixed direct current capacitors, for rated voltages not exceeding 6 300 V, using as dielectric a polyethylene-terephthalate film and electrodes of thin metal foils. For capacitors with rated voltages exceeding 1 000 V, additional tests and requirements may be specified in the detail specification. The capacitors covered by this document are intended for use in electronic equipment. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384‑14. The object of this document is to prescribe preferred ratings and characteristics and to select from IEC 60384-1:2016 the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. Test severities and requirements prescribed in detail specifications referring to this sectional specification are of an equal or higher performance level. Lower performance levels are not permitted. This edition includes the following significant technical changes with respect to the previous edition: a) revision of all parts of the document based on the ISO/IEC Directives, Part 2:2018, and harmonization with other similar kinds of documents; b) the document structure has been organized to follow new sectional specification structure decided in TC 40; c) revised tables and Clause 5 so as to prevent duplications and contradictions.
- Standard35 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 60384 is applicable to fixed surface mount capacitors for direct current, with
metallized electrodes and polyethylene-terephthalate dielectric for use in electronic equipment.
These capacitors have metallized connecting pads or soldering strips and are intended to be
mounted directly onto printed boards or onto substrates for hybrid circuits. These capacitors
can have "self-healing properties" depending on conditions of use. They are primarily intended
for applications where the AC component is small with respect to the rated voltage.
This part of IEC 60384 specifies preferred ratings and characteristics, and selects from
IEC 60384-1:2021 the appropriate quality assessment procedures, tests and measuring
methods, and gives general performance requirements for this type of capacitor. Test severities
and requirements specified in detail specifications referring to this sectional specification are
of an equal or higher performance level. Lower performance levels are not permitted.
Capacitors for electromagnetic interference suppression are not included, but are covered by
IEC 60384-14.
- Standard40 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-19:2022 is applicable to fixed surface mount capacitors for direct current, with metallized electrodes and polyethylene-terephthalate dielectric for use in electronic equipment. These capacitors have metallized connecting pads or soldering strips and are intended to be mounted directly onto printed boards or onto substrates for hybrid circuits. These capacitors can have "self-healing properties" depending on conditions of use. They are primarily intended for applications where the AC component is small with respect to the rated voltage. This part of IEC 60384 specifies preferred ratings and characteristics, and selects from IEC 60384‑1:2021 the appropriate quality assessment procedures, tests and measuring methods, and gives general performance requirements for this type of capacitor. Test severities and requirements specified in detail specifications referring to this sectional specification are of an equal or higher performance level. Lower performance levels are not permitted. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384‑14. This edition includes the following significant technical changes with respect to the previous edition:
revision of all parts of the document based on the ISO/IEC Directives, Part 2:2021, and harmonization with other similar kinds of documents;
the document structure has been organized to follow new sectional specification structure decided in TC 40;
revised tables and Clause 5 to prevent duplications and contradictions;
in Clause 5.2 (Mounting), 5.2.1, 5.2.2 and 5.2.3 have been added;
in Clause 5.5 (Shear test), 5.5.1 and 5.5.2 have been added;
in Clause 5.14 (Component solvent resistance), 5.14.1 and 5.14.2 have been added. In Table 8 and Table A.2, test 5.14 has been moved before 5.7.5 Final inspections in Group 1A and in Subgroup C1;
in Clause 5.15 (Solvent resistance of marking), 5.15.1 and 5.15.2 have been added;
tangent of loss angle measurement has been added to resistance to soldering heat test;
lot-by-lot and periodical inspection tables including requirements have been moved to Annex A;
revised Inspection Level (IL) of A1 subgroup.
- Standard40 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-19:2022 is applicable to fixed surface mount capacitors for direct current, with metallized electrodes and polyethylene-terephthalate dielectric for use in electronic equipment. These capacitors have metallized connecting pads or soldering strips and are intended to be mounted directly onto printed boards or onto substrates for hybrid circuits. These capacitors can have "self-healing properties" depending on conditions of use. They are primarily intended for applications where the AC component is small with respect to the rated voltage.
This part of IEC 60384 specifies preferred ratings and characteristics, and selects from IEC 60384‑1:2021 the appropriate quality assessment procedures, tests and measuring methods, and gives general performance requirements for this type of capacitor. Test severities and requirements specified in detail specifications referring to this sectional specification are of an equal or higher performance level. Lower performance levels are not permitted.
Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384‑14.
This edition includes the following significant technical changes with respect to the previous edition:
revision of all parts of the document based on the ISO/IEC Directives, Part 2:2021, and harmonization with other similar kinds of documents;
the document structure has been organized to follow new sectional specification structure decided in TC 40;
revised tables and Clause 5 to prevent duplications and contradictions;
in Clause 5.2 (Mounting), 5.2.1, 5.2.2 and 5.2.3 have been added;
in Clause 5.5 (Shear test), 5.5.1 and 5.5.2 have been added;
in Clause 5.14 (Component solvent resistance), 5.14.1 and 5.14.2 have been added. In Table 8 and Table A.2, test 5.14 has been moved before 5.7.5 Final inspections in Group 1A and in Subgroup C1;
in Clause 5.15 (Solvent resistance of marking), 5.15.1 and 5.15.2 have been added;
tangent of loss angle measurement has been added to resistance to soldering heat test;
lot-by-lot and periodical inspection tables including requirements have been moved to Annex A;
revised Inspection Level (IL) of A1 subgroup.
- Standard76 pagesEnglish and French languagesale 15% off
IEC 60384-17:2019 is available as IEC 60384-17:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60384-17:2019 applies to fixed capacitors with metallized electrodes and polypropylene dielectric for use in electronic equipment. Capacitors that have mixed film and metallized electrodes are also within the scope of this standard. These capacitors may have "self-healing" properties depending on conditions of use. Capacitors covered by this specification are mainly intended for use with alternating voltage and/or for pulse applications. The maximum reactive power applicable is 10 000 var and the maximum peak voltage is 3 000 V. This edition includes the following significant technical changes with respect to the previous edition: a) all parts of the document have been revised based on the ISO/IEC Directives, Part 2:2016 (seventh edition) and harmonization between other similar kinds of documents; b) tables and Clause 4 have been revised so as to prevent duplications and contradictions; c) new damp heat steady-state robustness classes with test conditions have been added in text, in Clause 4 and in Annex A.
- Standard47 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 60384 applies to fixed capacitors for direct current, with metallized electrodes
and polyethylene-terephthalate dielectric for use in electronic equipment.
These capacitors have a possibility of "self-healing properties" depending on conditions of use.
They are primarily intended for applications where the AC component is small with respect to
the rated voltage. Two performance grades of capacitors are covered: grade 1 for long-life
application and grade 2 for general application.
Capacitors for electromagnetic interference suppression and surface mount fixed metallized
polyethylene-terephthalate film dielectric DC capacitors are not included, but are covered by
IEC 60384-14 and IEC 60384-19, respectively.
The object of this document is to prescribe preferred ratings and characteristics and to select
from IEC 60384-1 the appropriate quality assessment procedures, tests and measuring
methods, and to give general performance requirements for this type of capacitor. Test
severities and requirements prescribed in detail specifications referring to this sectional
specification are of equal or higher performance level, because lower performance levels are
not permitted.
- Standard35 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 60384 applies to fixed capacitors for direct current, with metallized electrodes and polyethylene-terephthalate dielectric for use in electronic equipment. These capacitors have a possibility of "self-healing properties" depending on conditions of use. They are primarily intended for applications where the AC component is small with respect to the rated voltage. Two performance grades of capacitors are covered: grade 1 for long-life application and grade 2 for general application. Capacitors for electromagnetic interference suppression and surface mount fixed metallized polyethylene-terephthalate film dielectric DC capacitors are not included, but are covered by IEC 60384-14 and IEC 60384-19, respectively. The object of this document is to prescribe preferred ratings and characteristics and to select from IEC 60384-1 the appropriate quality assessment procedures, tests and measuring methods, and to give general performance requirements for this type of capacitor. Test severities and requirements prescribed in detail specifications referring to this sectional specification are of equal or higher performance level, because lower performance levels are not permitted.
- Standard35 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-2:2021 applies to fixed capacitors for direct current, with metallized electrodes and polyethylene-terephthalate dielectric for use in electronic equipment.
These capacitors have a possibility of "self-healing properties" depending on conditions of use. They are primarily intended for applications where the AC component is small with respect to the rated voltage. Two performance grades of capacitors are covered: grade 1 for long-life application and grade 2 for general application.
Capacitors for electromagnetic interference suppression and surface mount fixed metallized polyethylene-terephthalate film dielectric DC capacitors are not included, but are covered by IEC 60384-14 and IEC 60384-19, respectively.
The object of this document is to prescribe preferred ratings and characteristics and to select from IEC 60384-1 the appropriate quality assessment procedures, tests and measuring methods, and to give general performance requirements for this type of capacitor. Test severities and requirements prescribed in detail specifications referring to this sectional specification are of equal or higher performance level, because lower performance levels are not permitted.
This edition includes the following significant technical changes with respect to the previous edition:
a) revision of all parts of the document based on the ISO/IEC Directives, Part 2:2018 and harmonization with other similar kinds of documents;
b) the document structure has been organized to follow the new sectional specification structure decided by TC 40;
c) revision of tables and Clause 5 so as to prevent duplications and contradictions.
- Standard32 pagesEnglish languagesale 15% off
- Standard64 pagesEnglish and French languagesale 15% off
2021-01-15 - IEC Corrected Version.
- Corrigendum5 pagesEnglish languagesale 10% offe-Library read for1 day
2020-12-25 - IEC Corrected Version
- Corrigendum4 pagesEnglish languagesale 10% offe-Library read for1 day
2021-01-15 - IEC Corrected Version.
- Corrigendum5 pagesEnglish languagesale 10% offe-Library read for1 day
2020-12-25 - IEC Corrected Version
- Corrigendum4 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-13:2020 specifies preferred ratings and characteristics, selects from IEC 60384-1:2016 the appropriate quality assessment procedures, tests and measuring methods, and gives general performance requirements for this type of capacitor. Test severities and requirements specified in detail specifications referring to this sectional specification are of an equal or higher performance level. Lower performance levels are not permitted. This part of IEC 60384 applies to fixed direct current capacitors, using as dielectric a polypropylene film with electrodes of thin metal foils. The capacitors covered by this document are intended for use in electronic equipment. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384-14. This edition includes the following significant technical changes with respect to the previous edition: a) revision of all parts of the document based on the ISO/IEC Directives, Part 2:2018, and harmonization with other similar kinds of documents; b) the document structure has been organized to follow new sectional specification structure decided in TC 40; c) revised tables and Clause 5 so as to prevent duplications and contradictions.
- Standard36 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard5 pagesEnglish and French languagesale 15% off
- Standard4 pagesEnglish and French languagesale 15% off
IEC 60384-13:2020 specifies preferred ratings and characteristics, selects from IEC 60384-1:2016 the appropriate quality assessment procedures, tests and measuring methods, and gives general performance requirements for this type of capacitor. Test severities and requirements specified in detail specifications referring to this sectional specification are of an equal or higher performance level. Lower performance levels are not permitted.
This part of IEC 60384 applies to fixed direct current capacitors, using as dielectric a polypropylene film with electrodes of thin metal foils. The capacitors covered by this document are intended for use in electronic equipment.
Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384-14.
This edition includes the following significant technical changes with respect to the previous edition:
a) revision of all parts of the document based on the ISO/IEC Directives, Part 2:2018, and harmonization with other similar kinds of documents;
b) the document structure has been organized to follow new sectional specification structure decided in TC 40;
c) revised tables and Clause 5 so as to prevent duplications and contradictions.
- Standard66 pagesEnglish and French languagesale 15% off
TAN - // IEC Corrigendum
- Corrigendum3 pagesEnglish languagesale 10% offe-Library read for1 day
TAN - // IEC Corrigendum
- Corrigendum3 pagesEnglish languagesale 10% offe-Library read for1 day
This Standard applies to fixed capacitors with metallized electrodes and polypropylene dielectric for use in electronic equipment. These capacitors can have "self-healing properties" depending on conditions of use. They are mainly intended for use with direct voltage. The maximum power to be applied is 500 var at 50 Hz and the maximum peak voltage is 2 500 V. The following two grades are covered; a) Grade 1: for long-life application; b) Grade 2: for general application. Capacitors for alternating voltage and pulse applications are not included, but are covered by IEC 60384-17. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384-14. Capacitors for electrical shock hazard protection (covered by IEC 60065) and fluorescent lamp and motor capacitors are also excluded.
- Standard40 pagesEnglish languagesale 10% offe-Library read for1 day
EN-IEC 60384-11 is applicable to fixed direct current capacitors, for rated voltages not exceeding 6 300 V, using as dielectric a polyethylene-terephthalate film and electrodes of thin metal foils. For capacitors with rated voltages exceeding 1 000 V, additional tests and requirements may be specified in the detail specification. The capacitors covered by this document are intended for use in electronic equipment. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384-14. The object of this document is to prescribe preferred ratings and characteristics and to select from IEC 60384-1:2016 the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. Test severities and requirements prescribed in detail specifications referring to this sectional specification are of an equal or higher performance level. Lower performance levels are not permitted.
- Standard35 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-16:2019 applies to fixed capacitors with metallized electrodes and polypropylene dielectric for use in electronic equipment. These capacitors can have "self-healing properties" depending on conditions of use. They are mainly intended for use with direct voltage.
Capacitors for alternating voltage and pulse applications are not included, but are covered by IEC 60384-17. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384-14. Capacitors for electrical shock hazard protection (covered by IEC 60065) and fluorescent lamp and motor capacitors are also excluded.
The contents of the corrigendum of December 2020 have been included in this copy.
- Standard73 pagesEnglish and French languagesale 15% off
IEC 60384-11:2019 is applicable to fixed direct current capacitors, for rated voltages not exceeding 6 300 V, using as dielectric a polyethylene-terephthalate film and electrodes of thin metal foils. For capacitors with rated voltages exceeding 1 000 V, additional tests and requirements may be specified in the detail specification. The capacitors covered by this document are intended for use in electronic equipment. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384‑14. The object of this document is to prescribe preferred ratings and characteristics and to select from IEC 60384-1:2016 the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. Test severities and requirements prescribed in detail specifications referring to this sectional specification are of an equal or higher performance level. Lower performance levels are not permitted.
This edition includes the following significant technical changes with respect to the previous edition:
a) revision of all parts of the document based on the ISO/IEC Directives, Part 2:2018, and harmonization with other similar kinds of documents;
b) the document structure has been organized to follow new sectional specification structure decided in TC 40;
c) revised tables and Clause 5 so as to prevent duplications and contradictions.
The contents of the corrigendum of April 2020 have been included in this copy.
- Standard65 pagesEnglish and French languagesale 15% off
IEC 60384-3:2006 applies to surface mount tantalum solid electrolyte capacitors. These capacitors are primarily intended to be mounted directly onto substrates for hybrid circuits or onto printed boards. The following two styles are considered: Style 1 - protected capacitors; Style 2 - unprotected capacitors. This third edition cancels and replaces the second edition published in 1989 and constitutes a minor revision related to tables, figures and references This bilingual version, published in 2008-06, corresponds to the English version.
- Standard33 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-17:2019 is available as IEC 60384-17:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60384-17:2019 applies to fixed capacitors with metallized electrodes and polypropylene dielectric for use in electronic equipment. Capacitors that have mixed film and metallized electrodes are also within the scope of this standard. These capacitors may have "self-healing" properties depending on conditions of use. Capacitors covered by this specification are mainly intended for use with alternating voltage and/or for pulse applications. The maximum reactive power applicable is 10 000 var and the maximum peak voltage is 3 000 V. This edition includes the following significant technical changes with respect to the previous edition:
a) all parts of the document have been revised based on the ISO/IEC Directives, Part 2:2016 (seventh edition) and harmonization between other similar kinds of documents;
b) tables and Clause 4 have been revised so as to prevent duplications and contradictions;
c) new damp heat steady-state robustness classes with test conditions have been added in text, in Clause 4 and in Annex A.
The contents of the corrigendum of December 2020 have been included in this copy.
- Standard145 pagesEnglish languagesale 15% off
- Standard90 pagesEnglish and French languagesale 15% off
IEC 60384-19:2015 is applicable to fixed surface mount capacitors for direct current, with metallized electrodes and polyethylene-terephthalate dielectric for use in electronic equipment. These capacitors have metallized connecting pads or soldering strips and are intended to be mounted directly onto substrates for hybrid circuits or onto printed boards. These capacitors may have "self-healing properties" depending on conditions of use. They are primarily intended for applications where the a.c. component is small with respect to the rated voltage. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384 14. This edition includes the following significant technical changes with respect to the previous edition: a) Revised all parts of the document based on the IEC Directives Part 2:2011 (sixth edition) to the extent practicable, and harmonization between other similar kind of documents. b) Revised tables and Clause 4 so as to prevent duplications and contradictions.
- Standard33 pagesEnglish languagesale 10% offe-Library read for1 day
Ta del IEC 60252 velja za zaganjalne kondenzatorje, namenjene povezavi z navitji asinhronih motorjev, napajanih iz enofaznega sistema, ki imajo frekvenco javnega omrežja. Ta standard zajema zaganjalne kondenzatorje motorjev, ki so ali niso impregnirani in ki imajo dielektrik iz papirja ali plastičnega filma ali kombinacije obeh, ter elektrolitske zaganjalne kondenzatorje, ki nimajo trdnih elektrolitov, z ocenjeno napetostjo do in vključno 660 V.
- Amendment11 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 60252 applies to motor capacitors intended for connection to windings of asynchronous motors supplied from a single-phase system having a frequency up to and including 100 Hz, and to capacitors to be connected to three-phase asynchronous motors so that these motors may be supplied from a single-phase system. This standard covers impregnated or unimpregnated capacitors having a dielectric of paper, plastic film, or a combination of both, either metallized or with metal-foil electrodes, with rated voltages up to and including 660 V. Motor start capacitors are covered by IEC 60252-2. The object of this standard is a) to formulate uniform rules regarding performance, testing and rating; b) to formulate specific safety rules; c) to provide a guidance for installation and operation.
- Amendment11 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-3:2016 applies to fixed tantalum electrolytic surface mount capacitors with solid (MnO2) electrolyte primarily intended for d.c. applications for use in electronic equipment. The following two styles are considered:
- Style 1 - Capacitors protected with external materials;
- Style 2 - Capacitors unprotected with external materials. This edition includes the following significant technical changes with respect to the previous edition:
a) Revision of the structure in accordance with ISO/IEC Directives, Part 2:2011 (sixth edition) to the extent practicable, and harmonization between other similar kinds of documents.
b) In addition, Clause 4 and all the tables have been reviewed in order to prevent duplications and contradictions.
- Standard60 pagesEnglish and French languagesale 15% off
IEC 60384-19:2015 is applicable to fixed surface mount capacitors for direct current, with metallized electrodes and polyethylene-terephthalate dielectric for use in electronic equipment. These capacitors have metallized connecting pads or soldering strips and are intended to be mounted directly onto substrates for hybrid circuits or onto printed boards. These capacitors may have "self-healing properties" depending on conditions of use. They are primarily intended for applications where the a.c. component is small with respect to the rated voltage. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384 14. This edition includes the following significant technical changes with respect to the previous edition:
a) Revised all parts of the document based on the IEC Directives Part 2:2011 (sixth edition) to the extent practicable, and harmonization between other similar kind of documents.
b) Revised tables and Clause 4 so as to prevent duplications and contradictions.
- Standard61 pagesEnglish and French languagesale 15% off
IEC 60252-2:2010 applies to motor start capacitors intended for connection to windings of asynchronous motors supplied from a single-phase system having the frequency of the mains. Covers impregnated or unimpregnated metallized motor start capacitors having a dielectric of paper or plastic film, or a combination of both and electrolytic motor start capacitors with non-solid electrolyte, with rated voltages up to and including 660 V. The main changes with respect to the previous edition are: - definition of segmented film capacitors; - clearer definition of the purpose of d.c. conditioning in destruction test.
- Standard46 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60252-1:2010 applies to motor capacitors intended for connection to windings of asynchronous motors supplied from a single-phase system having a frequency up to and including 100 Hz, and to capacitors to be connected to three-phase asynchronous motors so that these motors may be supplied from a single-phase system. This standard covers impregnated or unimpregnated capacitors having a dielectric of paper, plastic film, or a combination of both, either metallized or with metal-foil electrodes, with rated voltages up to and including 660 V. This edition includes the following significant technical changes with respect to the previous edition: - the definition of 'segmented capacitors' has been added in 3.6; - the definition of 'classes of operation' has been clarified, with the addition of the concept of 'probable life' with reference to statistics, in 3.9; - the following wording 'Operation above the rated voltage will reduce the life expectancy of the capacitor' has been introduced in 6.1. - some clarifications have been added to Clause 8, Marking, mainly for small capacitors.
- Standard33 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60252-1:2010 applies to motor capacitors intended for connection to windings of asynchronous motors supplied from a single-phase system having a frequency up to and including 100 Hz, and to capacitors to be connected to three-phase asynchronous motors so that these motors may be supplied from a single-phase system. This standard covers impregnated or unimpregnated capacitors having a dielectric of paper, plastic film, or a combination of both, either metallized or with metal-foil electrodes, with rated voltages up to and including 660 V. This edition includes the following significant technical changes with respect to the previous edition:
- the definition of "segmented capacitors" has been added in 3.6;
- the definition of "classes of operation" has been clarified, with the addition of the concept of "probable life" with reference to statistics, in 3.9;
- the following wording "Operation above the rated voltage will reduce the life expectancy of the capacitor" has been introduced in 6.1.
- some clarifications have been added to Clause 8, Marking, mainly for small capacitors.
- Standard61 pagesEnglish and French languagesale 15% off
- Standard134 pagesEnglish and French languagesale 15% off
IEC 60252-2:2010 applies to motor start capacitors intended for connection to windings of asynchronous motors supplied from a single-phase system having the frequency of the mains. Covers impregnated or unimpregnated metallized motor start capacitors having a dielectric of paper or plastic film, or a combination of both and electrolytic motor start capacitors with non-solid electrolyte, with rated voltages up to and including 660 V. The main changes with respect to the previous edition are:
- definition of segmented film capacitors;
- clearer definition of the purpose of d.c. conditioning in destruction test.
- Standard87 pagesEnglish and French languagesale 15% off
- Standard184 pagesEnglish and French languagesale 15% off
This International Standard defines the conditions of utilization of the recycling symbol of the International Organization for Standardization (ISO) associated with the chemical symbols indicating the electrochemical system of the battery. This standard applies to lead-acid batteries (Pb) and nicke-cadmium batteries (Ni-Cd).
- Standard16 pagesEnglish and French languagesale 15% off
This is an informative document covering the broadest aspects of automatic monitor systems as they apply to traction battery applications. The subject of the guide covers those monitor characteristics and features which need to be controlled, though not necessarily currently available. In addition it accommodates those characteristics which are measurable and provides interpretations of accuracy and reliability of the information generated.[
]This publication has the status of a Technical Report - type 3.
- Standard17 pagesEnglish and French languagesale 15% off
IEC 60384-13:2011 applies to fixed direct current capacitors, using as dielectric a polypropylene film with electrodes of thin metal foils. The capacitors covered by this standard are intended for use in electronic equipment. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384-14. This fourth edition cancels and replaces the third edition published in 2006 and contains the following significant technical changes with respect to the previous edition.
- Table 3, Sampling plan together with numbers of permissible non-conformance for qualification approval test, has been adjusted.
- Table 5, Lot-by-lot inspection, has been changed, highlighting assessment level EZ only.
- Table 6, Periodic inspection, has been changed, highlighting assessment level EZ only.
- Standard53 pagesEnglish and French languagesale 15% off
IEC 60384-2:2011 applies to fixed capacitors for direct current, with metallized electrodes and polyethylene-terephthalate dielectric for use in electronic equipment. These capacitors may have "self-healing properties" depending on conditions of use. They are primarily intended for applications where the a.c. component is small with respect to the rated voltage. Two performance grades of capacitors are covered, Grade 1 for long-life application and Grade 2 for general application. Capacitors for electromagnetic interference suppression and surface mount fixed metallized polyethylene-terephthalate film dielectric d.c. capacitors are not included, but are covered by IEC 60384-14 and IEC 60384-19 respectively. This fourth edition cancels and replaces the third edition published in 2005 and contains the following significant technical changes with respect to the previous edition.
- Table 1, Sampling plan together with numbers of permissible non-conformance for qualification approval test, has been adjusted.
- Table 3, Lot-by-lot inspection, has been changed, highlighting assessment level EZ only.
- Table 4, Periodic inspection, has been changed, highlighting assessment level EZ only.
- The preferred values of rated voltages have been updated in conformance with the basic series of preferred values R5 and R10 given in ISO 3.
- Standard56 pagesEnglish and French languagesale 15% off
It is a supplementary document to the sectional specification and contains requirements for style and layout and minimum content of detail specifications. Detail specifications not complying with these requirements may not be considered as being in accordance with IEC specifications nor shall they so be described. In the preparation of detail specifications, the content of 1.4 of the sectional specification shall be taken into account. It constitutes a minor revision related to tables, figures and references.
- Standard16 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-3-1:2006 is a bilingual version and corresponds to the English version. It is a supplementary document to the sectional specification and contains requirements for style, layout and minimum content of detail specifications. Detail specifications not complying with these requirements may not be considered as being in accordance with IEC specifications nor shall they so be described. It cancels and replaces the first edition published in 1989 and constitutes a minor revision related to tables, figures and references.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-13-1:2006(E) is a supplementary document to the sectional specification and contains requirements for style and layout and minimum content of detail specifications. Detail specifications not complying with these requirements may not be considered as being in accordance with IEC specifications nor shall they so be described. The contents of the corrigendum of March 2009 have been included in this copy.
- Standard15 pagesEnglish languagesale 10% offe-Library read for1 day
blank detail specification is a supplementary document to the sectional specification and contains requirements for style and layout and minimum content of details specifications. Detail specifications not complying with these requirements may not be considered as being in accordance with IEC specifications nor shall they be so described.
- Standard16 pagesEnglish languagesale 10% offe-Library read for1 day
blank detail specification is a supplementary document to the sectional specification and contains requirements for style and layout and minimum content of details specifications. Detail specifications not complying with these requirements may not be considered as being in accordance with IEC specifications nor shall they be so described.
- Standard19 pagesEnglish languagesale 10% offe-Library read for1 day
blank detail specification is a supplementary document to the sectional specification and contains requirements for style and layout and minimum content of details specifications. Detail specifications not complying with these requirements may not be considered as being in accordance with IEC specifications nor shall they be so described.
- Standard16 pagesEnglish languagesale 10% offe-Library read for1 day
It is a supplementary document to the sectional specification and contains requirements for style and layout and minimum content of detail specifications. Detail specifications not complying with these requirements may not be considered as being in accordance with IEC specifications nor shall they so be described. In the preparation of detail specifications, the content of 1.4 of the sectional specification shall be taken into account. It constitutes a minor revision related to tables, figures and references.
- Standard13 pagesEnglish languagesale 15% off
IEC 60384-11:2008 applies to fixed direct current capacitors, for rated voltages not exceeding 6 300 V, using as dielectric a polyethylene-terephthalate film and electrodes of thin metal foils. For capacitors with rated voltages exceeding 1 000 V, additional tests and requirements may be specified in the detail specification. The capacitors covered by this standard are intended for use in electronic equipment. The object of this standard is to prescribe preferred ratings and characteristics and to select from IEC 60384-1, the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. Test severities and requirements prescribed in detail specifications referring to this sectional specification shall be of equal or higher performance level, because lower performance levels are not permitted. This third edition cancels and replaces the second edition published in 1988 and constitutes a minor revision related to tables, figures and references.
- Standard26 pagesEnglish languagesale 15% off
- Standard53 pagesEnglish and French languagesale 15% off
IEC 60384-3:2006 applies to surface mount tantalum solid electrolyte capacitors. These capacitors are primarily intended to be mounted directly onto substrates for hybrid circuits or onto printed boards. The following two styles are considered: Style 1 - protected capacitors; Style 2 - unprotected capacitors. This third edition cancels and replaces the second edition published in 1989 and constitutes a minor revision related to tables, figures and references This bilingual version, published in 2008-06, corresponds to the English version.
- Standard29 pagesEnglish languagesale 15% off
- Standard58 pagesEnglish and French languagesale 15% off
IEC 60384-3-1:2006 is a bilingual version and corresponds to the English version. It is a supplementary document to the sectional specification and contains requirements for style, layout and minimum content of detail specifications. Detail specifications not complying with these requirements may not be considered as being in accordance with IEC specifications nor shall they so be described. It cancels and replaces the first edition published in 1989 and constitutes a minor revision related to tables, figures and references.
- Standard14 pagesEnglish languagesale 15% off
- Standard29 pagesEnglish and French languagesale 15% off