ISO/TS 24858:2026
(Main)Plastics — Conducting materials — Eddy current measurement on spread carbon fibre tow
- Abstract
This test method defines test terms and specifies a standard method for evaluating the homogeneity of electrically conductive spread carbon fibre tow using eddy current measurement. The impedance in the width direction of the fibre is measured continuously, and the standard deviation of the measured impedance determines the homogeneity of the conductive material in fibre form.
- Status
- Published
- Publication Date
- 13-Oct-2026
- Technical Committee
- ISO/TC 61 - Plastics
- Current Stage
- 6060 - International Standard published - 60 Publication
- Start Date
- 14-Oct-2026
- Due Date
- 14-Oct-2026
- Completion Date
- 14-Oct-2026
ISO/TS 24858:2026 is an ISO Technical Specification for spread carbon fibre tow used as a conducting material. It specifies an eddy current method for evaluating homogeneity by measuring impedance continuously across the width direction of the fibre and using the standard deviation of the measured impedance as the basis for the result. It is intended for people who need a practical way to inspect conductive fibre form before processing, especially in quality control and material evaluation.
What does ISO/TS 24858:2026 specify?
ISO/TS 24858:2026 specifies a test method for electrically conductive spread carbon fibre tow. The standard defines the terms it uses, explains the impedance principle behind the method, and sets out how to prepare the specimen, carry out the measurement, and report the result.
The document is organized into these main parts:
- Clause 1 - Scope
- Clause 2 - Normative references
- Clause 3 - Terms and definitions
- Clause 4 - Background - Impedance
- Clause 5 - Specimen
- Clause 6 - Apparatus
- Clause 7 - Test conditions
- Clause 8 - Procedure
- Clause 9 - Report of the results
- Annex A - Informative measurement data for impedance analysis based on defects
| Annex | What it covers |
|---|---|
| Annex A | Eddy current measurement data for impedance analysis based on the presence of defects |
In practice, that structure matters because the standard is not only about taking a reading. It also tells users how to set up the specimen and equipment so that the impedance values can be compared in a consistent way.
What are the key requirements of ISO/TS 24858:2026?
ISO/TS 24858:2026 focuses on obtaining repeatable impedance measurements across the width of a spread carbon fibre tow and using the spread of those values to judge homogeneity. The main practical controls are specimen preparation, probe setup, test environment, and reporting of the measured variation.
Specimen preparation and size
Clause 5 says samples for fibre homogeneity measurement are preferably not impregnated with resin, and they should be taken randomly from a roll or bobbin without twists. The sample is fixed to a fibreglass veil with polyvinyl acetate glue, or by vacuum suction from below, to reduce movement during measurement.
Clause 5.2 also gives size guidance: the sample should be at least five times the measured probe diameter in the width direction, and longer than 100 mm in the length direction. That matters because the probe needs enough travel and enough measured points to show variation across the tow instead of only local detail.
Apparatus and probe setup
Clause 6 describes an eddy current testing system made up of an oscillator, a probe with a coil, and a voltmeter across the coil. Clause 6.1 links probe selection to the sample thickness and properties through standard penetration depth, which depends on frequency, magnetic permeability, and electrical conductivity.
Clause 6.2 says the sample should sit on an insulating sample stage such as glass, acrylic, or PVC to reduce interference from surrounding objects. If the table is conductive, the stage should be separated from it by at least 100 mm, or another grounding method should be used to avoid measurement error. Clause 6.3 adds that the probe must not touch the sample and the gap shall be kept constant at not more than 1 mm. In practice, this control is critical because probe distance affects impedance directly.
Test conditions
Clause 7 sets the test environment at 23 ± 2 °C and 50 ± 10 % humidity. The instrument and specimen should be allowed to stabilize before testing. That matters because the document notes that ambient temperature affects impedance, so stable conditions help keep the result comparable from sample to sample.
Procedure and number of readings
Clause 8 requires the sample to be placed close to the stage, the probe to be positioned vertically over the surface, and the impedance to be measured with the eddy current probe. At least three measurements are taken per sample under the same conditions to analyze the standard deviation of impedance. In practical terms, the standard is not satisfied by a single spot reading - it relies on repeated measurements to show whether the tow is uniform.
Reporting the result
Clause 9 requires the report to cover the test environment, apparatus, test conditions, and results. The report includes temperature range, humidity, probe details such as frequency and diameter, sample-stage material, gap, and number of measurements.
The result itself is reported as homogeneity with no unit. Clause 9 explains that homogeneity is expressed as a coefficient of variation calculated from the mean and standard deviation of the impedance values. For users, that means the reported value is a relative measure of variation, not a physical unit like ohm or millimetre.
How the method is interpreted
Clause 4 explains the eddy current principle and the impedance background used by the method. The document measures impedance in the width direction of the fibre, and the spread of those values is used to judge whether the conductive material is uniform. Annex A then shows how this approach can help distinguish defect conditions such as fibre breakage, fuzz, fibre splitting, or non-uniform arrangement.
What terms does ISO/TS 24858:2026 define?
ISO/TS 24858:2026 defines the key terms used to describe the specimen and the measurement result.
- Spread carbon fibre tow - a large bundle of continuous carbon fibre spread thinly and widely in the width direction.
- Eddy current - electrical currents induced within conductors by a time-varying magnetic field in the conductor.
- Impedance - the combined opposition in a circuit caused by resistance, inductance, and capacitance when a voltage is applied.
- Homogeneity - the degree to which a material has a uniform structure or composition throughout.
These definitions matter because the method is built around a specific material form and a specific electrical response. Using the same terms in the same way helps different labs interpret the result consistently.
Who uses ISO/TS 24858:2026?
ISO/TS 24858:2026 is used by people who need to check the uniformity of conductive fibre material before it is made into a product. The introduction points to quality control for raw fibre materials and to applications in next-generation electronic devices.
Typical users include:
- manufacturers of carbon fibre tow
- quality control and inspection teams
- test laboratories using eddy current methods
- engineers working with conductive fibres and textile-based functional materials
- users who need to identify localized non-uniformity or defects before processing
The standard is useful where the arrangement of fibres affects performance, because it gives a repeatable way to compare defect-free material with sections that contain breaks, fuzz, or uneven fibre density.
Which standards are used with ISO/TS 24858:2026?
ISO/TS 24858:2026 names and cites several related standards and documents that support its method.
- ISO 12718 - provides vocabulary for eddy current testing.
- IEC 62899-202-3:2019 - supplies a definition of eddy current and a related contactless measurement context.
- ISO 24584:2022 - is cited for the vacuum suction option used to fix the sample during preparation.
These references help users align the terminology and the sample-preparation approach with established practice in non-destructive testing and related measurement work.
What does the ISO/TS 24858:2026 document contain?
ISO/TS 24858:2026 contains the impedance background needed to understand the method, including the principle of impedance and the equations used to describe it. It also includes a figure showing the measurement apparatus and another showing probe measurement positions.
The document gives specimen preparation guidance, apparatus setup, test conditions, procedure steps, and the required report items. Annex A provides informative measurement data and graphical comparisons for defect analysis, including statistical treatment of impedance values. That annex is useful for users who want to relate measured variation to likely defect types during production or inspection.
Get Certified
Connect with accredited certification bodies for this standard

Control Union Certifications
Global certification for agriculture and sustainability.
Hohenstein Institut
Textile testing and certification.

Bureau Veritas Bangladesh
Bureau Veritas certification services in Bangladesh.
Sponsored listings
Frequently Asked Questions
ISO/TS 24858:2026 is a technical specification published by the International Organization for Standardization (ISO). Its full title is "Plastics — Conducting materials — Eddy current measurement on spread carbon fibre tow". This standard covers: This test method defines test terms and specifies a standard method for evaluating the homogeneity of electrically conductive spread carbon fibre tow using eddy current measurement. The impedance in the width direction of the fibre is measured continuously, and the standard deviation of the measured impedance determines the homogeneity of the conductive material in fibre form.
This test method defines test terms and specifies a standard method for evaluating the homogeneity of electrically conductive spread carbon fibre tow using eddy current measurement. The impedance in the width direction of the fibre is measured continuously, and the standard deviation of the measured impedance determines the homogeneity of the conductive material in fibre form.
ISO/TS 24858:2026 is classified under the following ICS (International Classification for Standards) categories: 19.100 - Non-destructive testing; 59.100.20 - Carbon materials. The ICS classification helps identify the subject area and facilitates finding related standards.
ISO/TS 24858:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 spread carbon fibre tow
- 3.2 eddy current
- 3.3 impedance
- 3.4 homogeneity
- 4 Background — Impedance
- 5 Specimen
- 5.1 Sampling
- 5.2 Size
- 6 Apparatus
- 6.1 Probe
- 6.2 Sample stage
- 6.3 Gap
- 7 Test conditions
- 8 Procedure
- 9 Report of the results
- 9.1 General
- 9.2 Test environment
- 9.3 Test apparatus
- 9.4 Test conditions
- 9.5 Test results
- Annex A
- 11 Row 12 Row 13 Row 14 Row 15 Row 16 Row 17 Row 18 Row 19 Row 20 Row
- 21 Row 22 Row 23 Row 24 Row 25 Row 26 Row 27 Row 28 Row 29 Row 30 Row
- 31 Row 32 Row 33 Row 34 Row 35 Row 36 Row 37 Row 38 Row 39 Row 40 Row
- 41 Row 42 Row 43 Row 44 Row 45 Row 46 Row 47 Row 48 Row 49 Row 50 Row
- 11 Row 12 Row 13 Row 14 Row 15 Row 16 Row 17 Row 18 Row 19 Row 20 Row
- 21 Row 22 Row 23 Row 24 Row 25 Row 26 Row 27 Row 28 Row 29 Row 30 Row
- 31 Row 32 Row 33 Row 34 Row 35 Row 36 Row 37 Row 38 Row 39 Row 40 Row
- 41 Row 42 Row 43 Row 44 Row 45 Row 46 Row 47 Row 48 Row 49 Row 50 Row
- 11 Row 12 Row 13 Row 14 Row 15 Row 16 Row 17 Row 18 Row 19 Row 20 Row
- 21 Row 22 Row 23 Row 24 Row 25 Row 26 Row 27 Row 28 Row 29 Row 30 Row
- 31 Row 32 Row 33 Row 34 Row 35 Row 36 Row 37 Row 38 Row 39 Row 40 Row
- 41 Row 42 Row 43 Row 44 Row 45 Row 46 Row 47 Row 48 Row 49 Row 50 Row
- 11 Row 12 Row 13 Row 14 Row 15 Row 16 Row 17 Row 18 Row 19 Row 20 Row
- 21 Row 22 Row 23 Row 24 Row 25 Row 26 Row 27 Row 28 Row 29 Row 30 Row
- 31 Row 32 Row 33 Row 34 Row 35 Row 36 Row 37 Row 38 Row 39 Row 40 Row
- 41 Row 42 Row 43 Row 44 Row 45 Row 46 Row 47 Row 48 Row 49 Row 50 Row
- 11 Row 12 Row 13 Row 14 Row 15 Row 16 Row 17 Row 18 Row 19 Row 20 Row
- 21 Row 22 Row 23 Row 24 Row 25 Row 26 Row 27 Row 28 Row 29 Row 30 Row
- 31 Row 32 Row 33 Row 34 Row 35 Row 36 Row 37 Row 38 Row 39 Row 40 Row
- 41 Row 42 Row 43 Row 44 Row 45 Row 46 Row 47 Row 48 Row 49 Row 50 Row
- 11 Row 12 Row 13 Row 14 Row 15 Row 16 Row 17 Row 18 Row 19 Row 20 Row
- 21 Row 22 Row 23 Row 24 Row 25 Row 26 Row 27 Row 28 Row 29 Row 30 Row
- 31 Row 32 Row 33 Row 34 Row 35 Row 36 Row 37 Row 38 Row 39 Row 40 Row
- 41 Row 42 Row 43 Row 44 Row 45 Row 46 Row 47 Row 48 Row 49 Row 50 Row
- 11 Row 12 Row 13 Row 14 Row 15 Row 16 Row 17 Row 18 Row 19 Row 20 Row
- 21 Row 22 Row 23 Row 24 Row 25 Row 26 Row 27 Row 28 Row 29 Row 30 Row
- 31 Row 32 Row 33 Row 34 Row 35 Row 36 Row 37 Row 38 Row 39 Row 40 Row
- 41 Row 42 Row 43 Row 44 Row 45 Row 46 Row 47 Row 48 Row 49 Row 50 Row
- 11 Row 12 Row 13 Row 14 Row 15 Row 16 Row 17 Row 18 Row 19 Row 20 Row
- 21 Row 22 Row 23 Row 24 Row 25 Row 26 Row 27 Row 28 Row 29 Row 30 Row
- 31 Row 32 Row 33 Row 34 Row 35 Row 36 Row 37 Row 38 Row 39 Row 40 Row
- 41 Row 42 Row 43 Row 44 Row 45 Row 46 Row 47 Row 48 Row 49 Row 50 Row
- 11 Row 12 Row 13 Row 14 Row 15 Row 16 Row 17 Row 18 Row 19 Row 20 Row
- 21 Row 22 Row 23 Row 24 Row 25 Row 26 Row 27 Row 28 Row 29 Row 30 Row
- 31 Row 32 Row 33 Row 34 Row 35 Row 36 Row 37 Row 38 Row 39 Row 40 Row
- 41 Row 42 Row 43 Row 44 Row 45 Row 46 Row 47 Row 48 Row 49 Row 50 Row
- 11 Row 12 Row 13 Row 14 Row 15 Row 16 Row 17 Row 18 Row 19 Row 20 Row
- 21 Row 22 Row 23 Row 24 Row 25 Row 26 Row 27 Row 28 Row 29 Row 30 Row
- 31 Row 32 Row 33 Row 34 Row 35 Row 36 Row 37 Row 38 Row 39 Row 40 Row
- 41 Row 42 Row 43 Row 44 Row 45 Row 46 Row 47 Row 48 Row 49 Row 50 Row
- 11 Row 12 Row 13 Row 14 Row 15 Row 16 Row 17 Row 18 Row 19 Row 20 Row
- 21 Row 22 Row 23 Row 24 Row 25 Row 26 Row 27 Row 28 Row 29 Row 30 Row
- 31 Row 32 Row 33 Row 34 Row 35 Row 36 Row 37 Row 38 Row 39 Row 40 Row
- 41 Row 42 Row 43 Row 44 Row 45 Row 46 Row 47 Row 48 Row 49 Row 50 Row
- 11 Row 12 Row 13 Row 14 Row 15 Row 16 Row 17 Row 18 Row 19 Row 20 Row
- 21 Row 22 Row 23 Row 24 Row 25 Row 26 Row 27 Row 28 Row 29 Row 30 Row
- 31 Row 32 Row 33 Row 34 Row 35 Row 36 Row 37 Row 38 Row 39 Row 40 Row
- 41 Row 42 Row 43 Row 44 Row 45 Row 46 Row 47 Row 48 Row 49 Row 50 Row
- 11 Row 12 Row 13 Row 14 Row 15 Row 16 Row 17 Row 18 Row 19 Row 20 Row
- 21 Row 22 Row 23 Row 24 Row 25 Row 26 Row 27 Row 28 Row 29 Row 30 Row
- 31 Row 32 Row 33 Row 34 Row 35 Row 36 Row 37 Row 38 Row 39 Row 40 Row
- 41 Row 42 Row 43 Row 44 Row 45 Row 46 Row 47 Row 48 Row 49 Row 50 Row
- 11 Row 12 Row 13 Row 14 Row 15 Row 16 Row 17 Row 18 Row 19 Row 20 Row
- 21 Row 22 Row 23 Row 24 Row 25 Row 26 Row 27 Row 28 Row 29 Row 30 Row
- 31 Row 32 Row 33 Row 34 Row 35 Row 36 Row 37 Row 38 Row 39 Row 40 Row
Introduction
As technologies for the commercialization of textile materials have advanced, the development of various functional materials based on fibres has increased. Conductive fibres are flexible and highly elastic materials with significant potential for application in next-generation electronic devices, and carbon fibres are also one of the conductive materials that exhibit electrical conductivity. The homogeneity of a conductive material is an important factor in determining the performance of the final product, and from a quality control perspective, it is necessary to have a method to analyse the distribution status of the raw material before it is processed. In the case of carbon fibres, a conductive material in the form of fibres, it is important to manage the arrangement of the fibres because the degree to which the filament strands are arranged can cause performance degradation in localized areas. Optical image analysis is a common method for checking the homogeneity of filaments in carbon fibres and can be used to analyse the arrangement of filaments on the surface, but it has limitations in analysing the presence and density of filaments arranged in the thickness direction. A method for continuously measuring the homogeneity of carbon fibres with large surface areas is eddy current measurement, which utilizes electrical conductivity properties. An eddy current measurement is used to detect discontinuities in materials that conduct electricity. This method is a reliable measurement that can identify materials with low electrical conductivity, such as spread carbon fibre tow, making it applicable to a wide range of industries. This document specifies a standard method for evaluating the homogeneity of a spread carbon fibre tow, a conductive fibre, using eddy current measurement. Annex A gives the eddy current measurement data for impedance analysis based on the presence of defects.
Technical Specification ISO/TS 24858:2026(en) Plastics — Conducting materials — Eddy current measurement on spread carbon fibre tow
1 Scope
This test method defines test terms and specifies a standard method for evaluating the homogeneity of electrically conductive spread carbon fibre tow using eddy current measurement. The impedance in the width direction of the fibre is measured continuously, and the standard deviation of the measured impedance determines the homogeneity of the conductive material in fibre form.
2 Normative references
There are no normative references in this document.
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https:// www .iso .org/ obp
- IEC Electropedia: available at https:// www .electropedia .org/
3.1 spread carbon fibre tow
large bundle of continuous carbon fibre spread thinly and widely in the width direction
3.2 eddy current
electrical currents induced within conductors by a time-varying magnetic field in the conductor [SOURCE: IEC 62899-202-3:2019, 3.2]
3.3 impedance
value represented by the combined effect of a circuit's resistance, inductance, and capacitance, which interferes when a voltage is applied to the circuit
3.4 homogeneity
degree of a state of being of a similar kind or of having a uniform structure or composition throughout
4 Background — Impedance
Eddy current instruments work on the principle that an electrically conductive sample is placed in an electromagnetic field generated by a probe system, which causes an eddy current to flow. Impedance is the total opposition a circuit presents to the flow of alternating current and is calculated as shown in Formulae (1) and (2), including resistance, inductive reactance, and capacitive reactance. For eddy current testing, capacitive reactance is usually not present, so impedance is calculated with Formula (3). As shown
ISO/TS 24858:2026(en) in Figure 1, the impedance value is calculated by the amount of resistance (horizontal line), the amount of [5] inductive reactance (vertical line), and the amount of impedance (diagonal line) . ZRXX (1) Lc
ZR XX (2)
Lc
ZRX (3) L where Z is the complex impedance (ohm); Z is the magnitude of the impedance (ohm); R is the resistance (ohm); X is the inductive reactance (ohm); L X is the capacitive reactance (ohm).
C Key R resistance XX- reactance LC Z impedance Z impedance amplitude ϕ phase angle Figure 1 — Principle of impedance
5 Specimen
5.1 Sampling
Samples for fibre homogeneity measurements are preferably not impregnated with resin. Randomly take a sample without twists from a roll or bobbin of product and fix it onto a fibreglass veil using polyvinyl acetate (PVA) glue. Ensure that the width and density do not change during sample fixation. The purpose of
ISO/TS 24858:2026(en) fixing the sample with PVA glue to the fibreglass veil is to minimize the floating of the sample. Alternatively, the sample can be fixed by vacuum suction from the bottom of the sample. See ISO 24584.
5.2 Size
The size of the sample should be at least five times larger than the measured diameter of the probe in the width direction, and a sample longer than 100 mm should be prepared in the length direction.
6 Apparatus
Eddy current testing instruments consists of an oscillator that generates alternating current electricity, a probe with a coil connected to a direct current power supply, and a voltmeter that can measure the voltage across the coil.
6.1 Probe
It is recommended to select a probe with an appropriate standard penetration depth based on the thickness and characteristics of the sample. The standard penetration depth varies with electrical conductivity, magnetic permeability, and frequency, and the standard penetration depth for eddy current inspection is calculated by the Formula (4).
(4) ··f · where δ is the standard penetration depth (millimetre); π is the ratio of the circumference of a circle to its diameter; f is the frequency (Hz); µ is the magnetic permeability (H/m); σ is the electrical conductivity (micro ohm-centimetre).
6.2 Sample stage
The sample should be placed on top of a sample stage made of a glass plate or insulating material such as acrylic, PVC, etc. to minimize induced currents due to interference from other objects. The sample stage should be separated by at least 100 mm depending on the material of the table, especially if it is an electrically conductive material such as metal. Alternatively, a separate grounding method can be devised to prevent measurement errors caused by static electricity.
ISO/TS 24858:2026(en) Key 1 probe 2 induction coil 3 sample, conductive materials 4 sample stage, insulating material 5 table Figure 2 — Apparatus of eddy-current measurement
6.3 Gap
Impedance can be affected by the distance between the sample and the probe. The probe and sample shall not be in direct contact and the gap shall be kept at a constant distance of not more than 1 mm.
7 Test conditions
The ambient temperature affects impedance of the sample when measuring eddy currents. Therefore, time should be allowed for the instruments and sample to stabilize to the test temperature before testing, and it is desirable that the conditions remain as constant as possible during the measurement to increase the reliability of the measurement.
- Temperature : (23 ± 2) °C
- Humidity : (50 ± 10) %
8 Procedure
1) Place the sample closely attached to the sample stage.
NOTE Mark the position of the sample to be measured with the probe. 2) The probe shall be positioned on the surface of the sample facing vertically, and measured impedance using eddy current probe.
3) Take at least three measurements per sample under the same conditions to analyse the impedance standard deviation.
ISO/TS 24858:2026(en)
9 Report of the results
9.1 General
The report shall include the following items.
9.2 Test environment
a) Temperature range b) Humidity
9.3 Test apparatus
a) Type of probe (frequency, diameter, etc.) b) Material of the sample stage
9.4 Test conditions
a) Gap b) Number of measurements
9.5 Test results
Homogeneity (No units); Since the homogeneity is expressed as a coefficient of variation value calculated as a ratio of the mean and standard deviation of the impedance value, there is no unit. The homogeneity of spread carbon fibre tow can be calculated as the mean and standard deviation of the impedance values in the width direction (row direction) measured continuously.
ISO/TS 24858:2026(en)
Annex A
(informative)
Eddy current measurement data for impedance analysis based on the presence of defects A.1 Test sample - Materials : T700-12K Spread carbon fibre tow A.2 Test conditions - Probe: Differential probe (radius 1,0 mm, frequency 27 MHz) - Sample stage: Glass plate - Overlap of the probe's measured diameter: 0 % - Gap between sample and probe: less than 1,0 mm See ISO 24584.
...