SIST EN 60216-4-3:2002
(Main)Electrical insulating materials - Thermal endurance properties -- Part 4-3: Ageing ovens - Multi-chamber ovens
Electrical insulating materials - Thermal endurance properties -- Part 4-3: Ageing ovens - Multi-chamber ovens
Covers the minimum requirements for ventilated and heated multi-chamber ovens used for thermal endurance evaluation of electrical insulation and of any other appropriate thermal conditioning application where the use of single-chamber ovens is inappropriate. Covers ovens designated to operate over all or part of the temperature range from 20 K above ambient to 500°C. Gives acceptance tests and in-service monitoring tests for both unloaded and loaded multi-chamber ovens and conditions of use.
Elektroisolierstoffe - Thermische Langzeiteigenschaften -- Teil 4-3: Alterungswärmeschränke - Mehrkammerwärmeschränke
Matériaux isolants électriques - Propriétés d'endurance thermique -- Partie 4-3: Etuves de vieillissement - Etuves à chambres multiples
Couvre les exigences minimales relatives aux étuves à chambres multiples ventilées et chauffées qui sont destinées à évaluer l'endurance thermique des isolations électriques et de toute autre application appropriée de conditionnement thermique, pour laquelle l'utilisation d'étuve à une seule chambre n'est pas adaptée. Couvre les étuves conçues pour fonctionner sur tout ou partie de la gamme de températures comprises entre une température ambiante plus 20 K et une température de 500°C. Elle donne les essais d'acceptation et les essais de contrôle en service concernant des étuves à plusieurs chambres chargées et non chargées, ainsi que les conditions d'utilisation.
Electrical insulating materials - Thermal endurance properties - Part 4-3: Ageing ovens - Multi-chamber ovens (IEC 60216-4-3:2000)
General Information
- Status
- Published
- Publication Date
- 30-Sep-2002
- Technical Committee
- IZO - Insulating materials
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-Oct-2002
- Due Date
- 01-Oct-2002
- Completion Date
- 01-Oct-2002
Overview
EN 60216-4-3:2000 (CLC) specifies minimum requirements for ventilated, heated multi-chamber ageing ovens used to determine the thermal endurance properties of electrical insulating materials. Aligned with IEC 60216-4-3:2000, the standard covers ovens intended to operate over all or part of the temperature range from 20 K above ambient to 500 °C. It defines acceptance tests and in‑service monitoring tests for both unloaded and loaded multi‑chamber ovens and sets out conditions of use for thermal endurance evaluation and other thermal conditioning applications where single‑chamber ovens are inappropriate.
Key topics and technical requirements
- Scope and purpose: Minimum performance and design expectations for multi‑chamber ageing ovens used in thermal endurance testing of insulating materials.
- Temperature range: Designated operation from 20 K above ambient up to 500 °C.
- Oven configuration: Requirements specific to ventilated and heated multi‑chamber designs (multiple test zones or chambers).
- Acceptance tests: Procedures and criteria to verify oven performance before commissioning.
- In‑service monitoring: Periodic checks and monitoring requirements for both loaded (with test specimens) and unloaded ovens to ensure continued compliance.
- Conditions of use: Guidance on loading, thermal conditioning regimes and environmental considerations relevant to accurate thermal ageing results.
- Instrumentation and control: Expectations for temperature control, monitoring, and uniformity (general requirements without prescribing proprietary equipment).
Practical applications
- Thermal ageing of electrical insulating materials - accelerated life testing to determine thermal endurance characteristics and serviceability.
- Material qualification and R&D - comparing insulation formulations, varnishes, tapes and composite materials under controlled thermal conditions.
- Quality assurance and product development - conditioning of components prior to electrical testing or long‑term performance evaluation.
- Specialized thermal conditioning - when single‑chamber ovens are unsuitable due to differing temperature zones, throughput, or simultaneous testing needs.
Who should use this standard
- Test laboratories and certification bodies performing thermal endurance testing.
- Manufacturers of electrical insulating materials and polymer composites.
- Oven manufacturers and test-equipment suppliers designing multi‑chamber ageing ovens.
- Quality managers, compliance officers, and R&D teams responsible for material lifetime and thermal conditioning procedures.
Related standards
- Part of the EN/IEC 60216 series on thermal endurance properties of insulating materials. EN 60216-4-3:2000 is harmonized with IEC 60216-4-3:2000 and referenced in standards for material testing and thermal conditioning.
Keywords: EN 60216-4-3, thermal endurance, electrical insulating materials, multi‑chamber ovens, ageing ovens, acceptance tests, in‑service monitoring, ventilated heated ovens.
Frequently Asked Questions
SIST EN 60216-4-3:2002 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Electrical insulating materials - Thermal endurance properties -- Part 4-3: Ageing ovens - Multi-chamber ovens". This standard covers: Covers the minimum requirements for ventilated and heated multi-chamber ovens used for thermal endurance evaluation of electrical insulation and of any other appropriate thermal conditioning application where the use of single-chamber ovens is inappropriate. Covers ovens designated to operate over all or part of the temperature range from 20 K above ambient to 500°C. Gives acceptance tests and in-service monitoring tests for both unloaded and loaded multi-chamber ovens and conditions of use.
Covers the minimum requirements for ventilated and heated multi-chamber ovens used for thermal endurance evaluation of electrical insulation and of any other appropriate thermal conditioning application where the use of single-chamber ovens is inappropriate. Covers ovens designated to operate over all or part of the temperature range from 20 K above ambient to 500°C. Gives acceptance tests and in-service monitoring tests for both unloaded and loaded multi-chamber ovens and conditions of use.
SIST EN 60216-4-3:2002 is classified under the following ICS (International Classification for Standards) categories: 25.180.10 - Electric furnaces; 29.035.01 - Insulating materials in general. The ICS classification helps identify the subject area and facilitates finding related standards.
You can purchase SIST EN 60216-4-3:2002 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of SIST standards.
Standards Content (Sample)
SLOVENSKI STANDARD
01-oktober-2002
Electrical insulating materials - Thermal endurance properties - Part 4-3: Ageing
ovens - Multi-chamber ovens (IEC 60216-4-3:2000)
Electrical insulating materials - Thermal endurance properties -- Part 4-3: Ageing ovens -
Multi-chamber ovens
Elektroisolierstoffe - Thermische Langzeiteigenschaften -- Teil 4-3:
Alterungswärmeschränke - Mehrkammerwärmeschränke
Matériaux isolants électriques - Propriétés d'endurance thermique -- Partie 4-3: Etuves
de vieillissement - Etuves à chambres multiples
Ta slovenski standard je istoveten z: EN 60216-4-3:2000
ICS:
25.180.10 (OHNWULþQHSHþL Electric furnaces
29.035.01 Izolacijski materiali na Insulating materials in
splošno general
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
--------
...
The article discusses the minimum requirements for multi-chamber ovens that are used to evaluate the thermal endurance properties of electrical insulation materials. These ovens are designed to operate within a specified temperature range and are used when single-chamber ovens are not suitable for the application. The article outlines acceptance tests and in-service monitoring tests for both unloaded and loaded multi-chamber ovens, as well as the conditions under which they should be used.
기사 제목: SIST EN 60216-4-3:2002 - 전기 절연재 - 열 내구성 특성 - 제4-3부: 노화 오븐 - 다중 챔버 오븐 기사 내용: 전기 절연물의 열내구성 평가 및 다른 적절한 열 조건부용도에 사용되는 환기 및 가열된 다중 챔버 오븐의 최소 요구 사항을 다룹니다. 20 K 위의 주변온도부터 500°C까지의 온도 범위 전체 또는 일부에서 동작하는 오븐을 다룹니다. 미사용 및 사용 중인 다중 챔버 오븐 및 사용 조건에 대한 수용 시험과 사용 중 모니터링 시험을 제공합니다.
記事のタイトル:SIST EN 60216-4-3:2002 - 電気絶縁材料 - 熱耐久性特性 - 第4-3部:エージングオーブン - マルチチャンバーオーブン 記事の内容:電気絶縁材料の熱耐久性評価および他の適切な熱処理応用に使用される換気および加熱マルチチャンバーオーブンの最小要件について説明しています。周囲温度よりも20 K以上500°C以下の温度範囲で動作するオーブンを対象としています。荷重ありと荷重なしのマルチチャンバーオーブンの受け入れ試験および稼働中のモニタリング試験、使用条件について取り上げています。










Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...