Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz -- Part 1: General requirements, frequency bands and electromagnetic disturbances

This standard applies to electrical equipment using signals in the frequency range 3 kHz to 148,5 kHz to transmit information on low voltage electrical systems, either on the public supply system or within installations in consumers' premises. It specifies the frequency bands allocated to the different applications, limits for the terminal output voltage in the operating band and limits for conducted and radiated disturbance. It also gives the methods of measurement. It does not specify the signal modulation methods nor the coding methods nor functional features (except those for the prevention of mutual interference) . Environmental requirements and tests are not included. Note: In most countries the transmission of information is subject to regulation. Compliance with this standard does not imply permission to establish communication with locations outside the consumer' s installation or with other consumers through the public supply system where this would not otherwise be allowed.

Signalübertragung auf elektrischen Niederspannungsnetzen im Frequenzbereich 3 kHz bis 148,5 kHz -- Teil 1: Allgemeine Anforderungen, Frequenzbänder und elektromagnetische Verträglichkeit

Transmission de signaux sur les réseaux électriques basse tension dans la bande de fréquences de 3 kHz à 148,5 kHz -- Partie 1: Règles générales, bandes de fréquences et perturbations électromagnétiques

Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz - Part 1: General requirements, frequency bands and electromagnetic disturbances

General Information

Status
Withdrawn
Publication Date
28-Feb-1997
Withdrawal Date
31-Jan-2003
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
01-Feb-2003
Due Date
01-Feb-2003
Completion Date
01-Feb-2003

Relations

Buy Standard

Standard
EN 50065-1:1997
English language
20 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz - Part 1: General requirements, frequency bands and electromagnetic disturbancesSignalübertragung auf elektrischen Niederspannungsnetzen im Frequenzbereich 3 kHz bis 148,5 kHz -- Teil 1: Allgemeine Anforderungen, Frequenzbänder und elektromagnetische VerträglichkeitTransmission de signaux sur les réseaux électriques basse tension dans la bande de fréquences de 3 kHz à 148,5 kHz -- Partie 1: Règles générales, bandes de fréquences et perturbations électromagnétiquesSignalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz -- Part 1: General requirements, frequency bands and electr
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.