SIST EN 55016-4-2:2011/A1:2014
(Amendment)Specification for radio disturbance and immunity measuring apparatus and methods -- Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty
Specification for radio disturbance and immunity measuring apparatus and methods -- Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty
This part of CISPR 16-4 specifies the method of applying Measurement Instrumentation Uncertainty (MIU) when determining compliance with CISPR disturbance limits. The material is also relevant to any EMC test when interpretation of the results and conclusions reached will be impacted by the uncertainty of the measurement instrumentation used during testing. NOTE In accordance with IEC Guide 107, CISPR 16-4-2 is a basic EMC standard for use by product committees of the IEC. As stated in Guide 107, product committees are responsible for determining the applicability of the EMC standard. CISPR and its sub-committees are prepared to co-operate with technical committees and product committees in the evaluation of the applicability of this standard for specific products. The annexes contain the background material used in providing the amount of MIU found in generating the CISPR values shown in Clauses 4 through 8 and hence provide valuable background material for those needing both initial and further information on MIU and how to take individual uncertainties in the measurement chain into account. The annexes, however, are not intended to be a tutorial or user manual or to be copied when making uncertainty calculations. For that purpose, the references shown in the bibliography, or other widely
recognized documents, may be used. Measurement instrumentation specifications are given in the CISPR 16-1 series, while the methods of measurement are covered in the CISPR 16-2 series. Further information and background on CISPR and radio disturbances is given in CISPR 16-3. The other parts of the
CISPR 16-4 series contain further information on uncertainties in general, statistics and limit modelling. See the introduction of this part for more information on the background and on the content of the CISPR 16-4 series.
Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Teil 4-2: Unsicherheiten, Statistik und Modelle zur Ableitung von Grenzwerten (Störmodell) - Messgeräte-Unsicherheit
Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques -- Partie 4-2: Incertitudes, statistiques et modélisation des limites - Incertitudes de mesure de l'instrumentation
Specifikacija za merilne naprave in metode za merjenje radijskih motenj in odpornosti - 4-2. del: Modeliranje negotovosti, statistike in mejnih vrednosti - Negotovost merilnih instrumentov - Dopolnilo A1
Ta del CISPR 16-4 določa metodo za uporabo negotovosti merilnih instrumentov (MIU) pri določanju skladnosti z mejami motenj po CISPR. Gradivo je pomembno tudi za vse preskuse EMC, pri katerih na razlago rezultatov in zaključke vpliva negotovost merilnih instrumentov, uporabljenih med preskušanjem.
OPOMBA: V skladu z Vodilom IEC 107 je CISPR 16-4-2 osnovni standard EMC, ki ga uporabljajo odbori za proizvode IEC. Kot je navedeno v Vodilu 107, so odbori za proizvode odgovorni za določevanje uporabe tega standarda EMC. CISPR in njegovi pododbori so pripravljeni sodelovati s tehničnimi odbori in odbori za proizvode pri ocenjevanju uporabnosti tega standarda za določene proizvode. Dodatki vsebujejo temeljno gradivo, ki se uporablja pri podajanju velikosti MIU, ugotovljene pri nastajanju vrednosti CISPR, prikazanih v točkah od 4 do 8, in so zato koristno temeljno gradivo za tiste, ki potrebujejo začetne in nadaljnje informacije o MIU in informacije o tem, kako v verigi meritev upoštevati posamezne negotovosti. Dodatki niso mišljeni kot priročniki za vajo ali uporabo ali za kopiranje pri izračunavanju negotovosti. V ta namen se lahko uporabljajo reference, navedene v bibliografiji, ali drugi splošno priznani dokumenti.
Specifikacije merilnih instrumentov so podane v seriji CISPR 16-1, merilne metode pa zajema serija CISPR 16-2. Nadaljnje informacije in ozadje o CISPR in radijskih motnjah so navedeni v CISPR 16-3. Drugi deli serije CISPR 16-4 vsebujejo več informacij o negotovosti na splošno, statistiki in modeliranju mejnih vrednosti. Za več informacij o ozadju in o vsebini serije CISPR 16-4 glejte uvod tega dela.
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 55016-4-2:2011/A1:2014
01-oktober-2014
Specifikacija za merilne naprave in metode za merjenje radijskih motenj in
odpornosti - 4-2. del: Modeliranje negotovosti, statistike in mejnih vrednosti -
Negotovost merilnih instrumentov - Dopolnilo A1
Specification for radio disturbance and immunity measuring apparatus and methods --
Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation
uncertainty
Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur
Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Teil
4-2: Unsicherheiten, Statistik und Modelle zur Ableitung von Grenzwerten (Störmodell) -
Messgeräte-Unsicherheit
Spécifications des méthodes et des appareils de mesure des perturbations
radioélectriques et de l'immunité aux perturbations radioélectriques -- Partie 4-2:
Incertitudes, statistiques et modélisation des limites - Incertitudes de mesure de
l'instrumentation
Ta slovenski standard je istoveten z: EN 55016-4-2:2011/A1:2014
ICS:
17.220.20 0HUMHQMHHOHNWULþQLKLQ Measurement of electrical
PDJQHWQLKYHOLþLQ and magnetic quantities
33.100.01 Elektromagnetna združljivost Electromagnetic compatibility
na splošno in general
SIST EN 55016-4-2:2011/A1:2014 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 55016-4-2:2011/A1:2014
EUROPEAN STANDARD EN 55016-4-2:2011/A1
NORME EUROPÉENNE
EUROPÄISCHE NORM
July 2014
ICS 33.100.10; 33.100.20
English Version
Specification for radio disturbance and immunity measuring
apparatus and methods - Part 4-2: Uncertainties, statistics and
limit modelling - Measurement instrumentation uncertainty
(CISPR 16-4-2:2011/A1:2014)
Spécifications des méthodes et des appareils de mesure Anforderungen an Geräte und Einrichtungen sowie
des perturbations radioélectriques et de l'immunité aux Festlegung der Verfahren zur Messung der hochfrequenten
perturbations radioélectriques - Partie 4-2: Incertitudes, Störaussendung (Funkstörungen) und Störfestigkeit -
statistiques et modélisation des limites - Incertitudes de Teil 4-2: Unsicherheiten, Statistik und Modelle zur Ableitung
mesure de l'instrumentation von Grenzwerten (Störmodell) - Messgeräte-Unsicherheit
(CISPR 16-4-2:2011/A1:2014) (CISPR 16-4-2:2011/A1:2014)
This amendment A1 modifies the European Standard EN 55016-4-2:2011; it was approved by CENELEC on 2014-03-21. CENELEC
members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this amendment the
status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language made by translation under the
responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as
the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2014 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 55016-4-2:2011/A1:2014 E
---------------------- Page: 2 ----------------------
SIST EN 55016-4-2:2011/A1:2014
EN 55016-4-2:2011/A1:2014 - 2 -
Foreword
The text of document CISPR/A/1049/FDIS, future CISPR 16-4-2:2011/A1, prepared by CISPR SC A
“Radio-interference measurements and statistical methods” of CISPR “International special committee
on radio interference” was submitted to the IEC-CENELEC parallel vote and approved by CENELEC
as EN 55016-4-2:2011/A1:2014.
The following dates are fixed:
– latest date by which the document has to be implemented at (dop) 2014-11-01
national level by publication of an identical national
standard or by endorsement
– latest date by which the national standards conflicting with (dow) 2017-03-21
the document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
Endorsement notice
The text of the International Standard CISPR 16-4-2:2011/A1:2014 was approved by CENELEC as a
European Standard without any modification.
---------------------- Page: 3 ----------------------
SIST EN 55016-4-2:2011/A1:2014
CISPR 16-4-2
®
Edition 2.0 2014-02
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
INTERNATIONAL SPECIAL COMMITTEE ON RADIO INTERFERENCE
COMITÉ INTERNATIONAL SPÉCIAL DES PERTURBATIONS RADIOÉLECTRIQUES
BASIC EMC PUBLICATION
PUBLICATION FONDAMENTALE EN CEM
AMENDMENT 1
AMENDEMENT 1
Specification for radio disturbance and immunity measuring apparatus and
methods –
Part 4-2: Uncertainties, statistics and limit modelling – Measurement
instrumentation uncertainty
Spécifications des méthodes et des appareils de mesure des perturbations
radioélectriques et de l'immunité aux perturbations radioélectriques –
Partie 4-2: Incertitudes, statistiques et modélisation des limites – Incertitudes de
mesure de l’instrumentation
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX E
ICS 33.100.10; 33.100.20 ISBN 978-2-8322-1382-7
Warning! Make sure that you obtained this publication from an authorized distributor.
Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.
® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale
---------------------- Page: 4 ----------------------
SIST EN 55016-4-2:2011/A1:2014
– 2 – CISPR 16-4-2 Amend.1 IEC:2014
FOREWORD
This amendment has been prepared by subcommittee A of CISPR: Radio-interference
measurements and statistical methods.
The text of this amendment is based on the following documents:
FDIS Report on voting
CISPR/A/1049/FDIS CISPR/A/1058/RVD
Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of this amendment and the base publication will
remain unchanged until the stability date indicated on the IEC web site under
"http://webstore.iec.ch" in the data related to the specific publication. At this date, the
publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.