EN 60286-3:1998
(Main)Packaging of components for automatic handling - Part 3: Packaging of surface mount components on continuous tapes
Packaging of components for automatic handling - Part 3: Packaging of surface mount components on continuous tapes
Relates to the tape packaging of electronic components without leads or with lead stumps which are intended to be connected to electronic circuits. Includes only those dimensions which are essential for the taping of components for the above-mentioned purposes.
Gurtung und Magazinierung von Bauelementen für automatische Verarbeitung - Teil 3: Gurtung von oberflächenmontierbaren Bauelementen
Emballage de composants pour opérations automatisées - Partie 3: Emballage des composants appropriés au montage en surface en bandes continues
Concerne la mise en bande des composants électroniques sans fils de sorties ou avec tronçons de sorties destinés à être connectés à des circuits électroniques Seules les dimensions essentielles pour la mise sur bande de composants destinés aux opérations mentionnées ci-dessus sont données.
Packaging of components for automatic handling - Part 3: Packaging of surface mount components on continuous tapes (IEC 60286-3:1997)
General Information
Relations
This May Also Interest You
IEC 60286-1:2017(E) applies to the tape packaging of components with axial leads for use in electronic equipment. In general, the tape is applied to the component leads. It covers requirements for taping techniques used with equipment for the preforming of leads, automatic handling, insertion and other operations, and includes only those dimensions which are essential to the taping of components intended for the above-mentioned purposes. This edition includes the following significant changes with respect to the previous edition: a) a complete revision of the structure (detailed in Annex A) and reworked layout.
- Standard15 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 60286-1:2017(E) applies to the tape packaging of components with axial leads for use in electronic equipment. In general, the tape is applied to the component leads. It covers requirements for taping techniques used with equipment for the preforming of leads, automatic handling, insertion and other operations, and includes only those dimensions which are essential to the taping of components intended for the above-mentioned purposes. This edition includes the following significant changes with respect to the previous edition: a) a complete revision of the structure (detailed in Annex A) and reworked layout.
- Standard15 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 60335-2-39:2012 deals with the safety of electrically operated commercial multi-purpose cooking pans not intended for household and similar use, their rated voltage being not more than 250 V for single-phase appliances connected between one phase and neutral and 480 V for other appliances. This standard also deals with pressurized appliances and appliances with pressurized parts. These appliances are used for processing food for commercial consumption, for example in kitchens of restaurants, canteens, hospitals and in commercial enterprises such as bakeries, butcheries, etc. The electrical part of appliances making use of other forms of energy is also within the scope of this standard. As far as is practicable, this standard deals with the common hazards presented by these types of appliances. Attention is drawn to the fact that for appliances intended to be used in vehicles or on board ships or aircraft, additional requirements may be necessary. The principal changes in this edition as compared with the fifth edition of IEC 60335-2-39 are as follows (minor changes are not listed): - addition to definition of portable appliances, atmospheric multi-purpose cooking and rated pressure; - deletion of equipotential symbol 5021 of IEC 60417 covered by Part 1; - addition of instructions for multi-purpose cooking pans; - modification on leakage current permissible for portable class l appliances; - addition to abnormal test requirements; - addition to mechanical hazard test for multi-purpose cooking pans; - addition of construction test for multi-purpose cooking pans; - addition to construction requirements for lids and theirs grips; - addition to construction requirements for positioning of pressure reliefs; - addition to construction's fixed appliances which are moved forward and backward for cleaning purposes.
The attention of National Committees is drawn to the fact that equipment manufacturers and testing organizations may need a transitional period following publication of a new, amended or revised IEC publication in which to make products in accordance with the new requirements and to equip themselves for conducting new or revised tests. It is the recommendation of the committee that the content of this publication be adopted for implementation nationally not earlier than 12 months or later than 36 months from the date of publication. Keywords: Multi-purpose cooking pans.
- Draft21 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 60034-9:2021 specifies test methods for the determination of sound power level of rotating electrical machines and specifies maximum A-weighted sound power levels for factory acceptance testing of network-supplied, rotating electrical machines in accordance with lEC 60034-1, having methods of cooling according to lEC 60034-6 and degrees of protection according to lEC 60034-5, and having the following characteristics: - standard design, either AC or DC, without additional special electrical, mechanical, or acoustical modifications intended to reduce the sound power level - rated output from 1 kW (or kVA) up to and including 5 500 kW (or kVA) - rated speed not greater than 3 750 min–1 This fifth edition cancels and replaces the fourth edition, published in 2003 and its amendment 1, published in 2007. This edition includes the following significant technical changes with respect to the previous edition: a) In Table 2 and Table 3 cooling methods IC01, IC11, IC21 and IC31, IC71, IC81 are now covered. b) This edition adds Table 3 for 60 Hz machines, whereas Table 2, which covers only 50 Hz machines, has no change in levels. c) In Table 3, grade A is added to harmonize the highest levels seen in IEC and NEMA, whereas grade B was added to harmonize the lowest, more restrictive levels seen in IEC and NEMA. d) The clause “Determination of noise increments caused by converter supply” has been shifted to Annex B and renamed “Information on typical noise increments caused by converter supply”.
- Draft20 pagesEnglish languagesale 10% offe-Library read for×1 day
- 07-Nov-2024
- 12-Jun-2022
- 29.160
- 29.160.01
- 2014/35/EU
- M/511
- CLC/TC 2
IEC 60034-12:2024 is available as IEC 60034-12:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60034-12:2024 specifies the parameters for eight designs of starting performance of single-speed three-phase 50 Hz or 60 Hz cage induction motors in accordance with IEC 60034‑1 that: - have a rated voltage up to 1 000 V; - are intended for direct-on-line or star-delta starting; - are rated on the basis of duty type S1; - are constructed to any degree of protection as defined in IEC 60034-5 and explosion protection. This document also applies to dual voltage motors provided that the flux saturation level is the same for both voltages. This fourth edition cancels and replaces the third edition published in 2016. Aligned with the requirements for explosion protected motors from TC31 WG27 - new clause on methods for measuring locked-rotor current and torque; - new informative annex on the general current and torque characteristics with locked rotor; - new informative annex on correction of voltage and frequency; - aligned with the requirements for explosion protected motors from TC31 WG27.
- Draft20 pagesEnglish languagesale 10% offe-Library read for×1 day
- 07-Nov-2024
- 29.160.01
- 2014/35/EU
- M/511
- CLC/TC 2
This European Standard deals with the safety of electric heat pumps, sanitary hot water heat pumps and air conditioners, incorporating motor-compressors as well as hydronic fan coils units, dehumidifiers (with or without motor-compressors), thermoelectric heat pumps and partial units. Their maximum rated voltage being not more than 300 V for single phase appliances and 600 V for multi-phase appliances. Appliances not intended for normal household use but which nevertheless can be a source of danger to the public, such as appliances intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard.
- Draft22 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 60034-11:2020 is available as IEC 60034-11:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60034-11:2020 specifies requirements relating to the use of thermal protectors and thermal detectors incorporated into the stator windings or placed in other suitable positions in induction machines in order to protect them against serious damage due to thermal overloads. It applies to single-speed three-phase 50 Hz or 60 Hz cage induction motors in accordance with IEC 60034-1 and IEC 60034-12 that: - have a rated voltage up to 1 000 V; - are intended for direct-on-line or star-delta starting. The main changes with respect to the previous edition are: - the additional specification of winding temperature limits for temperature class 200 (N), - the increased limits of maximum winding temperatures for overloads with rapid variation, - the clarification that the motor winding may be permanently damaged after it has been exposed to temperatures - a clarification of the definition of indirect thermal protection, - a clarification on the test methods for larger motors.
- Draft13 pagesEnglish languagesale 10% offe-Library read for×1 day
- 07-Nov-2024
- 23-May-2021
- 29.160
- 29.160.01
- 2014/35/EU
- M/511
- CLC/TC 2
This European Standard deals with the safety of electric heat pumps, sanitary hot water heat pumps and air conditioners, incorporating motor-compressors as well as hydronic fan coils units, dehumidifiers (with or without motor-compressors), thermoelectric heat pumps and partial units. Their maximum rated voltage being not more than 300 V for single phase appliances and 600 V for multi-phase appliances. Appliances not intended for normal household use but which nevertheless can be a source of danger to the public, such as appliances intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard.
- Draft158 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 60704-2-10:2024 applies to ranges, ovens, steam ovens, grills and microwave ovens for household and similar use. This document does not apply to hobs. This document does not apply to appliances or parts of appliances that use gas energy. Requirements for the declaration of noise emission values are not within the scope of this document. This third edition cancels and replaces the second edition published in 2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) alignment with the fourth edition of IEC 60704-1:2021; b) alignment with IEC 60350-1:2023 regarding the definitions and settings; c) introduction of the measurement of the steam function; d) revision of settings and test parameters. This document is intended to be used in conjunction with IEC 60704-1:2021, Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Part 1: General requirements.
- Standard16 pagesEnglish languagesale 10% offe-Library read for×1 day
- 31-Oct-2024
- 17.140.20
- 97.040.20
- CLC/TC 59X
IEC 62271-211:2024 is applicable to single- and three-phase direct connections between gas-insulated metal-enclosed switchgear (GIS) for rated voltages above 52 kV and transformer arrangements to establish electrical and mechanical interchange ability and to determine the limits of supply for the transformer connection. This second edition cancels and replaces the first edition of IEC 62271-211:2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) re-numbering of clauses according to IEC 62271-1:2017, b) Clause 3: updating definition about bushing (3.1), updating some pressure definitions (3.6, 3.7, 3.8, 3.9), rewording definition about proctor density (3.11), new term very-fast-front overvoltage (3.12), c) Clause 5 (former clause 4): add a subclause 5.1 General, according to IEC 62271-1:2017 and IEC 62271-203:2022, 1) subclause 5.5: new first paragraph, rewording second paragraph, 2) subclause 5.8: modify the term "Rated duration of thermal short-time current" of the bushing, d) Clause 6 (former Clause 5): restructure and rewording of subclauses: 1) 6.1 (former 5.3): requirements about gas and vacuum tightness of the transformer bushing 2) 6.3 (former 5.2): harmonization with IEC 62271-203:2022 about typical maximum pressure in service for SF6, other gases and gas mixtures, 3) 6.4 (former 5.8), rewording 4) 6.5 (former 5.1), some rewording and modification 5) 6.6 (former 5.4), some rewording, updated references 6) 6.7 (former 5.5), some rewording 7) 6.8 (former 5.6), some rewording 8) 6.9 (former 5.7), slight rewording, e) Clause 7 (former clause 6) type tests: some rewording and clarifications about references, f) Clause 8 (former clause 7) routine tests: 1) 8.2 (former 7.2): add a paragraph about SF6-mixtures and other gases than SF6, 2) 8.3 (former 7.3): update reference to relevant on-site test according to IEC 62271‑203:2022, g) Clause 9 Guide to the selection of switchgear and controlgear (new): informative, to have a reference to IEC 62271-203:2022, h) Clause 11 (former 10): updated headline and updated reference according to IEC 62271‑1:2017, i) new Clauses 12 Safety and 13 Environmental aspects: Adding of references to safety and environmental aspects, j) correction of errors in Corrigendum 2 of IEC 62271-211:2017, k) modified orientation of Figure 1 to Figure 4 for easier reading of the tables.
- Standard28 pagesEnglish languagesale 10% offe-Library read for×1 day
- 31-Oct-2024
- 29.130.10
- CLC/TC 17AC