IEC 60691:2015/COR1:2016
(Corrigendum)Corrigendum 1 - Thermal-links - Requirements and application guide
Corrigendum 1 - Thermal-links - Requirements and application guide
Provides general rules for all electrotechnical components installed in power circuits, control and indicating circuits on rail rolling stock. It supplements the rules given in part 1 of IEC 60077. This part and the part 1 replaces IEC 60077 published in 1968.
Corrigendum 1 - Protecteurs thermiques - Exigences et guide d'application
Donne, en complément des règles énoncées dans la partie 1, les règles générales applicables à tous les composants électrotechniques installés dans les circuits de puissance, circuits auxiliaires, circuits de commande et de contrôle installés sur le matériel roulant ferroviaire. Cette partie avec la partie 1 remplace la CEI 60077 publiée en 1968
General Information
Relations
Standards Content (Sample)
IEC 2016
INTERNATIONAL ELECTROTECHNICAL COMMISSION
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
IEC 60691 IEC 60691
Edition 4.0 2015-10 Édition 4.0 2015-10
Thermal-links – Requirements and application Protecteurs thermiques – Exigences et guide
guide d'application
CORRIGENDUM 1
Corrections to the French version appear after the English text.
Les corrections à la version française sont données après le texte anglais.
Replace the existing Table 1 with the following new Table:
IEC 60691:2015-10/COR1:2016-08(en-fr)
– 2 – IEC 60691:2015/COR1:2016
IEC 2016
Table 1 – Test schedule
Clause or Test Specimen groups
Sub-clause
A B C D E F G H I J K
a Marking (Rub test) X X
a Marking (visual inspection only) X X
9 Constructional requirements
a Tensile forces X
9.2.2
a Thrust force X
9.2.3
a Bending/twist force X
9.2.4
a Resistance to tracking X
9.6
a Creepage distances and clearances X X
9.7
9.8 Temperature and humidity cycle X X X X X
conditioning
10 Electrical requirements
10.1 Dielectric strength (if applicable) X X X X X
10.2 Insulation resistance (if applicable) X X X X X
10.3 Interrupting current X X
10.4 Transient overload current X X X
11 Temperature tests
11.2 Check on T X
h
11.3 Check on T X X
f
11.4 Check on T followed by dielectric X X
m
test and insulation resistance
11.5 Ageing X X X X X
step 1 (optional) 21 days
step 2 (mandatory) 21 days
step 3 (mandatory) 14 days
step 4 (mandatory) 7 days
step 5 (mandatory) 7 days
step 6 (mandatory) 24 hours
10.1 Dielectric strength X X X X X X X X
10.2 Insulation resistance X X X X X X X X
12 Resistance to rusting
a Resistance to rusting (ferrous parts) X X X
If the conditions of voltage, power and current in 10.3.2.3, 10.3.2.4 and 10.3.2.5 are not covered by one test,
a
...
Questions, Comments and Discussion