EN ISO 22829:2008
(Main)Resistance welding - Transformer-rectifier for welding guns with integrated transformers - Transformer-rectifier units operating at 1000 Hz frequency (ISO 22829:2007)
Resistance welding - Transformer-rectifier for welding guns with integrated transformers - Transformer-rectifier units operating at 1000 Hz frequency (ISO 22829:2007)
ISO 22829:2007 is applicable to transformer-rectifier units as used in electric resistance welding machines operating from a power supply with a frequency of 1 000 Hz, and of a rated value of the input voltage equal to or higher than 500 V. These transformer-rectifier units are primarily used in welding guns with an integrated transformer.
For these transformer units, ISO 22829:2007 supplements the requirements given in ISO 5826 and ISO 10656, which remain applicable except where amended by ISO 22829:2007.
Widerstandsschweißen - Transformatoren-Gleichrichter für Schweißzangen mit integrierten Transformatoren - Transformatoren- Gleichrichtereinheiten mit einer Arbeitsfrequenz von 1 000 Hz (ISO 22829:2007)
Diese Internationale Norm ist anwendbar für Transformatoren-Gleichrichtereinheiten die in Widerstandspress¬schweißmaschinen eingesetzt werden. Die Frequenz der Eingangsspannung ist auf 1 000 Hz festgelegt. Die Höhe der Eingangsspannung beträgt 500 V oder mehr. Die Transformatoren-Gleichrichtereinheiten werden überwiegend in Schweißzangen mit integriertem Transformator eingesetzt.
Die vorliegende Internationale Norm für Mittelfrequenztransformatoren ergänzt die Normen ISO 5826 und ISO 10656, welche anwendbar bleiben, soweit sie nicht durch die vorliegende Internationale Norm geändert werden.
Soudage par résistance - Transformateurs-redresseurs pour pinces de soudage à transformateur incorporé - Transformateurs-redresseurs alimentés sous une fréquence de 1000 Hz (ISO 22829:2007)
L'ISO 22829:2007 est applicable aux transformateurs-redresseurs utilisés dans les machines électriques de soudage par résistance alimentées sous une fréquence de 1 000 Hz, et dont la valeur nominale de la tension d'alimentation est égale ou supérieure à 500 V. Ces transformateurs-redresseurs sont surtout utilisés avec des pistolets de soudage à transformateur incorporé.
L'ISO 22829:2007 complète, pour ces transformateurs, les exigences énoncées dans l'ISO 5826 et l'ISO 10656; ces exigences restent applicables lorsqu'elles ne sont pas amendées par l'ISO 22829:2007.
Uporovno varjenje - Transformator-usmernik za varilne klešče z vgrajenimi transformatorji - Enota za delo pri frekvenci 1000 Hz (ISO 22829:2007)
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-junij-2008
8SRURYQRYDUMHQMH7UDQVIRUPDWRUXVPHUQLN]DYDULOQHNOHãþH]YJUDMHQLPL
WUDQVIRUPDWRUML(QRWD]DGHORSULIUHNYHQFL+],62
Resistance welding - Transformer-rectifier for welding guns with integrated transformers -
Transformer-rectifier units operating at 1000 Hz frequency (ISO 22829:2007)
Widerstandsschweißen - Transformatoren-Gleichrichter für Schweißzangen mit
integrierten Transformatoren - Transformator-/Gleichrichtereinheiten mit einer
Arbeitsfrequenz von 1 000 Hz (ISO 22829:2007)
Soudage par résistance - Transformateur redresseur pour pinces à transformateur
incorporé - Transformateur redresseur alimenté sous une fréquence de 1000 Hz (ISO
22829:2007)
Ta slovenski standard je istoveten z: EN ISO 22829:2008
ICS:
25.160.30 Varilna oprema Welding equipment
29.180 Transformatorji. Dušilke Transformers. Reactors
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN ISO 22829
NORME EUROPÉENNE
EUROPÄISCHE NORM
March 2008
ICS 25.160.30; 29.180
English Version
Resistance welding - Transformer-rectifier for welding guns with
integrated transformers - Transformer-rectifier units operating at
1000 Hz frequency (ISO 22829:2007)
Soudage par résistance - Transformateurs-redresseurs Widerstandsschweißen - Transformatoren-Gleichrichter für
pour pinces de soudage à transformateur incorporé - Schweißzangen mit integrierten Transformatoren -
Transformateurs-redresseurs alimentés sous une Transformator-/Gleichrichtereinheiten mit einer
fréquence de 1000 Hz (ISO 22829:2007) Arbeitsfrequenz von 1 000 Hz (ISO 22829:2007)
This European Standard was approved by CEN on 7 March 2008.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the
official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,
France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,
Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36 B-1050 Brussels
© 2008 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 22829:2008: E
worldwide for CEN national Members.
Contents Page
Foreword.3
Foreword
The text of ISO 22829:2007 has been prepared by Technical Committee ISO/TC 44 “Welding and allied
processes” of the International Organization for Standardization (ISO) and has been taken over as EN ISO
22829:2008 by Technical Committee CEN/TC 121 “Welding” the secretariat of which is held by DIN.
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by September 2008, and conflicting national standards shall be
withdrawn at the latest by September 2008.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.
Endorsement notice
The text of ISO 22829:2007 has been approved by CEN as a EN ISO 22829:2008 without any modification.
INTERNATIONAL ISO
STANDARD 22829
First edition
2007-02-15
Corrected version
2007-11-01
Resistance welding — Transformer-
rectifier for welding guns with integrated
transformers — Transformer-rectifier
units operating at 1 000 Hz frequency
Soudage par résistance — Transformateurs-redresseurs pour pistolets
de soudage à transformateur incorporé — Transformateurs-redresseurs
alimentés sous une fréquence de 1 000 Hz
Reference number
ISO 22829:2007(E)
©
ISO 2007
ISO 22829:2007(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In
the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.
© ISO 2007
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2007 – All rights reserved
ISO 22829:2007(E)
Contents Page
Foreword. iv
1 Scope . 1
2 Normative references . 1
3 Terms and definitions. 1
4 Power supply to the transformer-rectifier unit .3
5 Transformer types . 3
6 Dimensions. 4
7 Construction and additional equipment. 5
8 Marking . 6
9 Shipping. 6
10 Designation . 6
11 Tests. 7
Annex A (informative) Relationship between output current and duty factor . 13
Annex B (normative) Input voltage timing characteristics . 14
Annex C (normative) Dimensions of transformers. 15
Annex D (normative) Rating plate .24
Bibliography . 26
ISO 22829:2007(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 22829 was prepared by Technical Committee ISO/TC 44, Welding and allied processes, Subcommittee
SC 6, Resistance welding.
Requests for official interpretations of any aspect of this International Standard should be directed to the
Secretariat of ISO/TC 44/SC 6 via your national standards body. A complete listing of these bodies can be
found at www.iso.org.
This corrected version incorporates an updated second paragraph in 11.3.9.
iv © ISO 2007 – All rights reserved
INTERNATIONAL STANDARD ISO 22829:2007(E)
Resistance welding — Transformer-rectifier for welding guns
with integrated transformers — Transformer-rectifier units
operating at 1 000 Hz frequency
1 Scope
This International Standard is applicable to transformer-rectifier units as used in electric resistance welding
machines operating from a power supply with a frequency of 1 000 Hz, and of a rated value of the input
voltage equal to or higher than 500 V. These transformer-rectifier units are primarily used in welding guns with
an integrated transformer.
For these transformer units, this International Standard supplements the requirements given in ISO 5826 and
ISO 10656, which remain applicable except where amended by this International Standard.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
ISO 5826:1999, Resistance welding equipment — Transformers — General specifications applicable to all
transformers
ISO 17657-3, Resistance welding — Welding current measurement for resistance welding — Part 3: Current
sensing coil
ISO 17657-4, Resistance welding — Welding current measurement for resistance welding — Part 4:
Calibration system
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
transformer-rectifier unit
transformer incorporating a full-wave rectifier in its secondary circuit
3.2
input voltage
U
root-mean-square (RMS) value of the voltage applied to the primary terminals of the transformer-rectifier unit
3.3
rated supply voltage
U
1N
RMS value of the supply voltage (applied to the primary terminals) for which the transformer-rectifier unit is
constructed
ISO 22829:2007(E)
3.4
rectified voltage
U
2d
RMS value of the voltage at the output of the transformer-rectifier unit when a load resistance is connected
across the output terminals
3.5
input current
I
RMS value of the current at the input terminals of the transformer-rectifier unit
3.6
open circuit input current
I
1O
RMS value of the current at the input terminals of the transformer-rectifier unit with the output terminals open
circuit
3.7
permanent input current
I
1P
maximum RMS value of the current at the input terminals of the transformer-rectifier unit with 100 % duty
factor (X = 100 %), without exceeding the specified temperature limits
NOTE For calculation related to this International Standard, I = I / (N1/N2), where (N1/N2) is the transformer
1P 2P
turns ratio.
3.8
output d.c.
I
2d
RMS value of the direct current at the output terminals of the transformer-rectifier unit
3.9
permanent output current
I
2P
maximum RMS value of the output current delivered by the transformer-rectifier unit at 100 % duty factor
(X = 100 %), without exceeding the specified temperature limits
3.10
output current on load condition
I
2R
RMS value of the output current delivered by the transformer-rectifier unit with a load resistance R
3.11
apparent input power
S
power measured at the input terminals of the transformer-rectifier unit, or calculated by U × I
1 1
3.12
rated permanent input apparent power
S
1P
rated permanent appar
...
Questions, Comments and Discussion