This standard specifies the requirements for the performance, reliability and security characteristics of alarm transmission systems.
It covers the general requirements for connections providing signalling between an alarm system at a supervised premises and annunciation equipment at an alarm receiving centre.
EN 50136-1 Applies to transmission systems for all types of alarm messages such as fire, intrusion, access control, social alarm, etc. Different types of alarm system may in addition to ...
view more

    • sale 10% off
    • Amendment
      9 pages
      English language
    • e-Library read for
      1 day

These application guidelines include guidance on the application of the design, planning, operation, installation, commissioning and maintenance of alarm transmission systems for use in fire, I&HAS, Social Alarms and VSS applications. This document does NOT specify requirements. The requirements for ATS and ATE are specified in other parts of the EN 50136 series of standards.
These application guidelines are intended to assist those responsible for establishing an ATS(n) to ascertain the approp...
view more

    • sale 10% off
    • Technical specification
      22 pages
      English language
    • e-Library read for
      1 day

This Technical Specification specifies a protocol for point-to-point transmission of alarms and faults, as well as communications monitoring, between a Supervised Premises Transceiver and a Receiving Centre Transceiver using the Internet protocol (IP).
The protocol is intended for use over any network that supports the transmission of IP data. These include Ethernet, xDSL, GPRS, WiFi, UMTS and WIMAX.
The system performance characteristics for alarm transmission are specified in EN 50136-1 and ...
view more

    • sale 10% off
    • Technical specification
      55 pages
      English language
    • e-Library read for
      1 day

This International Standard specifies the requirements for an environmental management system
that an organization can use to enhance its environmental performance. This International Standard
is intended for use by an organization seeking to manage its environmental responsibilities in a
systematic manner that contributes to the environmental pillar of sustainability.
This International Standard helps an organization achieve the intended outcomes of its environmental
management system, whi...
view more

    • sale 10% off
    • Standard
      46 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Standard
      49 pages
      German language
    • e-Library read for
      1 day
    • sale 10% off
    • Standard – translation
      66 pages
      Slovenian and English language
    • e-Library read for
      1 day

ISO 9001:2015 specifies requirements for a quality management system when an organization:
a) needs to demonstrate its ability to consistently provide products and services that meet customer and applicable statutory and regulatory requirements, and
b) aims to enhance customer satisfaction through the effective application of the system, including processes for improvement of the system and the assurance of conformity to customer and applicable statutory and regulatory requirements.
All the r...
view more

    • sale 10% off
    • Standard
      42 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Standard – translation
      55 pages
      Slovenian and English language
    • e-Library read for
      1 day

This European Standard specifies the minimum equipment requirements for the performance, reliability, resilience, security and safety characteristics of the receiving centre transceiver (RCT) installed in ARC and used in alarm transmission systems.

    • sale 10% off
    • Standard
      25 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies the general equipment requirements for the performance, reliability, resilience, security and safety characteristics of supervised premises transceiver (SPT) installed in supervised premises and used in alarm transmission systems (ATS). A supervised premises transceiver can be a stand-alone device or an integrated part of an alarm system. These requirements also apply to SPT’s sharing means of interconnection, control, communication and power supplies with other ...view more

    • sale 10% off
    • Standard
      30 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60839 specifies the minimum functionality, performance requirements and test methods for electronic access control systems and components used for physical access (entry and exit) in and around buildings and protected areas. It does not include requirements for access point actuators and sensors. This standard is not intended to cover requirements for off premise transmission associated with intrusion or hold up alarm signals. This standard applies to electronic access control s...view more

    • sale 10% off
    • Standard
      61 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies the requirements for the performance, reliability and security characteristics of alarm transmission systems. It specifies the requirements for alarm transmission systems providing alarm transmission between an alarm system at a supervised premises and annunciation equipment at an alarm receiving centre. This European Standard applies to transmission systems for all types of alarm messages such as fire, intrusion, access control, social alarm, etc. Different type...view more

    • sale 10% off
    • Standard
      32 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Guide
      16 pages
      Slovenian language
    • e-Library read for
      1 day

D117/092: Standstill maintained (interim TS before EN status) (see BT119/DG5552/INF)

    • sale 10% off
    • Technical specification
      24 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Standard
      33 pages
      English language
    • e-Library read for
      1 day

Describes the requirements for standard serial data interfaces in alarm transmission systems. Gives an outline of how alarm transmission systems are connected and the various types of serial data interfaces that might be employed.

    • sale 10% off
    • Standard
      20 pages
      English language
    • e-Library read for
      1 day

Specifies the requirements for digital communicator systems using the public switched telephone network which are additional to those specified in IEC 60839-5-1 and IEC 60839-5-2. Covers switched connections providing event driven signalling between an alarm system and a remote centre.

    • sale 10% off
    • Standard
      9 pages
      English language
    • e-Library read for
      1 day
    • sale 15% off
    • Standard
      21 pages
      English and French language

Specifies the requirements for voice communicator systems using the public switched telephone network which are additional to those specified in IEC 60839-5-1 and IEC 60839-5-2. Covers switched connections providing event driven signalling between an alarm system and a remote centre.

    • sale 10% off
    • Standard
      8 pages
      English language
    • e-Library read for
      1 day
    • sale 15% off
    • Standard
      16 pages
      English and French language

Specifies the general requirements for equipment used in alarm transmission systems. Does not specify the equipment used to display the information at the alarm receiving centre or the installation of the equipment.

    • sale 10% off
    • Standard
      13 pages
      English language
    • e-Library read for
      1 day
    • sale 15% off
    • Standard
      20 pages
      English and French language

Specifies the requirements for alarm transmission systems using dedicated alarm transmission paths which are additional to those specified in IEC 60839-5-1 and IEC 60839-5-2. Covers dedicated connections providing signalling continuity between an alarm system and the presentation of alarm system information at an alarm receiving centre.

    • sale 10% off
    • Standard
      7 pages
      English language
    • e-Library read for
      1 day
    • sale 15% off
    • Standard
      36 pages
      English and French language

Specifies the general requirements for the performance, reliability and security characteristics of alarm transmission systems. Covers the general requirements for connections providing signalling between an alarm system and an alarm receiving centre.

    • sale 10% off
    • Standard
      17 pages
      English language
    • e-Library read for
      1 day
    • sale 15% off
    • Standard
      20 pages
      English and French language

ISO 10002:2004 provides guidance on the process of complaints handling related to products within an organization, including planning, design, operation, maintenance and improvement. The complaints-handling process described is suitable for use as one of the processes of an overall quality management system.
ISO 10002:2004 is not applicable to disputes referred for resolution outside the organization or for employment-related disputes.  
It is also intended for use by organizations of all sizes...
view more

    • sale 15% off
    • Standard
      23 pages
      English language
    • sale 10% off
    • Standard
      23 pages
      English language
    • e-Library read for
      1 day
    • sale 15% off
    • Standard
      24 pages
      French language
    • sale 10% off
    • Technical specification
      30 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Technical specification – translation
      43 pages
      Slovenian and English language
    • e-Library read for
      1 day
    • sale 10% off
    • Standard
      23 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Standard – translation
      23 pages
      Slovenian language
    • e-Library read for
      1 day

This European Standard specifies methods for the identification of hazardous situations leading to explosion  and the design and construction measures appropriate for the required safety. This is achieved by: - hazard identification; - risk assessment; - elimination or minimization of risk; - information for use. The safety of equipment, protective systems, and components can be achieved, as described in 5.7 of EN 414:1992, by removal of hazards and/or limiting the risk, i.e. a) by design withou...view more

    • sale 10% off