EN 61116:1994
(Main)Electromechanical equipment guide for small hydroelectric installations
Electromechanical equipment guide for small hydroelectric installations
Provides the future purchaser with information allowing him to prepare the required documents, from the call for tenders up to acceptance tests and operation of electromechanical equipment. Applies to installations having outputs of less than 5 MW and turbines with diameters less than 3 m.
Anleitung für die elektromechanische Ausrüstung von kleinen Wasserkraftanlagen
Guide pour l'équipement électromécanique des petits aménagements hydro-électriques
Donne au futur acquéreur des renseignements lui permettant de préparer les documents nécessaires depuis l'appel d'offres jusqu'à la réception et l'exploitation des équipements électromécaniques. S'applique aux aménagements de puissance unitaire inférieure à 5 MW avec des turbines dont le diamètre n'excède pas 3 m.
Vodilo za elektromehansko opremo malih hidroelektrarn (IEC 61116:1992)
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-marec-2001
1DGRPHãþD
SIST IEC 61116:1999
Vodilo za elektromehansko opremo malih hidroelektrarn (IEC 61116:1992)
Electromechanical equipment guide for small hydroelectric installations
Anleitung für die elektromechanische Ausrüstung von kleinen Wasserkraftanlagen
Guide pour l'équipement électromécanique des petits aménagements hydro-électriques
Ta slovenski standard je istoveten z: EN 61116:1994
ICS:
27.140 Vodna energija Hydraulic energy engineering
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
...
This May Also Interest You
Describes a method of specifying requirements for low-voltage power supply devices (including switching types) providing d.c. output(s) up to 200 V d.c. at a power level up to 30 kW, operating from a.c. or d.c. source voltages of up to 600 V. The devices are for use within class I equipment or for free-standing operation when used with adequate electrical and mechanical protection, except for medical applications and toys, where special considerations apply.
- Standard33 pagesEnglish languagesale 10% offe-Library read for×1 day
- 17-Jan-1995
- 30-Nov-1995
- 29.160.40
- 2006/95/EC
- 2014/35/EU
- 2014/53/EU
- 73/23/EEC
- CLC/TC 22X
IEC 62974-1:2024 specifies product and performance requirements for devices that fall under the heading of "monitoring and measuring systems used for data collection, aggregation and analysis", for industrial, commercial, and similar use rated below or equal to 1 kV AC and 1,5 kV DC. These devices are fixed and are intended to be used indoors as panel-mounted devices, or as modular devices fixed on a DIN rail, or as housing devices fixed on a DIN rail, or as devices fixed by other means inside a cabinet. These devices are used to upload or download information (energy measured on loads, power metering and monitoring data, temperature information, etc.), mainly for energy efficiency purposes. These devices are known as energy servers (ESE), energy data loggers (EDL), data gateways (DGW) and I/O data concentrators (IODC) and are grouped together under the family name of Data Management Devices (DMD). This document does not cover: • devices used only in the consumer market (living quarters) or household; • devices used in the smart metering infrastructure (e.g. smart meters); • devices used in the smart grid infrastructure; • devices used as IT servers in the information technology business; • power metering and monitoring devices (PMD); • I/O data concentrators already covered by a specific product standard; • communication protocols and interoperability; • power quality instruments (PQI); • software used for the data collection and analysis of the power quality for the supply side. IEC 62974-1:2024 cancels and replaces the first edition published in 2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) the performance criteria have been reviewed; b) EMC and safety requirements have been improved; c) mechanical requirements have been clarified and amended.
- Draft30 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 60688:2024 applies to transducers (TRD) with electrical inputs and outputs for making measurements of AC or DC electrical quantities. The output signal can be in the form of an analogue or digital signal. This document applies to measuring transducers used for converting electrical quantities such as: – current, – voltage, – active power, – reactive power, – power factor, – phase angle, – frequency, – harmonics or total harmonic distortion, – apparent power, and – DC power to an output signal. This document applies a) if the fundamental frequency of the input(s) lies between 0 Hz and 1 500 Hz, b) to the electrical measuring transducer if it is part of a system for the measurement of an electrical or non-electrical quantity, c) to transducers for use in a variety of applications such as telemetry and process control and in one of a number of defined environments. This document is not applicable for: – instrument transformers that comply with IEC 61869 (all parts), – transmitters for use in an industrial process application that comply with IEC 60770 (all parts), – power metering and monitoring devices (PMD) that comply with IEC 61557-12, – meters that comply with the IEC 62053 series, – handheld sensors, – residual current monitoring devices (RCMs) that comply with IEC 62020-1, – residual current detecting devices (RDC-DD) that comply with IEC 62955, – in-cable control and protection devices (IC-CPDs) that comply with IEC 62752, – modular residual current devices (MRCDs) that comply with IEC 60947 2:2016/AMD1:2019, Annex M. Within the measuring range, the output signal is a function of the measurand. An auxiliary supply can be required. This document is intended: – to specify the terminology and definitions relating to transducers whose main application is in industry, – to unify the test methods used in evaluating transducer performance, – to specify accuracy limits and output values for transducers. IEC 60688:2024 cancels and replaces the fourth edition published in 2021. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) updating normative references; b) updating definitions; c) updating structure; d) adding DC power measurement.
- Draft124 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 60601-2-34:2024 applies to BASIC SAFETY and ESSENTIAL PERFORMANCE of INVASIVE BLOOD PRESSURE MONITORING EQUIPMENT as defined in 201.3.63, hereinafter also referred to as ME EQUIPMENT. This document applies to INVASIVE BLOOD PRESSURE MONITORING EQUIPMENT intended for use in professional healthcare facilities and in the EMERGENCY MEDICAL SERVICE ENVIRONMENT. This document does not apply to catheter tubing, catheter needles, Luer locks, taps and tap tables that connect to the DOME. This document does not apply to non-invasive blood pressure monitoring equipment. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as follows: The clause or subclause applies to ME EQUIPMENT, as default and, only if the corresponding safety measure or function is not completely integrated into the ME EQUIPMENT but implemented as part of an ME SYSTEM, the clause or subclause applies to the ME SYSTEM. IEC 60601-2-34:2024 cancels and replaces the third edition of IEC 60601-2-34 published in 2011 and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) revision to align with IEC 60601-1:2005, IEC 60601-1:2005/AMD1:2012 and IEC 60601-1:2005/AMD2:2020, as well as new versions of collateral standards and amendments thereto; b) expansion of the scope to the emergency medical service environment; c) changed essential performance in Table 201.101; d) changed requirement for ingress protection; e) added primary operating functions; f) deleted Annex BB Alarm diagrams.
- Draft59 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 62683-2:2024 specifies the functional safety and reliability data model descriptions for low‑voltage switchgear and controlgear to be used by engineering tools for the design of safety related control systems according to IEC 62061, IEC 61508-2 and ISO 13849-1, and for dependability analysis of electrotechnical systems. This dictionary is used to facilitate the exchange between computers of data characterizing low-voltage switchgear and controlgear. Each property has an unambiguously defined meaning and naming, and where relevant, a defined value list, a defined format and a defined unit. The data models described in this document are intended to complement the product catalogue data defined by IEC 62683-1. This document does not cover: - exchange format such as defined in VDMA 66413, - explosive atmosphere applications, - manufacturer specific features.
- Draft15 pagesEnglish languagesale 10% offe-Library read for×1 day
- 19-Dec-2024
- 29.130.20
- CLC/SR 121
This part of IEC 61557 specifies the requirements for measuring equipment that combines several measuring functions or methods of testing, measuring or monitoring, that are in accordance with the respective parts of IEC 61557, into one piece of apparatus. Measuring equipment which combines measuring functions or methods of testing, measuring or monitoring covered by the respective parts of IEC 61557 with those not covered by the respective parts of IEC 61557 is also within the scope of this document.
- Draft9 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft3 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 60705:2024 applies to microwave ovens for household and similar use, it also applies to microwave ovens with grills and combination microwave ovens. This document defines the main performance characteristics of these appliances, which are of interest to the user, and it specifies methods for measuring these characteristics. The manufacturer defines the primary cooking function of the appliance, microwave function or thermal heat. The primary cooking function will be measured with an existing method according to energy consumption. If the primary cooking function is declared as a microwave function, IEC 60705 will be applied for energy consumption measurement. If the primary cooking function is declared as a thermal heat, IEC 60350-1 will be applied for energy consumption measurement. If the manufacturer does not declare the primary function, the performance of the microwave function and thermal heat is measured as far as it is possible. There is currently no measurement method for the energy consumption for grilling and steam functions. This document does not deal with safety requirements (see IEC 60335-2-25 [1] ). This document does not apply to appliances incorporating thermal heat, steam function or hot steam function only. These appliances are covered by IEC 60350-1. This fifth edition cancels and replaces the fourth edition published in 2010, Amendment 1: 2014 and Amendment 2: 2018. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) thematically ordered new sequence of the clauses; b) updated normative references; c) introduced a new definition for microwave generator to open the standard for microwave ovens with one or more magnetrons or solid-state components; d) aligned with IEC 60350-1:2023 regarding the definitions and references; e) aligned preparation of water load for Clause 8 and Clause 10; f) removed the definitions for set to off mode and set to standby mode ; g) added new definitions regarding low power modes; h) aligned the low power mode measurement, Clause 11, to IEC 60350-1:2023; i) revised square tank tests to one new 12.2; j) revised the dishes used for Clause 12, Clause 13 and Clause 14 and removal of Annex B; k) removed A.3.3; l) removed Annex F for measuring the energy consumption of the cooling down period; m) former Annex E will be substituted by a supporting document located on the IEC's website.
- Draft38 pagesEnglish languagesale 10% offe-Library read for×1 day
- 19-Dec-2024
- 97.040.20
- M/495
- CLC/TC 59X
- Draft3 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 60598-1:2024 specifies general safety requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. Requirements for semi-luminaires are included in this document. This tenth edition cancels and replaces the ninth edition published in 2020. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) new structure to comply with the ISO/IEC Directives, Part 2; b) addition of a new Annex V for comparison with the previous edition; c) revision of 7.32 for SPDs and for SPCs; d) the terms "live part" and "active part" were reviewed and aligned with the definitions of "live part" and "hazardous live part" given in IEC 60050-195; e) revision of 7.14.2 for conductor mechanical stress; f) revision of 14.5.2, Item 4 to include controlgear; g) revision of 9.2.1 (Earthing) with the deletion of the word "permanently"; h) revision of Annex N: earth continuity test time; i) revision of 7.11.4; 7.14.1; Table 22 (14.4.3): Introduction of requirements for suspension by magnets; j) addition of a new Annex W for luminaires using batteries; k) clarification of Clause 6 for marking requirements for nature of supply; l) addition of a new Subclause 7.31.5: Additional requirements for luminaires using controllable controlgear providing SELV output(s); m) revision of 6.4.16: Information to be provided for luminaire having protective earth current > 10 mA; n) revision of 6.3.23; 6.4.18; 6.4.24; 7.30 and 10.2.1 for serviceable, non-user serviceable and non-serviceable components; o) revision of Annex D: Draught-proof enclosure; p) revision of 8.2.1 and 13.2.1: Inconsistencies in the inclusion of the limits of voltage ranges; q) revision of 9.2.10 for looping-in; r) Revision of Clause 2 and 7.8: update of the reference to IEC 61058-1-1, IEC 61058-1-2 and IEC 6105821. Update of temperature limits in Table 21 (14.4.3) for luminaires incorporating switches according to IEC 60669-1 or IEC 60669-2-1; s) revision of 6.3.22 and 7.24 for photobiological safety; t) addition of a new Subclause 6.3.27 for marking of mains socket outlet moved from information requirements.
- Draft257 pagesEnglish languagesale 10% offe-Library read for×1 day
- 19-Dec-2024
- 29.140.40
- 2014/35/EU
- M/511
- CLC/TC 34
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.