This document specifies requirements for hip-joint replacement implants. With regard to safety, this document specifies requirements for intended performance, design attributes, materials, design evaluation, manufacture, sterilization, packaging, information supplied by the manufacturer and methods of test.
This document applies to both total and partial hip joint replacement implants. It applies to components made of metallic and non-metallic materials.
This document applies to a wide variety of hip replacement implants, but for some specific hip replacement implant types, some considerations, not specifically covered in this document, can be applicable. Further details are given in 7.2.1.2.
The requirements which are specified in this document are not intended to require the re-design or re-testing of implants which have been legally marketed and for which there is a history of sufficient and safe clinical use. For such implants, compliance with this document can be demonstrated by providing evidence of the implant’s sufficient and safe clinical use.

  • Standard
    41 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements for knee-joint replacement implants. Regarding safety, this document specifies requirements for intended performance, design attributes, materials, design evaluation, manufacture, sterilization, packaging, information supplied by the manufacturer and methods of test.
This document applies to both total and partial knee joint replacement implants. It applies to these replacements both with and without the replacement of the patella-femoral joint. It applies to components made of metallic and non-metallic materials.
This document applies to a wide variety of knee replacement implants, but for some specific knee replacement implant types, some considerations, not specifically covered in this document, can be applicable. Further details are given in 7.2.1.2.
The requirements which are specified in this document are not intended to require the re-design or re-testing of implants which have been legally marketed and for which there is a history of sufficient and safe clinical use. For such implants, compliance with this document can be demonstrated by providing evidence of the implant’s sufficient and safe clinical use.

  • Standard
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements for hip-joint replacement implants. With regard to safety, this document specifies requirements for intended performance, design attributes, materials, design evaluation, manufacture, sterilization, packaging, information supplied by the manufacturer and methods of test.
This document applies to both total and partial hip joint replacement implants. It applies to components made of metallic and non-metallic materials.
This document applies to a wide variety of hip replacement implants, but for some specific hip replacement implant types, some considerations, not specifically covered in this document, can be applicable. Further details are given in 7.2.1.2.
The requirements which are specified in this document are not intended to require the re-design or re-testing of implants which have been legally marketed and for which there is a history of sufficient and safe clinical use. For such implants, compliance with this document can be demonstrated by providing evidence of the implant’s sufficient and safe clinical use.

  • Standard
    41 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements for knee-joint replacement implants. Regarding safety, this document specifies requirements for intended performance, design attributes, materials, design evaluation, manufacture, sterilization, packaging, information supplied by the manufacturer and methods of test.
This document applies to both total and partial knee joint replacement implants. It applies to these replacements both with and without the replacement of the patella-femoral joint. It applies to components made of metallic and non-metallic materials.
This document applies to a wide variety of knee replacement implants, but for some specific knee replacement implant types, some considerations, not specifically covered in this document, can be applicable. Further details are given in 7.2.1.2.
The requirements which are specified in this document are not intended to require the re-design or re-testing of implants which have been legally marketed and for which there is a history of sufficient and safe clinical use. For such implants, compliance with this document can be demonstrated by providing evidence of the implant’s sufficient and safe clinical use.

  • Standard
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 455 specifies requirements for the evaluation of biological safety for medical gloves for single use. It gives requirements for labelling and the disclosure of information relevant to the test methods used.

  • Standard
    43 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2021-11-09-JO-Following roundtable discussion on 2021-11-09 between EC desk officer, CCMC and CEN/TC 102, it was agreed that the assessment at ENQ will be performed by the Medical Device EC desk officer for a finale assessment at Enquiry. If positive, CEN/TC 102 may decide to skip the Formal Vote and proceed to publication.

  • Amendment
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2021-11-09-JO-Following roundtable discussion on 2021-11-09 between EC desk officer, CCMC and CEN/TC 102, it was agreed that the assessment at ENQ will be performed by the Medical Device EC desk officer for a finale assessment at Enquiry. If positive, CEN/TC 102 may decide to skip the Formal Vote and proceed to publication.

  • Amendment
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 455 specifies requirements for the evaluation of biological safety for medical gloves for single use. It gives requirements for labelling and the disclosure of information relevant to the test methods used.

  • Standard
    43 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2021-11-09-JO-Following roundtable discussion on 2021-11-09 between EC desk officer, CCMC and CEN/TC 102, it was agreed that the assessment at ENQ will be performed by the Medical Device EC desk officer for a finale assessment at Enquiry. If positive, CEN/TC 102 may decide to skip the Formal Vote and proceed to publication.

  • Amendment
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2021-11-09-JO-Following roundtable discussion on 2021-11-09 between EC desk officer, CCMC and CEN/TC 102, it was agreed that the assessment at ENQ will be performed by the Medical Device EC desk officer for a finale assessment at Enquiry. If positive, CEN/TC 102 may decide to skip the Formal Vote and proceed to publication.

  • Amendment
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the procedure for the assessment of medical devices and their constituent materials with regard to their potential to induce skin sensitization.
This document includes:
—    details of in vivo skin sensitization test procedures;
—    key factors for the interpretation of the results.
NOTE      Instructions for the preparation of materials specifically in relation to the above tests are given in Annex A.

  • Standard
    60 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies particular requirements for active implantable medical devices intended to deliver a medicinal substance to site-specific locations within the human body, to provide basic assurance of safety for both patients and users. It amends and supplements ISO 14708-1:2014. The requirements of this document take priority over those of ISO 14708-1.
This document is applicable to active implantable medical devices intended to deliver medicinal substances to site-specific locations within the human body.
This document is also applicable to some non-implantable parts and accessories of the devices defined in Clause 3.
The tests that are specified in this document are type tests intended to be carried out on a sample of a device to show compliance and are not intended to be used for the routine testing of manufactured products.
NOTE       This document is not intended to apply to non-implantable infusion systems.

  • Standard
    68 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the method for the determination of free, chelated or complexed micronutrients and chelating and/or complexing agents present in compound inorganic micronutrient fertilizers.
This method applies to compound inorganic micronutrient fertilizers when micronutrients are chelated and/or complexed.
The method is based on the determination of the following specific parameters :
-   the water-soluble micronutrient concentration;
-   the fraction of chelated micronutrients in relation;
-   identification of chelating agents EDTA, DTPA, HEEDTA, IDHA, [S,S]–EDDS, [o,o] EDDHA, [o,o] EDDHMA, [o,p] EDDHA, HBED and EDDHSA;
-   the fraction of complexed micronutrients;
-   identification of complexing agents (lignosulfonates, heptagluconic acid (HGA)).
The method is based on
-   ICP (inductive coupled plasma) or FAAS (flame atomic absorption spectrometry) measurement of the concentration of water-soluble micronutrients according to EN 16963 or EN 16965 after extraction according to EN 16962;
-   LC (liquid chromatography) measurement of the chelating agents according to EN 15950, EN 13368-1, EN 13368-2, EN 13368-3, EN 15451, EN 15452;
and/or complexing agents according to EN 16109 and EN 16847;
-   determination of the concentration of chelated micronutrients by CEN/TS 17786-1 and/or CEN/TS 17786-2;
-   determination of the complexed micronutrients by EN 15962.
To avoid duplication of the analytical methods, CEN/TS 17786-2 describes the determination of micronutrients and the identification and determination of chelating agents.

  • Technical specification
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies terminology, principles and a process for risk management of medical devices, including software as a medical device and in vitro diagnostic medical devices. The process described in this document intends to assist manufacturers of medical devices to identify the hazards associated with the medical device, to estimate and evaluate the associated risks, to control these risks, and to monitor the effectiveness of the controls.
The requirements of this document are applicable to all phases of the life cycle of a medical device. The process described in this document applies to risks associated with a medical device, such as risks related to biocompatibility, data and systems security, electricity, moving parts, radiation, and usability.
The process described in this document can also be applied to products that are not necessarily medical devices in some jurisdictions and can also be used by others involved in the medical device life cycle.
This document does not apply to:
— decisions on the use of a medical device in the context of any particular clinical procedure; or
— business risk management.
This document requires manufacturers to establish objective criteria for risk acceptability but does not specify acceptable risk levels.
Risk management can be an integral part of a quality management system. However, this document does not require the manufacturer to have a quality management system in place.
NOTE Guidance on the application of this document can be found in ISO/TR 24971[9].

  • Amendment
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document is applicable to the basic safety and essential performance of an anaesthetic workstation for administering inhalational anaesthesia whilst continuously attended by a professional operator.
This document specifies particular requirements for a complete anaesthetic workstation and the following anaesthetic workstation components which, although considered as individual devices in their own right, may be utilized, in conjunction with other relevant anaesthetic workstation components, to form an anaesthetic workstation to a given specification:
anaesthetic gas delivery system;
anaesthetic breathing system;
anaesthetic gas scavenging system (AGSS);
anaesthetic vapour delivery system;
anaesthetic ventilator;
monitoring equipment;
alarm system;
protection device.
NOTE 1        Monitoring equipment, alarm systems and protection devices are summarized in Table AA.1.
An anaesthetic workstation supplied complete and its individual components are considered as ME equipment or ME systems with regard to the general standard.
NOTE 2        The applicability of this document is indicated in Table AA.2.
This document is also applicable to those accessories intended by their manufacturer to be connected to an anaesthetic workstation where the characteristics of those accessories can affect the basic safety and essential performance of the anaesthetic workstation.
If a clause or subclause is specifically intended to be applicable to anaesthetic workstation components or its accessories only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to an anaesthetic workstation and its individual components including accessories, as relevant.
Hazards inherent in the intended physiological function of an anaesthetic workstation and its individual components including accessories within the scope of this document are not covered by specific requirements in this document except in IEC 60601-1:2005+AMD1:2012+AMD2:2020, 7.2.13 and 8.4.1.
NOTE 3        See also IEC 60601-1:2005+AMD1:2012+AMD2:2020, 4.2.
This document is not applicable to any anaesthetic workstation intended for use with flammable anaesthetic agents, as determined by Annex BB.

  • Standard
    114 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a test method and the minimum requirements for fungicidal or yeasticidal activity of chemical disinfectant and antiseptic products that form a homogeneous, physically stable preparation when diluted with hard water, or - in the case of ready-to-use products - with water. Products can only be tested at a concentration of 80 % or less (97 % with a modified method for special cases) as some dilution is always produced by adding the test organisms and interfering substance.
This document applies to products that are used in the medical area in the fields of hygienic handrub, hygienic handwash, surgical handrub, surgical handwash, instrument disinfection by immersion, and surface disinfection by wiping, spraying, flooding or other means.
This document applies to areas and situations where disinfection or antisepsis is medically indicated. Such indications occur in patient care, for example:
-   in hospitals, in community medical facilities and in dental institutions;
-   in clinics of schools, of kindergartens and of nursing homes;
and can occur in the workplace and in the home. It can also include services such as laundries and kitchens supplying products directly for the patients.
NOTE 1   The method described is intended to determine the activity of commercial formulations or active substances under the conditions in which they are used.
NOTE 2   This method corresponds to a phase 2 step 1 test.
EN 14885 specifies in detail the relationship of the various tests to one another and to “use recommendations”.

  • Standard
    57 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the method for the determination of free, chelated or complexed micronutrients and chelating and/or complexing agents present in compound inorganic micronutrient fertilizers.
This method applies to compound inorganic micronutrient fertilizers when micronutrients are chelated and/or complexed.
The method is based on the determination of the following specific parameters :
-   the water-soluble micronutrient concentration;
-   the fraction of chelated micronutrients in relation;
-   identification of chelating agents EDTA, DTPA, HEEDTA, IDHA, [S,S]–EDDS, [o,o] EDDHA, [o,o] EDDHMA, [o,p] EDDHA, HBED and EDDHSA;
-   the fraction of complexed micronutrients;
-   identification of complexing agents (lignosulfonates, heptagluconic acid (HGA)).
The method is based on
-   ICP (inductive coupled plasma) or FAAS (flame atomic absorption spectrometry) measurement of the concentration of water-soluble micronutrients according to EN 16963 or EN 16965 after extraction according to EN 16962;
-   LC (liquid chromatography) measurement of the chelating agents according to EN 15950, EN 13368-1, EN 13368-2, EN 13368-3, EN 15451, EN 15452;
and/or complexing agents according to EN 16109 and EN 16847;
-   determination of the concentration of chelated micronutrients by CEN/TS 17786-1 and/or CEN/TS 17786-2;
-   determination of the complexed micronutrients by EN 15962.
To avoid duplication of the analytical methods, CEN/TS 17786-2 describes the determination of micronutrients and the identification and determination of chelating agents.

  • Technical specification
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies symbols used to express information supplied for a medical device. This document is applicable to symbols used in a broad spectrum of medical devices, that are available globally and need to meet different regulatory requirements.
These symbols can be used on the medical device itself, on its packaging or in the accompanying information. The requirements of this document are not intended to apply to symbols specified in other standards.

  • Standard
    63 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document provides general principles for the systematic evaluation of the potential and observed degradation of medical devices through the design and performance of in vitro degradation studies. Information obtained from these studies can be used in the biological evaluation described in the ISO 10993 series.
This document is applicable to both materials designed to degrade in the body as well as materials that are not intended to degrade.
This document is not applicable to:
a)   the evaluation of degradation which occurs by purely mechanical processes; methodologies for the production of this type of degradation product are described in specific product standards, where available;
NOTE    Purely mechanical degradation causes mostly particulate matter. Although this is excluded from the scope of this document, such degradation products can evoke a biological response and can undergo biological evaluation as described in other parts of ISO 10993.
b)   leachable components which are not degradation products;
c)   medical devices or components that do not contact the patient's body directly or indirectly.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements for the information to be provided by the medical device manufacturer for the processing of critical or semi-critical medical devices (i.e. a medical device that enters normally sterile parts of the human body or a medical device that comes into contact with mucous membranes or non-intact skin) or medical devices that are intended to be sterilized.
This includes information for processing prior to use or reuse of the medical device.
Processing instructions are not defined in this document. Rather, this document specifies requirements to assist manufacturers of medical devices in providing detailed processing instructions that consist of the following activities, where applicable:
a) initial treatment at the point of use;
b) preparation before cleaning;
c) cleaning;
d) disinfection;
e) drying;
f) inspection and maintenance;
g) packaging;
h) sterilization;
i) storage;
j) transportation.
This document excludes processing of the following:
—    non-critical medical devices unless they are intended to be sterilized;
—    textile devices used in patient draping systems or surgical clothing;
—    medical devices specified by the manufacturer for single use only and supplied ready for use.
NOTE       See ISO 17664-2:2021, Annex E, for further guidance on the application of the ISO 17664 series to a medical device.

  • Standard
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies terminology, principles and a process for risk management of medical devices, including software as a medical device and in vitro diagnostic medical devices. The process described in this document intends to assist manufacturers of medical devices to identify the hazards associated with the medical device, to estimate and evaluate the associated risks, to control these risks, and to monitor the effectiveness of the controls.
The requirements of this document are applicable to all phases of the life cycle of a medical device. The process described in this document applies to risks associated with a medical device, such as risks related to biocompatibility, data and systems security, electricity, moving parts, radiation, and usability.
The process described in this document can also be applied to products that are not necessarily medical devices in some jurisdictions and can also be used by others involved in the medical device life cycle.
This document does not apply to:
— decisions on the use of a medical device in the context of any particular clinical procedure; or
— business risk management.
This document requires manufacturers to establish objective criteria for risk acceptability but does not specify acceptable risk levels.
Risk management can be an integral part of a quality management system. However, this document does not require the manufacturer to have a quality management system in place.
NOTE Guidance on the application of this document can be found in ISO/TR 24971[9].

  • Amendment
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements for the characterization of a liquid chemical sterilizing agent and for the development, validation, process control and monitoring of sterilization by liquid chemical sterilizing agents of single-use medical devices comprising, in whole or in part, materials of animal origin.
This document covers the control of risks arising from contamination with bacteria and fungi by application of a liquid chemical sterilization process. Risks associated with other microorganisms can be assessed using other methods (see NOTE 1).
This document is not applicable to material of human origin.
This document does not describe methods for the validation of the inactivation of viruses and transmissible spongiform encephalopathy (TSE) agents (see NOTE 2 and NOTE 3).
This document does not describe methods for validation of the inactivation or elimination of protozoa and parasites.
The requirements for validation and routine control described in this document are only applicable to the defined sterilization process of a medical device, which is performed after the manufacturing process, and do not take account of the lethal effects of other bioburden reduction steps (see NOTE 4).
This document does not specify tests to establish the effects of any chosen sterilization process upon the fitness for use of the medical device (see NOTE 5).
This document does not cover the level of residual sterilizing agent within medical devices (see NOTE 6).
Guidance for the characterization of a liquid chemical sterilizing agent and for the development, validation, process control and monitoring of sterilization by liquid chemical sterilizing agents of single-use medical devices comprising, in whole or in part, materials of animal origin is provided in informative Annex A.
NOTE 1  The prior application of risk management principles to medical devices utilizing animal tissues, as described in ISO 22442-1 is important. ISO 18362 provides information on control of microbial risks during processing of cell-based health-care products.
NOTE 2  Liquid chemical sterilizing agents traditionally employed to sterilize animal tissues in medical devices might not be effective in inactivating the causative agents of TSE such as bovine spongiform encephalopathy (BSE), or scrapie. Satisfactory validation in accordance with this document does not necessarily demonstrate inactivation of infective agents of this type. Risk controls related to sourcing, collection and handling of animal materials are described in ISO 22442-2.
NOTE 3  The validation of the inactivation, elimination, or elimination and inactivation of viruses and TSE agents is described in ISO 22442-3.
NOTE 4  Manufacturing processes for medical devices containing animal tissues frequently include exposure to chemical agents which can significantly reduce the bioburden on the medical device. Following the manufacturing process, a medical device is exposed to a specified sterilization process.
NOTE 5  Such testing is a crucial part of the design and development of a medical device.
NOTE 6  ISO 10993-17 specifies a method to establish allowable limits for residues of sterilizing agents.
NOTE 7  Standards for quality management systems (see ISO 13485) can be used in the control of all stages of manufacture including the sterilization process.

  • Standard
    50 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements for and provides guidance on the specification, selection, qualification, bio-decontamination, validation, operation and control of isolator systems related to aseptic processing of health care products and processing of cell-based health care products.
This document does not specify requirements for restricted access barrier systems (RABS).
This document does not supersede or replace national regulatory requirements such as Good Manufacturing Practices (GMPs) and/or compendia requirements that pertain in particular to national or regional jurisdictions.
This document does not specify requirements for isolators used for sterility testing; however, some of the principles and information in this document could be applicable to this application.
This document does not define biosafety containment requirements.

  • Standard
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NOTE 1        There is guidance or rationale for this Clause contained in Clause A.2.
This document specifies the requirements for information supplied by the manufacturer for a medical device or by the manufacturer for an accessory, as defined in 3.1. This document includes the generally applicable requirements for identification and labels on a medical device or accessory, the packaging, marking of a medical device or accessory, and accompanying information. This document does not specify the means by which the information is to be supplied.
NOTE 2        Some authorities having jurisdiction impose different requirements for the identification, marking and documentation of a medical device or accessory.
Specific requirements of medical device product standards or group standards take precedence over requirements of this document.

  • Standard
    81 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    81 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements for the information to be provided by the medical device manufacturer for the processing of critical or semi-critical medical devices (i.e. a medical device that enters normally sterile parts of the human body or a medical device that comes into contact with mucous membranes or non-intact skin) or medical devices that are intended to be sterilized.
This includes information for processing prior to use or reuse of the medical device.
Processing instructions are not defined in this document. Rather, this document specifies requirements to assist manufacturers of medical devices in providing detailed processing instructions that consist of the following activities, where applicable:
a) initial treatment at the point of use;
b) preparation before cleaning;
c) cleaning;
d) disinfection;
e) drying;
f) inspection and maintenance;
g) packaging;
h) sterilization;
i) storage;
j) transportation.
This document excludes processing of the following:
—    non-critical medical devices unless they are intended to be sterilized;
—    textile devices used in patient draping systems or surgical clothing;
—    medical devices specified by the manufacturer for single use only and supplied ready for use.
NOTE       See ISO 17664-2:2021, Annex E, for further guidance on the application of the ISO 17664 series to a medical device.

  • Standard
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements for and provides guidance on the specification, selection, qualification, bio-decontamination, validation, operation and control of isolator systems related to aseptic processing of health care products and processing of cell-based health care products.
This document does not specify requirements for restricted access barrier systems (RABS).
This document does not supersede or replace national regulatory requirements such as Good Manufacturing Practices (GMPs) and/or compendia requirements that pertain in particular to national or regional jurisdictions.
This document does not specify requirements for isolators used for sterility testing; however, some of the principles and information in this document could be applicable to this application.
This document does not define biosafety containment requirements.

  • Standard
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies terminology, principles and a process for risk management of medical devices, including software as a medical device and in vitro diagnostic medical devices. The process described in this document intends to assist manufacturers of medical devices to identify the hazards associated with the medical device, to estimate and evaluate the associated risks, to control these risks, and to monitor the effectiveness of the controls.
The requirements of this document are applicable to all phases of the life cycle of a medical device. The process described in this document applies to risks associated with a medical device, such as risks related to biocompatibility, data and systems security, electricity, moving parts, radiation, and usability.
The process described in this document can also be applied to products that are not necessarily medical devices in some jurisdictions and can also be used by others involved in the medical device life cycle.
This document does not apply to:
—          decisions on the use of a medical device in the context of any particular clinical procedure; or
—          business risk management.
This document requires manufacturers to establish objective criteria for risk acceptability but does not specify acceptable risk levels.
Risk management can be an integral part of a quality management system. However, this document does not require the manufacturer to have a quality management system in place.
NOTE       Guidance on the application of this document can be found in ISO/TR 24971[9].

  • Standard
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard – translation
    44 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day

IEC 60601-1:2005+A1:2012, 1.1 is replaced by:
This document applies to the basic safety and essential performance of medical supply units, hereafter also referred to as ME equipment.
This document applies to medical supply units manufactured within a factory or assembled on site, including cabinetry and other enclosures, which incorporate patient care services.
NOTE 1 A party that assembles on site various components intended for patient care services into an enclosure is considered the manufacturer of the medical supply unit.
Hazards inherent in the intended function of ME equipment or ME systems within the scope of this document are not covered by specific requirements in this standard, except in of IEC 60601-1:2005+A1:2012, 7.2.13 and 8.4.1 (see 201.1.4).
NOTE 2 Refer to IEC 60601-1:2005+A1:2012, 4.2.

  • Draft
    41 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60601-1:2005+A1:2012, 1.1 is replaced by:
This document applies to the basic safety and essential performance of medical supply units, hereafter also referred to as ME equipment.
This document applies to medical supply units manufactured within a factory or assembled on site, including cabinetry and other enclosures, which incorporate patient care services.
NOTE 1 A party that assembles on site various components intended for patient care services into an enclosure is considered the manufacturer of the medical supply unit.
Hazards inherent in the intended function of ME equipment or ME systems within the scope of this document are not covered by specific requirements in this standard, except in of IEC 60601-1:2005+A1:2012, 7.2.13 and 8.4.1 (see 201.1.4).
NOTE 2 Refer to IEC 60601-1:2005+A1:2012, 4.2.

  • Draft
    41 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies general performance requirements for washer- disinfectors and their accessories that are intended to be used for cleaning and disinfection of re-usable medical devices and other articles used in the context of medical, dental, pharmaceutical and veterinary practice. It specifies performance requirements for cleaning and disinfection as well as the accessories which may be required to achieve the necessary performance.

  • Draft
    90 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements and the relevant tests for large steam sterilizers primarily used in health care for the sterilization of medical devices and their accessories contained in one or more sterilization modules. The test loads described in this European Standard are selected to represent the majority of loads (i.e. wrapped goods consisting of metal, rubber and porous materials) for the evaluation of general purpose steam sterilizers for medical devices. However, specific loads (e.g. heavy metal objects or long and/or narrow lumen) will require the use of other test loads.
This European Standard applies to steam sterilizers designed to accommodate at least one sterilization module or having a chamber volume of at least 60 l.
Large steam sterilizers can also be used during the commercial production of medical devices.
This European Standard does not specify requirements for equipment intended to use, contain or be exposed to flammable substances or substances which could cause combustion. This European Standard does not specify requirements for equipment intended to process biological waste or human tissues.
This European Standard does not describe a quality management system for the control of all stages of the manufacture of the sterilizer.
NOTE 1   Attention is drawn to the standards for quality management systems e.g. EN ISO 13485.
NOTE 2   Environmental aspects are addressed in Annex A.

  • Draft
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

20200402JO- link to MDD,IVD, AIMD and M/023,M/252,M/295 removed. These links are included in the previous published version  EN ISO 15223-1:2016 - JT003045

  • Draft
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a test method and the minimum requirements for the microbicidal activity of a specified disinfection process for the treatment of contaminated textile. This procedure is carried out by using a washing machine as specified in 5.3.2.18 and refers to the disinfection step without prewash. This procedure is not limited to certain types of textile. The suppliers' instructions are expected to be sufficient if they content the process parameters identified in the test (e.g. dosing disinfectant in whatever washing phase e.g. main wash, rinsing, disinfecting at 40 °C).
This document applies to areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities, and in dental institutions;
- in clinics of schools, of kindergartens, and of nursing homes;
and could occur in the workplace and in the home.
It could also include services such as laundries and kitchens supplying products directly for the patients.
The method described is intended to determine the activity of a product or product combination under the conditions in which they are used. This is a phase 2, step 2 laboratory test that simulates the conditions of application of the product.
EN 14885 specifies in detail the relationship of the various tests to one another and to “use recommendations”.

  • Standard
    48 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a test method and the minimum requirements for the microbicidal activity of a specified disinfection process for the treatment of contaminated textile. This procedure is carried out by using a washing machine as specified in 5.3.2.18 and refers to the disinfection step without prewash. This procedure is not limited to certain types of textile. The suppliers' instructions are expected to be sufficient if they content the process parameters identified in the test (e.g. dosing disinfectant in whatever washing phase e.g. main wash, rinsing, disinfecting at 40 °C).
This document applies to areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities, and in dental institutions;
- in clinics of schools, of kindergartens, and of nursing homes;
and could occur in the workplace and in the home.
It could also include services such as laundries and kitchens supplying products directly for the patients.
The method described is intended to determine the activity of a product or product combination under the conditions in which they are used. This is a phase 2, step 2 laboratory test that simulates the conditions of application of the product.
EN 14885 specifies in detail the relationship of the various tests to one another and to “use recommendations”.

  • Standard
    48 pages
    English language
    sale 10% off
    e-Library read for
    1 day