IEC 60800:2021 is available as IEC 60800:2021 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60800:2021 is applicable to, and specifies requirements for resistive heating cables for low temperature applications such as comfort heating and the prevention of ice formation. These heating cables and heating cable sets can comprise either factory assembled or field (work-site) assembled units, and are heating cables assembled in accordance with manufacturer’s instructions. Bare conductors and protected conductors to be supplied at voltages equal to, or less than, 50 V are excluded from the scope of this document.
Typical applications include, but are not limited to:
- surface heating installed in or under surfaces;
- direct and storage heating;
- snow melting and frost protection of roofs, gutters, pipes, etc.
Electrical resistance trace heating systems for industrial and commercial applications are specified in the IEC 62395 series [1] and for explosive atmospheres applications in the IEC/IEEE 60079-30 series [2], as are mineral insulated heating cables. Applications in which the sheath temperature exceeds 100 °C are outside the scope of this document.

  • Standard
    61 pages
    English and French language
    sale 15% off

IEC 63294:2021 specifies the test methods for electric cables with rated voltages up to and including 450/750 V not included in the IEC 60811 series.

  • Standard
    58 pages
    English and French language
    sale 15% off

IEC TS 62893-4-2:2021(E) applies to cables for DC charging according to mode 4 of IEC 61851-1. These cables are intended to be used with a thermal management system such as that specified in IEC 61851-23.
Charging cables specified in IEC 62893 (all parts) are intended to be used for electrical appliances of class II equipment.
Maximum conductor operating temperature for the cables in this document is 90 ºC.
The test methods specified are given in IEC 62893-2, IEC 60227-2, IEC 60245-2, IEC 60332 1 2, IEC 62821-1:2015, Annex B and in the relevant parts of IEC 60811.
IEC 62440 is intended to be used as guidance on the safe use of cables in this document together with specific guidance in Clause 6 of this document.

  • Technical specification
    23 pages
    English language
    sale 15% off

IEC 62893-4-1:2020 applies to cables for DC charging according to mode 4 of IEC 61851-1. These cables are not intended to be used with a thermal management system such as that specified in IEC 61851-23.
Charging cables specified in IEC 62893 (all parts) are intended to be used for electrical appliances of class II equipment.
The maximum conductor operating temperature for the cables in this document is 90 °C.
The test methods specified are given in IEC 62893-2, IEC 60245-2, IEC 60332-1-2, IEC 62821‑1:2015, Annex B and in the relevant parts of IEC 60811.
IEC 62440 is intended to be used as guidance on the safe use of cables in this document together with Clause 5 of this document.
This document is to be read in conjunction with IEC 62893-1:2017 and IEC 62893-2:2017.

  • Standard
    18 pages
    English language
    sale 15% off

IEC 62930:2017(E) applies to single-core cross-linked insulated power cables with cross-linked sheath. These cables are for use at the direct current (DC) side of photovoltaic systems, with a rated DC voltage up to and including 1,5 kV between conductors and between conductor and earth. This document includes halogen free low smoke cables and cables that can contain halogens.
The cables are suitable to be used with Class II equipment as defined in IEC 61140.
The cables are designed to operate at a normal continuous maximum conductor temperature of 90 °C. The permissible period of use at a maximum conductor temperature of 120 °C is limited to 20 000 h.

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    27 pages
    English language
    sale 15% off

IEC 62893-2:2017(E) specifies test methods which are particular for cables with extruded insulation and sheath having a voltage rating of up to and including 0,6/1 kV AC or up to and including 1 500 V DC for flexible applications under harsh conditions for the power supply between the electricity supply point or the charging station and the electric vehicle (EV).

  • Standard
    14 pages
    English language
    sale 15% off

IEC 62893-1:2017(E) specifies construction, dimensions and test requirements for cables with extruded insulation and sheath having a voltage rating of up to and including 0,6/1 kV AC or up to and including 1 500 V DC for flexible applications under harsh conditions for the power supply between the electricity supply point of the charging station and the electric vehicle (EV).
The EV charging cable is intended to supply power and, if needed, communication (for details see the IEC 62196 series and IEC 61851-1) to an EV or plug-in hybrid vehicle (PHEV). The charging cables are applicable for charging modes 1 to 4 of IEC 61851-1. Ordinary duty cables with rated voltage 300/500 V are only permitted for charging mode 1 of IEC 61851-1. Maximum conductor temperature for the cables in this part of IEC 62893 is 90 ºC.
The particular types of cables are specified in IEC 62893-3 (modes 1 to 3 for AC charging) and in the future IEC 62893-4 (mode 4 for DC charging).
These parts are collectively referred to hereafter as “the particular specifications”.
The test methods specified are given in IEC 62893-2, IEC 60245-2, IEC 60332-1-2, IEC 62821-1:2015, Annex B, and in the relevant parts of IEC 60811, as listed in the normative references.

  • Standard
    48 pages
    English language
    sale 15% off
  • Standard
    23 pages
    English language
    sale 15% off

IEC 62893-3:2017(E) applies to cables for AC charging according to modes 1, 2 and 3 of IEC 61851-1. The cables are of rated voltages U0/U up to and including 450/750 V. Ordinary duty cables with rated voltage 300/500 V are only permitted for charging mode 1 of IEC 61851-1.
Maximum conductor operating temperature for the cables in this document is 90 ºC.

  • Standard
    15 pages
    English language
    sale 15% off

IEC 63010-1:2017(E) applies to cables with insulation and sheaths based on halogen-free thermoplastic compounds for use with small devices and for short connections to desktop electrical appliances where flexibility is of prime importance. These cables have a voltage rating U0/U up to and including 300/300 V. Maximum operating temperature for the cables in this document is 70°C.

  • Standard
    23 pages
    English language
    sale 15% off

IEC 60811-410:2012 gives the procedure for copper-catalyzed oxidative degradation of a polyolefin, which is typically used for insulation in communication cables. IEC 60811-410:2012 cancels and replaces Annex B of IEC 60811-4-2:2004, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There are no specific technical changes with respect to the previous edition, but see the Foreword to IEC 60811-100:2012.
This publication is to be read in conjunction with IEC 60811-100:2012.

  • Standard
    43 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    21 pages
    English and French language
    sale 15% off

IEC 60811-509:2012 gives the procedure for the test for resistance of insulations and sheaths to cracking at an elevated temperature. IEC 60811-509:2012 cancels and replaces Clause 9 of IEC 60811-3-1:1985, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There are no specific technical changes with respect to the previous edition, but see the Foreword to IEC 60811-100:2012.
This publication is to be read in conjunction with IEC 60811-100:2012.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    21 pages
    English and French language
    sale 15% off

IEC 60811-201:2012 gives the methods for measuring the insulation thicknesses which apply to the most common types of insulating compounds (cross-linked, PVC, PE, PP, etc.). IEC 60811-201:2012 cancels and replaces 8.1 of IEC 60811-1-1:1993, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There are no technical changes with respect to the previous edition, but see the Foreword to IEC 60811-100:2012.
This publication is to be read in conjunction with IEC 60811-100:2012.

  • Standard
    21 pages
    English and French language
    sale 15% off

IEC 60702-3:2016 provides guidance for the safe use of mineral insulated cables and their terminations with a rated voltage not exceeding 750 V which are specified in IEC 60702-1 and IEC 60702-2.

  • Standard
    25 pages
    English and French language
    sale 15% off

IEC 62821-1:2015 applies to cables with insulation, and sheath if any, based on halogen-free, thermoplastic compound, and having low emission of smoke and corrosive gases when exposed to fire, of rated voltages up to and including 450/750 V used in power installations of nominal voltage not exceeding 450/750 V a.c.

  • Standard
    47 pages
    English and French language
    sale 15% off

IEC 62821-3:2015 applies to flexible cables for connection to appliances, insulated and sheathed with halogen-free thermoplastic compound and having low emission of smoke and corrosive gases when exposed to fire. The cables are of rated voltages up to and including 300/500 V. Circular cables and flat cables are included.
This publication is to be read in conjunction with IEC 62821-1:2015.

  • Standard
    28 pages
    English and French language
    sale 15% off

Specifies requirements for terminations for use with mineral insulated cables complying with the requirements of IEC 60702-1.

  • Standard
    17 pages
    English and French language
    sale 15% off
  • Standard
    10 pages
    English and French language
    sale 15% off

IEC 60811-606:2012 descries the methods for determining the density for the most common types of insulating and sheathing compounds (cross-linked, PVC, PE, PP, etc.). IEC 60811-606:2012 cancels and replaces Clause 8 of IEC 60811-1-3:1993, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There are no specific technical changes with respect to the previous edition, but see the Foreword to IEC 60811-100:2012.
This publication is to be read in conjunction with IEC 60811-100:2012.

  • Standard
    20 pages
    English and French language
    sale 15% off

IEC 60811-504:2012 gives the procedure for performing bending tests at low temperature on extruded insulations and sheaths. IEC 60811-504:2012 cancels and replaces 8.1 and 8.2 of IEC 60811-1-4:1985, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There are no specific technical changes with respect to the previous edition, but see the Foreword to IEC 60811-100: 2012.
This publication is to be read in conjunction with IEC 60811-100:2012.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    20 pages
    English and French language
    sale 15% off

IEC 60811-607:2012 specifies test methods for carbon black dispersion that are applicable specifically to PE and PP compounds, including cellular compounds and foam skin for insulation. IEC 60811-607:2012 cancels and replaces Clause 13 of IEC 60811-4-1:2004, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There are no specific technical changes with respect to the previous edition, but see the Foreword to IEC 60811-100:2012.
This publication is to be read in conjunction with IEC 60811-100:2012.

  • Standard
    16 pages
    English and French language
    sale 15% off

IEC 60811-508:2012 gives the procedure for a pressure test at high temperature, which typically applies to thermoplastic compounds used for insulating and sheathing materials. IEC 60811-508:2012 cancels and replaces Clause 8 of IEC 60811-3-1:1985, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. Significant technical changes with respect to the previous edition are as follows:
- re-statement of oven characteristics, especially relating to anti-vibration and to temperature control;
- enhanced detail as to the preparations and testing of flat cables;
- enhanced detail as to thickness and dimensional measurements. See also the Foreword to IEC 60811-100:2012.
This publication is to be read in conjunction with IEC 60811-100:2012.

  • Standard
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    36 pages
    English and French language
    sale 15% off

IEC 60811-605:2012 describes the test methods for measuring the content of carbon black added for UV stabilization of polyethylene and polyolefin compounds. These methods are not suitable for halogenated compounds. Method A is suitable only for polyethylene and polypropylene compounds. Method B is suitable for polyolefine compounds. IEC 60811-605:2012 cancels and replaces Clauses 11 and 12 of IEC 60811-4-1:2004, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There are no specific technical changes with respect to the previous edition, but see the foreword to IEC 60811-100:2012.
This publication is to be read in conjunction with IEC 60811-100:2012.

  • Standard
    18 pages
    English and French language
    sale 15% off

IEC 60811-602:2012 gives the test methods for separation of oil in filling compounds. IEC 60811-602:2012 cancels and replaces Clause 5 of IEC 60811-5-1:1990, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There are no specific technical changes with respect to the previous edition, but see the Foreword to IEC 60811-100:2012.
This publication is to be read in conjunction with IEC 60811-100:2012.

  • Standard
    18 pages
    English and French language
    sale 15% off

IEC 60811-507:2012 gives the procedure for the hot set test, which typically applies to cross-linkable compounds used for insulating and sheathing materials. IEC 60811-507:2012 cancels and replaces Clause 9 of IEC 60811-2-1:1998, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There are no specific technical changes with respect to the previous edition, but see the Foreword to IEC 60811-100:2012.
This publication is to be read in conjunction with IEC 60811-100:2012.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    20 pages
    English and French language
    sale 15% off

IEC 60811-604:2012 indicates the effect of the filling compound when in contact with the metallic parts of the cable. IEC 60811-604:2012 cancels and replaces Clause 8 of IEC 60811-5-1:1990, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There are no specific technical changes with respect to the previous edition, but see the Foreword to IEC 60811-100:2012.
This publication is to be read in conjunction with IEC 60811-100:2012.

  • Standard
    16 pages
    English and French language
    sale 15% off

IEC 60811-506:2012 gives the procedure for performing impact tests at low temperature on extruded insulations and sheaths. IEC 60811-506:2012 cancels and replaces 8.5 of IEC 60811-1-4:1985, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There are no specific technical changes with respect to the previous edition, but see the Foreword to IEC 60811-100:2012.
This publication is to be read in conjunction with IEC 60811-100:2012.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    20 pages
    English and French language
    sale 15% off

IEC 60811-513:2012 gives procedures for a wrapping test after conditioning at elevated temperature. This test method applies specifically to polyethylene and polypropylene insulation. This test is intended for samples from filled cables of polyolefin insulation having a wall thickness of less than or equal to 0,8 mm. IEC 60811-513:2012 cancels and replaces Clause 9 of IEC 60811-4-2:2004, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There are no specific technical changes with respect to the previous edition, but see the Foreword to IEC 60811-100:2012.
This publication is to be read in conjunction with IEC 60811-100:2012.

  • Standard
    16 pages
    English and French language
    sale 15% off

IEC 60811-505:2012 gives the procedure for performing elongation tests at low temperature on extruded insulations and sheaths. IEC 60811-505:2012 cancels and replaces 8.3 and 8.4 of IEC 60811-1-4:1985, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There are no specific technical changes with respect to the previous edition, but see the Foreword to IEC 60811-100:2012.
This publication is to be read in conjunction with IEC 60811-100:2012.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    21 pages
    English and French language
    sale 15% off

IEC 60811-503:2012 gives the test method for the shrinkage for sheaths. IEC 60811-503:2012 cancels and replaces Clause 11 of IEC 60811-1-3:1993, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There are no specific technical changes with respect to the previous edition, but see the Foreword to IEC 60811-100:2012.
This publication is to be read in conjunction with IEC 60811-100:2012.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    16 pages
    English and French language
    sale 15% off

IEC 60811-511:2012 describes the procedure for the measurement of the melt flow index for polyethylene compounds. IEC 60811-511:2012 cancels and replaces Clause 10 of IEC 60811-4-1:2004, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There are no specific technical changes with respect to the previous edition, but see the Foreword to IEC 60811-100:2012.
This publication is to be read in conjunction with IEC 60811-100:2012.

  • Standard
    24 pages
    English and French language
    sale 15% off

IEC 60811-502:2012 gives the test method for the shrinkage for insulations. IEC 60811-502:2012 cancels and replaces Clause 10 of IEC 60811-1-3:1993, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There are no specific technical changes with respect to the previous edition, but see the Foreword to IEC 60811-100:2012.
This publication is to be read in conjunction with IEC 60811-100:2012.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    16 pages
    English and French language
    sale 15% off

IEC 60811-501:2012 gives the procedure for determining the mechanical properties, which typically applies to cross-linked and thermoplastic compounds used for insulating and sheathing materials. IEC 60811-501:2012 cancels and replaces Clause 9 of IEC 60811-1-1:1993, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There is one significant technical change with respect to the previous edition: the requirements for the (minimum) thickness of dumb-bell test pieces have changed. See also the Foreword to IEC 60811-100.
This publication is to be read in conjunction with IEC 60811-100:2012.

  • Standard
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    33 pages
    English and French language
    sale 15% off

IEC 60811-601:2012 specifies the test procedure for measuring the drop point of filling compounds. IEC 60811-601:2012 cancels and replaces Clause 4 of IEC 60811-5-1:1990, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There are no specific technical changes with respect to the previous edition, but see the foreword to IEC 60811-100:2012.
This publication is to be read in conjunction with IEC 60811-100:2012.

  • Standard
    25 pages
    English and French language
    sale 15% off

IEC 60811-512:2012 describes the procedure for testing tensile strength and elongation at break after conditioning at elevated temperature. It is specific to polyethylene and polypropylene compounds. This test is intended for samples from filled cables, of polyolefin insulations with a wall thickness of more than 0,8 mm and for polyolefin sheaths in direct contact with filling compound. IEC 60811-512:2012 cancels and replaces Clause 8 of IEC 60811-4-2:2004, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There are no specific technical changes with respect to the previous edition, but see the Foreword to IEC 60811-100:2012.
This publication is to be read in conjunction with IEC 60811-100:2012.

  • Standard
    16 pages
    English and French language
    sale 15% off

IEC 60811-603:2012 gives the test methods to examine the filling compound for corrosive elements. IEC 60811-603:2012 cancels and replaces Clause 7 of IEC 60811-5-1:1990, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There are no specific technical changes with respect to the previous edition, but see the Foreword to IEC 60811-100:2012.
This publication is to be read in conjunction with IEC 60811-100:2012.

  • Standard
    20 pages
    English and French language
    sale 15% off

IEC 60811-510:2012 specifies the test method for a wrapping test after thermal ageing in air. This test method applies specifically to polyolefin insulation in communication cables. This test is intended for polyolefin insulations of unfilled cables and of dry cores for filled cables, where the insulation has a wall thickness of less than or equal to 0,8 mm. IEC 60811-510:2012 cancels and replaces Clause 10 of IEC 60811-4-2:2004, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There are no specific technical changes with respect to the previous edition, but see the Foreword to IEC 60811-100:2012.
This publication is to be read in conjunction with IEC 60811-100:2012.

  • Standard
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    16 pages
    English and French language
    sale 15% off

IEC 60811-302:2012 gives the procedure to examine the d.c. resistivity at 23 °C and 100 °C which typically applies to filling compounds used for communication cables and optical fibre cables. IEC 60811-302:2012 cancels and replaces Clause 10 of IEC 60811-5-1:1990, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There are no specific technical changes with respect to the previous edition, but see the Foreword to IEC 60811-100:2012.
This publication is to be read in conjunction with IEC 60811-100:2012.

  • Standard
    16 pages
    English and French language
    sale 15% off

IEC 60811-403:2012 specifies the method for the ozone resistance test, which typically applies to cross-linked compounds. IEC 60811-403:2012 cancels and replaces Clause 8 of IEC 60811-2-1:1998, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There are no specific technical changes with respect to the previous edition, but see the Foreword to IEC 60811-100:2012.
This publication is to be read in conjunction with IEC 60811-100:2012.

  • Standard
    24 pages
    English and French language
    sale 15% off

IEC 60811-405:2012 specifies the procedure for the thermal stability test which applies to PVC compounds. IEC 60811-405:2012 cancels and replaces Clause 9 of IEC 60811-3-2:1985, which is withdrawn. Full details of the replacements are shown in Annex A of IEC 60811-100:2012. There are no specific technical changes with respect to the previous edition, but see the Foreword to IEC 60811-100:2012.
This publication is to be read in conjunction with IEC 60811-100:2012.

  • Standard
    16 pages
    English and French language
    sale 15% off