Concrete roofing tiles and fittings for roof covering and wall cladding - Product specifications

This European Standard specifies requirements for concrete roofing tiles and fittings for pitched roof coverings and wall cladding and lining.
Concrete roofing tiles and fittings may incorporate surface coatings and glued concrete components.
NOTE 1   Information on surface characteristics is given in Annex A.
NOTE 2   Information on the performance of roof and wall assemblies is given in Annex B.

Dach- und Formsteine aus Beton für Dächer und Wandbekleidungen - Produktanforderungen

Diese Europäische Norm legt Anforderungen an Dach- und Formsteine aus Beton für geneigte Dächer sowie für Innen- und Außenwandbekleidungen fest.
Dach- und Formsteine aus Beton können eine Oberflächenbeschichtung aufweisen und aus zusammengeklebten Betonbauteilen bestehen.
ANMERKUNG 1 Anhang A enthält Informationen zur Oberflächenbeschaffenheit.
ANMERKUNG 2 Anhang B enthält Informationen zum Verhalten von Dacheindeckungen und Wandbekleidungen

Tuiles et accessoires en béton pour couverture et bardage - Spécifications des produits

La présente Norme européenne définit les prescriptions relatives aux tuiles et accessoires en béton destinés aux toitures avec pente et aux bardages.
Les tuiles et accessoires en béton peuvent être pourvus de revêtements de surface et de composants en béton assemblés par collage.
NOTE 1   Des informations sur les caractéristiques de surface sont données en Annexe A.
NOTE 2   Des informations sur les performances des assemblages pour toiture et bardage sont données en Annexe B.

Betonski strešniki in fazonski kosi za prekrivanje streh in oblaganje sten - Specifikacije za izdelek

Ta evropski standard določa zahteve za betonske strešnike in fazonske kose za obloge za poševne strehe ter zunanje in notranje stenske obloge.
Betonski strešniki in fazonski kosi lahko vključujejo površinske premaze in lepljene betonske sestavne dele.
OPOMBA 1: Informacije o značilnostih površine semen so podane v dodatku A.
OPOMBA 2: Informacije o lastnostih strešnih in stenskih sestavov so podane v dodatku B.

General Information

Status
Published
Publication Date
13-Mar-2017
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
21-Feb-2017
Due Date
28-Apr-2017
Completion Date
14-Mar-2017

Relations

Buy Standard

Standard
EN 490:2012+A1:2017
English language
31 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 490:2012+A1:2017
01-april-2017
1DGRPHãþD
SIST EN 490:2012
Betonski strešniki in fazonski kosi za prekrivanje streh in oblaganje sten -
Specifikacije za izdelek
Concrete roofing tiles and fittings for roof covering and wall cladding - Product
specifications
Dach- und Formsteine aus Beton für Dächer und Wandbekleidungen -
Produktanforderungen
Tuiles et accessoires en béton pour couverture et bardage - Spécifications des produits
Ta slovenski standard je istoveten z: EN 490:2011+A1:2017
ICS:
91.060.20 Strehe Roofs
91.100.30 Beton in betonski izdelki Concrete and concrete
products
SIST EN 490:2012+A1:2017 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 490:2012+A1:2017

---------------------- Page: 2 ----------------------

SIST EN 490:2012+A1:2017


EN 490:2011+A1
EUROPEAN STANDARD

NORME EUROPÉENNE

January 2017
EUROPÄISCHE NORM
ICS 91.100.30 Supersedes EN 490:2011
English Version

Concrete roofing tiles and fittings for roof covering and
wall cladding - Product specifications
Tuiles et accessoires en béton pour couverture et Dach- und Formsteine aus Beton für Dächer und
bardage - Spécifications des produits Wandbekleidungen - Produktanforderungen
This European Standard was approved by CEN on 18 September 2011 and includes Amendment 1 approved by CEN on 10
November 2015.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.

This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and United Kingdom.





EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2017 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 490:2011+A1:2017 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------

SIST EN 490:2012+A1:2017
EN 490:2011+A1:2017 (E)
Contents
Page
European foreword . 3
1 Scope . 4
2 Normative references . 4
3 Terms and definitions . 4
4 Symbols and abbreviations . 5
5 Requirements . 6
6 !Assessment and verification of constancy of performance (AVCP)" . 10
7 Sampling . 11
8 Designation system . 13
9 Marking and labelling . 14
10 Documents . 14
Annex A (informative) Surface characteristics. 15
Annex B (informative) Performance of assemblies of roofing tiles and fittings . 16
Annex C (normative) Fasteners and fixings . 17
Annex D (normative) Sampling procedure . 18
Annex ZA (informative) Clauses of this European Standard addressing the provisions of the
EU Construction Products Regulation . 19
Bibliography . 31

2

---------------------- Page: 4 ----------------------

SIST EN 490:2012+A1:2017
EN 490:2011+A1:2017 (E)
European foreword
This document (EN 490:2011+A1:2017) has been prepared by Technical Committee CEN/TC 128 “Roof
covering products for discontinuous laying and products for wall cladding”, the secretariat of which is
held by NBN.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by July 2017, and conflicting national standards shall be
withdrawn at the latest by October 2018.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent
rights.
This document includes Amendment 1 approved by CEN on 2015-11-10.
This document supersedes !EN 490:2011".
The start and finish of text introduced or altered by amendment is indicated in the text by tags !".
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association, and supports essential requirements of EU Directive(s).
For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this
document.
!This amendment to Annex ZA of EN 490:2011 implements EU Regulation no. 305/2011."
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria,
Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia,
France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta,
Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.
3

---------------------- Page: 5 ----------------------

SIST EN 490:2012+A1:2017
EN 490:2011+A1:2017 (E)
1 Scope
This European Standard specifies requirements for concrete roofing tiles and fittings for pitched roof
coverings and wall cladding and lining.
Concrete roofing tiles and fittings may incorporate surface coatings and glued concrete components.
NOTE 1 Information on surface characteristics is given in Annex A.
NOTE 2 Information on the performance of roof and wall assemblies is given in Annex B.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
EN 491:2011, Concrete roofing tiles and fittings for roof covering and wall cladding — Test methods
ENV 1187, Test methods for external fire exposure to roofs
EN 13238, Reaction to fire tests for building products — Conditioning procedures and general rules for
selection of substrates
EN 13823, Reaction to fire tests for building products — Building products excluding floorings exposed to
the thermal attack by a single burning item
EN 13501-1, Fire classification of construction products and building elements — Part 1: Classification
using data from reaction to fire tests
EN 13501-5, Fire classification of construction products and building elements — Part 5: Classification
using data from external fire exposure to roof tests
EN ISO 1716, Reaction to fire tests for products — Determination of the gross heat of combustion (calorific
value) (ISO 1716:2010)
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
aggregate
concrete component consisting of uncrushed and/or crushed natural and/or artificial mineral
substances with particle sizes and shapes suitable for the production of concrete
3.2
additive
finely divided material that may be added to concrete in order to improve certain properties or to
achieve special properties
3.3
pigment
additive intended to add colour to the concrete
4

---------------------- Page: 6 ----------------------

SIST EN 490:2012+A1:2017
EN 490:2011+A1:2017 (E)
3.4
admixture
material which is added in small quantities relative to the mass of the cement before or during mixing
or during an additional mixing operation, causing required modifications to the properties
3.5
cement
hydraulic binder, i.e. finely ground inorganic material, which, when mixed with water, forms a paste
which sets by means of hydration reactions and processes and which, after hardening, retains its
strength and stability
3.6
fitting
component, of concrete, that is complementary to the tiles and has a special function
NOTE Fittings may contain inserts of other materials.
3.6.1
coordinated fitting
fitting that is intended to align or interlock with the tiles with which it is to be laid (e.g. interlocking
verge tile, interlocking ventilation tile, tile-and-a-half, aligning valley tile, interlocking or aligning angle
tiles)
3.7
valley tile
fitting for use at a meeting of two roof pitches forming a re-entrant angle
3.8
interlocking tile
profiled or flat tile which has a side lock, with or without a head lock feature
3.9
non-interlocking tile
profiled or flat tile without interlocks
3.10
tile with a regular front edge
tile (interlocking or non-interlocking) which, by design, has a constant or regularly varying hanging
length across the width
3.11
tile with an irregular front edge
tile (interlocking or non-interlocking), which, by design, has an irregular varying hanging length across
the width
!
3.12
product type
set of representative performance levels or classes of a construction product, in relation to its essential
characteristics, produced using a given combination of raw materials or other elements in a specific
production process"
5

---------------------- Page: 7 ----------------------

SIST EN 490:2012+A1:2017
EN 490:2011+A1:2017 (E)
4 Symbols and abbreviations
For the purposes of this document, the following symbols and abbreviations apply.
l hanging length of a tile
1
l , l hanging edge length of a tile, as defined in EN 491:2011, Clause 4
2 3
c cover width of one tile
w
c cover width closed up value of 10 tiles
wc
c cover width drawn out value of 10 tiles
wd
d profile depth of a tile
F minimum transverse strength of all tiles
min
F transverse strength of an individual tile
i
IL interlocking
NL non-interlocking
RF regular front edge
IF irregular front edge
/ not applicable or not declared characteristic for designation system
5 Requirements
5.1 Materials
The concrete used in the manufacture of tiles and fittings shall be formed by mixing cement, aggregate
and water and produced by the hardening of the cement paste (cement and water).
NOTE In addition to the basic components, the concrete may also contain pigments, admixtures and/or
additives.
5.2 Dimensions
5.2.1 Hanging length and squareness
The tile hanging length shall be declared in the manufacturer’s technical specification. For tiles with a
regular front edge, the values of l shall be ± 4 mm of the manufacturer’s declared value when tested in
1
accordance with EN 491:2011, 5.2.
The squareness for tiles with nominally constant hanging length, when tested in accordance with
EN 491:2011, 5.2.2.1, shall be calculated as the difference between values l and l and shall be not
2 3
greater than 4 mm.
This sub-clause does not apply for tiles that are designed, for example for aesthetic reasons, with an
irregular front edge.
5.2.2 Cover width
5.2.2.1 General
The tile cover width c shall be declared in the manufacturer’s technical specification.
w
NOTE The cover width shunts may also be declared in the manufacturer’s technical specification.
This sub-clause does not apply for tiles that are designed, for example for aesthetic reasons, with a
randomly varying cover width.
6

---------------------- Page: 8 ----------------------

SIST EN 490:2012+A1:2017
EN 490:2011+A1:2017 (E)
5.2.2.2 Interlocking tiles
When tiles with cover width shunts declared by the manufacturer are tested in accordance with
EN 491:2011, 5.3.3.1, the cover width shall conform to the following:
— cwd/10 ≥ cw + declared “plus cover width shunt”;
— c /10 ≤ c - declared “minus cover width shunt”.
wc w
When tiles without cover width shunts, and tiles with cover width shunt but not declared by the
manufacturer, are tested in accordance with EN 491:2011, 5.3.3.1, the mean cover width shall be ± 5
mm of the manufacturer’s declared cover width.
5.2.2.3 Non-interlocking tiles
When non-interlocking tiles are tested in accordance with EN 491:2011, 5.3.3.2, the mean cover width
shall be ± 3 mm of the manufacturer’s declared value.
5.2.3 Flatness
When tiles are tested in accordance with EN 491:2011, 5.4, the gap between any designed contact point
and the flat surface shall not exceed 3 mm or c /100 mm to the nearest millimetre, whichever is the
w
greater.
This sub-clause does not apply where the manufacturer declares that:
— tiles are designed to have less than four contact points to a flat surface, and/or
— tiles are designed to be irregular in flatness.
5.2.4 Fittings
The manufacturer shall identify and declare the dimensions and tolerances and method of
measurement of the fitting relevant to its use. Where relevant, the tile element of a coordinated fitting
shall conform to 5.2.1, 5.2.2 and 5.2.3.
5.3 Mass
The mass of tiles and fittings shall be declared in the manufacturer’s technical specification.
When tiles are tested in accordance with EN 491:2011, 5.5, the mean mass shall be:
a) manufacturer’s declared mass ± 0,2 kg for tiles with a declared mass not greater than 2 kg;
b) manufacturer’s declared mass ± 10 % for tiles with a declared mass greater than 2 kg.
5.4 Fixing holes (where provided)
Fixing holes, where provided, shall be arranged so that an intended connection between the tiles and/or
fittings and the batten can be achieved.
NOTE Information on fasteners and fixings is given in Annex C. Details of the size and position of the fixing
holes may be given in the manufacturer’s technical and/or commercial literature.
5.5 Mechanical resistance (transverse strength)
When tiles are tested in accordance with EN 491:2011, 5.6:
a) value of F shall be not less than the appropriate value given in Table 1, or
min
7

---------------------- Page: 9 ----------------------

SIST EN 490:2012+A1:2017
EN 490:2011+A1:2017 (E)
b) number of individual tiles with transverse strength values (F ) less than the appropriate value in
i
Table 1, shall be not more than the appropriate acceptance value in 7.3.
Tiles tested prior to 28 days after manufacture shall be deemed to conform if they reach at least 80 % of
the values specified in Table 1 and the manufacturer can demonstrate statistically that the values given
in Table 1 are achieved at 28 days.
Fittings shall conform to 5.2.4 and 5.7.2 (and 5.7.3 in the case of valley tiles).
Table 1 — Minimum transverse strength F of tiles
min
Non-interlocking
Interlocking tiles
tiles
Property
Profiled Flat
Profile depth d > 20mm 20 mm ≥ d ≥ 5 mm d < 5mm
c (mm) ≥ 300 ≤ 200 ≥ 300 ≤ 200 ≥ 300 ≤ 200
w
F (N) 2 000 1 400 1 400 1 000 1 200 800 550
min
The profile depth (d) shall be declared by the manufacturer and, if d < 20 mm, shall be measured in
accordance with EN 491:2011, 5.6.4.1.
For interlocking tiles between 200 mm and 300 mm cover width, the minimum transverse strength
shall be determined by linear interpolation between the values given in Table 1.
5.6 Water impermeability
When tested in accordance with EN 491:2011, 5.7 the underside of the tiles and/or valley tiles may
show drops of water but no drops shall fall before the completion of the test (20 h).
Fittings, other than valley tiles, are not required to be tested for water impermeability, provided they
conform to 5.2.4 and 5.7.2.
5.7 Durability (freeze-thaw resistance)
5.7.1 Tiles
When tested in accordance with EN 491:2011, 5.8, the tiles shall conform to the requirements for
impermeability (see 5.6) and transverse strength (see 5.5).
5.7.2 Fittings
Fittings, other than valley tiles, when tested in accordance with EN 491:2011, 5.8, shall not be broken,
separated into parts or cracked.
5.7.3 Valley tiles
When tested in accordance with EN 491:2011, 5.8, valley tiles shall conform to the requirements for
impermeability (see 5.6).
5.8 Nib support
Tiles with nib(s) shall be tested in accordance with EN 491:2011, 5.9. The tile nib(s) shall support the
tile in the test position so that the tile does not fall.
8

---------------------- Page: 10 ----------------------

SIST EN 490:2012+A1:2017
EN 490:2011+A1:2017 (E)
5.9 Fire performance
5.9.1 External fire performance
5.9.1.1 Requirements
Where subject to regulatory requirements, the external fire performance of the products shall be
declared according to the provisions of 5.9.1.2.
5.9.1.2 Test and assessment methods
5.9.1.2.1 Products satisfying the requirements for external fire performance, without the need
for testing
Tiles and fittings covered by this European Standard meet the requirements for external fire
performance without the need for testing, provided that they satisfy the definitions given in
Commission Decision 2000/553/EC [1], i.e. that:
— they satisfy the provisions of Commission Decision 96/603/EC [2], and
2
— any external coating shall be inorganic or have a gross calorific potential (PCS) ≤ 4,0 MJ/m or a
2
mass ≤ 200 g/m .
For this purpose the calorific value or mass of the organic coating shall be measured over the exposed
area only.
NOTE Member States may have national ‘deemed to satisfy’ lists, which include more products than those
given in Decision 2000/553/EC.
5.9.1.2.2 Other products
Products not meeting the provisions of 5.9.1.2.1 shall be tested and classified in accordance with
EN 13501-5 using the classification(s) relevant for the country of destination of the products. The
products to be tested shall be installed, in addition to the general provisions given in ENV 1187, in a
manner representative of their intended use.
5.9.2 Reaction to fire performance
5.9.2.1 Requirements
This characteristic shall be declared when subject to regulatory requirements, and may be declared
when not subject to such regulatory requirements. The reaction of products to fire shall be determined
and declared according to the provisions of 5.9.2.2.
This characteristic does not apply to glued tiles or fittings. For such products, no indication needs to be
given related to their reaction to fire performance, nor does Class F need to be given.
5.9.2.2 Testing and assessment methods
5.9.2.2.1 Products satisfying the requirements for the fire reaction Class A1, without the need for
testing
Tiles and fittings are classified Class A1 of the characteristic reaction to fire, in accordance with the
provisions of Commission Decision 96/603/EC [2], as amended, without the need for testing, provided
that:
— they contain ≤ 1,0 % by weight or volume (whichever is the lower) of homogeneously distributed
organic material (other than glue);
9

---------------------- Page: 11 ----------------------

SIST EN 490:2012+A1:2017
EN 490:2011+A1:2017 (E)
— any coating system (i.e. organic layer and cement slurry layer, if relevant), which contains ≤ 1,0 %
by weight or volume (whichever is the lower) of homogeneously distributed organic material, is
itself Class A1.
5.9.2.2.2 Other products
Products not meeting the requirements of 5.9.2.2.1 shall be tested and classified in accordance with
EN 13501-1 as follows:
— for a coating system with a gross calorific potential (PCS) ≤ 2,0 MJ/kg, when tested according to
EN ISO 1716, the product may be classified A1;
— for a coating system with a PCS ≤ 2,0 MJ/m², the product may be classified A1 provided that the
coating system, when tested according to EN 13823, meets the requirements for this given in
EN 13501-1;
2
— for a coating system with a PCS > 2,0 MJ/kg and ≤ 4,0 MJ/m , when tested according to EN
ISO 1716, the complete coating system shall be tested according to EN 13823, and mounted on
either the calcium silicate or fibre cement substrates given in EN 13238. If the coating system meets
the requirements of Class A2, the product shall also be classified Class A2 with appropriate smoke
and droplets sub-classification;
— for any coating system other than those stated above, the coating shall be tested for the
requirements of classes lower than A2 and the product shall be given the same class as the coating
system;
— as an alternative to the above requirements, the coated product itself shall be tested and the
classification requirements of EN 13501-1 shall apply. For tests to EN 13823, the product shall be
mounted and fixed in a manner which is representative of its intended application (i.e. mounted on
timber battens with no underlying insulation or organic material) in accordance with EN 491.
The requirements above relate to uncoated tiles or fittings which are Class A1. Where the uncoated tiles
or fittings contain > 1,0 % by weight or volume (whichever is the lower) of homogeneously distributed
organic material and are not Class A1, coated products shall be classified in accordance with EN 13501-
1.
Results obtained for a coating system including an organic layer, apply to any other coating systems
containing the same composition as the system tested (e.g. the same generic type of polymeric binding)
but having less organic material and, therefore, a PCS which is less than that tested.
The classification obtained from tests of any tile profile or design also applies to tiles of the same body
material and the same composition of organic coating, for:
— any other tile design (i.e. any other tile profile and single lap or double lap tiles), and fittings;
— tiles with a different surface texture (i.e. smooth, patterned or granulated);
— tiles laid with headlap greater than that tested;
— tiles laid in straight or broken bond
— tiles laid with or without mechanical fixings;
— tiles laid on other timber or metal battens, with or without counterbattens;
— tiles used for pitched roofs, wall cladding or wall lining; laid with any or no thermal insulation.
10

---------------------- Page: 12 ----------------------

SIST EN 490:2012+A1:2017
EN 490:2011+A1:2017 (E)
5.10 Release of dangerous substances
For products used within the European Economic Area, see Annex ZA, Note to ZA.1.
6 !Assessment and verification of constancy of performance (AVCP)"
6.1 General
The compliance of a concrete roofing tile or fitting with the requirements of this European Standard
!and with the performances declared by the manufacturer in the declaration of performance
(DoP)" shall be demonstrated by:
— !determination of the product type by" initial type testing (ITT), and
— factory production control (FPC).
For the purpose of testing, tiles and/or fittings may be grouped into families when it is considered that a
given characteristic or characteristics is/are common to all tiles and/or fittings within a family.
6.2 Type testing
Initial type testing shall be performed to demonstrate conformity to this European Standard. All
characteristics given in Table 2 shall, where relevant, be subject to initial type testing.
Tests previously performed to demonstrate conformity to the provisions of this European Standard
(same product, same characteristic(s), same sampling regime, same system of attestation of conformity)
may be taken into account.
In respect of reaction to fire performance, if the raw materials for coating systems are supplied with a
declaration of their PCS values !demonstrating their compliance", no testing for PCS is required to
demonstrate compliance with the limits given in 5.9.2.2.2.
Whenever a change occurs in the product design or raw material, or the production process, which
would change significantly one or more of the stated characteristics, the type test shall be repeated for
the appropriate characteristic(s).
!A manufacturer may use the results of the product type determination obtained by someone else
(e.g. by another manufacturer, as a common service to manufacturers, or by a product developer), to
justify his own declaration of performance regarding a product that is manufactured according to the
same design (e.g. dimensions) and with raw materials, constituents and manufacturing methods of the
same kind."
6.3 Factory production control (FPC)
The manufacturer shall establish, document and maintain an FPC system to ensure that the products
placed on the market conform to the requirements of this European Standard. The FPC system shall
consist of procedures, regular inspections and tests and/or assessments, to control raw or other
materials or components, equipment, the production process and the product. The FPC system shall be
sufficiently detailed to ensure that the conformity of the product is apparent.
The FPC system shall include the tests identified in the relevant column in Table 2 !, if they apply to
the product".
The results of inspections, tests, or assessment requiring action and any action taken, shall be recorded.
The action to be taken when control values or criteria are not met shall be recorded.
An FPC system conforming to the requirements of EN ISO 9001, and made specific to the requirements
of this European Standard, is considered to satisfy the requirements for FPC.
11

---------------------- Page: 13 ----------------------

SIST EN 490:2012+A1:2017
EN 490:2011+A1:2017 (E)
7 Sampling
7.1 Sampling for type tests
Tiles and fittings for type tests shall be sampled in accordance with the sampling plan given in Table 2
and the sampling procedure given in Annex D.
A "day of production" is defined as any period within one 24 h day (or period) of production of roofing
tiles or fittings.
7.2 Sampling for FPC
Tiles and fittings for FPC shall either be sampled in accordance with the sampling plan given in Table 2
or sample sizes and frequencies shall be determined by the use of statistical process control methods
and/or acceptance sampling such that not less than 95 % of products satisfy the requirements of each
production control test.
7.3 Compliance
When evaluating products in accordance with this European Standard each test shall be considered
separately.
If one tile or fitting does not meet the requirements then a second sample of 10 tiles or fittings (11 tiles
for cover width) shall be taken. All of the tiles and or fittings in the second sample shall meet the
requirements. If more than one tile or fitting in the first sample fails or if one tile or fitting in the second
sample fails then the products being evaluated shall be deemed not to satisfy the requirements of this
European Standard.
12

---------------------- Page: 14 ----------------------

SIST EN 490:2012+A1:2017
EN 490:2011+A1:2017 (E)
Table 2 — Sampling plans
Factory Production Control
Type test
Test method
tests
Clause
Test (EN 491:2011, Clause
reference
Sample Sample Minimum
reference)
size size frequency
Hanging length and 1 per 7 days of
5.2.1 5.2 3 3
squareness production
Coordinated fittings 1 per 7 days of
Dimensions of fittings 5.2.4 3 3
only production
1 per 7 days of
Cover width 5.2.2 5.3 11 11
production
1 per 7 days of
Flatness 5.2.3 5.4 3 3
production
1 per 7 days of
Mass 5.3 5.5 3 3
production
1 per day of
Transverse strength 5.5 5.6 3 3
production
1 per 7 days of
Impermeability 5.6 5.7 3 1
production
Not to be
Freeze/thaw 5.7 5.8 3 -
tested
Not to be
Nib support 5.8 5.9 3 -
tested
EN 13501-1 and/or See the
Not to be
a
Fire tests 5.9 EN 13501-5 (where relevant
tested
required) test method
a
For coated products, the manufacturer shall control the composition and rate of application of the coating system.
8 Designation system
8.1 Tiles
Where a designation system is used for tiles, the designation shall consist of t
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.