Air quality - Stationary source emissions - Determination of total mercury: automated measuring systems

This European Standard specifies specific requirements on automated measuring systems (AMS) for monitoring of total mercury. It is derived from EN 14181, which is the general document on the quality assurance of AMS. It is only applicable in conjunction with EN 14181.
This European Standard sets specific requirements for the quality assurance levels and annual surveillance test as specified in EN 14181, for mercury AMS used for proving that the mercury emissions from a source are compliant with emission limits below 0,5 mg/m3  ) (standard conditions) in ducted gaseous streams. This European Standard is applicable by direct correlation with the standard reference method (SRM) described in EN 13211.
This European Standard is primarily developed for emissions from waste incinerators. From a technical point of view, it may be applied to other processes, for which measurement at an emission limit is required with defined uncertainty.

Luftbeschaffenheit - Emissionen aus stationären Quellen - Bestimmung der Gesamtquecksilber-Konzentration: Automatische Messeinrichtungen

Dieses Dokument legt spezielle Anforderungen an automatische Messeinrichtungen (AMS) zur Überwachung
von Gesamtquecksilber-Konzentrationen fest. Es leitet sich aus der EN 14181 her, dem allgemeinen Doku-ment
über Qualitätssicherung automatischer Messeinrichtungen. Es ist nur in Verbindung mit EN 14181 an-wendbar.
Dieses Dokument legt spezielle Anforderungen an automatische Quecksilbermesseinrichtungen für die Quali-tätssicherungsstufen
und die jährliche Funktionsprüfung nach EN 14181 fest. Damit kann nachgewiesen wer-den,
dass die Quecksilberemissionen aus einer Quelle die Emissionsgrenzwerte unter 0,5 mg/m³ 1) (Normbe-dingungen)
in geführten Gasströmen einhalten. Dieses Dokument ist in Verbindung mit dem in EN 13211 be-schriebenen
Standardreferenzverfahren (SRM) anwendbar.
Dieses Dokument ist in erster Linie für Emissionen aus Abfallverbrennungsanlagen erarbeitet worden. Aus
technischer Sicht darf sie auf andere Prozesse angewandt werden, für die eine Messung an einem Emis-
sionsgrenzwert mit gegebener Messunsicherheit erforderlich ist.

Qualité de l'air - Emissions de sources fixes - Détermination de la concentration en mercure total : systèmes automatiques de mesure

La présente Norme européenne fixe des exigences spécifiques pour les systèmes automatiques de mesure (AMS) utilisés pour le contrôle du mercure total. Elle est dérivée de l’EN 14181 qui est le document général relatif à l’assurance qualité des AMS. Elle n’est applicable qu’en association avec l’EN 14181.
La présente Norme européenne fixe des exigences spécifiques relatives aux niveaux d’assurance qualité et aux tests annuels de surveillance spécifiés dans l’EN 14181, pour les AMS du mercure utilisés pour démontrer que les émissions de mercure à partir d’une source sont conformes aux limites d’émission entre 0,03 mg/m3 et 0,5 mg/m3  ) (conditions normalisées) dans les courants gazeux à la sortie de conduits et cheminées. La présente Norme européenne est applicable par corrélation directe avec la méthode de référence normalisée (SRM) décrite dans l’EN 13211.
La présente Norme européenne est avant tout élaborée pour les émissions produites par les incinérateurs de déchets. D’un point de vue technique, elle peut être appliquée à d’autres processus pour lesquels il est requis d’effectuer un mesurage à une limite d’émission avec une incertitude définie.

Kakovost zraka – Emisije nepremičnih virov – Določevanje celotnega živega srebra: avtomatski merilni sistemi

General Information

Status
Withdrawn
Publication Date
20-Dec-2005
Withdrawal Date
13-Dec-2022
Technical Committee
Drafting Committee
Current Stage
9960 - Withdrawal effective - Withdrawal
Completion Date
14-Dec-2022

Relations

Buy Standard

Standard
EN 14884:2006
English language
18 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 14884:2006
01-maj-2006
.DNRYRVW]UDND±(PLVLMHQHSUHPLþQLKYLURY±'RORþHYDQMHFHORWQHJDåLYHJD
VUHEUDDYWRPDWVNLPHULOQLVLVWHPL
Air quality - Stationary source emissions - Determination of total mercury: automated
measuring systems
Luftbeschaffenheit - Emissionen aus stationären Quellen - Bestimmung der
Gesamtquecksilber-Konzentration: Automatische Messeinrichtungen
Qualité de l'air - Emissions de sources fixes - Détermination de la concentration en
mercure total : systemes automatiques de mesure
Ta slovenski standard je istoveten z: EN 14884:2005
ICS:
13.040.40 (PLVLMHQHSUHPLþQLKYLURY Stationary source emissions
SIST EN 14884:2006 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 14884:2006

---------------------- Page: 2 ----------------------

SIST EN 14884:2006
EUROPEAN STANDARD
EN 14884
NORME EUROPÉENNE
EUROPÄISCHE NORM
December 2005
ICS 13.040.40

English Version
Air quality - Stationary source emissions - Determination of total
mercury: automated measuring systems
Qualité de l'air - Emissions de sources fixes - Luftbeschaffenheit - Emissionen aus stationären Quellen -
Détermination de la concentration en mercure totale: Bestimmung der Gesamtquecksilber-Konzentration:
systèmes automatiques de mesure Automatische Messeinrichtungen
This European Standard was approved by CEN on 28 November 2005.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the Central Secretariat or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official
versions.
CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,
Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia,
Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36  B-1050 Brussels
© 2005 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 14884:2005: E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------

SIST EN 14884:2006
EN 14884:2005 (E)
Contents Page
Foreword .3
Introduction.4
1 Scope .5
2 Normative references .5
3 Terms and definitions.5
4 Principle.6
5 AMS performance criteria for QAL 1 .6
6 AMS location .7
7 Calibration and validation of the AMS (QAL2) .7
7.1 General .7
7.2 Calibration procedure.7
7.2.1 Parallel measurements with SRM .7

7.2.2 Automatic recording of AMS output signals.8
7.3 Establishing the calibration function .8
8 Ongoing quality assurance durin
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.