SIST EN 55016-2-3:2010/AC:2013
(Corrigendum)Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements
Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements
This part of CISPR 16 is designated a basic standard, which specified the methods of measurement of immunity to EMC phenomena in the frequency range 9 kHz to 18 GHz.
Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Teil 2-3: Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Messung der gestrahlten Störaussendung
Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques - Partie 2-3: Méthodes de mesure des perturbations et de l'immunité - Mesures des perturbations rayonnées
Specifikacija merilnih naprav in metod za merjenje radijskih motenj in odpornosti - 2-3. del: Metode za merjenje radijskih motenj in odpornosti - Merjenje sevanih motenj - Popravek AC
Ta del CISPR 16 je določen kot osnovni standard, ki opredeljuje metode za merjenje odpornosti na EMC fenomen v frekvenčnem razponu od 9 kHz do 18 GHz.
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Specifikacija merilnih naprav in metod za merjenje radijskih motenj in odpornosti - 2-3. del: Metode za merjenje radijskih motenj in odpornosti - Merjenje sevanih motenj - Popravek ACAnforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Teil 2-3: Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Messung der gestrahlten StöraussendungSpécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques - Partie 2-3: Méthodes de mesure des perturbations et de l'immunité - Mesures des perturbations rayonnéesSpecification for rad
...
Frequently Asked Questions
SIST EN 55016-2-3:2010/AC:2013 is a corrigendum published by the Slovenian Institute for Standardization (SIST). Its full title is "Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements". This standard covers: This part of CISPR 16 is designated a basic standard, which specified the methods of measurement of immunity to EMC phenomena in the frequency range 9 kHz to 18 GHz.
This part of CISPR 16 is designated a basic standard, which specified the methods of measurement of immunity to EMC phenomena in the frequency range 9 kHz to 18 GHz.
SIST EN 55016-2-3:2010/AC:2013 is classified under the following ICS (International Classification for Standards) categories: 17.240 - Radiation measurements; 33.100.20 - Immunity. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 55016-2-3:2010/AC:2013 has the following relationships with other standards: It is inter standard links to SIST EN 55016-2-3:2017, SIST EN 55016-2-3:2010. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
You can purchase SIST EN 55016-2-3:2010/AC:2013 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of SIST standards.
The article discusses the SIST EN 55016-2-3 standard, which is part of CISPR 16. It provides specifications for measuring radio disturbances and immunity to electromagnetic compatibility (EMC) phenomena. The standard focuses on measurements in the frequency range of 9 kHz to 18 GHz.
기사 제목: SIST EN 55016-2-3:2010/AC:2013 - 무선 장애 및 면역 측정 장비 및 방법 사양 - 파트 2-3: 장애 및 면역의 측정 방법 - 방사 장애 측정 기사 내용: 이 CISPR 16의 일부인 SIST EN 55016-2-3 표준은 9 kHz에서 18 GHz의 주파수 범위에서의 EMC 현상에 대한 면역 측정 방법을 명시한 기본 표준으로 지정되었습니다.
記事のタイトル:SIST EN 55016-2-3:2010/AC:2013 - 電波妨害および免疫性測定装置および方法の仕様 - 第2-3部: 電波放射妨害の測定方法 記事の内容:このCISPR 16の一部であるSIST EN 55016-2-3は、EMC現象に対する免疫性の測定方法を指定した基本規格です。9 kHzから18 GHzの周波数範囲での測定に焦点を当てています。







Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...