EN 50413:2008/A1:2013
(Amendment)Basic standard on measurement and calculation procedures for human exposure to electric, magnetic and electromagnetic fields (0 Hz - 300 GHz)
Basic standard on measurement and calculation procedures for human exposure to electric, magnetic and electromagnetic fields (0 Hz - 300 GHz)
This European Standard gives elements to establish methods for measurement and calculation of quantities associated with the assessment of human exposure to electric, magnetic and electromagnetic fields (EMF) in the frequency range from 0 Hz to 300 GHz. The major intention of this Basic Standard is to give the common background and information to relevant EMF standards. This Basic Standard cannot go into details extensively due to the broad frequency range and the huge amount of possible applications. Therefore it is not possible to specify detailed calculation or measurement procedures in this Basic Standard. This standard provides general procedures only for those product and workplace categories for which there do not exist any relevant assessment procedures in any existing European EMF basic standard. If there exists an applicable European EMF standard focused on specific product or workplace categories then the assessment shall follow that standard. If an applicable European EMF standard does not exist, but an applicable assessment procedure in another European EMF standard does exist, then that assessment procedure shall be used. This standard deals with quantities that can be measured or calculated in free space, notably electric and magnetic field strength or power density, and includes the measurement and calculation of quantities inside the body that forms the basis for protection guidelines. In particular the standard provides information on - definitions and terminology, - characteristics of electric, magnetic and electromagnetic fields, - measurement of exposure quantities, - instrumentation requirements, - methods of calibration, - measurement techniques and procedures for evaluating exposure, - calculation methods for exposure assessment.
Grundnorm zu Mess- und Berechnungsverfahren der Exposition von Personen in elektrischen, magnetischen und elektromagnetischen Feldern (0 Hz bis 300 GHz)
Norme de base pour les procédures de mesures et de calculs pour l'exposition des personnes aux champs électriques, magnétiques et électromagnétiques (0 Hz - 300 GHz)
Osnovni standard za merjenje in izračunavanje izpostavljenosti ljudi električnim, magnetnim poljem in elektromagnetnim sevanjem (0 Hz - 300 GHz) - Dopolnilo A1
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-januar-2014
2VQRYQLVWDQGDUG]DPHUMHQMHLQL]UDþXQDYDQMHL]SRVWDYOMHQRVWLOMXGLHOHNWULþQLP
PDJQHWQLPSROMHPLQHOHNWURPDJQHWQLPVHYDQMHP+]*+]'RSROQLOR$
Basic standard on measurement and calculation procedures for human exposure to
electric, magnetic and electromagnetic fields (0 Hz - 300 GHz)
Grundnorm zu Mess- und Berechnungsverfahren der Exposition von Personen in
elektrischen, magnetischen und elektromagnetischen Feldern (0 Hz bis 300 GHz)
Norme de base pour les procédures de mesures et de calculs pour l'exposition des
personnes aux champs électriques, magnétiques et électromagnétiques (0 Hz - 300
GHz)
Ta slovenski standard je istoveten z: EN 50413:2008/A1:2013
ICS:
17.220.20 0HUMHQMHHOHNWULþQLKLQ Measurement of electrical
PDJQHWQLKYHOLþLQ and magnetic quantities
33.100.01 Elektromagnetna združljivost Electromagnetic compatibility
na splošno in general
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN 50413/A1
NORME EUROPÉENNE
October 2013
EUROPÄISCHE NORM
ICS 17.220.20; 33.100.01
English version
Basic standard on measurement and calculation procedures for human
exposure to electric, magnetic and electromagnetic fields (0 Hz - 300 GHz)
Norme de base pour les procédures de Grundnorm zu Mess- und
mesures et de calculs pour l'exposition Berechnungsverfahren der Exposition von
des personnes aux champs électriques, Personen in elektrischen, magnetischen
magnétiques et électromagnétiques und elektromagnetischen Feldern
(0 Hz - 300 GHz) (0 Hz bis 300 GHz)
This amendment A1 modifies the European Standard EN 50413:2008; it was approved by CENELEC on
2013-09-02. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this amendment the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CENELEC member into its own language and notified to the
CEN-CENELEC Management Centre has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany,
Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B - 1000 Brussels
© 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref.
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.