EN 14654-2:2013
(Main)Management and control of operational activities in drain and sewer systems outside buildings - Part 2: Rehabilitation
Management and control of operational activities in drain and sewer systems outside buildings - Part 2: Rehabilitation
This European Standard establishes the general principles for the management and control of operational activities in drain and sewer systems outside buildings and specifies requirements for development and implementation of work programmes, and the selection of techniques.
This part covers the management and control of rehabilitation activities.
It is applicable to drain and sewer systems, which operate essentially under gravity, from the point where wastewater leaves a building, roof drainage system, or paved area, to the point where it is discharged into a treatment works or receiving water. Drains and sewers below buildings are included provided that they do not form part of the drainage system of the building.
Management und Überwachung von betrieblichen Maßnahmen in Abwasserleitungen und -kanälen - Teil 2: Sanierung
Diese Europäische Norm stellt die allgemeinen Verfahren zu Management und Überwachung von betrieblichen Maßnahmen in Entwässerungssystemen außerhalb von Gebäuden auf und legt Anforderungen an die Entwicklung und Umsetzung von Arbeitsprogrammen und die Auswahl von Techniken fest.
Dieser Teil behandelt das Management und die Überwachung von Sanierungsmaßnahmen.
Er gilt für Entwässerungssysteme außerhalb von Gebäuden, die hauptsächlich als Freispiegelleitungen betrieben werden, und zwar ab der Stelle, an der das Abwasser ein Gebäude, eine Dachentwässerung oder eine befestigte Fläche verlässt, bis zu dem Punkt, an dem es in eine Behandlungsanlage oder einen Vorfluter eingeleitet wird. Abwasserleitungen und –kanäle unterhalb von Gebäuden sind hierbei eingeschlossen, solange sie nicht Bestandteil der Gebäudeentwässerung sind.
Gestion et contrôle des opérations d'exploitation dans les réseaux d'évacuation et d'assainissement à l'extérieur des bâtiments - Partie 2: Réhabilitation
La présente Norme européenne établit les principes généraux relatifs à la gestion et au contrôle des opérations d’exploitation dans les réseaux d’évacuation et d’assainissement à l’extérieur des bâtiments et spécifie les exigences relatives au développement et à la mise en oeuvre de programmes de travail, ainsi qu’au choix des techniques.
La présente partie traite de la gestion et du contrôle des activités de réhabilitation.
Elle est applicable aux réseaux d’évacuation et d’assainissement, principalement les réseaux gravitaires, à partir du point où les eaux usées quittent un bâtiment, un système d’évacuation de toiture ou une surface revêtue, jusqu’au point où elles se déversent dans une station d’épuration ou dans un milieu récepteur aquatique. Les branchements et collecteurs situés sous les bâtiments sont inclus à condition qu’ils ne fassent pas partie du réseau d’évacuation du bâtiment.
Upravljanje in nadzor nad čiščenjem odvodnih in odpadnih kanalov - 2. del: Sanacija
Ta evropski standard določa splošna načela za upravljanje in nadzor nad operativnimi dejavnostmi v odvodnih in odpadnih kanalih zunaj stavb ter določa zahteve za razvoj in izvajanje delovnih programov ter izbiro tehničnih pristopov. Ta del zajema upravljanje in nadzor sanacijskih del. Velja za drenažne in kanalizacijske sisteme, ki delujejo zlasti s pomočjo gravitacije, od točke, kjer odpadne vode zapustijo stavbo, strešni drenažni sistem ali tlakovano območje, do točke, kjer se izlivajo v čistilne naprave ali sprejemajoče vodno telo. Zajeti so tudi drenažni in kanalizacijski sistemi, ki ne tvorijo dela drenažnega sistema stavbe.
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.6DQDFLMDManagement und Überwachung von betrieblichen Maßnahmen in Abwasserleitungen und -kanälen - Teil 2: SanierungGestion et contrôle des opérations de nettoyage des canalisations d'évacuation et d'assainissement - Partie 2: RéhabilitationManagement and control of cleaning operations in drains and sewers - Part 2: Rehabilitation93.030Zunanji sistemi za odpadno vodoExternal sewage systemsICS:Ta slovenski standard je istoveten z:EN 14654-2:2013SIST EN 14654-2:2013en,fr,de01-december-2013SIST EN 14654-2:2013SLOVENSKI
STANDARD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 14654-2
January 2013 ICS 93.030 English Version
Management and control of operational activities in drain and sewer systems outside buildings - Part 2: Rehabilitation
Gestion et contrôle des opérations de nettoyage des canalisations d'évacuation et d'assainissement - Partie 2: Réhabilitation
Management und Überwachung von betrieblichen Maßnahmen in Abwasserleitungen und -kanälen - Teil 2: Sanierung This European Standard was approved by CEN on 17 November 2012.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 14654-2:2013: ESIST EN 14654-2:2013
Rehabilitation approaches. 29A.1 Introduction . 29A.2 Rehabilitation planning objectives . 29A.2.1 Introduction . 29A.2.2 Technical objectives . 29A.2.3 Economic objectives . 30A.2.4 Legal objectives . 30A.3 Description of rehabilitation approaches . 30Bibliography . 32 SIST EN 14654-2:2013
This part covers the management and control of rehabilitation activities. It is applicable to drain and sewer systems, which operate essentially under gravity, from the point where wastewater leaves a building, roof drainage system, or paved area, to the point where it is discharged into a treatment works or receiving water. Drains and sewers below buildings are included provided that they do not form part of the drainage system of the building.
2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 752:2008, Drain and sewer systems outside buildings EN 13508-1:2012, Investigation and assessment of drain and sewer systems outside buildings — Part 1: General requirements 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 extraneous water unwanted flow in a drain or
...