IEC 60092-379:2024 is applicable to shipboard and offshore units Ethernet (category) cables with extruded solid or foamed insulation, intended for fixed installations. Cables designed to maintain functional integrity during fire as specified in 6.1 and to be installed in explosive atmospheres as specified in 6.2 are included. The various types of Ethernet (category) cables are given in Clause 4. The constructional requirements and test methods are aligned with those indicated in IEC 60092-350, unless otherwise specified in this document.

  • Standard
    19 pages
    English language
    sale 15% off

IEC 60092-353:2024 is applicable to shipboard and offshore non radial field power cables with extruded solid insulation, having a voltage rating of 0,6/1 (1,2) kV or 1,8/3 (3,6) kV intended for fixed installations. Cables designed to maintain circuit integrity during a fire are included. The various types of power cables are given in 5.1. The constructional requirements and test methods are aligned with those indicated in IEC 60092-350, unless otherwise specified in this document.
The object of this document is:
- to standardize cables whose safety and reliability is ensured when they are installed in accordance with the requirements of IEC 60092-352 or IEC 61892-4,
- to lay down standard manufacturing requirements and characteristics of such cables directly or indirectly bearing on safety, and
- to specify test methods for checking conformity with those requirements.
This fifth edition cancels and replaces the fourth edition published in 2016. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) Updated references to IEC 60092-350 for general construction and test methods and IEC 60092-360 for insulating and sheathing materials.
b) Added subclause 5.10: Construction for special applications.
c) Added Table 9: Additional test for cables for installation between areas with and without explosive atmospheres.
d) Deleted the test requirement IEC 60331-21 from Table 7.
e) Deleted the former Annex A (Alternative enhanced insulation thickness for 0,6/1 kV).

  • Standard
    21 pages
    English language
    sale 15% off
  • Standard
    43 pages
    English language
    sale 15% off

IEC 60092:2021 specifies the requirements for electrical, mechanical and particular characteristics of insulating and sheathing materials intended for use in shipboard and fixed and mobile offshore unit power, control, instrumentation and telecommunication cables.

  • Standard
    26 pages
    English language
    sale 15% off
  • Standard
    52 pages
    English language
    sale 15% off

IEC 60092-354:2020 is applicable to shipboard and offshore power cables with extruded solid insulation, conductor and core screening, having a voltage rating of one of the following: 3,6/6 (7,2) kV,6/10 (12) kV, 8,7/15 (17,5) kV, 12/20 (24) kV, 18/30 (36) kV. The cables are intended for fixed installations. The various types of power cables are given in 5.1. The constructional requirements and test methods are aligned with those indicated in IEC 60092-350, unless otherwise specified in this document.
The object of this document is:
- to standardize cables whose safety and reliability is ensured when they are installed in accordance with the requirements of IEC 60092-352 or IEC 61892-4;
- to lay down standard manufacturing requirements and characteristics of such cables directly or indirectly bearing on safety;
- to specify test methods for checking conformity with those requirements.
Only radial field cables are covered. This fourth edition cancels and replaces the third edition published in 2014. This edition constitutes a technical revision.

  • Standard
    54 pages
    English language
    sale 15% off
  • Standard
    36 pages
    English and French language
    sale 15% off

IEC 60092-350:2020 provides the general constructional requirements and test methods for use in the manufacture of electric power, control and instrumentation cables with copper conductors intended for fixed electrical systems at voltages up to and including 18/30(36) kV on board ships and offshore (mobile and fixed) units.
The reference to fixed systems includes those that are subjected to vibration (due to the movement of the ship or installation) or movement (due to motion of the ship or installation) and not to those that are intended for frequent flexing. Cables suitable for frequent or continual flexing use are detailed in other IEC standards, for example IEC 60227 (all parts) and IEC 60245 (all parts), and their uses are restricted to those situations which do not directly involve exposure to a marine environment, for example, portable tools and domestic appliances.
The following types of cables are not included:
- optical fibre;
- sub-sea and umbilical cables;
- data and communication cables;
- coaxial cables.
This fifth edition cancels and replaces the fourth edition published in 2014 and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) more detailed description of the test procedures in 7.7.6 and 7.7.7;
b) description of the relationship between Annex A and Annex D.

  • Standard
    52 pages
    English language
    sale 15% off
  • Standard
    106 pages
    English language
    sale 15% off
  • Standard
    107 pages
    English and French language
    sale 15% off

IEC TR 60092-370:2019 gives guidance and lays down the basic recommendations for the selection and installation of shipboard and offshore unit cables intended for electrical systems used in both essential and non-essential analogue or digital signal communication, transmission and control networks, including types suitable for high-frequency signals (i.e. signals with a frequency of more than 105 Hz). These cables are not suitable for direct connection to low impedance supplies. Where such cables are required, attention is drawn to IEC 60092-353. Cables intended to have limited circuit integrity (fire resistance) when affected by fire are not covered by this document. Fibre optical cables are not included. Sub-sea or umbilical cables are not included. This second edition cancels and replaces the first edition published in 2009. This edition constitutes a technical revision. This edition includes the following significant technical change with respect to the previous edition: 30 V AC was added in voltage rating for data cables.

  • Technical report
    18 pages
    English language
    sale 15% off
  • Technical report
    36 pages
    English language
    sale 15% off

IEC 60092-376:2017 is applicable to screened and unscreened cables for control and instrumentation circuits on ships and offshore units. The cables have extruded solid insulation with a voltage rating of 150/250V (300V) and are intended for fixed installations.
The various types of cables are given in Clause 5. The constructional requirements and test methods are aligned with those indicated in IEC 60092-350, unless otherwise specified in this document.
The object of this document is:
- to standardise cables whose safety and reliability are ensured when they are installed in accordance with the requirements of IEC 60092-352,
- to lay down standard manufacturing requirements and characteristics of such cables directly or indirectly bearing on safety, and
- to specify test methods for checking conformity with those requirements.
This edition includes the following significant technical changes with respect to the previous edition:
- new structure in line with IEC 60092-353 and IEC 60092-354;
- requirements and test methods have been divided in several tables for clarification (enhanced cold properties, oil resistance or resistance to drilling fluids) and have been aligned to IEC 60092-350;
- the new testing methods for fire resistant cables are referenced in this document.

  • Standard
    24 pages
    English language
    sale 15% off
  • Standard
    54 pages
    English language
    sale 15% off

IEC 60092-353:2016 is applicable to shipboard and offshore non radial field power cables with extruded solid insulation, having a voltage rating of 0,6/1 (1,2) kV or 1,8/3 (3,6) kV intended for fixed installations. Cables designed to maintain circuit integrity during fire are included. The various types of power cables are given in 5.1. The constructional requirements and test methods are aligned with those indicated in IEC 60092-350, unless otherwise specified in this document. The object of this document is:
- to standardize cables whose safety and reliability is ensured when they are installed in accordance with the requirements of IEC 60092-352 or IEC 61892-4,
- to lay down standard manufacturing requirements and characteristics of such cables directly or indirectly bearing on safety, and
- to specify test methods for checking conformity with those requirements. This edition includes the following significant technical changes with respect to the previous edition:
- updated references to IEC 60092-350 for general construction and test methods and IEC 60092-360 for insulating and sheathing materials.

  • Standard
    64 pages
    English language
    sale 15% off
  • Standard
    41 pages
    English and French language
    sale 15% off

IEC 60092-354:2014 is applicable to shipboard and offshore power cables with extruded solid insulation, conductor and core screening, having a voltage rating of one of the following:
3,6/6 (7,2) kV, 6/10 (12) kV, 8,7/15 (17,5) kV, 12/20 (24) kV, 18/30 (36) kV. The cables are intended for fixed installations. The object of this standard is:
- to standardize cables whose safety and reliability are ensured when they are installed in accordance with the requirements of IEC 60092-352 or IEC 61892-4;
- to lay down standard manufacturing requirements and characteristics of such cables directly or indirectly bearing on safety;
- to specify test methods for checking conformity with those requirements.
This edition includes the following significant technical changes with respect to the previous edition:
a) Modification of construction requirements in line with IEC 60092-350. There has been some redistribution of test methods between IEC 60092-350 and this new standard to remove all tests carried out on complete cables.
b) Requirements for enhanced cold properties, oil resistance and resistance to drilling fluids have been aligned to IEC 60092-350.

  • Standard
    33 pages
    English and French language
    sale 15% off

IEC 60092-350:2014 provides the general constructional requirements and test methods for use in the manufacture of electric power, control and instrumentation cables with copper conductors intended for fixed electrical systems at voltages up to and including 18/30(36) kV on board ships and offshore (mobile and fixed) units. The following types of cables are not included:
- optical fibre;
- sub-sea and umbilical cables;
- data and communication cables;
- coaxial cables. This edition includes the following significant technical changes with respect to the previous edition:
a) reference to IEC 60092-360 for both the insulating and sheathing compounds;
b) partial discharge tests have been transferred from IEC 60092-354 to align it with IEC 60092-353;
c) requirements for oil and drilling-fluid resistance (former Annexes F and G) have been transferred to IEC 60092-360;
d) requirements for cold bending and shocks have been improved;
e) the document reflects the changes of material types that have been introduced during the development of IEC 60092-353 and IEC 60092-360.
The contents of the corrigendum of November 2018 have been included in this copy.

  • Standard
    110 pages
    English and French language
    sale 15% off

IEC 60092-360:2014 specifies the requirements for electrical, mechanical and particular characteristics of insulating and sheathing materials intended for use in shipboard and fixed and mobile offshore unit power, control, instrumentation and telecommunication cables. This first edition cancels and replaces IEC 60092-351 Ed. 3 published in 2004 and IEC 60092-359 Ed. 1 published in 1987, Amendment 1:1994 and Amendment 2:1992. This edition constitutes a technical revision.

  • Standard
    50 pages
    English and French language
    sale 15% off

IEC 60092-353:2011 is applicable to shipboard and offshore non radial field power cables with extruded solid insulation, having a voltage rating of 0,6/1 (1,2) kV and 1,8/3 (3,6) kV intended for fixed installations. Cables for use in circuits requiring resistance to fire are included. The various types of power cables are given in 5.1. The constructional requirements and test methods shall comply with those indicated in IEC 60092-350, unless otherwise specified in this standard. The object of this standard is:
- to standardize cables whose safety and reliability is ensured when they are installed in accordance with the requirements of IEC 60092-352 or IEC 61892-4;
- to lay down standard manufacturing requirements and characteristics of such cables directly or indirectly bearing on safety;
- to specify test methods for checking conformity with those requirements.
This edition includes the following significant technical changes with respect to the previous edition:
a) Rationalization of the number of insulating and sheathing materials. In particular polyvinyl chloride based insulation (PVC) and sheath (ST1) have been removed. PVC sheath ST2 is permitted even though it releases harmful fumes under fire conditions;
b) Modification of construction requirements in line with IEC 60092-350;
c) Requirements and test methods have been divided in several tables for clarification. Requirements for enhanced cold properties, oil resistance and resistance to drilling fluids have been aligned to IEC 60092-350;
d) The new testing methods for fire resistant cables are referenced in the standard.

  • Standard
    41 pages
    English and French language
    sale 15% off

IEC/TR 60092-370:2009(E) Technical Report gives guidance and lays down the basic recommendations for the selection and installation of shipboard and offshore unit cables intended for electrical systems used in both essential and non-essential analogue or digital signal communication, transmission and control networks, including types suitable for high-frequency signals (i.e. signals with a frequency of more than 105 Hz). These cables are not suitable for direct connection to low impedance supplies. Where such cables are required, attention is drawn to IEC 60092-353.

  • Technical report
    18 pages
    English language
    sale 15% off

This part of IEC 60092 provides the general constructional requirements and test methods for use in the manufacture of electric power, control and instrumentation cables with copper conductors intended for fixed electrical systems at voltages up to and including 18/30(36) kV on board ships and offshore (mobile and fixed) units. This third edition cancels and replaces the second edition published in 2001 and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) the new insulating compounds contained in IEC 60092-351;
b) the new sheathing compounds contained in IEC 60092-359;
c) the publication of IEC 60092-376;
d) the inclusion of cables up to 30 kV in the revision of IEC 60092-354;
e) for use in a limited number of closely defined applications, the provision to allow the design of a single core cable with a single extrusion covering, having a thickness equal to that of both an insulation and sheath;
f) new tests for the determination of enhanced cold properties, oil resistance, and resistance to drilling fluids.

  • Standard
    52 pages
    English language
    sale 15% off

This standard provides the basic requirements for the choice and installation of cables intended for fixed electrical systems on board ships at voltages (U) up to and including 15 kV. The reference to fixed systems includes those that are subjected to vibration (due to the movement of the ship) or movement (due to motion of the ship) and not to those that are intended for frequent flexing. Cables suitable for frequent or continual flexing use are detailed in other IEC specifications e.g. IEC 60227 and IEC 60245, and their uses on board ship is restricted to those situations which do not directly involve exposure to a marine environment e.g. portable tools or domestic appliances.

  • Standard
    49 pages
    English language
    sale 15% off

This part of IEC 60092 is applicable to shipboard and offshore power cables with extruded solid insulation, conductor and core screening, having a voltage rating of 3,6/6 (7,2) kV, 6/10 (12) kV, 8,7/15 (17,5) kV, 12/20 (24) kV, 18/30 (36) kV (see Clause 4) and intended for fixed installations. The voltage rating for shipboard use is limited to 8,7/15(17,5) kV.

  • Standard
    18 pages
    English language
    sale 15% off

This part of IEC 60092 is applicable to screened and unscreened cables for control and instrumentation circuits on ships and offshore units. The cables have extruded solid insulation with a voltage rating of 150/250V (300V) and are intended for fixed installations.

  • Standard
    21 pages
    English language
    sale 15% off

This part of IEC 60092 specifies the general constructional requirements and general test recommendations for shipboard cables with copper conductors intended for power systems at voltages up to and including 8,7/15 kV.

  • Standard
    44 pages
    English language
    sale 15% off

Specifies test requirements for electrical, mechanical and other characteristics of insulating materials intended for shipboard power cables.

  • Standard
    31 pages
    English and French language
    sale 15% off

Gives the dimensions for pin connectors and socket connectors for cables 96 IEC 60050-17 and larger.[
]The contents of the corrigendum of February 1971 have been included in this copy.

  • Standard
    3 pages
    English and French language
    sale 15% off

Gives basic requirements for the choice and installation of cables for voltages up to and including 1 000 V. Cancel and replaces chapter XI of IEC 60092-3.

  • Standard
    55 pages
    English and French language
    sale 15% off

The content of this Report is intended as supplementary specifications for fire type testing of cable transit which shall comply with the Regulations of the 1981 SOLAS Amendments Chapter II-2.

  • Technical report
    19 pages
    English and French language
    sale 15% off

This part of IEC 60092 specifies the requirements for electrical, mechanical and particular characteristics of insulating materials intended for use in shipboard and fixed and mobile offshore unit power, control, instrumentation, telecommunication and data cables.

  • Standard
    16 pages
    English language
    sale 15% off

Cancels and replaces IEC 60092-3 except chapter X Specifes the test requirements for mechanical and particular characteristics of sheathing materials intended to be used in shipboard power and telecommunication cables.

  • Standard
    1 page
    English and French language
    sale 15% off
  • Standard
    17 pages
    English and French language
    sale 15% off

This standard concerns r.f. coaxial connectors for use with r.f. cables, both flexible and semi-rigid, with air dielectric interface and high mechanical stability to withstand severe environmental exposure. The connectors provide low reflection in the microwave region up to 14 GHz and they are watertight and air-tight against a pressure difference of 3 bar.

  • Standard
    5 pages
    English and French language
    sale 15% off