EN ISO 15011-1:2002
(Main)Health and safety in welding and allied processes - Laboratory method for sampling fume and gases generated by arc welding - Part 1: Determination of emission rate and sampling for analysis of particulate fume (ISO 15011-1:2002)
Health and safety in welding and allied processes - Laboratory method for sampling fume and gases generated by arc welding - Part 1: Determination of emission rate and sampling for analysis of particulate fume (ISO 15011-1:2002)
This part of European Standard describes a method for the determination of particulate fume emission rate from arc welding processes using a fume box technique. It defines a method of sampling particulate fume for chemical analysis and suggests possible analytical techniques.
Arbeits- und Gesundheitsschutz beim Schweißen und bei verwandten Verfahren - Laborverfahren zum Sammeln von Rauch und Gasen, die beim Lichtbogenschweißen erzeugt werden - Teil 1: Bestimmung der Emissionsrate und Probenahme zur Analyse von partikelförmigem Rauch (ISO 15011-1:2002)
Dieser Teil der Europäischen Norm beschreibt ein Verfahren zur Bestimmung der Emissionsrate von partikelförmigem Rauch bei Lichtbogenschweißverfahren unter Anwendung einer Rauchkammertechnik. Es wird ein Verfahren zur Probenahme von partikelförmigem Rauch für die chemische Analyse definiert und mögliche analytische Techniken vorgeschlagen.
Hygiène et sécurité en soudage et techniques connexes - Méthode de laboratoire d'échantillonnage des fumées et des gaz émis par le soudage à l'arc - Partie 1: Détermination du taux d'émission et échantillonnage pour l'analyse des poussières (ISO 15011-1:2002)
Cette partie de la norme européenne décrit une méthode utilisant la technique de la chambre de prélèvement pour la détermination du taux d'émission des fumées particulaires émises par les procédés de soudage à l'arc. Elle définit une méthode pour l'échantillonnage des fumées particulaires en vue de l'analyse chimique et suggère des techniques analytiques.
Zdravje in varnost pri varjenju in sorodnih postopkih - Laboratorijska metoda za vzorčenje dima in plinov, nastalih pri obločnem varjenju - 1. del: Določevanje emisij in vzorčenje za analizo prahu (ISO 15011-1:2002)
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN ISO 15011-1:2003
01-maj-2003
=GUDYMHLQYDUQRVWSULYDUMHQMXLQVRURGQLKSRVWRSNLK/DERUDWRULMVNDPHWRGD]D
Y]RUþHQMHGLPDLQSOLQRYQDVWDOLKSULREORþQHPYDUMHQMXGHO'RORþHYDQMH
HPLVLMLQY]RUþHQMH]DDQDOL]RSUDKX,62
Health and safety in welding and allied processes - Laboratory method for sampling fume
and gases generated by arc welding - Part 1: Determination of emission rate and
sampling for analysis of particulate fume (ISO 15011-1:2002)
Arbeits- und Gesundheitsschutz beim Schweißen und bei verwandten Verfahren -
Laborverfahren zum Sammeln von Rauch und Gasen, die beim Lichtbogenschweißen
erzeugt werden - Teil 1: Bestimmung der Emissionsrate und Probenahme zur Analyse
von partikelförmigem Rauch (ISO 15011-1:2002)
Hygiene et sécurité en soudage et techniques connexes - Méthode de laboratoire
d'échantillonnage des fumées et des gaz émis par le soudage a l'arc - Partie 1:
Détermination du taux d'émission et échantillonnage pour l'analyse des poussieres (ISO
15011-1:2002)
Ta slovenski standard je istoveten z: EN ISO 15011-1:2002
ICS:
13.100 Varnost pri delu. Industrijska Occupational safety.
higiena Industrial hygiene
25.160.10 Varilni postopki in varjenje Welding processes
SIST EN ISO 15011-1:2003 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN ISO 15011-1:2003
---------------------- Page: 2 ----------------------
SIST EN ISO 15011-1:2003
EUROPEAN STANDARD
EN ISO 15011-1
NORME EUROPÉENNE
EUROPÄISCHE NORM
April 2002
ICS 13.100; 25.160.01
English version
Health and safety in welding and allied processes - Laboratory
method for sampling fume and gases generated by arc welding -
Part 1: Determination of emission rate and sampling for analysis
of particulate fume (ISO 15011-1:2002)
Hygiène et sécurité en soudage et techniques connexes - Arbeits- und Gesundheitsschutz beim Schweißen und bei
Méthode de laboratoire d'échantillonnage des fumées et verwandten Verfahren - Laborverfahren zum Sammeln von
des gaz émis par le soudage à l'arc - Partie 1: Rauch und Gasen, die beim Lichtbogenschweißen erzeugt
Détermination du taux d'émission et échantillonnage pour werden - Teil 1: Bestimmung der Emissionsrate und
l'analyse des poussières (ISO 15011-1:2002) Probenahme zur Analyse von partikelförmigem Rauch (ISO
15011-1:2002)
This European Standard was approved by CEN on 20 April 2001.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the official
versions.
CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,
Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36 B-1050 Brussels
© 2002 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 15011-1:2002 E
worldwide for CEN national Members.
---------------------- Page: 3 ----------------------
SIST EN ISO 15011-1:2003
EN ISO 15011-1:2002 (E)
Contents
page
Foreword.3
1 Scope .4
2 Terms and definitions .4
3 Test equipment .4
3.1 Fume box.4
3.2 Filters .5
3.3 Pump .5
3.4 Measuring equipment .5
4 Test pieces .5
5 Consumable .5
6 Procedure.6
6.1 Principle.6
6.2 Test sequence.6
6.3 Precautions .6
6.4 Welding parameters .6
6.5 Duration of the test.6
7 Interpretation of results .7
7.1 Number of tests .7
7.2 Calculation of fume emission rate.7
7.3 Analysis.7
7.4 Recording of test data and presentation of results .7
Annex A (informative) Possible designs of fume boxes designed for manual metal arc welding, MIG-
welding and MAG-welding .8
A.1 Design 1.8
A.2 Design 2.10
Annex B (informative) Test report.11
Annex C (informative) Recommended analytical analysis.12
Annex D (informative) Extraction method of total hexavalent chromium found in welding particulate matter13
2
---------------------- Page: 4 ----------------------
SIST EN ISO 15011-1:2003
EN ISO 15011-1:2002 (E)
Foreword
This document (EN ISO 15011-1:2002) has been prepared by Technical Committee CEN/TC 121 "Welding", the
secretariat of which is held by DS, in collaboration with Technical Committee ISO/TC 44 "Welding and allied
processes".
This European Standard shall be given the status of a national standard, either by publication of an identical text or
by endorsement, at the latest by October 2002, and conflicting national standards shall be withdrawn at the latest
by October 2002.
This standard consists of the following parts:
Part 1: Determination of emission rate and sampling for analysis of particulate fume;
Part 2: Determination of emission rates of gases and vapours, except ozone;
Part 3: Determination of ozone concentration using fixed point measurements.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard : Austria, Belgium, Czech Republic, Denmark, Finland,
France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain,
Sweden, Switzerland and the United Kingdom.
3
---------------------- Page: 5 ----------------------
SIST EN ISO 15011-1:2003
EN ISO 15011-1:2002 (E)
Introduction
Welding and allied processes produce particulate fume and gaseous by-products which may be harmful to human
health. A knowledge of the quantity of particulate fume and gases generated and the composition of the particulate
fume may be useful for occupational hygienists in accessing workplace atmospheres. Emission rates cannot be
directly related to fume concentrations existing in a welder's breathing zone, but processes with low emission rates
are supposed to produce less fume concentration compared with high emission rates for the same welding
condition.
The laboratory procedure described in Part 1 of this standard is used to determine emission rate of particulate fume
generated by the arc welding and provides a method of sampling the fume for chemical analysis. The emission rate
and composition of particulate fume depend on the welding process, welding parameters, workpiece surface,
coatings etc.
With the aid of a fume box in an un-polluted atmosphere, the total particulate fume generated during welding is
collected and sampled on a filter in order to determine the emission rate and/or chemical composition.
1 Scope
This European standard describes a method for the determination of the particulate fume emission rate from arc
welding processes using a fume box technique. It defines a method of sampling particulate fume for chemical
analysis and suggests possible analytical techniques in order to characterize fumes emitted by consumable during
welding.
2 Terms and definitions
For the purposes of this European Standard, the following terms and definitions apply.
2.1
fume box
a closed or semi-closed ventilated chamber used for sampling and determination (emission rate and composition)
of fume and gases in welding and allied processes
2.2
test piece
piece of metal on which the welding process is performed
2.3
arc time
arc time starts from arc initiation and stops immediately as the arc is extinguished
3 Test equipment
3.1 Fume box
The fume box should consist of a top section containing a filter, a welding chamber and a chamber base. The
welding chamber shall be large enough to allow complete capture of the emitted fume. The fume box should be
designed to reduce deposition of welding fume onto the internal box surface. Examples of possible arrangements
are described in annex A, as an example. Other appropriate fume box designs may be used.
4
---------------------- Page: 6 ----------------------
SIST EN ISO 15011-1:2003
EN ISO 15011-1:2002 (E)
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.