Communication systems for meters - Part 4: Wireless M-Bus communication

This European Standard specifies the requirements of parameters for the physical and the link layer for systems using radio to read remote meters. The primary focus is to use the Short Range Device (SRD) unlicensed telemetry bands. The standard encompasses systems for walk-by, drive-by and fixed installations. As a broad definition, this European Standard can be applied to various application layers.

Kommunikationssysteme für Zähler - Teil 4: Drahtlose M-Bus-Kommunikation

Systèmes de communication pour compteurs - Partie 4 : Communication sans fil M-Bus

La présente Norme européenne spécifie les exigences applicables aux paramètres de la couche physique et de la couche liaison associées aux systèmes de télérelevé de compteurs par radio. Elle est centrée essentiellement sur l’utilisation des bandes de télémesure libres pour dispositifs à courte portée (SRD). Elle traite à la fois des systèmes de relevé mobile à pied ou par véhicule et des installations fixes. La présente Norme européenne peut s’appliquer, par extension, à diverses couches application.

Komunikacijski sistemi za števce - 4. del: Brezžično komuniciranje po M-vodilu

Ta evropski standard določa zahteve parametrov za fizično plast in plast podatkovne povezave za sisteme, ki za daljinsko odbiranje števcev uporabljajo radijske valove. Osnovni cilj je uporaba nelicenciranih telemetričnih pasov za naprave kratkega dosega (SRD). Standard zajema sisteme za prehodne, prevozne in stacionarne naprave. Ta evropski standard se lahko kot široka definicija uporablja za različne aplikacijske nivoje.

General Information

Status
Withdrawn
Publication Date
30-Apr-2019
Withdrawal Date
16-Dec-2025
Current Stage
6060 - Definitive text made available (DAV) - Publishing
Start Date
01-May-2019
Due Date
15-Jun-2019
Completion Date
01-May-2019

Relations

Standard
EN 13757-4:2019 - BARVE
English language
100 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-julij-2019
Nadomešča:
SIST EN 13757-4:2013
Komunikacijski sistemi za števce - 4. del: Brezžično komuniciranje po M-vodilu
Communication systems for meters - Part 4: Wireless M-Bus communication
Kommunikationssysteme für Zähler und deren Fernablesung - Teil 4: Zählerauslesung
über Funk (Fernablesung von Zählern im SRD-Band)
Systèmes de communication pour compteurs - Partie 4 : Communication sans fil M-Bus
Ta slovenski standard je istoveten z: EN 13757-4:2019
ICS:
33.200 Daljinsko krmiljenje, daljinske Telecontrol. Telemetering
meritve (telemetrija)
35.100.10 Fizični sloj Physical layer
35.100.20 Podatkovni povezovalni sloj Data link layer
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EN 13757-4
EUROPEAN STANDARD
NORME EUROPÉENNE
May 2019
EUROPÄISCHE NORM
ICS 33.200; 35.100.10; 35.100.20 Supersedes EN 13757-4:2013
English Version
Communication systems for meters - Part 4: Wireless M-
Bus communication
Systèmes de communication pour compteurs - Partie 4 Kommunikationssysteme für Zähler - Teil 4: Drahtlose
: Communication sans fil M-Bus M-Bus-Kommunikation
This European Standard was approved by CEN on 25 February 2019.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2019 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 13757-4:2019 E
worldwide for CEN national Members.

Contents Page
European foreword . 6
Introduction . 7
1 Scope . 9
2 Normative references . 9
3 Terms and definitions . 10
4 Abbreviations and symbols . 11
4.1 Abbreviation . 11
4.2 Symbols . 12
5 General . 12
5.1 Modes of operation . 12
5.2 Meter communications types. 13
5.3 Performance Classes . 15
6 Mode S . 16
6.1 Channel properties . 16
6.2 Transmitter . 17
6.3 Receiver . 18
6.4 Data encoding and preamble . 19
6.4.1 Data encoding . 19
6.4.2 Order of transmission of the encoded data . 19
6.4.3 Preamble and synchronization pattern . 19
7 Mode T . 19
7.1 Channel properties . 19
7.2 Transmitter . 19
7.3 Receiver (T2 only) . 22
7.4 Data encoding and preamble . 22
7.4.1 General . 22
7.4.2 Meter transmit, “3 out of 6” data encoding . 22
7.4.3 Other Device transmit, Manchester encoding . 24
8 Mode R2 . 24
8.1 Channel properties . 24
8.2 Transmitter . 24
8.3 Receiver . 26
8.4 Data encoding and preamble . 26
8.4.1 Data encoding . 26
8.4.2 Order of transmission of the encoded data . 26
8.4.3 Preamble and synchronization pattern . 26
9 Mode C . 27
9.1 Channel properties . 27
9.2 Transmitter . 27
9.3 Receiver . 29
9.4 Data encoding and preamble . 29
9.4.1 Encoding . 29
9.4.2 Preamble and synchronization pattern . 29
10 Mode N . 30
10.1 Channel properties . 30
10.2 Physical link parameters . 31
10.3 Receiver sensitivity . 34
10.4 Data encoding and preamble . 34
10.4.1 Encoding . 34
10.4.2 Preamble and synchronization pattern . 34
11 Mode F . 35
11.1 Channel properties . 35
11.2 Physical link parameters . 35
11.3 Receiver sensitivity . 37
11.4 Data encoding and preamble . 37
11.4.1 Data Encoding . 37
11.4.2 Preamble and synchronization pattern . 37
12 Data Link Layer . 37
12.1 General . 37
12.2 Order of multi byte fields . 38
12.3 Frame format A . 38
12.4 Frame format B . 38
12.5 Field definitions . 39
12.5.1 General . 39
12.5.2 Multi byte fields . 39
12.5.3 Length field (L-Field) . 39
12.5.4 Control field (C-Field). 39
12.5.5 Manufacturer ID (M-field) . 41
12.5.6 Address (A-field) . 42
12.5.7 Cyclic redundancy check (CRC-field) . 42
12.5.8 Control information field (CI-field) . 42
12.6 Timing . 42
12.6.1 Timing for installation messages . 42
12.6.2 Synchronous transmissions of meter messages . 43
12.6.3 Access timing . 45
12.7 Repeated or duplicate messages . 46
12.8 Forward Error Correction (FEC) . 46
12.8.1 Overview . 46
12.8.2 Datagram structure. 46
12.8.3 FEC Algorithm . 47
13 Connection to higher protocol layers . 48
13.1 The Control Information Field (CI-field) . 48
13.2 CI-fields for the Extended Link Layer . 49
13.2.1 General . 49
13.2.2 CI-field = 8C . 50
h
13.2.3 CI-field = 8D . 50
h
13.2.4 CI-field = 8E . 50
h
13.2.5 CI-field = 8F . 51
h
13.2.6 CI-field = 86 . 51
h
13.2.7 Communication Control Field (CC-field) . 52
13.2.8 Access Number Field (ACC-field) . 54
13.2.9 Manufacturer ID 2 (M2-field). 54
13.2.10 Address 2 (A2-field) . 54
13.2.11 Session Number Field (SN-field) . 54
13.2.12 AES-128 Counter Mode Encryption . 55
13.2.13 Run Time Delay field (RTD-field) . 56
13.2.14 Reception Level field (RXL-field) . 56
13.2.15 Payload Checksum Field (PayloadCRC-field) . 58
13.3 CI-fields for the Transport Layer . 58
13.3.1 General . 58
13.3.2 Short Transport Layer . 59
13.3.3 Long Transport Layer . 59
14 Management functions for link control . 59
14.1 General . 59
14.2 Set Radio Parameters . 63
14.2.1 General . 63
14.2.2 Command . 63
14.2.3 Response . 67
14.3 Get Radio Parameters . 69
14.3.1 General . 69
14.3.2 Command . 69
14.3.3 Response . 69
14.4 Set limited radio parameters . 71
14.4.1 General . 71
14.4.2 Command . 71
14.4.3 Response . 72
14.5 Confirm Radio Parameters . 73
14.5.1 General . 73
14.5.2 Command . 73
14.5.3 Response: . 73
14.6 Set manufacturer specific parameters . 74
14.6.1 General . 74
14.6.2 Command . 74
14.6.3 Response . 75
Annex A (informative) Frequency allocation and band usage for the 868 MHz band . 76
Annex B (informative) Frequency allocation for the 169 MHz band . 77
B.1 Frequencies and allowed power levels . 77
B.2 Frequencies and allowed duty cycles . 77
Annex C (informative) Frame examples . 78
C.1 Example of a frame from a meter in mode S . 78
C.1.1 Conditions . 78
C.1.2 Block content . 78
C.1.3 Bit string . 79
C.2 Example of a frame from a meter in mode T1 . 80
C.2.1 Condition . 80
C.2.2 Block Content . 80
C.2.3 Bit string . 81
C.3 Example of a frame from a meter in mode C1 . 81
C.3.1 Conditions . 81
C.3.2 Block content . 82
C.3.3 Bit string . 82
Annex D (informative) Example of predictive reception of synchronous messages . 83
Annex E (informative) Timing diagrams . 84
Annex F (informative) Counter Mode Flow . 99
Bibliography . 100

European foreword
This document (EN 13757-4:2019) has been prepared by Technical Committee CEN/TC 294
“Communication systems for meters”, the secretariat of which is held by DIN.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by November 2019, and conflicting national standards
shall be withdrawn at the latest by November 2019.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN 13757-4:2013.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association.
The main changes since EN 13757-4:2013 are as follows:
— Referenced standards have been updated to the most recent versions;
— Mode N, in the 169 MHz band has been extended to cover more frequencies see Clause 10;
— New C-field function code (Send User Data – No reply) added see 12.5.4;
— Extended timing tolerances for synchronous transmission see 12.6.2;
— Optional Forward Error Correction in the Link Layer added see 12.8;
— CI field for selectable Extended Link Layer added see 13.2;
— Management functions for link control added see Clause 14.
The standard is not affected by any of the requirements in Directive 2004/22/EC as it only covers the
basic transmission of information from the meter to an external entity. The standard ensures that data
transmitted cannot be modified without it being detected. Confidentiality, integrity and authenticity are
provided by the capabilities specified in other parts of the EN 13757 series of standards. The standard
does not specify any of the metering capabilities of the meter nor the metrological capabilities of the
meter.
The standard enables encrypted transfer data either directly or as specified in other parts of the
EN 13757 series of standards. The encryption ensures the confidentiality of any personal data.
The standard provides capabilities of interoperability of meters as requested in M/441 which can be
used to improve the customer awareness of actual consumption.
According to the CEN-CENELEC Internal Regulations, the national standards organisations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria,
Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia,
France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta,
Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.
Introduction
This European Standard belongs to the EN 13757 series, which covers communication systems for
meters.
EN 13757-1 contains generic descriptions and a communication protocol.
EN 13757-2 contains a physical and a link layer for twisted pair based Meter-Bus (M-Bus).
EN 13757-3 describes the application layer protocols (often called M-Bus).
EN 13757-5 describes the wireless network used for repeating, relaying and routing for the different
modes of EN 13757-4.
EN 13757-6 describes a twisted pair local bus for short distance (Lo-Bus).
EN 13757-7 describes transport and security services.
These upper M-Bus protocol layers can be used with various physical layers and with link layers and
network layers, which support the transmission of variable length binary transparent messages.
Frequently, the physical and link layers of EN 13757-2 (twisted pair) and EN 13757-4 (wireless) as well
as EN 13757-5 (wireless with routing function) or the alternatives described in EN 13757-1 are used.
The different parts of this standard are complemented by CEN/TR 17167 that provides examples and
supplementary information related to EN 13757-2, EN 13757-3 and EN 13757-7.
These upper M-Bus protocol layers have been optimized for minimum battery consumption of meters,
especially for the case of wireless communication, to ensure long battery lifetimes of the meters.
Secondly, it is optimized for minimum message length to minimize the wireless channel occupancy and
hence the collision rate. Thirdly, it is optimized for minimum requirements towards the meter
processor regarding requirements of RAM size, code length and computational power.
This standard concentrates on the meter communication. The meter communicates with one (or
occasionally several) fixed or mobile communication partners which again might be part of a private or
public network. These further communication systems might use the same or other application layer
protocols, security, privacy, authentication, and management methods.
The European Committee for Standardization (CEN) draws attention to the fact that it is claimed that
compliance with this document may involve the use of a patent concerning Forward Error Correction
given in 12.8.
CEN takes no position concerning the evidence, validity and scope of this patent right.
The holder of this patent right has ensured CEN that he/she is willing to negotiate licences either free of
charge or under reasonable and non-discriminatory terms and conditions with applicants throughout
the world. In this respect, the statement of the holder of this patent right is registered with CEN.
Information may be obtained from:
Kamstrup A/S
Rasmus Søby Dupont, IP Manager, Technology
Industrivej 28, Stilling
8660 Skanderborg
Denmark
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights other than those identified above. CEN shall not be held responsible for identifying any or
all such patent rights.
CEN and CENELEC maintain online lists of patents relevant to their standards. Users are encouraged to
consult the lists for the most up to date information concerning patents
(ftp://ftp.cencenelec.eu/EN/IPR/Patents/IPRdeclaration.pdf).
1 Scope
This document specifies the requirements of parameters for the physical and the link layer for systems
using radio to remotely read meters. The primary focus is to use the Short Range Device (SRD)
unlicensed telemetry bands. The standard encompasses systems for walk-by, drive-by and fixed
installations. As a broad definition, this European Standard can be applied to various application layers.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 13757-1, Communication systems for meters - Part 1: Data exchange
EN 13757-2, Communication systems for meters - Part 2: Wired M-Bus communication
EN 13757-3:2018, Communication systems for meters - Part 3: Application protocols
EN 13757-5:2015, Communication systems for meters - Part 5: Wireless M-Bus relaying
EN 13757-7:2018, Communication systems for meters - Part 7: Transport and security services
EN 60870-5-1, Telecontrol equipment and systems - Part 5: Transmission protocols - Section 1:
Transmission frame formats (IEC 60870-5-1)
EN 60870-5-2, Telecontrol equipment and systems - Part 5: Transmission protocols - Section 2: Link
transmission procedures (IEC 60870-5-2)
ETSI EN 300-220-1, V3.1.1:2017-02, Short Range Devices (SRD) operating in the frequency range 25 MHz
to 1 000 MHz — Part 1: Technical characteristics and methods of measurement
ETSI EN 300-220-2, V3.2.1:2018-04, Short Range Devices (SRD) operating in the frequency range 25 MHz
to 1 000 MHz — Part 2: Harmonised Standard covering the essential requirements of article 3.2 of
Directive 2014/53/EU for non specific radio equipment
ETSI EN 300-220−4, V1.1.1:2017, Short Range Devices (SRD) operating in the frequency range 25 MHz to
1 000 MHz — Part 4: Harmonised Standard covering the essential requirements of article 3.2 of
Directive 2014/53/EU; Metering devices operating in designated band 169,400 MHz to 169,475 MHz
Draft ETSI EN 301 489−1, V2.2.0:2017, ElectroMagnetic Compatibility (EMC) standard for radio
equipment and services — Harmonised Standard covering the essential requirements of article 3.1(b) of
the Directive 2014/53/EU and the essential requirements of article 6 of the Directive 2014/30/EU —
Part 1: Common technical requirements
ETSI EN 301-489−3, Electromagnetic compatibility and Radio spectrum Matters (ERM) —
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services — Part 3: Specific
conditions for Short-Range Devices (SRD) operating on frequencies between 9 kHz and 246 GHz
CCSDS 131.0-B-2 (Consultative Committee for Space Data Systems (CCSDS)), August 2011, Recommended
standard for TM Synchronization and Channel Coding, Issue 2
ERC/REC 70-03 relating to the use of short range devices (SRD), issued by the European Conference of
Postal and Telecommunications Administrations (CEPT), Electronics Communications Committee on
2018-10-05
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— IEC Electropedia: available at http://www.electropedia.org/
— ISO Online browsing platform: available at http://www.iso.org/obp
3.1
BER
bit error rate
3.2
FEC
Forward Error Correction
3.3
frame
unit of transmission at the Data Link Layer
3.4
FSK
frequency shift keying
3.5
GFSK
gaussian frequency shift keying
3.6
individual transmission interval
exact time between two subsequent synchronous or periodical transmissions which changes with each
transmission
3.7
LSB
least significant byte
3.8
LSBit
least significant bit
3.9
message
set of data at the Application Layer
3.10
MSB
most significant byte
3.11
MSBit
most significant bit
3.12
nominal transmission interval
average individual transmission interval between all synchronous or periodical messages (new, old or
no data content) for wireless meters
3.13
NRZ
non-return-to-zero
3.14
other device
end device exchanging information with a meter
Note 1 to entry: A repeater is not an Other Device, as it is not exchanging information but just passing it on. A
communications controller (gateway) is an Other Device. A physical meter may take this role if supporting
additional network functions.
3.15
PER
packet error rate
3.16
PN9
nine bit pseudo-random pattern
Note 1 to entry: The PN9 needs to be designed according to ITU-T Rec. O.150.
4 Abbreviations and symbols
4.1 Abbreviation
CI Control Information Field
Ident no. Identification number (serial number) (part of meter address)
Manuf. Manufacturer acronym (part of meter address)
Ver. Version (part of meter address)
Device Type Device type (part of meter address)
ACC Access number (refer to EN 13757-7)
STS Status (refer to EN 13757-7)
Conf.Field Configuration Field (refer to EN 13757-7)
M-2-O Meter to other device (transmission direction)
O-2-M Other device to meter (transmission direction)
min. minimum value
typ. typical value
max. maximum value
RFU Reserved for Future Use
4.2 Symbols
Hexadecimal notation is designated by a following “ ”.
h
Binary numbers are designated by a following “ ”.
b
Decimal numbers have no suffix.
5 General
5.1 Modes of operation
The “meters” may communicate with “other” system components, for example mobile readout devices,
stationary receivers, data collectors, multi-utility concentrators or system network components. Such
devices are in this document named “Other Device”. For the meter side, it is assumed that the
communication function will work without any operator’s intervention or need for battery replacement
over the full lifetime of the radio part of the meter. Other components such as the mobile readout or
stationary equipment may have a shorter battery lifetime or require an external power supply as
dictated by the technical parameters and use.
Several different modes of operation are defined for the communication with the meter. Many of the
physical and link layer parameters of these different modes are identical, allowing the use of common
hardware and software. However, due to the operational and technical requirements of these modes
some parameters will differ.
The name of a mode is specified by a letter and a number. The letter specifies a mode and the number
specifies whether the modes supports unidirectional (= 1) or bidirectional (= 2) data transfer.
a) “Stationary mode”, mode S is intended for unidirectional or bidirectional communications between
the meter and a stationary or mobile device. A special transmit only sub-mode S1 is optimized for
stationary battery operated devices with a long header and the sub-mode S1-m is specialized for
mobile receivers.
b) “Frequent transmit mode”, mode T. In this mode, the meter transmits a very short frame (typically
3 ms to 8 ms) every few seconds, thus allowing walk-by and/or drive-by readout.
Transmit only sub-mode T1. It is the minimal transmission of a meter ID plus a readout value,
which is sent periodically.
The bidirectional sub-mode T2 transmits frequently a short frame containing at least its ID and
then waits for a very short period after each transmission for the reception of a response. The
reception of a response will open a bidirectional communication channel. Alternatively, the initial
frame contains the readout value as well, and the response is a reverse channel only used for
special services.
c) “Frequent receive mode”, mode R. In this mode only R2 is relevant, as R1 makes no sense. The
meter listens every few seconds for the reception of a wakeup message from a mobile transceiver.
After receiving such a wakeup, the device will prepare for a few seconds of communication dialogue
with the initiating transceiver. In this mode a “multi-channel receive mode” allows the
simultaneous readout of several meters, each one operating on a different frequency channel. This
mode is as well applicable to stationary Other Devices.
d) “Compact Mode” mode C. This mode is similar to mode T but it allows for transmission of more data
within the same energy budget and with the same duty cycle. It supports the sub-modes C1 and C2
for unidirectional and bidirectional devices. It is suitable for walk-by and/or drive-by readout. The
common reception of mode T and mode C frames with a single receiver is possible.
e) “Narrowband VHF”, mode N. Optimized for narrowband operation in the 169 MHz frequency band,
allocated for meter reading and a few other services. The range of sub-modes can be extended
using repeaters. Sub-band A is intended for, but not limited to, long range secondary
communication using multi-hop repeaters.
f) “Frequent receive and transmit mode”, mode F. Used in the 433 MHz frequency band for long range
communications. In the bidirectional sub-modes F2-m, the meter listens every few seconds for the
reception of a wake up message from a stationary or mobile transceiver. After receiving such a
wake up message, the device prepares for a few seconds of communication dialogue with the
initiating transceiver. The bidirectional sub-mode F2 transmits a frame and waits for a short period
for the reception of a response. The response will open for bidirectional communication.
Meters or other communication devices may support one, multiple or all of the described modes.
NOTE Additional modes, supporting repeating and routing of data, are specified in EN 13757-5.
The detailed handling of broadcast and multicast transmissions is not specified in this standard. The
transmission shall be interpreted as multicast if no Extended Link Layer or Transport Layer is used.
5.2 Meter communications types
Table 1 describes the key features of each mode and sub-mode.
Table 1 — Meter communication types
Modes WAY Typical use Chip- Maximum Data coding Description
and rate a and header
duty cycle
sub-
kcps
modes
S1 1 Transmit only 32,768 b Manchester Transmit only; transmits a
0,02 %
meter for and long number of times per day to a
stationary header stationary receiving point.
receiving Transmits in the 1 % duty cycle
readout frequency band. Due to long
header, it is suitable also for
battery economized receiver.
S1-m 1 Transmit only 32,768 b Manchester Transmit only; transmits with a
0,02 %
meter for mobile and short duty cycle limitation of 0,02 % per
or stationary header hour to a mobile or stationary
readout receiving point. Transmits in a 1 %
duty cycle frequency band.
Requires a continuously enabled
receiver.
S2 2 All meter types. 32,768 1 % Manchester Meter unit with a receiver either
Stationary and short continuously enabled or
readout header or synchronized requiring no
optionally extended preamble for wakeup.
long header Also usable for node transponders
or concentrators. A long header is
optional.
T1 1 Frequent 100 0,1 % 3 to 6 and Transmit only with short data
transmission short header bursts typically 3 ms to 8 ms every
(short frame few seconds, operates in a 0,1 %
meters) duty cycle frequency band.
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...

Frequently Asked Questions

EN 13757-4:2019 is a standard published by the European Committee for Standardization (CEN). Its full title is "Communication systems for meters - Part 4: Wireless M-Bus communication". This standard covers: This European Standard specifies the requirements of parameters for the physical and the link layer for systems using radio to read remote meters. The primary focus is to use the Short Range Device (SRD) unlicensed telemetry bands. The standard encompasses systems for walk-by, drive-by and fixed installations. As a broad definition, this European Standard can be applied to various application layers.

This European Standard specifies the requirements of parameters for the physical and the link layer for systems using radio to read remote meters. The primary focus is to use the Short Range Device (SRD) unlicensed telemetry bands. The standard encompasses systems for walk-by, drive-by and fixed installations. As a broad definition, this European Standard can be applied to various application layers.

EN 13757-4:2019 is classified under the following ICS (International Classification for Standards) categories: 33.200 - Telecontrol. Telemetering; 35.100.10 - Physical layer; 35.100.20 - Data link layer. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 13757-4:2019 has the following relationships with other standards: It is inter standard links to EN 13757-4:2013, EN 13757-4:2025. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 13757-4:2019 is associated with the following European legislation: Standardization Mandates: M/441, M/490. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

You can purchase EN 13757-4:2019 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CEN standards.

The standard EN 13757-4:2019 outlines critical specifications for communication systems utilized in meter reading through wireless M-Bus communication. This European Standard concentrates on defining the parameters that govern the physical and link layer aspects of these systems, which primarily leverage Short Range Device (SRD) unlicensed telemetry bands. One of the notable strengths of EN 13757-4:2019 is its comprehensive coverage of various operational scenarios including walk-by, drive-by, and fixed installations, thereby enhancing its applicability across different implementations of remote meter reading. This flexibility positions the standard as a cornerstone within the domain of wireless communication for utility meters, catering to diverse user needs and facilitating easier adaptation to distinct operational environments. Moreover, the relevant focus on unlicensed bands simplifies regulatory compliance and encourages innovation in meter reading technologies, promoting wider adoption. The framework provided by this standard fosters interoperability among various meter types and communication devices, which is crucial in creating efficient and cohesive smart meter networks. With its broad applicability across multiple application layers, the EN 13757-4:2019 standard not only sets the groundwork for effective communication between meters and data collection systems but also plays a significant role in advancing the transition towards smart cities and optimized resource management. Thus, the relevance of this standard cannot be understated, as it addresses both immediate operational requirements and future advancements within the field of wireless communication for meter reading.

SIST EN 13757-4:2019 표준 문서는 원거리 미터를 읽기 위해 라디오를 사용하는 시스템에 대한 물리적 및 링크 계층의 요구 사항을 명확히 규정하고 있습니다. 이 표준은 특히 비면허 단거리 장치(SRD) 텔레메트리 대역의 활용에 중점을 두고 있으며, 이는 다양한 환경에서의 신뢰할 수 있는 데이터 통신을 보장합니다. 이 표준의 강점 중 하나는 워크바이, 드라이브바이 및 고정 설치 시스템을 모두 포함하는 넓은 적용 범위를 제공한다는 점입니다. 이러한 포괄적인 접근은 다양한 산업 분야에서의 효율성을 높이며, 특히 스마트 미터링 솔루션의 개발과 구현에서 필수적인 기준을 마련합니다. 또한, EN 13757-4:2019 표준은 관련 기술 표준과의 상호 운용성을 확보하도록 설계되어 있어, 사용자와 공급자가 원활하게 통신 프로토콜을 사용할 수 있게 합니다. 이는 전 세계적으로 에너지 및 자원 관리의 최적화를 추구하는 데 매우 중요한 요소입니다. 결론적으로, SIST EN 13757-4:2019 표준은 무선 M-Bus 통신을 통한 미터링 시스템의 발전을 위한 기초를 제공하며, 다양한 응용 프로그램 분야에서 그 유용성과 신뢰성을 입증합니다.

EN 13757-4:2019は、無線M-Bus通信に関連するメーター用の通信システムに関する欧州標準を提供しており、その範囲は非常に広範です。この標準は、リモートメーターを読み取るためのシステムにおける物理層およびリンク層に関する要求事項を明確に定義しています。特に、Short Range Device (SRD) の無 Licenseテレメトリーバンドを利用することに重点を置いています。 この標準の強みは、多様なシステムに対応できる柔軟性にあります。歩行者による読み取り(walk-by)、車両による読み取り(drive-by)、または固定設置型のシステムにまで適用可能であり、様々な使用シーンにおいて効果的に活用できます。このように、EN 13757-4:2019は、多様なメーター通信のニーズを満たすための基盤を提供しています。 さらに、この標準は、電力消費や通信の効率性を向上させるためのガイドラインを提示しており、持続可能な通信システムの実現にも寄与します。そのため、エネルギー管理やリソースの最適化を重視する現代社会において、その関連性は非常に高いと言えます。全体として、SIST EN 13757-4:2019は、無線通信を用いたリモートメーター読み取りにおける標準化の重要な一翼を担っています。