Safety rules for the construction and installation of lifts - Particular applications to passenger lifts and goods passenger lifts - Part 71: Vandal resistant lifts

This document gives requirements in order to ensure the safety of persons when using lifts which are subject to different expected levels of vandalism:
-   Category 1, where lifts are in general public, in locations which are unobserved and limited acts of vandalism might occur, e.g. an enclosed lift in a shopping center;
-   Category 2, where lifts are in general public, in locations which are unobserved where stronger acts of vandalism can be expected e.g. a lift in a public car park.
NOTE   See Annex A for further information with regard to the selection of the vandal resistance category to be applied.
This document is not applicable to lifts installed before the date of its publication.

Sicherheitsregeln für die Konstruktion und den Einbau von Aufzügen - Besondere Anwendungen für Personen- und Lastenaufzüge - Teil 71: Schutzmaßnahmen gegen mutwillige Zerstörung

Dieses Dokument enthält Anforderungen, um die Sicherheit von Personen bei der Benutzung von Aufzügen zu gewährleisten, die einem unterschiedlichen erwarteten Grad an Vandalismus ausgesetzt sind:
-   Kategorie 1, wo Aufzüge für die Allgemeinheit zugänglich sind, an Orten, die unbeobachtet sind und wo in begrenztem Umfang Vandalismus vorkommen kann, z. B. ein geschlossener Aufzug in einem Einkaufszentrum;
-   Kategorie 2, wo Aufzüge in der Öffentlichkeit stehen, an unbeobachteten Orten, wo mit stärkeren Vandalismusakten zu rechnen ist, z.B. ein Aufzug in einem öffentlichen Parkhaus
ANMERKUNG   Anhang A gibt zusätzliche Informationen bezüglich der Auswahl der anzuwendenden Vandalensicherheitskategorie.
Dieses Dokument kann nicht angewendet werden für Aufzüge, die vor der Veröffentlichung installiert wurden.

Règles de sécurité pour la construction et l'installation des élévateurs - Applications particulières pour les ascenseurs et ascenseurs de charge - Partie 71 : Ascenseurs résistants aux actes de vandalisme

Le présent document spécifie des exigences afin de garantir la sécurité des personnes lorsqu’elles utilisent des ascenseurs sujets à différents niveaux prévisibles de vandalisme :
-   la catégorie 1 : les ascenseurs, tout public, sont situés dans des lieux non surveillés où des actes de vandalisme restreints peuvent survenir, par exemple tout ascenseur dans une gaine fermée, dans un centre commercial ;
-   la catégorie 2 : les ascenseurs, tout public, sont situés dans des lieux non surveillés où des actes de vandalisme majeurs peuvent survenir, par exemple tout ascenseur dans un parking public.
NOTE   Voir l’Annexe A pour de plus amples informations sur le choix de la catégorie de résistance aux actes de vandalisme à appliquer.
Le présent document ne s’applique pas aux ascenseurs installés avant sa date de publication.

Varnostna pravila za konstruiranje in vgradnjo dvigal (liftov) - Posebne izvedbe osebnih in osebno-tovornih dvigal - 71. del: Dvigala, odporna proti vandalizmu

Ta dokument vsebuje zahteve za zagotavljanje varnosti oseb pri uporabi dvigal, ki so izpostavljena različnim pričakovanim ravnem vandalizma:
–   1. kategorija, pri kateri so dvigala na splošno javna, na nenadzorovanih lokacijah, kjer lahko pride do omejenega vandalizma, npr. zaprto dvigalo v nakupovalnem središču;
–   2. kategorija, pri kateri so dvigala na splošno javna, na nenadzorovanih lokacijah, kjer je pričakovati izrazitejši vandalizem, npr. dvigalo v javni parkirni hiši.
OPOMBA:   Glej dodatek A z več informacijami o izbiri kategorije odpornosti proti vandalizmu, ki jo je treba upoštevati.
Ta dokument se ne uporablja za dvigala, vgrajena pred datumom njegove objave.

General Information

Status
Published
Public Enquiry End Date
20-Dec-2020
Publication Date
21-Aug-2022
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
07-Jun-2022
Due Date
12-Aug-2022
Completion Date
22-Aug-2022

Relations

Buy Standard

Standard
EN 81-71:2022
English language
30 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Draft
prEN 81-71:2020
English language
29 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 81-71:2022
01-september-2022
Nadomešča:
SIST EN 81-71:2018+AC:2019
Varnostna pravila za konstruiranje in vgradnjo dvigal (liftov) - Posebne izvedbe
osebnih in osebno-tovornih dvigal - 71. del: Dvigala, odporna proti vandalizmu
Safety rules for the construction and installation of lifts - Particular applications to
passenger lifts and goods passenger lifts - Part 71: Vandal resistant lifts
Sicherheitsregeln für die Konstruktion und den Einbau von Aufzügen - Besondere
Anwendungen für Personen- und Lastenaufzüge - Teil 71: Schutzmaßnahmen gegen
mutwillige Zerstörung
Règles de sécurité pour la construction et l'installation des élévateurs - Applications
particulières pour les ascenseurs et ascenseurs de charge - Partie 71 : Ascenseurs
résistants aux actes de vandalisme
Ta slovenski standard je istoveten z: EN 81-71:2022
ICS:
13.310 Varstvo pred kriminalom Protection against crime
91.140.90 Dvigala. Tekoče stopnice Lifts. Escalators
SIST EN 81-71:2022 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN 81-71:2022

---------------------- Page: 2 ----------------------
SIST EN 81-71:2022


EN 81-71
EUROPEAN STANDARD

NORME EUROPÉENNE

May 2022
EUROPÄISCHE NORM
ICS 91.140.90 Supersedes EN 81-71:2018+AC:2019
English Version

Safety rules for the construction and installation of lifts -
Particular applications to passenger lifts and goods
passenger lifts - Part 71: Vandal resistant lifts
Règles de sécurité pour la construction et l'installation Sicherheitsregeln für die Konstruktion und den Einbau
des élévateurs - Applications particulières pour les von Aufzügen - Besondere Anwendungen für
ascenseurs et les ascenseurs de charge - Partie 71 : Personen- und Lastenaufzüge - Teil 71:
Ascenseurs résistant aux actes de vandalisme Schutzmaßnahmen gegen mutwillige Zerstörung
This European Standard was approved by CEN on 20 April 2022.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.

This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.





EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2022 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 81-71:2022 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------
SIST EN 81-71:2022
EN 81-71:2022 (E)
Contents Page
European foreword . 4
Introduction . 5
1 Scope . 6
2 Normative references . 6
3 Terms and definitions . 6
4 List of significant hazards . 7
5 Safety requirements and/or protective measures . 8
5.1 General . 8
5.2 Lift well . 8
5.2.1 Well enclosure . 8
5.2.2 Access and emergency doors - Access trap doors - Inspection doors . 8
5.2.3 Ventilation . 9
5.3 Machinery spaces, pulley rooms and machinery cabinets . 9
5.4 Landing and car doors . 10
5.4.2 Landing door security system - Category 2 lifts . 11
5.4.3 Door coupling mechanism . 11
5.4.4 Door reversal mechanism . 12
5.4.5 Locking of car doors . 12
5.4.6 Manipulation of door operator and locks . 12
5.5 Car . 12
5.5.1 Car bodywork, Interior and fixings . 12
5.5.2 Car emergency doors and access trap doors . 13
5.5.3 Car ventilation . 13
5.5.4 Car lighting . 13
5.6 Car and landing controls and control stations . 13
5.6.1 Car and landing controls . 13
5.6.2 Car and Landing Control Stations . 13
5.6.3 Position indicators . 14
5.7 Alarm sounder . 14
5.8 Steel work . 14
5.9 Signs and markings . 14
6 Verification of safety requirements and/or protective measures . 15
7 Information for use . 17
Annex A (informative) Guidance to the selection of lift category . 18
A.1 General . 18
A.2 Examples of different user types . 18
A.3 Other considerations . 19
A.4 Lift performance . 19
A.5 Corrosion protection. 20
A.6 Durability of finishes . 20
A.7 Protection of power supplies . 20
Annex B (normative) Impact test . 21
2

---------------------- Page: 4 ----------------------
SIST EN 81-71:2022
EN 81-71:2022 (E)
B.1 Equipment . 21
B.2 Samples . 21
B.3 Method . 21
B.4 Result . 21
Annex C (normative) Information sign for landing door security system . 22
Annex D (informative) Additional advice for dealing with vandalism . 23
Annex E (normative) Typical items used in vandalism . 24
Annex F (normative) Fire tests . 26
F.1 Equipment . 26
F.2 Samples . 26
F.3 Method . 26
F.4 Results . 26
Annex ZA (informative) Relationship between this European Standard and the essential
requirements of Directive 2014/33/EU aimed to be covered . 28
Bibliography . 30

3

---------------------- Page: 5 ----------------------
SIST EN 81-71:2022
EN 81-71:2022 (E)
European foreword
This document (EN 81-71:2022) has been prepared by Technical Committee CEN/TC 10 “Lifts, escalators
and moving walks”, the secretariat of which is held by AFNOR.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by November 2022, and conflicting national standards shall
be withdrawn at the latest by May 2024.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN 81-71:2018+AC:2019.
In comparison with the previous edition, the following significant changes have been made:
— reference to Category 0 has been removed;
— normative references have been updated;
— Annex ZA has been modified.
No technical changes have been made in Clause 5 during this revision.
This document is intended to be used in conjunction with EN 81-20:2020, which gives the basic
requirements for passenger and goods passenger lifts.
This document is part of the EN 81 series of standards. The structure of the EN 81 series is described in
CEN/TR 81-10:2008.
This document has been prepared under a Standardization Request given to CEN by the European
Commission and the European Free Trade Association, and supports essential requirements of EU
Directive(s) / Regulation(s).
For relationship with EU Directive(s) / Regulation(s), see informative Annex ZA, which is an integral part
of this document.
Any feedback and questions on this document should be directed to the users’ national standards body.
A complete listing of these bodies can be found on the CEN website.
According to the CEN-CENELEC Internal Regulations, the national standards organisations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia,
Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland,
Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of North
Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United
Kingdom.
4

---------------------- Page: 6 ----------------------
SIST EN 81-71:2022
EN 81-71:2022 (E)
Introduction
This document is a type-C standard as stated in EN ISO 12100.
This document is of relevance, in particular, for the following stakeholder groups representing the market
players with regard to machinery safety:
— machine manufacturers (small, medium and large enterprises);
— health and safety bodies (regulators, accident prevention organizations, market surveillance, etc.).
Others can be affected by the level of machinery safety achieved with the means of the document by the
above-mentioned stakeholder groups:
— machine users/employers (small, medium and large enterprises);
— machine users/employees (e.g. trade unions, organizations for people with special needs);
— service providers, e.g. for maintenance (small, medium and large enterprises);
— consumers (in case of machinery intended for use by consumers).
The above-mentioned stakeholder groups have been given the possibility to participate in the drafting
process of this document.
The machinery concerned and the extent to which hazards, hazardous situations or hazardous events are
covered are indicated in the Scope of this document.
When requirements of this type-C standard are different from those which are stated in type-A or type-B
standards, the requirements of this type-C standard take precedence over the requirements of the other
standards for machines that have been designed and built according to the requirements of this type-C
standard.
This document provides requirements for the design of lifts where it is considered that additional
measures are required in order to protect against the risk of vandalism. Every lift is subject to some
amount of careless and rough use. Additional protective measures against deliberate acts that may result
in equipment damage or injury to persons are referred to in this document as Category 1 or Category 2.
The following assumptions were made whilst writing this document:
— The potential for vandalism of lifts depends on the following factors:
— access to the lift installation;
— the surrounding area;
— observation of the lift by others in the vicinity;
— the extent of building security and surveillance of the lift;
— period of access to the building, including the lift (24 h);
— vulnerability of lift.
— The forces exerted on the lift and its equipment will be as a result of manual effort or by item(s) such
as those listed in Annex E.
5

---------------------- Page: 7 ----------------------
SIST EN 81-71:2022
EN 81-71:2022 (E)
1 Scope
This document defines requirements addressing the significant hazards related to lifts, which are subject
to different expected levels of vandalism (see Annex A and Annex D for further information).
Those requirements are supplementary (additional and/or modified) to the requirements of EN 81-
20:2020, intended to mitigate the effect of vandalism.
This document is not applicable to lifts installed before the date of its publication.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 81-20:2020, Safety rules for the construction and installation of lifts — Lifts for the transport of persons
and goods — Part 20: Passenger and goods passenger lifts
EN 81-28:2022, Safety rules for the construction and installation of lifts — Lifts for the transport of persons
and goods — Part 28: Remote alarm on passenger and goods passenger lifts
EN 81-72:2020, Safety rules for the construction and installation of lifts — Particular applications for
passenger and goods passenger lifts — Part 72: Firefighters lifts
EN 81-73:2020, Safety rules for the construction and installation of lifts — Particular applications for
passenger and goods passenger lifts — Part 73: Behaviour of lifts in the event of fire
EN 13501-1:2018, Fire classification of construction products and building elements — Part 1:
Classification using data from reaction to fire tests
1
EN 60529:1991, Degrees of protection provided by enclosures (IP Code) (IEC 60529:1989)
EN ISO 12100:2010, Safety of machinery — General principles for design — Risk assessment and risk
reduction (ISO 12100:2010)
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN ISO 12100:2010, EN 81-20:2020
and the following apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https://www.iso.org/obp
— IEC Electropedia: available at https://www.electropedia.org/
3.1
car ceiling
parts of the car roof accessible from inside the car

1
As impacted by EN 60529:1991/A1:2000, EN 60529:1991/A2:2013 and EN 60529:1991/A2:2013/AC:2019-02.
6

---------------------- Page: 8 ----------------------
SIST EN 81-71:2022
EN 81-71:2022 (E)
3.2
category 1 lift
lift which is protected against limited act of vandalism
Note 1 to entry: For guidance on selection of the relevant category see Annex A.
3.3
category 2 lift
lift which is protected against strong act of vandalism
Note 1 to entry: For guidance on selection of the relevant category see Annex A.
4 List of significant hazards
This clause contains all the significant hazards, hazardous situations and events, as far as they are dealt
with in this document, identified by risk assessment as significant for this type of lift and which require
action to eliminate or reduce the risk (see Table 1).
Table 1 — List of significant hazards
Hazards as listed in EN ISO 12100:2010, Relevant clauses
Annex B
Mechanical hazards due to:
− Crushing 5.2.1.2, 5.2.1.3, 5.2.2.1, 5.2.2.2, 5.3.5, 5.4.2.1, 5.4.2.4
and 5.5.2
− Shearing 5.2.1.1, 5.2.1.2, 5.2.1.3, 5.2.2.1, 5.2.2.2, 5.2.3, 5.3.1,
5.3.2, 5.3.3, 5.3.4, 5.3.5, 5.4.1.2, 5.4.1.3, 5.4.1.4,
5.4.1.6, 5.4.2.1, 5.4.2.4, 5.5.1.1 and 5.5.2
− Cutting 5.4.1.2, 5.5.1.8, 5.5.4, 5.6.1.3 and 5.6.2.1
− Trapping 5.4.2.3, 5.4.2.4, 5.4.2.5, 5.4.5 and 5.7
− Impact hazard 5.4.4
− Slipping, tripping and falling 5.2.1.1, 5.2.2.2, 5.2.3, 5.3.3, 5.3.4, 5.3.5, 5.3.6, 5.4.1.2,
5.4.1.3, 5.4.2.1, 5.4.2.3, 5.4.2.4, 5.4.6, 5.5.1.1, 5.5.1.6,
5.5.2 and 5.8
Electrical hazards due to live parts 5.5.1.9, 5.5.4, 5.6.1.1, 5.6.1.3, 5.6.1.4 and 5.6.2.1
Thermal hazards due to flame 5.2.1.1, 5.3.1, 5.3.7, 5.4.1.1, 5.5.1.4, 5.5.4, 5.6.1.1,
5.6.1.5 and 5.9
Hazards due to human behaviour 5.2.1.1, 5.2.1.2, 5.2.1.3, 5.2.2.1, 5.2.2.2, 5.2.3, 5.3.1,
5.3.2, 5.3.3, 5.3.4, 5.3.5, 5.3.6, 5.4.1.5, 5.4.1.6, 5.4.1.7,
5.4.1.8, 5.4.2.1, 5.4.2.3, 5.4.3, 5.4.4, 5.4.5, 5.4.6,
5.5.1.1, 5.5.1.2, 5.5.1.3, 5.5.1.5, 5.5.1.7, 5.5.1.8,
5.5.1.9, 5.5.2, 5.5.3, 5.5.4, 5.6.1.2, 5.6.1.3, 5.6.1.4,
5.6.2.1, 5.6.2.2, 5.7 and 5.9
7

---------------------- Page: 9 ----------------------
SIST EN 81-71:2022
EN 81-71:2022 (E)
5 Safety requirements and/or protective measures
5.1 General
Category 1 and Category 2 lifts shall comply with the safety requirements and/or protective measures of
the following clauses. Where a category is specified, the subclause applies to that category only. In
addition, lifts shall be designed according to the principles of EN ISO 12100:2010 for hazards relevant
but not significant that are not dealt with by this document.
5.2 Lift well
5.2.1 Well enclosure
5.2.1.1 Well enclosures shall be imperforate. The walls, floor and ceiling shall be made of materials
such as steel, brick, concrete, etc. with a mechanical strength such that when a force of 2 500 N being
2
evenly distributed over an area of 100 cm in round or square section is applied at right angles to the
surface at any point on either face they shall resist without:
a) permanent deformation;
b) elastic deformation greater than 15 mm.
The materials used for the well enclosure shall be non-combustible, e.g. according to Class A1 of
EN 13501-1:2018.
If the material used is glass, it shall be of an equivalent strength to the glass used for landing doors –
see 5.4.1.
5.2.1.2 For Category 1 lifts with a partially enclosed well the height of the enclosure according
to EN 81-20:2020, 5.2.5.2.3 b) shall be a minimum of 5,0 m.
5.2.1.3 Category 2 lifts shall be provided with a totally enclosed well.
5.2.2 Access and emergency doors - Access trap doors - Inspection doors
5.2.2.1 Access and emergency doors, access trap doors and inspection doors shall be of such a
construction that it is not possible to open them with any of the items as listed in Table E.1.
5.2.2.2 Access and emergency doors, access trap doors and inspection doors in their locked position
shall withstand a force of 2 500 N applied:
— from the side which is normally accessible to persons,
— at right angles to the panel,
— at any point on the exposed face,
2
— evenly distributed over an area of 100 cm of round or square section;
they shall:
a) resist the force without permanent deformation;
b) resist without elastic deformation greater than 15 mm;
c) not have their safety function affected during and after such a test;
8

---------------------- Page: 10 ----------------------
SIST EN 81-71:2022
EN 81-71:2022 (E)
d) operate afterwards.
5.2.3 Ventilation
Ventilation openings shall be in accordance with 5.3.3 and 5.3.4.
5.3 Machinery spaces, pulley rooms and machinery cabinets
5.3.1 The materials used in the construction of any machinery space, pulley room or machinery cabinet
outside of the well shall comply with 5.2.1.1.
5.3.2 Windows, if provided and accessible to persons, shall:
a) be of a strength as specified in 5.2.2.2;
b) have laminated glass panel(s).
Windows are not recommended.
5.3.3 If ventilation openings are accessible to persons from the outside, individual openings shall:
a) not be greater than 250 mm × 250 mm;
b) be provided with a means of protection so that a straight rod of any cross section, shall not pass
through.
5.3.4 The means of protection in 5.3.3 shall be of a strength as specified in 5.2.1.1.
5.3.5 Doors and access trap doors with their locks shall meet the requirements of 5.2.2.2.
5.3.6 For Category 2 lifts, an intruder alarm system shall operate if any of the following doors are
opened:
— machine room and/or pulley room door;
— inspection doors, emergency doors and access trap doors;
— machinery cabinet doors.
The intruder alarm system shall operate an audible alarm within 30 s after opening any of the above
doors.
The audible alarm shall:
a) be audible at both the point of intrusion and at the main access floor, with an adjustable sound level
between 70 dB(A) and 85 dB(A);
b) stop automatically after an adjustable period between 5 min and 15 min.
It shall be possible to deactivate and re-activate the alarm system by the device referred to in 5.4.2.2.
In the event of loss of the electrical supply, the alarm system shall remain operative for at least two hours.
5.3.7 In the case of a Category 2 lift, machinery located in the pit, e.g. machine, tank, controller, shall be
covered with a metallic enclosure. This enclosure is to prevent rubbish from entering the equipment and
causing dangerous malfunctions or the ignition of the material or the creation of smoke.
9

---------------------- Page: 11 ----------------------
SIST EN 81-71:2022
EN 81-71:2022 (E)
5.4 Landing and car doors
5.4.1 Landing and car doors shall be of the automatically horizontally sliding power operated type.
5.4.1.1 Materials used for car and landing doors shall comply with the following:
a) with the exception of decorative finishes, the materials used for door panels and frames/architraves
shall be non-combustible according to Class A1 or A2 of EN 13501-1:2018;
b) for Category 2 lifts the materials used for decorative finishes shall be non-combustible according to
Class A1 or A2 of EN 13501-1:2018.
5.4.1.2 Independently of their material, landing and car door assemblies, together with their frames
and fixings shall withstand the soft pendulum shock test as specified in EN 81-20:2020, 5.3.5.3.4 a)
without component failure or permanent deformation which would affect the proper function of the
doors, but with the pendulum fall height as:
a) for Category 1 lifts: 700 mm;
b) for Category 2 lifts: 1 000 mm.
The door assemblies shall remain operative after the test.
5.4.1.3 Door panels with their retainers shall withstand the soft pendulum shock test as specified in
EN 81-20:2020, 5.3.5.3.2 with a falling height increased to 1 400 mm.
5.4.1.4 For Category 2 lifts glass panels shall not be used.
5.4.1.5 For Category 2 lifts, the distance between each landing door panel, or its attachments at the
leading edge, and the car door(s) panel(s), or its attachments at the leading edge, shall not exceed 35 mm.
This distance shall be maintained back from the leading edge over a length of not less than 75 mm and
returned at an angle not exceeding 45° to the rear of the door panel. This return angle may be omitted
over a length not exceeding 200 mm at the top and/or bottom of the door panel to allow the fixing of door
equipment. Where the distance is maintained back for a length of 200 mm or more, then the return angle
is not required (see Figure 1).
Dimensions in millimetres

Key
1 direction of closing
2 return angle: maximum 45°
Figure 1 — Plan view of door panel with angled return
10

---------------------- Page: 12 ----------------------
SIST EN 81-71:2022
EN 81-71:2022 (E)
5.4.1.6 For Category 2 lifts, in addition to the requirements of EN 81-20:2020, 5.3.5.3.3, it shall not
be possible to pass a rod of 10 mm diameter directly from the landing side of the entrance into the well.
5.4.1.7 For Category 2 lifts, where panels are mechanically linked, the linkage shall be so designed or
located that it cannot be disengaged by a user, with an item as described in Annex E within a period of
60 s.
5.4.1.8 For Category 2 lifts, the leading-edge profile of the car and landing door panels shall be
formed as an integral part of the door panels.
5.4.2 Landing door security system - Category 2 lifts
5.4.2.1 At any floor where the car is not present, a security system shall prevent opening the landing
door with an emergency unlocking key as stated in EN 81-20:2020, 5.3.9.3.1 or by using an item as
described in Annex E, unless this system has been de-activated.
5.4.2.2 A device to manually activate and de-activate the system shall be in at least one of the
following locations:
a) the machine room;
b) control cabinet;
c) emergency and inspection panel.
The device shall be clearly marked with a pictogram as shown in Annex C. The pictogram shall also be
located on or adjacent to the lif
...

SLOVENSKI STANDARD
oSIST prEN 81-71:2020
01-december-2020
Varnostna pravila za konstruiranje in vgradnjo dvigal (liftov) - Posebne izvedbe
osebnih in osebno-tovornih dvigal - 71. del: Dvigala, odporna proti vandalizmu
Safety rules for the construction and installation of lifts - Particular applications to
passenger lifts and goods passenger lifts - Part 71: Vandal resistant lifts
Sicherheitsregeln für die Konstruktion und den Einbau von Aufzügen - Besondere
Anwendungen für Personen- und Lastenaufzüge - Teil 71: Schutzmaßnahmen gegen
mutwillige Zerstörung
Règles de sécurité pour la construction et l'installation des élévateurs - Applications
particulières pour les ascenseurs et ascenseurs de charge - Partie 71 : Ascenseurs
résistants aux actes de vandalisme
Ta slovenski standard je istoveten z: prEN 81-71
ICS:
13.310 Varstvo pred kriminalom Protection against crime
91.140.90 Dvigala. Tekoče stopnice Lifts. Escalators
oSIST prEN 81-71:2020 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
oSIST prEN 81-71:2020

---------------------- Page: 2 ----------------------
oSIST prEN 81-71:2020


DRAFT
EUROPEAN STANDARD
prEN 81-71
NORME EUROPÉENNE

EUROPÄISCHE NORM

October 2020
ICS 91.140.90 Will supersede EN 81-71:2018+AC:2019
English Version

Safety rules for the construction and installation of lifts -
Particular applications to passenger lifts and goods
passenger lifts - Part 71: Vandal resistant lifts
Règles de sécurité pour la construction et l?installation Sicherheitsregeln für die Konstruktion und den Einbau
des élévateurs - Applications particulières pour les von Aufzügen - Besondere Anwendungen für
ascenseurs et ascenseurs de charge - Partie 71 : Personen- und Lastenaufzüge - Teil 71:
Ascenseurs résistants aux actes de vandalisme Schutzmaßnahmen gegen mutwillige Zerstörung
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 10.

If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.


EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2020 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 81-71:2020 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------
oSIST prEN 81-71:2020
prEN 81-71:2020 (E)
Contents Page
European foreword . 3
Introduction . 4
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 5
4 List of significant hazards . 6
5 Safety requirements and/or protective measures . 6
5.1 General . 6
5.2 Lift well . 6
5.2.1 Well enclosure . 6
5.2.2 Access and emergency doors - Access trap doors - Inspection doors . 7
5.2.3 Ventilation . 7
5.3 Machinery spaces, pulley rooms and machinery cabinets . 7
5.4 Landing and car doors . 8
5.4.2 Landing door security system – Category 2 lifts . 9
5.4.3 Door coupling mechanism . 10
5.4.4 Door reversal mechanism . 10
5.4.5 Locking of car doors. 10
5.4.6 Manipulation of door operator and locks . 10
5.5 Car . 10
5.5.1 Car bodywork, Interior and fixings . 10
5.5.2 Car emergency doors and access trap doors . 11
5.5.3 Car ventilation . 11
5.5.4 Car lighting . 11
5.6 Car and landing controls and control stations . 12
5.6.1 Car and landing controls . 12
5.6.2 Car and Landing Control Stations . 12
5.6.3 Position indicators . 12
5.7 Alarm sounder . 12
5.8 Steel work . 12
5.9 Signs and markings . 13
6 Verification of safety requirements and / or protective measures . 13
7 Information for use . 16
Annex A (informative) Guidance to the selection of vandal resistance category . 17
Annex B (normative) Impact test . 20
Annex C (normative) Information sign for landing door security system . 21
Annex D (informative) Additional advice for dealing with vandalism . 22
Annex E (normative) Typical items used in vandalism . 23
Annex F (normative) Fire tests . 25
Annex ZA (informative) Relationship between this European Standard and the
essential requirements of Directive 2014/33/EU aimed to be covered . 27
Bibliography . 29

2

---------------------- Page: 4 ----------------------
oSIST prEN 81-71:2020
prEN 81-71:2020 (E)
European foreword
This document (prEN 81-71:2020) has been prepared by Technical Committee CEN/TC 10 “Lifts,
escalators and moving walks”, the secretariat of which is held by AFNOR.
This document is currently submitted to the CEN Enquiry.
This document has been prepared under a mandate given to CEN by the European Commission and
the European Free Trade Association, and supports essential requirements of EU Directive(s).
For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this
document.
This document will supersede EN 81-71:2018+A1:2019.
In comparison with the previous edition, the following significant changes have been made:
— The removal of reference to Category 0;
— All externally referenced standards have now been dated;
— Editorial corrections to assist in understanding;
— A new Annex ZA has been developed in order to be aligned with the requirements of the EU
Commission Standardization Request “M/549 C(2016) 5884 final”.
No technical changes have been made during this revision.
The content of this document provides the enhanced design rules, examinations and tests for lifts
where protection is needed against vandalism.
This document is intended to be used in conjunction with the EN 81-20:2020, which gives the basic
requirements for passenger and goods passenger lifts.
This document is part of the EN 81 series of standards. The structure of the EN 81 series is described
in CEN/TR 81-10:2008.
3

---------------------- Page: 5 ----------------------
oSIST prEN 81-71:2020
prEN 81-71:2020 (E)
Introduction
This document is a type-C standard as stated in EN ISO 12100:2010.
The lifts concerned and the extent to which hazards, hazardous situations or hazardous events are
covered are indicated in the Scope of this document.
When requirements of this type-C standard are different from those which are stated in type-A or
type-B standards, the requirements of this type-C standard take precedence over the requirements
of the other standards for machines that have been designed and built according to the requirements
of this type-C standard.
This document provides requirements for the design of lifts where it is considered that additional
measures are required in order to protect against the risk of vandalism. Every lift is subject to some
amount of careless and rough use. Additional protective measures against deliberate acts that may
result in equipment damage or injury to persons for lifts are referred to in this document as Category
1 or Category 2.
The following assumptions were made whilst writing this document:
— The potential for vandalism of lifts depends on the following factors:
— the degree of accessibility to the lift installation;
— the surrounding area;
— observation of the lift by others in the vicinity;
— the extent of building security and surveillance of the lift;
— period of access to the building, including the lift (24 h);
— vulnerability of lift.
— The forces exerted on the lift and its equipment will be as a result of manual effort or by item(s)
such as those listed in Annex E.
4

---------------------- Page: 6 ----------------------
oSIST prEN 81-71:2020
prEN 81-71:2020 (E)
1 Scope
This document gives requirements in order to ensure the safety of persons when using lifts which
are subject to different expected levels of vandalism:
— Category 1, where lifts are in general public, in locations which are unobserved and limited acts
of vandalism might occur, e.g. an enclosed lift in a shopping center;
— Category 2, where lifts are in general public, in locations which are unobserved where stronger
acts of vandalism can be expected e.g. a lift in a public car park.
NOTE See Annex A for further information with regard to the selection of the vandal resistance category
to be applied.
This document is not applicable to lifts installed before the date of its publication.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments)
applies.
EN 81-20:2020, Safety rules for the construction and installation of lifts - Lifts for the transport of
persons and goods - Part 20: Passenger and goods passenger lifts
EN 81-72:2020, Safety rules for the construction and installation of lifts - Particular applications for
passenger and goods passenger lifts - Part 72: Firefighters lifts
EN 81-73:2020, Safety rules for the construction and installation of lifts - Particular applications for
passenger and goods passenger lifts - Part 73: Behaviour of lifts in the event of fire
EN 13501-1:2018, Fire classification of construction products and building elements - Part 1:
Classification using data from reaction to fire tests
1)
EN 60529:1991 , Degrees of protection provided by enclosures (IP Code) (IEC 60529:1989)
EN ISO 12100:2010, Safety of machinery - General principles for design - Risk assessment and risk
reduction (ISO 12100:2010)
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN ISO 12100:2010,
EN 81-20:2020 and the following apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:

— IEC Electropedia: available at http://www.electropedia.org/
— ISO Online browsing platform: available at http://www.iso.org/obp
3.1
car ceiling
parts of the car roof accessible from inside the car

1) As impacted by EN 60529:1991/A1:2000 and EN 60529:1991/A2:2013.
5

---------------------- Page: 7 ----------------------
oSIST prEN 81-71:2020
prEN 81-71:2020 (E)
4 List of significant hazards
This clause contains all the significant hazards, hazardous situations and events, as far as they are
dealt with in this document, identified by risk assessment as significant for this type of lift and which
require action to eliminate or reduce the risk (see Table 1).
Table 1 — List of significant hazards
Hazards as listed in EN ISO 12100:2010, Relevant clauses
Annex B
Mechanical hazards due to:
− Crushing 5.2.1.2, 5.2.1.3, 5.2.2.1, 5.2.2.2, 5.3.5, 5.4.2.1, 5.4.2.4
and 5.5.2
− Shearing 5.2.1.1, 5.2.1.2, 5.2.1.3, 5.2.2.1, 5.2.2.2, 5.2.3, 5.3.1,
5.3.2, 5.3.3, 5.3.4, 5.3.5, 5.4.1.2, 5.4.1.3, 5.4.1.4,
5.4.1.6, 5.4.2.1, 5.4.2.4, 5.5.1.1 and 5.5.2
− Cutting 5.4.1.2, 5.5.1.8, 5.5.4, 5.6.1.3 and 5.6.2.1
− Trapping 5.4.2.3, 5.4.2.4, 5.4.2.5, 5.4.5 and 5.7
− Impact hazard 5.4.4
− Slipping, tripping and falling 5.2.1.1, 5.2.2.2, 5.2.3, 5.3.3, 5.3.4, 5.3.5, 5.3.6, 5.4.1.2,
5.4.1.3, 5.4.2.1, 5.4.2.3, 5.4.2.4, 5.4.6, 5.5.1.1, 5.5.1.6,
5.5.2 and 5.8
Electrical hazards due to live parts 5.5.1.9, 5.5.4, 5.6.1.1, 5.6.1.3, 5.6.1.4 and 5.6.2.1
Thermal hazards due to flame 5.2.1.1, 5.3.1, 5.3.7, 5.4.1.1, 5.5.1.4, 5.5.4, 5.6.1.1,
5.6.1.5 and 5.9
Hazards due to human behaviour 5.2.1.1, 5.2.1.2, 5.2.1.3, 5.2.2.1, 5.2.2.2, 5.2.3, 5.3.1,
5.3.2, 5.3.3, 5.3.4, 5.3.5, 5.3.6, 5.4.1.5, 5.4.1.6, 5.4.1.7,
5.4.1.8, 5.4.2.1, 5.4.2.3, 5.4.3, 5.4.4, 5.4.5, 5.4.6,
5.5.1.1, 5.5.1.2, 5.5.1.3, 5.5.1.5, 5.5.1.7, 5.5.1.8,
5.5.1.9, 5.5.2, 5.5.3, 5.5.4, 5.6.1.2, 5.6.1.3, 5.6.1.4,
5.6.2.1, 5.6.2.2, 5.7 and 5.9
5 Safety requirements and/or protective measures
5.1 General
Category 1 and Category 2 vandal resistant lifts shall comply with the safety requirements and/or
protective measures of the following clauses. In addition, lifts shall be designed according to the
principles of EN ISO 12100:2010 for hazards relevant but not significant that are not dealt with by
this document.
5.2 Lift well
5.2.1 Well enclosure
5.2.1.1 Well enclosures shall be imperforate. The walls, floor and ceiling shall be made of
materials such as steel, brick, concrete etc. with a mechanical strength such that when a force of
2
2 500 N being evenly distributed over an area of 100 cm in round or square section is applied at
right angles to the surface at any point on either face they shall resist without:
6

---------------------- Page: 8 ----------------------
oSIST prEN 81-71:2020
prEN 81-71:2020 (E)
a) permanent deformation;
b) elastic deformation greater than 15 mm.
The materials used for the well enclosure shall be non-combustible, e.g. according to Class A1 of
EN 13501-1:2018.
If the material used is glass, it shall be of an equivalent strength to the glass used for landing doors –
see 5.4.1.
5.2.1.2 For Category 1 lifts with a partially enclosed well the height of the enclosure according
to EN 81-20:2020, 5.2.5.2.3 b) shall be a minimum of 5,0 m.
5.2.1.3 Category 2 lifts shall be provided with a totally enclosed well.
5.2.2 Access and emergency doors - Access trap doors - Inspection doors
5.2.2.1 Access and emergency doors, access trap doors and inspection doors shall be of such a
construction that it is not possible to open them with any of the items as listed in Table E.1.
5.2.2.2 Access and emergency doors, access trap doors and inspection doors with their locks
shall be of sufficient strength that, in the locked position when a force of 2 500 N (from the side which
is normally accessible to persons) is applied at right angles to the panel, at any point on the exposed
2
face, evenly distributed over an area of 100 cm of round or square section; they shall:
a) resist the force without permanent deformation;
b) resist without elastic deformation greater than 15 mm;
c) not have their safety function affected during and after such a test;
d) operate afterwards.
5.2.3 Ventilation
Ventilation openings shall be in accordance with 5.3.3 and 5.3.4.
5.3 Machinery spaces, pulley rooms and machinery cabinets
5.3.1 The materials used in the construction of any machinery space, pulley room or machinery
cabinet outside of the well shall comply with 5.2.1.1.
5.3.2 Windows, if provided and accessible to persons, shall:
a) be of a strength as specified in 5.2.2.2;
b) have laminated glass panel(s).
Windows are not recommended.
5.3.3 If ventilation openings are accessible to persons from the outside, individual openings shall:
a) not be greater than 250 mm × 250 mm;
b) be provided with a means of protection so that a straight rod of any cross section, shall not pass
through.
5.3.4 The means of protection in 5.3.3 shall be of a strength as specified in 5.2.1.1.
7

---------------------- Page: 9 ----------------------
oSIST prEN 81-71:2020
prEN 81-71:2020 (E)
5.3.5 Doors and access trap doors with their locks shall meet the requirements of 5.2.2.2.
5.3.6 For Category 2 lifts, an intruder alarm system shall operate if any of the following doors are
opened:
— machine room and/or pulley room door;
— inspection doors, emergency doors and access trap doors;
— machinery cabinet doors.
The intruder alarm system shall operate an audible alarm within 30 s after opening any of the above
doors.
The audible alarm shall:
a) be audible at both the point of intrusion and at the main access floor, with an adjustable sound
level between 70 dB(A) and 85 dB(A);
b) stop automatically after an adjustable period between 5 min and 15 min.
It shall be possible to deactivate and re-activate the alarm system by the device referred to in 5.4.2.2.
In the event of loss of the electrical supply, the alarm system shall remain operative for at least two
hours.
5.3.7 In the case of a Category 2 lift, machinery located in the pit, e.g. machine, tank, controller, shall
be covered with a metallic enclosure. This enclosure is to prevent rubbish from entering the
equipment and causing dangerous malfunctions or the ignition of the material or the creation of
smoke.
5.4 Landing and car doors
5.4.1 Landing and car doors shall be of the automatically horizontally sliding power operated type.
5.4.1.1 Materials used for car and landing doors shall comply with the following:
a) with the exception of decorative finishes, the materials used for door panels and
frames/architraves shall be non-combustible, e.g. according to Class A1 of EN 13501-1:2018;
b) for Category 2 lifts the materials used for decorative finishes shall be non-combustible according
to Class A1 or A2 of EN 13501-1:2018.
5.4.1.2 Independently of their material, landing and car door assemblies, together with their
frames and fixings shall withstand the soft pendulum shock test as specified in EN 81-20:2020,
5.3.5.3.4 a) without component failure or permanent deformation which would affect the proper
function of the doors, but with the pendulum fall height as:
a) for Category 1 lifts: 700 mm;
b) for Category 2 lifts: 1 000 mm.
The door assemblies shall remain operative after the test.
5.4.1.3 Door panels with their retainers shall withstand the soft pendulum shock test as specified
in EN 81-20:2020, 5.3.5.3.2 with a falling height increased to 1 400 mm.
8

---------------------- Page: 10 ----------------------
oSIST prEN 81-71:2020
prEN 81-71:2020 (E)
5.4.1.4 For Category 2 lifts glass panels shall not be used.
5.4.1.5 For Category 2 lifts, the distance between each landing door panel, or its attachments at
the leading edge, and the car door(s), or its attachments at the leading edge, shall not exceed 35 mm.
This distance shall be maintained back from the leading edge over a length of not less than 75 mm
and returned at an angle not exceeding 45° to the rear of the door panel. This return angle may be
omitted over a length not exceeding 200 mm at the top and/or bottom of the door panel to allow the
fixing of door equipment. Where the distance is maintained back for a length of 200 mm or more,
then the return angle is not required (see Figure 1).
Dimensions in millimetres

Key
1 direction of closing
2 return angle: maximum 45°
Figure 1 — Plan view of door panel with angled return
5.4.1.6 For Category 2 lifts, in addition to the requirements of EN 81-20:2020, 5.3.5.3.3, it shall
not be possible to pass a rod of 10 mm diameter directly from the landing side of the entrance into
the well.
5.4.1.7 For Category 2 lifts, where panels are mechanically linked, the linkage shall be so
designed or located that it cannot be disengaged by a user, with an item as described in Annex E
within a period of 60 s.
5.4.1.8 For Category 2 lifts, the leading edge profile of car and landing doors shall be formed as
an integral part of the door.
5.4.2 Landing door security system – Category 2 lifts
5.4.2.1 At any floor where the car is not present, a security system shall prevent opening the
landing door with an emergency unlocking key as stated in EN 81-20:2020, 5.3.9.3.1 or by using an
item as described in Annex E, unless this system has been de-activated.
5.4.2.2 A device to manually activate and de-activate the system shall be in at least one of the
following locations:
a) the machine room;
b) control cabinet;
c) emergency and inspection panel.
The device shall be clearly marked with a pictogram as shown in Annex C. The pictogram shall also
be located on or adjacent to the lift entrance at the main entry/exit floor of the building.
9

---------------------- Page: 11 ----------------------
oSIST prEN 81-71:2020
prEN 81-71:2020 (E)
5.4.2.3 After manual de-activation, the system shall be automatically re-activated after a period
of between 30 min and 60 min, to prevent the doors being left without the security system operative.
However, when the lift is placed on inspection control, or a stopping device to EN 81-20:2020,
5.12.1.11 is operated, this time sequence shall stop. Once the lift is returned to normal operation, the
time sequence shall be re-initiated. Each manual re-activation shall reduce any remaining time delay
to a value between 30 s and 60 s.
5.4.2.4 In the event of failure of the main power supply, the system shall remain operative for at
least two hours by means of a back-up power supply. In the event of disconnection of the main switch,
the system shall be immediately deactivated.
5.4.2.5 Where this system is installed for use in:
a) firefighters lifts in conformity with EN 81-72:2020, 5.8, it shall be automatically de-activated
when the lift is recalled (phase 1) or in firefighters control (phase 2);
b) lifts in conformity with EN 81-73:2020, 5.1, it shall be automatically de-activated when the lift is
recalled.
5.4.3 Door coupling mechanism
For Category 2 lifts, whilst the car is stationary in the unlocking zone it shall not be possible to de-
couple the car and landing doors by hand or the use of an item as described in Annex E within a
period of 60 s.
5.4.4 Door reversal mechanism
For Category 2 lifts, any protective devices for reversing the car and landing door movement when
closing shall be positioned such as to be inaccessible to unauthorised persons.
5.4.5 Locking of car doors
The car door(s) shall be provided with a mechanical locking device in compliance with
EN 81-20:2020, 5.3.9.2.
5.4.6 Manipulation of door operator and locks
For Category 2 lifts, in addition to the requirements of EN 81-20:2020, it shall not be possible to
manipulate the door operator and locks, to render them ineffective by use of any of the item
described in Annex E within 60 s.
5.5 Car
5.5.1 Car bodywork, Interior and fixings
5.5.1.1 The walls of the car shall have a mechanical strength at least equal to the landing doors
as specified in 5.4.1.2 a) or b) as applicable.
5.5.1.2 For Category 1 lifts, the car ceilings shall:
a) be able to support the mass of 150 kg at any point from which persons can suspend themselves;
b) be so fixed to prevent unauthorised displacement, within a period of 60 s, either by hand or the
use of items as described in Annex E.
5.5.1.3 For Category 2 lifts the ceiling shall be so designed that there are no points from which
persons can suspend themselves.
10

---------------------- Page: 12 ----------------------
oSIST prEN 81-71:2020
prEN 81-71:2020 (E)
5.5.1.4 Materials used for the car shall comply with the following:
a) the materials used for the car bodywork shall be non-combustible according to Class A1
of EN 13501-1:2018;
b) for Category 2 lifts, the materials used for ceiling and wall finishes shall be non-combustible
according to Class A2 of EN 13501-1:2018 and the materials used for the car flooring shall be
non-combustible according to Class A2 of EN 13501-1:2018.
fl
5.5.1.5 The car bodywork shall resist cutting through with items as identified in Annex E.
5.5.1.6 Any car flooring material shall be so fixed as to prevent the creation of a tripping hazard
when cut.
5.5.1.7 For Category 2 lifts, any handrail shall be capable of withstanding a force of 2 500 N
applied in any direction.
5.5.1.8 For Category 2 lifts, where a mirror is installed it shall:
a) be flush fitted;
b) be laminated if made of glass.
5.5.1.9 Elements, e.g. fixtures and fittings, that are accessible to users shall:
a) for Category 1 lifts, be removable by authorised persons;
b) for Category 2 lifts, be fitted with fixings that are not visible to users.
5.5.2 Car emergency doors and access trap doors
For Category 2 lifts any access trap doors or emergency doors shall meet the requirements of
EN 81-20:2020, 5.4.6 and be provided with a security system in accordance with 5.4.2.
NOTE It is advised that access trap doors and emergency doors are not provided unless called for by other
parts of the EN 81 series of standards.
5.5.3 Car ventilation
Any normally accessible car ventilation openings shall be provided with a means of protection so that
a straight rod of any cross section shall not pass through.
5.5.4 Car lighting
All light fixtures within the lift car shall:
a) be flush fitted without visible fixings and in a manner such as to prevent unauthorised access;
b) when tested as described in Annexes B and F remain functional and unbroken.
11

---------------------- Page: 13 ----------------------
oSIST prEN 81-71:2020
prEN 81-71:2020 (E)
5.6 Car and landing controls and control stations
5.6.1 Car and landing controls
5.6.1.1 When mounted in their assemblies control buttons, indicators and other fixtures, when