Concrete roofing tiles and fittings for roof covering and wall cladding - Product specifications

This European Standard specifies requirements for concrete roofing tiles and fittings for pitched roof coverings and wall cladding and lining.
Concrete roofing tiles and fittings may incorporate surface coatings and glued concrete components.
NOTE 1   Information on surface characteristics is given in Annex A.
NOTE 2   Information on the performance of roof and wall assemblies is given in Annex B.

Dach- und Formsteine aus Beton für Dächer und Wandbekleidungen - Produktanforderungen

Diese Europäische Norm legt Anforderungen an Dach- und Formsteine aus Beton für geneigte Dächer sowie für Innen- und Außenwandbekeidungen fest.
Dach- und Formsteine aus Beton können eine Oberflächenbeschichtung aufweisen und aus zusammengeklebten Betonbauteilen bestehen.
ANMERKUNG 1 Anhang A enthält Informationen zur Oberflächenbeschaffenheit.
ANMERKUNG 2 Anhang B enthält Informationen zum Verhalten von Dacheindeckungen und Wandbekleidungen.

Tuiles et accessoires en béton pour couverture et bardage - Spécifications des produits

La présente Norme européenne définit les prescriptions relatives aux tuiles et accessoires en béton destinés
aux toitures avec pente et aux bardages.
Les tuiles et accessoires en béton peuvent être pourvus de revêtements de surface et de composants en
béton assemblés par collage.
NOTE 1 Des informations sur les caractéristiques de surface sont données en Annexe A.
NOTE 2 Des informations sur les performances des assemblages pour toiture et bardage sont données en Annexe B.

Betonski strešniki in fazonski kosi za prekrivanje streh in oblaganje sten - Specifikacije za izdelek

Ta evropski standard določa zahteve za betonske strešnike in fazonske kose za prekrivanje dvokapnih streh in oblaganje sten. Betonski strešniki in fazonski kosi lahko vključujejo površinske premaze in prilepljene betonske komponente.

General Information

Status
Withdrawn
Publication Date
16-Nov-2011
Withdrawal Date
13-Mar-2017
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
14-Mar-2017
Due Date
06-Apr-2017
Completion Date
14-Mar-2017

RELATIONS

Buy Standard

Standard
SIST EN 490:2012 - Standard je bil natisnjen za čitalnico.
English language
27 pages
sale 10% off
Preview
sale 10% off
Preview

e-Library read for
1 day

Standards Content (sample)

SLOVENSKI STANDARD
SIST EN 490:2012
01-januar-2012
1DGRPHãþD
SIST EN 490:2005
SIST EN 490:2005/A1:2006
Betonski strešniki in fazonski kosi za prekrivanje streh in oblaganje sten -
Specifikacije za izdelek

Concrete roofing tiles and fittings for roof covering and wall cladding - Product

specifications
Dach- und Formsteine aus Beton für Dächer und Wandbekleidungen -
Produktanforderungen

Tuiles et accessoires en béton pour couverture et bardage - Spécifications des produits

Ta slovenski standard je istoveten z: EN 490:2011
ICS:
91.060.20 Strehe Roofs
91.100.30 Beton in betonski izdelki Concrete and concrete
products
SIST EN 490:2012 en,fr,de

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN 490:2012
---------------------- Page: 2 ----------------------
SIST EN 490:2012
EUROPEAN STANDARD
EN 490
NORME EUROPÉENNE
EUROPÄISCHE NORM
October 2011
ICS 91.100.30 Supersedes EN 490:2004
English Version
Concrete roofing tiles and fittings for roof covering and wall
cladding - Product specifications

Tuiles et accessoires en béton pour couverture et bardage - Dach- und Formsteine aus Beton für Dächer und

Spécifications des produits Wandbekleidungen - Produktanforderungen
This European Standard was approved by CEN on 18 September 2011.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European

Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national

standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.

This European Standard exists in three official versions (English, French, German). A version in any other language made by translation

under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same

status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,

Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland,

Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.

EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: Avenue Marnix 17, B-1000 Brussels

© 2011 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 490:2011: E

worldwide for CEN national Members.
---------------------- Page: 3 ----------------------
SIST EN 490:2012
EN 490:2011 (E)
Contents
Page

Foreword ..............................................................................................................................................................3

1 Scope ......................................................................................................................................................4

2 Normative references ............................................................................................................................4

3 Terms and definitions ...........................................................................................................................4

4 Symbols and abbreviations ..................................................................................................................5

5 Requirements .........................................................................................................................................6

6 Evaluation of conformity .................................................................................................................... 10

7 Sampling .............................................................................................................................................. 11

8 Designation system ............................................................................................................................ 13

9 Marking and labelling ......................................................................................................................... 14

10 Documents .......................................................................................................................................... 14

Annex A (informative) Surface characteristics ............................................................................................ 15

Annex B (informative) Performance of assemblies of roofing tiles and fittings ...................................... 16

Annex C (normative) Fasteners and fixings ................................................................................................ 17

Annex D (normative) Sampling procedure ................................................................................................... 18

Annex ZA (informative) Clauses of this European Standard addressing the provisions of the EU

Construction Products Directive ....................................................................................................... 19

Bibliography ..................................................................................................................................................... 27

---------------------- Page: 4 ----------------------
SIST EN 490:2012
EN 490:2011 (E)
Foreword

This document (EN 490:2011) has been prepared by Technical Committee CEN/TC 128 “Roof covering

products for discontinuous laying and products for wall cladding”, the secretariat of which is held by NBN.

This European Standard shall be given the status of a national standard, either by publication of an identical

text or by endorsement, at the latest by April 2012, and conflicting national standards shall be withdrawn at the

latest by July 2013.

Attention is drawn to the possibility that some of the elements of this document may be the subject of patent

rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.

This document supersedes EN 490:2004.

This document has been prepared under a mandate given to CEN by the European Commission and the

European Free Trade Association, and supports essential requirements of EU Directive(s).

For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document.

This edition incorporates minor technical changes including reaction to fire requirements.

According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following

countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech

Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,

Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,

Sweden, Switzerland and the United Kingdom.
---------------------- Page: 5 ----------------------
SIST EN 490:2012
EN 490:2011 (E)
1 Scope

This European Standard specifies requirements for concrete roofing tiles and fittings for pitched roof coverings

and wall cladding and lining.

Concrete roofing tiles and fittings may incorporate surface coatings and glued concrete components.

NOTE 1 Information on surface characteristics is given in Annex A.

NOTE 2 Information on the performance of roof and wall assemblies is given in Annex B.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated

references, only the edition cited applies. For undated references, the latest edition of the referenced

document (including any amendments) applies.

EN 491:2011, Concrete roofing tiles and fittings for roof covering and wall cladding — Test methods

ENV 1187, Test methods for external fire exposure to roofs

EN 13238, Reaction to fire tests for building products — Conditioning procedures and general rules for

selection of substrates

EN 13823, Reaction to fire tests for building products — Building products excluding floorings exposed to the

thermal attack by a single burning item

EN 13501-1, Fire classification of construction products and building elements — Part 1: Classification using

data from reaction to fire tests

EN 13501-5, Fire classification of construction products and building elements — Part 5: Classification using

data from external fire exposure to roof tests

EN ISO 1716, Reaction to fire tests for products — Determination of the gross heat of combustion (calorific

value) (ISO 1716:2010)
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
aggregate

concrete component consisting of uncrushed and/or crushed natural and/or artificial mineral substances with

particle sizes and shapes suitable for the production of concrete
3.2
additive

finely divided material that may be added to concrete in order to improve certain properties or to achieve

special properties
3.3
pigment
additive intended to add colour to the concrete
---------------------- Page: 6 ----------------------
SIST EN 490:2012
EN 490:2011 (E)
3.4
admixture

material which is added in small quantities relative to the mass of the cement before or during mixing or during

an additional mixing operation, causing required modifications to the properties
3.5
cement

hydraulic binder, i.e. finely ground inorganic material, which, when mixed with water, forms a paste which sets

by means of hydration reactions and processes and which, after hardening, retains its strength and stability

3.6
fitting

component, of concrete, that is complementary to the tiles and has a special function

NOTE Fittings may contain inserts of other materials.
3.6.1
coordinated fitting

fitting that is intended to align or interlock with the tiles with which it is to be laid (e.g. interlocking verge tile,

interlocking ventilation tile, tile-and-a-half, aligning valley tile, interlocking or aligning angle tiles)

3.7
valley tile
fitting for use at a meeting of two roof pitches forming a re-entrant angle
3.8
interlocking tile
profiled or flat tile which has a side lock, with or without a head lock feature
3.9
non-interlocking tile
profiled or flat tile without interlocks
3.10
tile with a regular front edge

tile (interlocking or non-interlocking) which, by design, has a constant or regularly varying hanging length

across the width
3.11
tile with an irregular front edge

tile (interlocking or non-interlocking), which, by design, has an irregular varying hanging length across the

width
4 Symbols and abbreviations

For the purposes of this document, the following symbols and abbreviations apply.

l hanging length of a tile
l , l hanging edge length of a tile, as defined in EN 491:2011, Clause 4
2 3
c cover width of one tile
c cover width closed up value of 10 tiles
c cover width drawn out value of 10 tiles
d profile depth of a tile
F minimum transverse strength of all tiles
min
F transverse strength of an individual tile
IL interlocking
NL non-interlocking
---------------------- Page: 7 ----------------------
SIST EN 490:2012
EN 490:2011 (E)
RF regular front edge
IF irregular front edge
/ not applicable or not declared characteristic for designation system
5 Requirements
5.1 Materials

The concrete used in the manufacture of tiles and fittings shall be formed by mixing cement, aggregate and

water and produced by the hardening of the cement paste (cement and water).

NOTE In addition to the basic components, the concrete may also contain pigments, admixtures and/or additives.

5.2 Dimensions
5.2.1 Hanging length and squareness

The tile hanging length shall be declared in the manufacturer’s technical specification. For tiles with a regular

front edge, the values of l shall be ± 4 mm of the manufacturer’s declared value when tested in accordance

with EN 491:2011, 5.2.

The squareness for tiles with nominally constant hanging length, when tested in accordance with EN 491:2011,

5.2.2.1, shall be calculated as the difference between values l and l and shall be not greater than 4 mm.

2 3

This sub-clause does not apply for tiles that are designed, for example for aesthetic reasons, with an irregular

front edge.
5.2.2 Cover width
5.2.2.1 General

The tile cover width c shall be declared in the manufacturer’s technical specification.

NOTE The cover width shunts may also be declared in the manufacturer’s technical specification.

This sub-clause does not apply for tiles that are designed, for example for aesthetic reasons, with a randomly

varying cover width.
5.2.2.2 Interlocking tiles

When tiles with cover width shunts declared by the manufacturer are tested in accordance with EN 491:2011,

5.3.3.1, the cover width shall conform to the following:
 c /10 ≥ c + declared “plus cover width shunt”;
wd w
 c /10 ≤ c - declared “minus cover width shunt”.
wc w

When tiles without cover width shunts, and tiles with cover width shunt but not declared by the manufacturer,

are tested in accordance with EN 491:2011, 5.3.3.1, the mean cover width shall be ± 5 mm of the

manufacturer’s declared cover width.
5.2.2.3 Non-interlocking tiles

When non-interlocking tiles are tested in accordance with EN 491:2011, 5.3.3.2, the mean cover width shall

be ± 3 mm of the manufacturer’s declared value.
---------------------- Page: 8 ----------------------
SIST EN 490:2012
EN 490:2011 (E)
5.2.3 Flatness

When tiles are tested in accordance with EN 491:2011, 5.4, the gap between any designed contact point and

the flat surface shall not exceed 3 mm or c /100 mm to the nearest millimetre, whichever is the greater.

This sub-clause does not apply where the manufacturer declares that:

 tiles are designed to have less than four contact points to a flat surface, and/or

 tiles are designed to be irregular in flatness.
5.2.4 Fittings

The manufacturer shall identify and declare the dimensions and tolerances and method of measurement of

the fitting relevant to its use. Where relevant, the tile element of a coordinated fitting shall conform to 5.2.1,

5.2.2 and 5.2.3.
5.3 Mass

The mass of tiles and fittings shall be declared in the manufacturer’s technical specification.

When tiles are tested in accordance with EN 491:2011, 5.5, the mean mass shall be:

a) manufacturer’s declared mass ± 0,2 kg for tiles with a declared mass not greater than 2 kg;

b) manufacturer’s declared mass ± 10 % for tiles with a declared mass greater than 2 kg.

5.4 Fixing holes (where provided)

Fixing holes, where provided, shall be arranged so that an intended connection between the tiles and/or

fittings and the batten can be achieved.

NOTE Information on fasteners and fixings is given in Annex C. Details of the size and position of the fixing holes

may be given in the manufacturer’s technical and/or commercial literature.
5.5 Mechanical resistance (transverse strength)
When tiles are tested in accordance with EN 491:2011, 5.6:
a) value of F shall be not less than the appropriate value given in Table 1, or
min

b) number of individual tiles with transverse strength values (F) less than the appropriate value in

Table 1, shall be not more than the appropriate acceptance value in 7.3.

Tiles tested prior to 28 days after manufacture shall be deemed to conform if they reach at least 80 % of the

values specified in Table 1 and the manufacturer can demonstrate statistically that the values given in Table 1

are achieved at 28 days.

Fittings shall conform to 5.2.4 and 5.7.2 (and 5.7.3 in the case of valley tiles).

---------------------- Page: 9 ----------------------
SIST EN 490:2012
EN 490:2011 (E)
Table 1 — Minimum transverse strength F of tiles
min
Non-interlocking
Interlocking tiles
tiles
Property
Profiled Flat
Profile depth d > 20mm 20 mm ≥ d ≥ 5 mm d < 5mm
c (mm) ≥ 300 ≤ 200 ≥ 300 ≤ 200 ≥ 300 ≤ 200
F (N) 2 000 1 400 1 400 1 000 1 200 800 550
min

The profile depth (d) shall be declared by the manufacturer and, if d < 20 mm, shall be measured in

accordance with EN 491:2011, 5.6.4.1.

For interlocking tiles between 200 mm and 300 mm cover width, the minimum transverse strength shall be

determined by linear interpolation between the values given in Table 1.
5.6 Water impermeability

When tested in accordance with EN 491:2011, 5.7 the underside of the tiles and/or valley tiles may show

drops of water but no drops shall fall before the completion of the test (20 h).

Fittings, other than valley tiles, are not required to be tested for water impermeability, provided they conform to

5.2.4 and 5.7.2.
5.7 Durability (freeze-thaw resistance)
5.7.1 Tiles

When tested in accordance with EN 491:2011, 5.8, the tiles shall conform to the requirements for

impermeability (see 5.6) and transverse strength (see 5.5).
5.7.2 Fittings

Fittings, other than valley tiles, when tested in accordance with EN 491:2011, 5.8, shall not be broken,

separated into parts or cracked.
5.7.3 Valley tiles

When tested in accordance with EN 491:2011, 5.8, valley tiles shall conform to the requirements for

impermeability (see 5.6).
5.8 Nib support

Tiles with nib(s) shall be tested in accordance with EN 491:2011, 5.9. The tile nib(s) shall support the tile in

the test position so that the tile does not fall.
5.9 Fire performance
5.9.1 External fire performance
5.9.1.1 Requirements

Where subject to regulatory requirements, the external fire performance of the products shall be declared

according to the provisions of 5.9.1.2.
---------------------- Page: 10 ----------------------
SIST EN 490:2012
EN 490:2011 (E)
5.9.1.2 Test and assessment methods

5.9.1.2.1 Products satisfying the requirements for external fire performance, without the need for

testing

Tiles and fittings covered by this European Standard meet the requirements for external fire performance

without the need for testing, provided that they satisfy the definitions given in Commission Decision

2000/553/EC [1], i.e. that:
 they satisfy the provisions of Commission Decision 96/603/EC [2], and

 any external coating shall be inorganic or have a gross calorific potential (PCS) ≤ 4,0 MJ/m or a mass

≤ 200 g/m .

For this purpose the calorific value or mass of the organic coating shall be measured over the exposed area

only.

NOTE Member States may have national ‘deemed to satisfy’ lists, which include more products than those given in

Decision 2000/553/EC.
5.9.1.2.2 Other products

Products not meeting the provisions of 5.9.1.2.1 shall be tested and classified in accordance with EN 13501-5

using the classification(s) relevant for the country of destination of the products. The products to be tested

shall be installed, in addition to the general provisions given in ENV 1187, in a manner representative of their

intended use.
5.9.2 Reaction to fire performance
5.9.2.1 Requirements

This characteristic shall be declared when subject to regulatory requirements, and may be declared when not

subject to such regulatory requirements. The reaction of products to fire shall be determined and declared

according to the provisions of 5.9.2.2.

This characteristic does not apply to glued tiles or fittings. For such products, no indication needs to be given

related to their reaction to fire performance, nor does Class F need to be given.

5.9.2.2 Testing and assessment methods

5.9.2.2.1 Products satisfying the requirements for the fire reaction Class A1, without the need for

testing

Tiles and fittings are classified Class A1 of the characteristic reaction to fire, in accordance with the provisions

of Commission Decision 96/603/EC [2], as amended, without the need for testing, provided that:

 they contain ≤ 1,0 % by weight or volume (whichever is the lower) of homogeneously distributed organic

material (other than glue);

 any coating system (i.e. organic layer and cement slurry layer, if relevant), which contains ≤ 1,0 % by

weight or volume (whichever is the lower) of homogeneously distributed organic material, is itself

Class A1.
5.9.2.2.2 Other products

Products not meeting the requirements of 5.9.2.2.1 shall be tested and classified in accordance with

EN 13501-1 as follows:
---------------------- Page: 11 ----------------------
SIST EN 490:2012
EN 490:2011 (E)

 for a coating system with a gross calorific potential (PCS) ≤ 2,0 MJ/kg, when tested according to

EN ISO 1716, the product may be classified A1;

 for a coating system with a PCS ≤ 2,0 MJ/m², the product may be classified A1 provided that the coating

system, when tested according to EN 13823, meets the requirements for this given in EN 13501-1;

 for a coating system with a PCS > 2,0 MJ/kg and ≤ 4,0 MJ/m , when tested according to EN ISO 1716,

the complete coating system shall be tested according to EN 13823, and mounted on either the calcium

silicate or fibre cement substrates given in EN 13238. If the coating system meets the requirements of

Class A2, the product shall also be classified Class A2 with appropriate smoke and droplets sub-

classification;

 for any coating system other than those stated above, the coating shall be tested for the requirements of

classes lower than A2 and the product shall be given the same class as the coating system;

 as an alternative to the above requirements, the coated product itself shall be tested and the classification

requirements of EN 13501-1 shall apply. For tests to EN 13823, the product shall be mounted and fixed in

a manner which is representative of its intended application (i.e. mounted on timber battens with no

underlying insulation or organic material) in accordance with EN 491.

The requirements above relate to uncoated tiles or fittings which are Class A1. Where the uncoated tiles or

fittings contain > 1,0 % by weight or volume (whichever is the lower) of homogeneously distributed organic

material and are not Class A1, coated products shall be classified in accordance with EN 13501-1.

Results obtained for a coating system including an organic layer, apply to any other coating systems

containing the same composition as the system tested (e.g. the same generic type of polymeric binding) but

having less organic material and, therefore, a PCS which is less than that tested.

The classification obtained from tests of any tile profile or design also applies to tiles of the same body

material and the same composition of organic coating, for:

 any other tile design (i.e. any other tile profile and single lap or double lap tiles), and fittings;

 tiles with a different surface texture (i.e. smooth, patterned or granulated);
 tiles laid with headlap greater than that tested;
 tiles laid in straight or broken bond
 tiles laid with or without mechanical fixings;
 tiles laid on other timber or metal battens, with or without counterbattens;

 tiles used for pitched roofs, wall cladding or wall lining; laid with any or no thermal insulation.

5.10 Release of dangerous substances
For products used within the European Economic Area, see Annex ZA, Note to ZA.1.
6 Evaluation of conformity
6.1 General

The compliance of a concrete roofing tile or fitting with the requirements of this European Standard shall be

demonstrated by:
 initial type testing (ITT), and
---------------------- Page: 12 ----------------------
SIST EN 490:2012
EN 490:2011 (E)
 factory production control (FPC).

For the purpose of testing, tiles and/or fittings may be grouped into families when it is considered that a given

characteristic or characteristics is/are common to all tiles and/or fittings within a family.

6.2 Type testing

Initial type testing shall be performed to demonstrate conformity to this European Standard. All characteristics

given in Table 2 shall, where relevant, be subject to initial type testing.

Tests previously performed to demonstrate conformity to the provisions of this European Standard (same

product, same characteristic(s), same sampling regime, same system of attestation of conformity) may be

taken into account.

In respect of reaction to fire performance, if the raw materials for coating systems are supplied with a

declaration of their PCS values, no testing for PCS is required to demonstrate compliance with the limits given

in 5.9.2.2.2.

Whenever a change occurs in the product design or raw material, or the production process, which would

change significantly one or more of the stated characteristics, the type test shall be repeated for the

appropriate characteristic(s).
6.3 Factory production control (FPC)

The manufacturer shall establish, document and maintain an FPC system to ensure that the products placed

on the market conform to the requirements of this European Standard. The FPC system shall consist of

procedures, regular inspections and tests and/or assessments, to control raw or other materials or

components, equipment, the production process and the product. The FPC system shall be sufficiently

detailed to ensure that the conformity of the product is apparent.

The FPC system shall include the tests identified in the relevant column in Table 2.

The results of inspections, tests, or assessment requiring action and any action taken, shall be recorded. The

action to be taken when control values or criteria are not met shall be recorded.

An FPC system conforming to the requirements of EN ISO 9001, and made specific to the requirements of

this European Standard, is considered to satisfy the requirements for FPC.
7 Sampling
7.1 Sampling for type tests

Tiles and fittings for type tests shall be sampled in accordance with the sampling plan given in Table 2 and the

sampling procedure given in Annex D.

A "day of production" is defined as any period within one 24 h day (or period) of production of roofing tiles or

fittings.
7.2 Sampling for FPC

Tiles and fittings for FPC shall either be sampled in accordance with the sampling plan given in Table 2 or

sample sizes and frequencies shall be determined by the use of statistical process control methods and/or

acceptance sampling such that not less than 95 % of products satisfy the requirements of each production

control test.
---------------------- Page: 13 ----------------------
SIST EN 490:2012
EN 490:2011 (E)
7.3 Compliance

When evaluating products in accordance with this European Standard each test shall be considered

separately.

If one tile or fitting does not meet the requirements then a second sample of 10 tiles or fittings (11 tiles for

cover width) shall be taken. All of the tiles and or fittings in the second sample shall meet the requirements. If

more than one tile or fitting in the first sample fails or if one tile or fitting in the second sample fails then the

products being evaluated shall be deemed not to satisfy the requirements of this European Standard.

Table 2 — Sampling plans
Factory Production Control
Test method Type test
Clause tests
Test (EN 491:2011, Clause
reference Sample Sample Minimum
reference)
size size frequency
Hanging length and 1 per 7 days of
5.2.1 5.2 3 3
squareness production
Coordinated fittings 1 per 7 days of
Dimensions of fittings 5.2.4 3 3
only production
1 per 7 days of
Cover width 5.2.2 5.3 11 11
production
1 per 7 days of
Flatness 5.2.3 5.4 3 3
production
1 per 7 days of
Mass 5.3 5.5 3 3
production
1 per day of
Transverse strength 5.5 5.6 3 3
production
1 per 7 days of
Impermeability 5.6 5.7 3 1
production
Not to be
Freeze/thaw 5.7 5.8 3 -
tested
Not to be
Nib support 5.8 5.9 3 -
tested
EN 13501-1 and/or See the
Not to be a
Fire tests 5.9 EN 13501-5 (where relevant
tested
required) test method

For coated products, the manufacturer shall control the composition and rate of application of the coating system.

---------------------- Page: 14 ----------------------
SIST EN 490:2012
EN 490:2011 (E)
8 Designation system
8.1 Tiles

Where a designation system is used for tiles, the designation shall consist of the following sequence of

individual codes separated by a hyphen (-).
Description Code
Type of product: tile T
Document EN 490
Interlocking or non-interlocking tile IL or NL
Depth d In millimetres
Regular or irregular front edge RF or IF
Cover width c In millimetres
c cover width drawn out value In millimetres, or / if not declared
c cover width closed up value In millimetres, or / if not declared
Hanging length l in millimetres
Mass in kg

Example of designation for an interlocking tile with regular front edge, cover width not declared: T-EN 490-IL-

30-RF-300-/-/-330-4,5
8.2 Fittings

Where a designation system is used for fittings, the designation shall consist of the following sequence of

individual codes separated by a hyphen (-).
Description Code
Type of product: fitting F
Document EN 490
Type of fitting: Ridge R
Valley VA
Hip H
Verge tile VT
Other types In words
Coordinated or non-coordinated CO or NC
Relevant dimensions millimetres × millimetres
Mass kg
In the language or languages acceptable to the country where the fitting
is to be supplied.

Example of designation for a non-coordinated ridge fitting: F-EN 490-R-NC-300×200-5,0

---------------------- Page: 15 ----------------------
SIST EN 490:2012
EN 490:2011 (E)
9 Marking and labelling

Concrete roofing tiles and fittings conforming to this European Standard shall be marked with the name of the

manufacturer or a trademark or other equivalent means of identification.
10 Documents
The following particulars shall be
...

Questions, Comments and Discussion