SIST-TS CEN ISO/TS 23818-2:2022
(Main)Assessment of conformity of plastics piping systems for the rehabilitation of existing pipelines - Part 2: Resin-fibre composite (RFC) material (ISO/TS 23818-2:2021)
Assessment of conformity of plastics piping systems for the rehabilitation of existing pipelines - Part 2: Resin-fibre composite (RFC) material (ISO/TS 23818-2:2021)
This part of ISO/PWI TS 23818 gives the assessment of conformity of RFC products for the rehabilitation of existing pipelines, in accordance with the applicable parts of ISO 11296, ISO 11297, and ISO 11298, and intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of certification procedures. It applies to cured-in-place pipe (CIPP) products only. It applies to non-pressure pipe liners, and to independent (fully structural, class A) and interactive (semi structural, class B) pressure pipe liners, as defined in ISO 11295, which do not rely on adhesion to the existing pipeline. NOTE In order to help the reader, summary tables of overall scheme requirements are provided in Annex E.
Konformitätsbewertung von Kunststoffrohrleitungssystemen zur Sanierung von bestehenden Rohrleitungen - Teil 2: Harz-Faser Verbundwerkstoff (RCF) (ISO/TS 23818 2:2021)
Dieses Dokument enthält ein Schema der Konformitätsbewertung von RFC Produkten für die Sanierung bestehender Rohrleitungen in Übereinstimmung mit den anwendbaren Teilen von ISO 11296, ISO 11297 und ISO 11298, das zur Aufnahme in den Qualitätssicherungsplan des Herstellers als Teil des Qualitätsmanagementsystems und für die Erstellung von Zertifizierungsverfahren vorgesehen ist.
Es ist nur anwendbar für vor Ort gehärtete Schlauch-Lining-Produkte (CIPP). Es ist anwendbar für drucklose Liner und für unabhängige (vollständig statisch belastbar, Klasse A) und interaktive (semi-statisch belastbar, Klasse B) Druckleitungs-Liner nach der Definition in ISO 11295, die nicht von der Verklebung mit der vorhandenen Rohrleitung abhängen.
ANMERKUNG Zur Unterstützung der Leser sind in Anhang E zusammenfassende Tabellen der allgemeinen Anforderungen aus dem Schema enthalten.
Évaluation de la conformité des systèmes de canalisations en plastique destinés à la réhabilitation des réseaux existants - Partie 2: Matériau composite résine-fibres (RFC) (ISO/TS 23818-2:2021)
Ugotavljanje skladnosti cevnih sistemov iz polimernih materialov za obnovo obstoječih cevovodov - 2. del: Kompozitni material iz smolnih vlaken (RFC) (ISO/TS 23818-2:2021)
Ta del dokumenta ISO/PWI TS 23818 vsebuje navodila za ugotavljanje skladnosti izdelkov iz kompozitnega materiala iz smolnih vlaken (RCF) za obnovo obstoječih cevovodov z ustreznimi deli standardov ISO 11296, ISO 11297 in ISO 11298, ki naj bi se vključila v poslovnik kakovosti proizvajalca kot del sistema vodenja kakovosti, pa tudi za vzpostavitev postopka certificiranja. Uporablja se samo za cevi, utrjene na mestu vgradnje (CIPP). Uporablja se za obloge netlačnih cevi in za neodvisne (popolnoma strukturne, razred A) ter interaktivne (polstrukturne, razred B) obloge tlačnih cevi, kakor je opredeljeno v standardu ISO 11295, ki jih ni treba pritrditi na obstoječi cevovod. OPOMBA: V pomoč bralcu dodatek E vsebuje preglednice s povzetkom splošnih shematskih zahtev.
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
SIST-TS CEN ISO/TS 23818-2:2022
01-oktober-2022
Ugotavljanje skladnosti cevnih sistemov iz polimernih materialov za obnovo
obstoječih cevovodov - 2. del: Kompozitni material iz smolnih vlaken (RFC)
(ISO/TS 23818-2:2021)
Assessment of conformity of plastics piping systems for the rehabilitation of existing
pipelines - Part 2: Resin-fibre composite (RFC) material (ISO/TS 23818-2:2021)
Évaluation de la conformité des systèmes de canalisations en plastique destinés à la
réhabilitation des réseaux existants - Partie 2: Matériau composite résine-fibres (RFC)
(ISO/TS 23818-2:2021)
Ta slovenski standard je istoveten z: CEN ISO/TS 23818-2:2022
ICS:
23.040.20 Cevi iz polimernih materialov Plastics pipes
83.140.40 Gumene cevi Hoses
SIST-TS CEN ISO/TS 23818-2:2022 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST-TS CEN ISO/TS 23818-2:2022
---------------------- Page: 2 ----------------------
SIST-TS CEN ISO/TS 23818-2:2022
CEN ISO/TS 23818-2
TECHNICAL SPECIFICATION
SPÉCIFICATION TECHNIQUE
August 2022
TECHNISCHE SPEZIFIKATION
ICS 23.040.20
English Version
Assessment of conformity of plastics piping systems for
the rehabilitation of existing pipelines - Part 2: Resin-fibre
composite (RFC) material (ISO/TS 23818-2:2021)
Évaluation de la conformité des systèmes de
canalisations en plastique destinés à la réhabilitation
des réseaux existants - Partie 2: Matériau composite
résine-fibres (RFC) (ISO/TS 23818-2:2021)
This Technical Specification (CEN/TS) was approved by CEN on 24 July 2022 for provisional application.
The period of validity of this CEN/TS is limited initially to three years. After two years the members of CEN will be requested to
submit their comments, particularly on the question whether the CEN/TS can be converted into a European Standard.
CEN members are required to announce the existence of this CEN/TS in the same way as for an EN and to make the CEN/TS
available promptly at national level in an appropriate form. It is permissible to keep conflicting national standards in force (in
parallel to the CEN/TS) until the final decision about the possible conversion of the CEN/TS into an EN is reached.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2022 CEN All rights of exploitation in any form and by any means reserved Ref. No. CEN ISO/TS 23818-2:2022 E
worldwide for CEN national Members.
---------------------- Page: 3 ----------------------
SIST-TS CEN ISO/TS 23818-2:2022
CEN ISO/TS 23818-2:2022 (E)
Contents Page
European foreword . 3
2
---------------------- Page: 4 ----------------------
SIST-TS CEN ISO/TS 23818-2:2022
CEN ISO/TS 23818-2:2022 (E)
European foreword
The text of ISO/TS 23818-2:2021 has been prepared by Technical Committee ISO/TC 138 "Plastics
pipes, fittings and valves for the transport of fluids” of the International Organization for
Standardization (ISO) and has been taken over as CEN ISO/TS 23818-2:2022 by Technical Committee
CEN/TC 155 “Plastics piping systems and ducting systems” the secretariat of which is held by NEN.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
Any feedback and questions on this document should be directed to the users’ national standards body.
A complete listing of these bodies can be found on the CEN website.
According to the CEN-CENELEC Internal Regulations, the national standards organizations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria,
Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland,
Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of
North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and the
United Kingdom.
Endorsement notice
The text of ISO/TS 23818-2:2021 has been approved by CEN as CEN ISO/TS 23818-2:2022 without any
modification.
3
---------------------- Page: 5 ----------------------
SIST-TS CEN ISO/TS 23818-2:2022
---------------------- Page: 6 ----------------------
SIST-TS CEN ISO/TS 23818-2:2022
TECHNICAL ISO/TS
SPECIFICATION 23818-2
First edition
2021-08
Assessment of conformity of plastics
piping systems for the rehabilitation
of existing pipelines —
Part 2:
Resin-fibre composite (RFC) material
Évaluation de la conformité des systèmes de canalisations en
plastique destinés à la réhabilitation des réseaux existants —
Partie 2: Matériau composite résine-fibres (RFC)
Reference number
ISO/TS 23818-2:2021(E)
©
ISO 2021
---------------------- Page: 7 ----------------------
SIST-TS CEN ISO/TS 23818-2:2022
ISO/TS 23818-2:2021(E)
COPYRIGHT PROTECTED DOCUMENT
© ISO 2021
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting
on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address
below or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii © ISO 2021 – All rights reserved
---------------------- Page: 8 ----------------------
SIST-TS CEN ISO/TS 23818-2:2022
ISO/TS 23818-2:2021(E)
Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
3.1 Assessment of conformity . 2
3.2 Rehabilitation general . 4
4 Abbreviated terms . 6
5 General . 6
6 Testing and inspection . 7
6.1 Grouping . 7
6.1.1 General. 7
6.1.2 Size and wall strength groups . 7
6.1.3 Fitting groups . 7
6.2 Type testing . 8
6.3 Batch release tests . 8
6.4 Process verification tests during installation . 8
6.5 CIPP product verification tests. 9
6.6 Audit tests . 9
6.7 Indirect tests . 9
6.8 Test records. 9
Annex A (normative) Test procedures for plastics piping systems for the rehabilitation of
networks for underground non-pressure drainage and sewerage .10
Annex B (normative) Test procedures for plastics piping systems for the rehabilitation of
networks for water supply and for drainage and sewerage under pressure .18
Annex C (normative) Specification of new system (N), change in design (D), change in
material (M) and extension of the product range (E) .21
Annex D (normative) Parameters and criteria for reduced long-term tests (RLTT) .23
Annex E (informative) Summary tables of scheme requirements .25
Bibliography .27
© ISO 2021 – All rights reserved iii
---------------------- Page: 9 ----------------------
SIST-TS CEN ISO/TS 23818-2:2022
ISO/TS 23818-2:2021(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www .iso .org/ directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www .iso .org/ patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and
expressions related to conformity assessment, as well as information about ISO's adherence to the
World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT), see www .iso .org/
iso/ foreword .html.
This document was prepared by Technical Committee ISO/TC 138, Plastics pipes, fittings and valves for
the transport of fluids, Subcommittee SC 8, Rehabilitation of pipeline systems.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www .iso .org/ members .html.
A list of all parts in the ISO 23818 series can be found on the ISO website.
iv © ISO 2021 – All rights reserved
---------------------- Page: 10 ----------------------
SIST-TS CEN ISO/TS 23818-2:2022
ISO/TS 23818-2:2021(E)
Introduction
System standards dealing with the following applications are either available or in preparation for
pipeline rehabilitation:
— ISO 11296, Plastics piping systems for renovation of underground non-pressure drainage and sewerage
networks;
— ISO 11297, Plastics piping systems for renovation of underground drainage and sewerage networks
under pressure;
— ISO 11298, Plastics piping systems for renovation of underground water supply networks;
— ISO 11299, Plastics piping systems for renovation of underground gas supply networks;
— ISO 21225, Plastics piping systems for the trenchless replacement of underground pipeline networks.
These system standards are distinguished from those for conventionally installed plastics piping
systems by the requirement to verify certain characteristics in the as-installed condition, after site
processing. This is in addition to specifying requirements for plastics piping system components as
manufactured.
For the assessment of conformity, three Technical Specifications for pipe lining systems of distinct
materials are applicable:
— ISO/TS 23818-1, Assessment of conformity of plastics piping systems for the rehabilitation of existing
pipelines — Part 1: Polyethylene (PE) material;
— ISO/TS 23818-2 (this document), Assessment of conformity of plastics piping systems for the
rehabilitation of existing pipelines — Part 2: Resin-fibre composite (RFC) material;
— ISO/TS 23818-3, Assessment of conformity of plastics piping systems for the rehabilitation of existing
pipelines — Part 3: Unplasticized poly(vinyl chloride) (PVC-U) material.
These three Technical Specifications cover the system standards, as presented in Table 1.
© ISO 2021 – All rights reserved v
---------------------- Page: 11 ----------------------
SIST-TS CEN ISO/TS 23818-2:2022
ISO/TS 23818-2:2021(E)
Table 1 — Structure of Technical Specifications for assessment of conformity
Application
Drainage
Non-pressure
and
Technical Mate-
drainage Water
Technique
sewerage Gas supply
Specification rial
and supply
networks networks
sewerage networks
under
networks
pressure
LINING WITH CON- ISO 11296-2 ISO 11297-2 ISO 11298-2 ISO 11299-2
TINUOUS PIPES,
ISO 11296-3 ISO 11297-3 ISO 11298-3 ISO 11299-3
CLOSE-FIT PIPES
AND SPIRALLY ISO 11296-7
WOUND PIPES
TRENCHLESS RE-
ISO/TS 23818-1 PE
PLACEMENT USING
ISO 21225-1 ISO 21225-1 ISO 21225-1 ISO 21225-1
PIPE BURSTING,
PIPE EXTRACTION,
HORIZONTAL
ISO 21225-2 ISO 21225-2 ISO 21225-2 ISO 21225-2
DRILLING AND
IMPACT MOLING
LINING WITH ISO 11296-4 ISO 11297-4 ISO 11298-4
ISO/TS 23818-2 RFC CURED-IN-PLACE
PIPES (CIPP)
LINING WITH ISO 11296-3
CLOSE-FIT PIPES
AND
ISO/TS 23818-3 PVC-U
SPIRALLY WOUND ISO 11296-7
PIPES
The format of the three Technical Specifications is in line with Technical Specifications for assessment
of conformity to other system standards, apart from presenting the detailed requirement for Inspection
and Testing in two annexes, for non-pressure applications and pressure applications (where applicable)
respectively.
The format is schematically represented in Figure 1.
vi © ISO 2021 – All rights reserved
---------------------- Page: 12 ----------------------
SIST-TS CEN ISO/TS 23818-2:2022
ISO/TS 23818-2:2021(E)
Figure 1 — Format of the Technical Specifications for the assessment of conformity
Figure 2 is intended to provide general information on the concept of testing and organization of
those tests used for the purpose of the assessment of conformity. For each type of test, i.e. type testing
(TT), batch release test (BRT), process verification test (PVT-I), CIPP product verification test (CPVT)
and audit test (AT), this document details the applicable characteristics to be assessed as well as the
frequency and sampling of testing.
Figure 2 also provides a typical scheme for the assessment of conformity of RFC pipes, fittings, joints or
assemblies by manufacturers and/or installers, including certification.
© ISO 2021 – All rights reserved vii
---------------------- Page: 13 ----------------------
SIST-TS CEN ISO/TS 23818-2:2022
ISO/TS 23818-2:2021(E)
Figure 2 — Typical scheme for the assessment of conformity by a manufacturer, including
certification
viii © ISO 2021 – All rights reserved
---------------------- Page: 14 ----------------------
SIST-TS CEN ISO/TS 23818-2:2022
TECHNICAL SPECIFICATION ISO/TS 23818-2:2021(E)
Assessment of conformity of plastics piping systems for the
rehabilitation of existing pipelines —
Part 2:
Resin-fibre composite (RFC) material
1 Scope
This document provides a scheme for the assessment of conformity of RFC products for the rehabilitation
of existing pipelines, in accordance with the applicable parts of ISO 11296, ISO 11297 and ISO 11298,
and intended to be included in the manufacturer’s quality plan as part of the quality management
system and for the establishment of certification procedures.
It applies to cured-in-place pipe (CIPP) products only. It applies to non-pressure pipe liners, and to
independent (fully structural, class A) and interactive (semi-structural, class B) pressure pipe liners, as
defined in ISO 11295, which do not rely on adhesion to the existing pipeline.
NOTE In order to help the reader, summary tables of overall scheme requirements are provided in Annex E.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
ISO 1043-1, Plastics — Symbols and abbreviated terms — Part 1: Basic polymers and their special
characteristics
ISO 10928, Plastics piping systems — Glass-reinforced thermosetting plastics (GRP) pipes and fittings —
Methods for regression analysis and their use
ISO 11296-1:2018, Plastics piping systems for renovation of underground non-pressure drainage and
sewerage networks — Part 1: General
ISO 11296-4:2018, Plastics piping systems for renovation of underground non-pressure drainage and
sewerage networks — Part 4: Lining with cured-in-place pipes
ISO 11296-4:2018/Amd 1:2021, Plastics piping systems for renovation of underground non-pressure
drainage and sewerage networks — Part 4: Lining with cured-in-place pipes — Amendment 1: Updated
definitions, marking requirements and procedure for alternative expression of flexural test results
ISO 11297-4:2018, Plastics piping systems for renovation of underground drainage and sewerage networks
under pressure — Part 4: Lining with cured-in-place pipes
ISO 11298-4:2021, Plastics piping systems for renovation of underground water supply networks — Part 4:
Lining with cured-in-place pipes
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 11296-4, ISO 11297-4,
ISO 11298-4 and the following apply.
© ISO 2021 – All rights reserved 1
---------------------- Page: 15 ----------------------
SIST-TS CEN ISO/TS 23818-2:2022
ISO/TS 23818-2:2021(E)
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https:// www .iso .org/ obp
— IEC Electropedia: available at http:// www .electropedia .org/
3.1 Assessment of conformity
3.1.1
certification body
impartial body, governmental or non-governmental, possessing the necessary competence and
responsibility to carry out certification of conformity according to given rules of procedure and
management
Note 1 to entry: A certification body should preferably operate in accordance with ISO/IEC 17021-1 or
ISO/IEC 17065.
3.1.2
inspection body
body that performs inspection
Note 1 to entry: An inspection body can be an organization, or part of an organization.
Note 2 to entry: An inspection body should preferably operate in accordance with ISO/IEC 17020 or
ISO/IEC 17021-1.
[SOURCE: ISO/IEC 17020:2012, 3.5, modified — Note 2 to entry added.]
3.1.3
testing laboratory
laboratory which measures, tests, calibrates or otherwise determines the characteristics (3.2.6) of the
performance of materials (3.1.13) and products
Note 1 to entry: In the context of this document, the materials (3.1.13) and products can be subjected to type
testing (3.1.6), batch release test (3.1.7), process verification test at the “I” stage (3.1.8), CIPP product verification
test (3.1.20), audit test (3.1.9), and witness test (3.1.11), as applicable.
Note 2 to entry: A testing laboratory should preferably operate in accordance with ISO/IEC 17025.
3.1.4
quality management system
part of a management system with regard to quality
Note 1 to entry: Requirements for quality management systems are given in ISO 9001.
[SOURCE: ISO 9000:2015, 3.5.4, modified — Note 1 to entry added.]
3.1.5
quality plan
document setting out the specific quality practices, resources and sequence of activities relevant to a
particular product or range of products
3.1.6
type testing
TT
testing performed to prove that the material (3.1.13), pipe, joint (3.1.17) or assembly is capable of
conforming to the requirements given in the relevant standard
Note 1 to entry: The type test results remain valid until there is a change in the material (3.1.13) or product or
assembly provided that the process verification tests are done regularly.
2 © ISO 2021 – All rights reserved
---------------------- Page: 16 ----------------------
SIST-TS CEN ISO/TS 23818-2:2022
ISO/TS 23818-2:2021(E)
3.1.7
batch release test
BRT
test performed by or on behalf of the manufacturer on a batch of RFC products, which has to be
satisfactorily completed before the batch can be released
Note 1 to entry: For CIPP, BRT is applicable to a lining tube batch (3.1.19) only.
[SOURCE: ISO/TS 23818-1:2020, 3.1.7, modified — "PE" changed to "RFC" and Note 1 to entry added.]
3.1.8
process verification test at the “I” stage
PVT-I
test performed by or on behalf of the manufacturer or installer at specific intervals during the
installation process to confirm that the process as specified in the installation manual continues to
be capable of producing installed products which conform to the requirements given in the relevant
standard
Note 1 to entry: Such tests are not required to release batches of products and are carried out as a measure of
process control.
3.1.9
audit test
AT
test performed by a test laboratory on behalf of an inspection body (3.1.2) or certification body (3.1.1) to
confirm that the product continues to conform to the requirements given in the relevant standard and
to provide information to assess the effectiveness of the quality management system (3.1.4)
3.1.10
indirect test
IT
test performed by or on behalf of the manufacturer, different from that specified test for that particular
characteristic (3.2.6), having previously verified its correlation with the specified test
3.1.11
witness test
WT
test accepted by an inspection or a certification body (3.1.1) for type testing (3.1.6) and/or audit test
(3.1.9), which is carried out by or on behalf of the manufacturer and supervised by a representative of
the inspection or certification body (3.1.1), competent in testing
3.1.12
reduced long-term test
RLTT
test using shorter time periods or fewer test pieces than those specified for a full long-term test
[SOURCE: CEN/TS 14632:2012, 3.17, modified]
3.1.13
material
generic term for compositions grouped by families, expressed by generic names, e.g. polypropylene,
stainless steel, brass or EPDM
Note 1 to entry: Definition from European Commission, Directorate-General for Enterprise and Industry, Sub-
group on Product Testing Procedures (EC, DG ENT and IND, SG PTP).
© ISO 2021 – All rights reserved 3
---------------------- Page: 17 ----------------------
SIST-TS CEN ISO/TS 23818-2:2022
ISO/TS 23818-2:2021(E)
3.1.14
sample
one or more products drawn from the same production batch or lot, selected at random without regard
to their quality
Note 1 to entry: The number of products in the sample is the sample size.
3.1.15
group
collection of similar products from which samples (3.1.14) are selected for testing purposes
3.1.16
component
product manufactured out of a specific composition compound brought to the market as part of another
product or as a spare part.
Note 1 to entry: For drinking water application, components may be considered as products and be individually
approved (e.g. O-ring, gasket) or they are tested as an integral part of a finished product (e.g. in a valve).
3.1.17
joint
connection between two products
3.1.18
product type
generic description of a product
EXAMPLE A pipe or fitting or valve or their main parts, of the same design, from a particular compound.
3.1.19
lining tube batch
clearly identified collection of lining tubes, manufactured consecutively or continuously under the same
conditions, using the same material (3.1.13) conforming to the same specification
Note 1 to entry: The batch is defined and identified by the lining tube manufacturer.
3.1.20
CIPP product verification test
CPVT
test performed by or on behalf of the manufacturer or installer at the “I” stage (3.2.11) to verify that the
“I” stage characteristics (3.2.6) of the CIPP product conform with the respective declared values (3.2.7)
3.2 Rehabilitation general
3.2.1
rehabilitation
measures for restoring or upgrading the performance of existing systems, including renovation (3.2.2),
repair and replacement
3.2.2
renovation
work incorporating all or part of the original fabric of the pipeline, by means of which its current
performance is improved
3.2.3
lining pipe
pipe inserted for renovation (3.2.2) purposes
Note 1 to entry: For CIPP, the lining tube fulfils the function of lining pipe
4 © ISO 2021 – All rights reserved
---------------------- Page: 18 ----------------------
SIST-TS CEN ISO/TS 23818-2:2022
ISO/TS 23818-2:2021(E)
3.2.4
liner
lining pipe (3.2.3) after installation
3.2.5
lining system
lining pipe (3.2.3) and all relevant fittings for insertion into an existing pipeline for the purposes of
renovation (3.2.2)
3.2.6
characteristic
property, dimension or other feature of a material (3.1.13) or component (3.1.16)
3.2.7
declared value
limiting value of a characteristic (3.2.6) declared in advance by the lining system (3.2.5) supplier, which
becomes the requirement for the purposes of assessment of conformity
3.2.8
simulated installation
installation of a lining system (3.2.5) into a simulated host pipeline (3.2.9), using representative
equipment and processes, to provide samples (3.1.14) for testing which are representative of an actual
installation
3.2.9
simulated host pipeline
section of pipeline, which is not part of an operational network, but which replicates the environment of
an operational network
3.2.10
"M" stage
stage as manufactured, before any subsequent site processing of components (3.1.16) associated with
the particular renovation (3.2.2) technique
3.2.11
"I" stage
stage as installed, i.e. in final configuration after any site processing of components (3.1.16) associated
with the particular renovation (3.2.2) technique
3.2.12
nominal size
DN
numerical designation of the size of a component (3.1.16), which is a convenient round number
approximately equal to the inside or
...
SLOVENSKI STANDARD
kSIST-TS FprCEN ISO/TS 23818-2:2022
01-junij-2022
Ugotavljanje skladnosti cevnih sistemov iz polimernih materialov za obnovo
obstoječih cevovodov - 2. del: Kompozitni material iz smolnih vlaken (RFC)
(ISO/TS 23818-2:2021)
Assessment of conformity of plastics piping systems for the rehabilitation of existing
pipelines - Part 2: Resin-fibre composite (RFC) material (ISO/TS 23818-2:2021)
Évaluation de la conformité des systèmes de canalisations en plastique destinés à la
réhabilitation des réseaux existants - Partie 2: Matériau composite résine-fibres (RFC)
(ISO/TS 23818-2:2021)
Ta slovenski standard je istoveten z: FprCEN ISO/TS 23818-2
ICS:
23.040.20 Cevi iz polimernih materialov Plastics pipes
83.140.40 Gumene cevi Hoses
kSIST-TS FprCEN ISO/TS 23818-2:2022 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
kSIST-TS FprCEN ISO/TS 23818-2:2022
---------------------- Page: 2 ----------------------
kSIST-TS FprCEN ISO/TS 23818-2:2022
TECHNICAL ISO/TS
SPECIFICATION 23818-2
First edition
2021-08
Assessment of conformity of plastics
piping systems for the rehabilitation
of existing pipelines —
Part 2:
Resin-fibre composite (RFC) material
Évaluation de la conformité des systèmes de canalisations en
plastique destinés à la réhabilitation des réseaux existants —
Partie 2: Matériau composite résine-fibres (RFC)
Reference number
ISO/TS 23818-2:2021(E)
©
ISO 2021
---------------------- Page: 3 ----------------------
kSIST-TS FprCEN ISO/TS 23818-2:2022
ISO/TS 23818-2:2021(E)
COPYRIGHT PROTECTED DOCUMENT
© ISO 2021
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting
on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address
below or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii © ISO 2021 – All rights reserved
---------------------- Page: 4 ----------------------
kSIST-TS FprCEN ISO/TS 23818-2:2022
ISO/TS 23818-2:2021(E)
Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
3.1 Assessment of conformity . 2
3.2 Rehabilitation general . 4
4 Abbreviated terms . 6
5 General . 6
6 Testing and inspection . 7
6.1 Grouping . 7
6.1.1 General. 7
6.1.2 Size and wall strength groups . 7
6.1.3 Fitting groups . 7
6.2 Type testing . 8
6.3 Batch release tests . 8
6.4 Process verification tests during installation . 8
6.5 CIPP product verification tests. 9
6.6 Audit tests . 9
6.7 Indirect tests . 9
6.8 Test records. 9
Annex A (normative) Test procedures for plastics piping systems for the rehabilitation of
networks for underground non-pressure drainage and sewerage .10
Annex B (normative) Test procedures for plastics piping systems for the rehabilitation of
networks for water supply and for drainage and sewerage under pressure .18
Annex C (normative) Specification of new system (N), change in design (D), change in
material (M) and extension of the product range (E) .21
Annex D (normative) Parameters and criteria for reduced long-term tests (RLTT) .23
Annex E (informative) Summary tables of scheme requirements .25
Bibliography .27
© ISO 2021 – All rights reserved iii
---------------------- Page: 5 ----------------------
kSIST-TS FprCEN ISO/TS 23818-2:2022
ISO/TS 23818-2:2021(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www .iso .org/ directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www .iso .org/ patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and
expressions related to conformity assessment, as well as information about ISO's adherence to the
World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT), see www .iso .org/
iso/ foreword .html.
This document was prepared by Technical Committee ISO/TC 138, Plastics pipes, fittings and valves for
the transport of fluids, Subcommittee SC 8, Rehabilitation of pipeline systems.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www .iso .org/ members .html.
A list of all parts in the ISO 23818 series can be found on the ISO website.
iv © ISO 2021 – All rights reserved
---------------------- Page: 6 ----------------------
kSIST-TS FprCEN ISO/TS 23818-2:2022
ISO/TS 23818-2:2021(E)
Introduction
System standards dealing with the following applications are either available or in preparation for
pipeline rehabilitation:
— ISO 11296, Plastics piping systems for renovation of underground non-pressure drainage and sewerage
networks;
— ISO 11297, Plastics piping systems for renovation of underground drainage and sewerage networks
under pressure;
— ISO 11298, Plastics piping systems for renovation of underground water supply networks;
— ISO 11299, Plastics piping systems for renovation of underground gas supply networks;
— ISO 21225, Plastics piping systems for the trenchless replacement of underground pipeline networks.
These system standards are distinguished from those for conventionally installed plastics piping
systems by the requirement to verify certain characteristics in the as-installed condition, after site
processing. This is in addition to specifying requirements for plastics piping system components as
manufactured.
For the assessment of conformity, three Technical Specifications for pipe lining systems of distinct
materials are applicable:
— ISO/TS 23818-1, Assessment of conformity of plastics piping systems for the rehabilitation of existing
pipelines — Part 1: Polyethylene (PE) material;
— ISO/TS 23818-2 (this document), Assessment of conformity of plastics piping systems for the
rehabilitation of existing pipelines — Part 2: Resin-fibre composite (RFC) material;
— ISO/TS 23818-3, Assessment of conformity of plastics piping systems for the rehabilitation of existing
pipelines — Part 3: Unplasticized poly(vinyl chloride) (PVC-U) material.
These three Technical Specifications cover the system standards, as presented in Table 1.
© ISO 2021 – All rights reserved v
---------------------- Page: 7 ----------------------
kSIST-TS FprCEN ISO/TS 23818-2:2022
ISO/TS 23818-2:2021(E)
Table 1 — Structure of Technical Specifications for assessment of conformity
Application
Drainage
Non-pressure
and
Technical Mate-
drainage Water
Technique
sewerage Gas supply
Specification rial
and supply
networks networks
sewerage networks
under
networks
pressure
LINING WITH CON- ISO 11296-2 ISO 11297-2 ISO 11298-2 ISO 11299-2
TINUOUS PIPES,
ISO 11296-3 ISO 11297-3 ISO 11298-3 ISO 11299-3
CLOSE-FIT PIPES
AND SPIRALLY ISO 11296-7
WOUND PIPES
TRENCHLESS RE-
ISO/TS 23818-1 PE
PLACEMENT USING
ISO 21225-1 ISO 21225-1 ISO 21225-1 ISO 21225-1
PIPE BURSTING,
PIPE EXTRACTION,
HORIZONTAL
ISO 21225-2 ISO 21225-2 ISO 21225-2 ISO 21225-2
DRILLING AND
IMPACT MOLING
LINING WITH ISO 11296-4 ISO 11297-4 ISO 11298-4
ISO/TS 23818-2 RFC CURED-IN-PLACE
PIPES (CIPP)
LINING WITH ISO 11296-3
CLOSE-FIT PIPES
AND
ISO/TS 23818-3 PVC-U
SPIRALLY WOUND ISO 11296-7
PIPES
The format of the three Technical Specifications is in line with Technical Specifications for assessment
of conformity to other system standards, apart from presenting the detailed requirement for Inspection
and Testing in two annexes, for non-pressure applications and pressure applications (where applicable)
respectively.
The format is schematically represented in Figure 1.
vi © ISO 2021 – All rights reserved
---------------------- Page: 8 ----------------------
kSIST-TS FprCEN ISO/TS 23818-2:2022
ISO/TS 23818-2:2021(E)
Figure 1 — Format of the Technical Specifications for the assessment of conformity
Figure 2 is intended to provide general information on the concept of testing and organization of
those tests used for the purpose of the assessment of conformity. For each type of test, i.e. type testing
(TT), batch release test (BRT), process verification test (PVT-I), CIPP product verification test (CPVT)
and audit test (AT), this document details the applicable characteristics to be assessed as well as the
frequency and sampling of testing.
Figure 2 also provides a typical scheme for the assessment of conformity of RFC pipes, fittings, joints or
assemblies by manufacturers and/or installers, including certification.
© ISO 2021 – All rights reserved vii
---------------------- Page: 9 ----------------------
kSIST-TS FprCEN ISO/TS 23818-2:2022
ISO/TS 23818-2:2021(E)
Figure 2 — Typical scheme for the assessment of conformity by a manufacturer, including
certification
viii © ISO 2021 – All rights reserved
---------------------- Page: 10 ----------------------
kSIST-TS FprCEN ISO/TS 23818-2:2022
TECHNICAL SPECIFICATION ISO/TS 23818-2:2021(E)
Assessment of conformity of plastics piping systems for the
rehabilitation of existing pipelines —
Part 2:
Resin-fibre composite (RFC) material
1 Scope
This document provides a scheme for the assessment of conformity of RFC products for the rehabilitation
of existing pipelines, in accordance with the applicable parts of ISO 11296, ISO 11297 and ISO 11298,
and intended to be included in the manufacturer’s quality plan as part of the quality management
system and for the establishment of certification procedures.
It applies to cured-in-place pipe (CIPP) products only. It applies to non-pressure pipe liners, and to
independent (fully structural, class A) and interactive (semi-structural, class B) pressure pipe liners, as
defined in ISO 11295, which do not rely on adhesion to the existing pipeline.
NOTE In order to help the reader, summary tables of overall scheme requirements are provided in Annex E.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
ISO 1043-1, Plastics — Symbols and abbreviated terms — Part 1: Basic polymers and their special
characteristics
ISO 10928, Plastics piping systems — Glass-reinforced thermosetting plastics (GRP) pipes and fittings —
Methods for regression analysis and their use
ISO 11296-1:2018, Plastics piping systems for renovation of underground non-pressure drainage and
sewerage networks — Part 1: General
ISO 11296-4:2018, Plastics piping systems for renovation of underground non-pressure drainage and
sewerage networks — Part 4: Lining with cured-in-place pipes
ISO 11296-4:2018/Amd 1:2021, Plastics piping systems for renovation of underground non-pressure
drainage and sewerage networks — Part 4: Lining with cured-in-place pipes — Amendment 1: Updated
definitions, marking requirements and procedure for alternative expression of flexural test results
ISO 11297-4:2018, Plastics piping systems for renovation of underground drainage and sewerage networks
under pressure — Part 4: Lining with cured-in-place pipes
ISO 11298-4:2021, Plastics piping systems for renovation of underground water supply networks — Part 4:
Lining with cured-in-place pipes
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 11296-4, ISO 11297-4,
ISO 11298-4 and the following apply.
© ISO 2021 – All rights reserved 1
---------------------- Page: 11 ----------------------
kSIST-TS FprCEN ISO/TS 23818-2:2022
ISO/TS 23818-2:2021(E)
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https:// www .iso .org/ obp
— IEC Electropedia: available at http:// www .electropedia .org/
3.1 Assessment of conformity
3.1.1
certification body
impartial body, governmental or non-governmental, possessing the necessary competence and
responsibility to carry out certification of conformity according to given rules of procedure and
management
Note 1 to entry: A certification body should preferably operate in accordance with ISO/IEC 17021-1 or
ISO/IEC 17065.
3.1.2
inspection body
body that performs inspection
Note 1 to entry: An inspection body can be an organization, or part of an organization.
Note 2 to entry: An inspection body should preferably operate in accordance with ISO/IEC 17020 or
ISO/IEC 17021-1.
[SOURCE: ISO/IEC 17020:2012, 3.5, modified — Note 2 to entry added.]
3.1.3
testing laboratory
laboratory which measures, tests, calibrates or otherwise determines the characteristics (3.2.6) of the
performance of materials (3.1.13) and products
Note 1 to entry: In the context of this document, the materials (3.1.13) and products can be subjected to type
testing (3.1.6), batch release test (3.1.7), process verification test at the “I” stage (3.1.8), CIPP product verification
test (3.1.20), audit test (3.1.9), and witness test (3.1.11), as applicable.
Note 2 to entry: A testing laboratory should preferably operate in accordance with ISO/IEC 17025.
3.1.4
quality management system
part of a management system with regard to quality
Note 1 to entry: Requirements for quality management systems are given in ISO 9001.
[SOURCE: ISO 9000:2015, 3.5.4, modified — Note 1 to entry added.]
3.1.5
quality plan
document setting out the specific quality practices, resources and sequence of activities relevant to a
particular product or range of products
3.1.6
type testing
TT
testing performed to prove that the material (3.1.13), pipe, joint (3.1.17) or assembly is capable of
conforming to the requirements given in the relevant standard
Note 1 to entry: The type test results remain valid until there is a change in the material (3.1.13) or product or
assembly provided that the process verification tests are done regularly.
2 © ISO 2021 – All rights reserved
---------------------- Page: 12 ----------------------
kSIST-TS FprCEN ISO/TS 23818-2:2022
ISO/TS 23818-2:2021(E)
3.1.7
batch release test
BRT
test performed by or on behalf of the manufacturer on a batch of RFC products, which has to be
satisfactorily completed before the batch can be released
Note 1 to entry: For CIPP, BRT is applicable to a lining tube batch (3.1.19) only.
[SOURCE: ISO/TS 23818-1:2020, 3.1.7, modified — "PE" changed to "RFC" and Note 1 to entry added.]
3.1.8
process verification test at the “I” stage
PVT-I
test performed by or on behalf of the manufacturer or installer at specific intervals during the
installation process to confirm that the process as specified in the installation manual continues to
be capable of producing installed products which conform to the requirements given in the relevant
standard
Note 1 to entry: Such tests are not required to release batches of products and are carried out as a measure of
process control.
3.1.9
audit test
AT
test performed by a test laboratory on behalf of an inspection body (3.1.2) or certification body (3.1.1) to
confirm that the product continues to conform to the requirements given in the relevant standard and
to provide information to assess the effectiveness of the quality management system (3.1.4)
3.1.10
indirect test
IT
test performed by or on behalf of the manufacturer, different from that specified test for that particular
characteristic (3.2.6), having previously verified its correlation with the specified test
3.1.11
witness test
WT
test accepted by an inspection or a certification body (3.1.1) for type testing (3.1.6) and/or audit test
(3.1.9), which is carried out by or on behalf of the manufacturer and supervised by a representative of
the inspection or certification body (3.1.1), competent in testing
3.1.12
reduced long-term test
RLTT
test using shorter time periods or fewer test pieces than those specified for a full long-term test
[SOURCE: CEN/TS 14632:2012, 3.17, modified]
3.1.13
material
generic term for compositions grouped by families, expressed by generic names, e.g. polypropylene,
stainless steel, brass or EPDM
Note 1 to entry: Definition from European Commission, Directorate-General for Enterprise and Industry, Sub-
group on Product Testing Procedures (EC, DG ENT and IND, SG PTP).
© ISO 2021 – All rights reserved 3
---------------------- Page: 13 ----------------------
kSIST-TS FprCEN ISO/TS 23818-2:2022
ISO/TS 23818-2:2021(E)
3.1.14
sample
one or more products drawn from the same production batch or lot, selected at random without regard
to their quality
Note 1 to entry: The number of products in the sample is the sample size.
3.1.15
group
collection of similar products from which samples (3.1.14) are selected for testing purposes
3.1.16
component
product manufactured out of a specific composition compound brought to the market as part of another
product or as a spare part.
Note 1 to entry: For drinking water application, components may be considered as products and be individually
approved (e.g. O-ring, gasket) or they are tested as an integral part of a finished product (e.g. in a valve).
3.1.17
joint
connection between two products
3.1.18
product type
generic description of a product
EXAMPLE A pipe or fitting or valve or their main parts, of the same design, from a particular compound.
3.1.19
lining tube batch
clearly identified collection of lining tubes, manufactured consecutively or continuously under the same
conditions, using the same material (3.1.13) conforming to the same specification
Note 1 to entry: The batch is defined and identified by the lining tube manufacturer.
3.1.20
CIPP product verification test
CPVT
test performed by or on behalf of the manufacturer or installer at the “I” stage (3.2.11) to verify that the
“I” stage characteristics (3.2.6) of the CIPP product conform with the respective declared values (3.2.7)
3.2 Rehabilitation general
3.2.1
rehabilitation
measures for restoring or upgrading the performance of existing systems, including renovation (3.2.2),
repair and replacement
3.2.2
renovation
work incorporating all or part of the original fabric of the pipeline, by means of which its current
performance is improved
3.2.3
lining pipe
pipe inserted for renovation (3.2.2) purposes
Note 1 to entry: For CIPP, the lining tube fulfils the function of lining pipe
4 © ISO 2021 – All rights reserved
---------------------- Page: 14 ----------------------
kSIST-TS FprCEN ISO/TS 23818-2:2022
ISO/TS 23818-2:2021(E)
3.2.4
liner
lining pipe (3.2.3) after installation
3.2.5
lining system
lining pipe (3.2.3) and all relevant fittings for insertion into an existing pipeline for the purposes of
renovation (3.2.2)
3.2.6
characteristic
property, dimension or other feature of a material (3.1.13) or component (3.1.16)
3.2.7
declared value
limiting value of a characteristic (3.2.6) declared in advance by the lining system (3.2.5) supplier, which
becomes the requirement for the purposes of assessment of conformity
3.2.8
simulated installation
installation of a lining system (3.2.5) into a simulated host pipeline (3.2.9), using representative
equipment and processes, to provide samples (3.1.14) for testing which are representative of an actual
installation
3.2.9
simulated host pipeline
section of pipeline, which is not part of an operational network, but which replicates the environment of
an operational network
3.2.10
"M" stage
stage as manufactured, before any subsequent site processing of components (3.1.16) associated with
the particular renovation (3.2.2) technique
3.2.11
"I" stage
stage as installed, i.e. in final configuration after any site processing of components (3.1.16) associated
with the particular renovation (3.2.2) technique
3.2.12
nominal size
DN
numerical designation of the size of a component (3.1.16), which is a convenient round number
approximately equal to the inside or outside diameter in millimetres
3.2.13
nominal outside diameter
d
n
specified outside diameter, in millimetres, assigned to a nominal size (3.2.12) DN/OD
© ISO 2021 – All rights reserved 5
---------------------- Page: 15 ----------------------
kSIST-TS FprCEN ISO/TS 23818-2:2022
ISO/TS 23818-2:2021(E)
4 Abbreviated terms
To prevent misunderstanding, the abbreviated terms relating to assessment of conformity in this
clause are defined as being the same in each language. For the same reason, the terms are given in three
languages, English, French and German.
English French German
AT audit test essai d’audit Überwachungsprüfung
BRT batch release test essai de libération de campagne de Freigabeprüfung einer Charge
fabrication
CPVT CIPP product verification test essai de vérification du produit CIPP CIPP-Produktprüfung
IT indirect test essai indirect indirekte Prüfung
PVT-I process verification test dur- essai de vérification du procédé Einbauprozessprüfung
ing installation d’installation
RLTT reduced long-term test essai à long-terme écourté verkürzte Langzeitprüfung
TT type testing essai de type Typprüfung
WT witness test essai témoin Prüfung unter Aufsicht
Furthermore, the abbreviated terms given in ISO 1043-1 and the following apply:
CIPP cured-in-place pipe
PE polyethylene
RFC resin fibre composite
PVC-U unplasticized poly(vinyl chloride)
5 General
Materials, products, joints and assemblies shall conform to the requirements given in ISO 11296,
ISO 11297 or ISO 11298, as applicable.
Where these product standards include clauses entitled ‘Regional requirements’, in countries of the
single European market, conformity shall be assessed against certain different normative references
(EN equivalents of ISO standards where not yet merged as EN ISO standards), as specified in the
product standards.
Products and assemblies shall be produced by the manufacturer under a quality management system
which includes a quality plan.
It is recommended that the quality management system conforms to ISO 9001 or similar management
system.
The production of representative “I” stage samples for type testing shall conform to ISO 11296-1:2018
8.8 and 9.4.
For the effect on water quality, attention is drawn to the requirements of National regulations.
6 © ISO 2021 – All rights reserved
---------------------- Page: 16 ----------------------
kSIST-TS FprCEN ISO/TS 23818-2:2022
ISO/TS 23818-2:2021(E)
6 Testing and inspection
6.1 Grouping
6.1.1 General
For the purposes of this document, the groups specified in 6.1.2 and 6.1.3 apply.
6.1.2 Size and wall strength groups
6.1.2.1 Non-pressure applications
Three size groups are defined for pipes and fittings, as given in Table 2.
For testing purposes, one individual nominal outside diameter, d , shall be selected from each group.
n
Within each size group a single ring stiffness shall be selected for testing, as a representative median
ring stiffness from the range offered within that size group.
NOTE In the case of structured-wall composites which can exhibit a strong variation of apparent flexural
modulus with wall thickness, additional short-term type testing on samples of the same nominal diameter, but
with ring stiffness at both extremes of the range offered within the size group, can help to define the extent of
such variation.
Table 2 — Size groups for non-pressure applications
Size group Nominal outside diameter
mm
1 d ≤ 300
n
2 300 < d ≤ 1 200
n
3 d > 1 200
n
6.1.2.2 Pressure applications
Size groups are substituted by the wall strength groups given in Table 3.
Table 3 — Wall strength groups
Initial circumferential tensile wall strength group Wall strength
1 ≤ 500 N/mm
> 500 N/mm,
2
≤ 1 000 N/mm
3 > 1 000 N/mm
For testing purposes, a sample with the least nominal wall thickness shall be selected from each
group defined by Table 3. The tensile wall strength, expressed in N/mm, determined in these tests is
representative for the group.
NOTE For the dete
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.