Thermal insulation products - Product category rules (PCR) for factory made and in-situ formed products for preparing environmental product declarations

This European Standard provides the product category rules (PCR) for Type III environmental declarations (according to EN 15804) for factory made and in situ thermal insulation products.
In addition to EN 15804, the PCR described in this European Standard:
-   specifies the declared unit to be used;
-   defines the default system boundaries for thermal insulation products;
-   specifies/describes the default scenarios and rules for defining scenarios for each of the life cycle information modules A-D.  (provides guidance for the determination of the reference service life (RSL) for thermal insulation products) ;
-   specifies the way of declaring and reporting in the context of the product Standard.
This PCR is intended to be used for cradle to gate, cradle to gate with options or cradle to grave assessment, provided the intention is properly stated in the system boundary description.

Wärmedämmstoffe - Produktkategorieregeln (PCR) für werkmäßig hergestellte und an der Verwendungsstelle hergestellte Wärmedämmstoffe zur Erstellung von Umweltproduktdeklarationen

Diese Europäische Norm stellt Produktkategorieregeln (PCR, en: product category rules) für Umweltdeklarationen des Typs III (nach EN 15804) bei werkmäßig hergestellten Wärmedämmstoffen und Ortdämmstoffen bereit.
Ergänzend zu EN 15804 leisten die in dieser Europäischen Norm ausgeführten PCR Folgendes:
   sie legen die zu verwendende deklarierte Einheit fest;
   sie bestimmen die Systemgrenzen für Wärmedämmstoffe;
   Standardszenarien und Regeln zur Festlegung von Szenarien für bestimmte Lebenszyklus-Informationsmodule werden bestimmt und beschrieben.
Diese PCR sind unter der Voraussetzung, dass der Zweck innerhalb der Beschreibung der Systemgrenzen exakt angegeben ist, dafür vorgesehen, für die Bewertungen „von der Wiege bis zum Werktor“, „von der Wiege bis zum Werktor mit Optionen“ und „von der Wiege bis zur Bahre“ verwendet zu werden.

Produits isolants thermiques - Règles régissant les catégories de produits (RCP) pour les produits manufacturés et formés en place, destinées à la préparation des déclarations environnementales des produits

La présente Norme européenne fournit les règles régissant les catégories de produits (RCP) pour les déclarations environnementales de Type III (comme dans l’EN 15804) des produits isolants thermiques manufacturés et formés en place.
En complément de l’EN 15804, les RCP décrites dans la présente Norme européenne :
-   spécifient l’unité déclarée à utiliser ;
-   définissent les frontières du système pour les produits isolants thermiques ;
-   spécifient/décrivent les scénarios par défaut et les règles relatives à l’élaboration de scénarios pour certaines modules d’informations du cycle de vie.
Ces RCP sont destinées à être utilisées pour l’évaluation allant du berceau à la sortie de l’usine, du berceau à la sortie de l’usine avec options ou du berceau à la tombe, à condition que l’intention soit dûment mentionnée dans la description des frontières du système.

Toplotnoizolacijski proizvodi - Pravila za kategorije proizvodov za proizvode, izdelane v obratu in na mestu vgradnje, za pripravo okoljskih deklaracij za proizvode

Ta evropski standard zagotavlja pravila za kategorije proizvodov (PCR) za okoljske deklaracije tipa III (v skladu s standardom EN 15804) za toplotnoizolacijske proizvode, izdelane v obratu in na mestu vgradnje.
Poleg standarda EN 15804 pravila za kategorije proizvodov, opisane v tem evropskem standardu:
– določajo navedeno enoto, ki naj bi se uporabljala;
– opredeljujejo privzete sistemske meje za toplotnoizolacijske proizvode;
– določajo/opisujejo privzete scenarije in pravila za opredelitev scenarijev za vsak informacijski modul življenjske dobe A–D (zagotavljajo navodila za določevanje referenčne življenjske dobe (RSL) za toplotnoizolacijske proizvode);
– določajo način označevanja in poročanja v okviru standarda za proizvod.
Ta pravila za kategorije proizvodov se uporabljajo za ocenjevanje faze izdelave »od zibelke do vrat«, »od zibelke do vrat z možnostmi« ali »od zibelke do groba«, če je namera jasno navedena v opisu meja sistema.

General Information

Status
Published
Public Enquiry End Date
30-Dec-2014
Publication Date
18-May-2017
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
20-Apr-2017
Due Date
25-Jun-2017
Completion Date
19-May-2017

Relations

Buy Standard

Standard
EN 16783:2017
English language
18 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Toplotnoizolacijski proizvodi - Pravila za kategorije proizvodov za proizvode, izdelane v obratu in na mestu vgradnje, za pripravo okoljskih deklaracij za proizvodeWärmedämmstoffe - Produktkategorieregeln (PCR) für werkmäßig hergestellte und an der Verwendungsstelle hergestellte Wärmedämmstoffe zur Erstellung von UmweltproduktdeklarationenProduits isolants thermiques - Règles régissant les catégories de produits (RCP) pour les produits manufacturés et formés en place, destinées à la préparation des déclarations environnementales des produitsThermal insulation products - Product category rules (PCR) for factory made and in-situ formed products for preparing environmental product declarations91.120.10Toplotna izolacija stavbThermal insulation of buildingsICS:Ta slovenski standard je istoveten z:EN 16783:2017SIST EN 16783:2017en,fr,de01-junij-2017SIST EN 16783:2017SLOVENSKI
STANDARD



SIST EN 16783:2017



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 16783
April
t r s y ICS
{ sä s t rä s r English Version
Thermal insulation products æ Product category rules næsitu formed products for preparing environmental product declarations Produits isolants thermiques æ Règles régissant les manufacturés et formés en placeá destinées à la préparation des déclarations environnementales des produits werkmäßig hergestellte und an der Verwendungsstelle hergestellte Wärmedämmstoffe zur Erstellung von Umweltproduktdeklarationen This European Standard was approved by CEN on
s x January
t r s yä
egulations which stipulate the conditions for giving this European Standard the status of a national standard without any alterationä Upætoædate lists and bibliographical references concerning such national standards may be obtained on application to the CENæCENELEC Management Centre or to any CEN memberä
translation under the responsibility of a CEN member into its own language and notified to the CENæCENELEC Management Centre has the same status as the official versionsä
CEN members are the national standards bodies of Austriaá Belgiumá Bulgariaá Croatiaá Cyprusá Czech Republicá Denmarká Estoniaá Finlandá Former Yugoslav Republic of Macedoniaá Franceá Germanyá Greeceá Hungaryá Icelandá Irelandá Italyá Latviaá Lithuaniaá Luxembourgá Maltaá Netherlandsá Norwayá Polandá Portugalá Romaniaá Serbiaá Slovakiaá Sloveniaá Spainá Swedená Switzerlandá Turkey and United Kingdomä
EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels
9
t r s y CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Membersä Refä Noä EN
s x y z uã t r s y ESIST EN 16783:2017



EN 16783:2017 (E) 2 Contents Page European foreword . 3 Introduction . 4 1 Scope . 5 2 Normative references . 5 3 Terms and definitions . 5 4 Symbols and abbreviations . 5 5 General aspects . 6 5.1 Objective of the
complementary PCR for insulation products . 6 5.2 Types of EPD with respect to life cycle stages covered . 6 5.3 Comparability of EPD for construction products . 8 5.4 Additional information . 8 5.5 Ownership, responsibility and liability for the EPD . 8 5.6 Communication formats . 8 6 Product Category Rules for LCA . 9 6.1 Product category . 9 6.2 Life cycle stages and their information modules to be included . 9 6.3 Calculation rules for the LCA . 9 6.3.1 Functional unit . 9 6.3.2 Declared unit . 9 6.3.3 Reference service life (RSL). 9 6.3.4 System boundaries . 10 6.3.5 Criteria for the exclusion of inputs and outputs . 11 6.3.6 Selection of data . 11 6.3.7 Data quality requirements. 11 6.3.8 Developing product level scenarios . 11 6.3.9 Units . 11 6.4 Inventory analysis . 11 6.5 Impact assessment . 11 7 Content of the EPD . 12 8 Project report . 12 9 Verification and validity of an EPD . 12 Annex A (normative)
Applications for thermal insulation . 13 Bibliography . 16
SIST EN 16783:2017



EN 16783:2017 (E) 3 European foreword This document (EN 16783:2017) has been prepared by Technical Committee CEN/TC 88 “Thermal insulating materials and products”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by October 2017, and conflicting national standards shall be withdrawn at the latest by October 2017. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN shall not be held responsible for identifying any or all such patent rights. According to the CEN-CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. SIST EN 16783:2017



EN 16783:2017 (E) 4 Introduction This European Standard provides rules for the assessment and quantification of parameters describing the environmental impact of thermal insulation products to prepare environmental product declarations. It defines complementary product category rules for thermal insulation products based on the core rules for all construction products established in EN 15804. These rules are intended to be used in conjunction with EN 15804. These PCR apply to all CEN/TC 88 thermal insulation product Standards (EN 13162 to EN 13171, EN 14063-1, EN 14064-1,
EN 14303 to EN 14309, EN 14313, EN 14314, EN 14315-1 to EN 14320, EN 14933, EN 14934, prEN 15100-1, EN 15101-1, EN 15501, EN 15599-1, EN 15600-1, EN 15732, EN 16069) in order to minimize intra-sectoral deviations. These PCR are also valid for thermal insulation products outside of CEN/TC88 and for thermal insulation products involved in other CEN TCs. As in EN 15804, the results from the assessment are expressed following the modularity principle in a form that allows aggregation (addition) to provide complete information for construction works. These PCR do not deal with aggregation at the construction works level nor does it describe the rules for applying the environmental parameters in a construction works assessment. The reduction in energy used and the reduction of emissions produced during the installed life of insulation products exceed by far the energy used and in most cases the emissions occurring during the production, installation and disposal processes. Clause 5.4 of this European Standard provides the rules for declaration of any such benefits as additional information. NOTE The titles of the clauses in this European Standard follow the EN 15804 to enhance readability. SIST EN 16783:2017



EN 16783:2017 (E) 5 1 Scope This European Standard provides the product category rules (PCR) for Type III environmental declarations (as in EN 15804) for factory made and in situ thermal insulation products. Complementary to EN 15804, the PCR described in this European Standard: — specify the declared unit to be used; — define the system boundaries for thermal insulation products; — specify/describe the default scenarios and rules for defining scenarios for certain life cycle information modules. These PCR are intended to be used for cradle to gate, cradle to gate with options or cradle to grave assessment, provided the intention is properly stated in the system boundary description. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 13172, Thermal insulation products - Evaluation of conformity EN 15804:2012+A1:2013, Sustainability of construction works - Environmental product declarations - Core rules for the product category of construction products EN 15942, Sustainability of construction works - Environmental product declarations - Communication format business-to-business EN 15978, Sustainability of construction works - Assessment of environmental performance of buildings - Calculation method EN ISO 9229, Thermal insulation - Vocabulary (ISO 9229) 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN ISO 9229, EN 15804:2012+A1:2013 and the following apply. 3.1 biogenic carbon carbon derived from/contained in biomass 3.2 biomass material of biological origin excluding material embedded in geological formations and material transformed to fossilised material 4 Symbols and abbreviations For the purpose of this document, the abbreviations given in EN ISO 9229 and EN 15804 and the abbreviations given in Annex A apply. SIST EN 16783:2017



EN 16783:2017 (E) 6 5 General aspects 5.1 Objective of the
complementary PCR for insulation products As in EN 15804 and the Scope of this European Standard. 5.2 Types of EPD with respect to life cycle stages covered These PCR identify three main families of EPD: 1) EPD for factory made insulation products; 2) EPD for products intended to be used as in situ insulation products excluding installation; 3) EPD for products to be used as in situ insulation products including installation. To be in compliance with this European Standard, the declaration of the product stage modules A1-A3 is required as a minimum for those thermal insulation products that have their applicable technical characteristics (e.g. thermal resistance) at the factory gate. In addition, for in situ formed thermal insulation products that establish their applicable technical characteristics after activities on site, the declaration of Module A5 “installation” of the construction process stage is also required. The declaration of the modules of the other life cycle stages is optional. For each of these EPD, mandatory and voluntary stages to be covered are described as in Figure 1. SIST EN 16783:2017



EN 16783:2017 (E) 7
Key m mandatory o optional i mandatory provision of scenario description and technical information Figure 1 — Modules 1) EPD for factory made thermal insulation products: — a cradle to gate EPD: modules A1, A2 and A3 mandatory; — a cradle to gate EPD with options: modules A1, A2 and A3 mandatory, the other modules optional (i.e. cradle to gate and selected further life cycle stages) ; — a cradle to grave EPD: modules A to C mandatory SIST EN 16783:2017



EN 16783:2017 (E) 8 2) EPD for products intended to be used as in situ thermal insulation excluding installation: — a cradle to gate EPD: modules A1, A2 and A3 mandatory and a mandatory description of a scenario for module A5 including the necessary activities to obtain the final insulation product out of the product; — a cradle to gate EPD with options: modules A1, A2 and A3 mandatory, a mandatory description of a scenario for module A5 including the necessary activities to obtain the final insulation product out of the product. The other modules optional (i.e. cradle to gate and selected further life cycle stages); — a cradle to grave EPD: modules A to C mandatory. 3) EPDs for products to be used as in situ thermal insulation products including installation: — a cradle to gate EPD with options: modules A1, A2, A3 and A5 mandatory, the other modules optional (i.e. cradle to gate and selected further life cycle stages); — a cradle to grave EPD: modules A to C mandatory. 5.3 Comparability of EPD for construction products In principle, the comparison of products on the basis of their EPD is defined by the contribution they make to the environmental performance of the construction works. Consequently comparison of the environmental performance of construction products using the EPD information shall be based on the product’s use in and its impacts on the construction works, and shall consider the complete life cycle (all information modules). NOTE This is especially true for insulation products of which their main purpose is to reduce the energy consumption in the use stage of buildings. Since the reduction of the environmental impacts due to energy savings during the use stage is in most cases much higher than the environmental impacts of the insulation products themselves, it makes more sense to focus on good performance on building level during use than on comparing insulation products. End use applications are defined in Annex A. Cradle to grave analyses shall describe all relevant requirements for the end-use application of the product. 5.4 Additional information As in EN 15804 and additional Annex A of this European Standard. If benefits of insulation products due to energy saving during the installed life are reported in relation to the environmental performance of a building, they shall be reported as additional inf
...

Questions, Comments and Discussion