SIST EN 3475-407:2009
(Main)Aerospace series - Cables, electrical, aircraft use - Test methods - Part 407: Flammability
- Abstract
This standard specifies two methods of determining the flammability characteristics of a finished cable.
It is intended to be used together with EN 3475-100.
- Status
- Published
- Publication Date
- 07-Sep-2009
- Technical Committee
- I13 - Imaginarni 13
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 24-Aug-2009
- Due Date
- 29-Oct-2009
- Completion Date
- 08-Sep-2009
SIST EN 3475-407:2009 is the Slovenian adoption of EN 3475-407:2009 for aerospace electrical cables. It specifies two methods for determining the flammability characteristics of a finished cable and is intended to be used together with EN 3475-100.
What does SIST EN 3475-407:2009 specify?
SIST EN 3475-407:2009 sets out a test-method standard for finished aerospace cables. Its job is to show how to prepare specimens, apply a flame, and judge whether the cable meets the flammability acceptance criteria.
The document is organized into these main clauses:
- Scope
- Normative references
- Equipment
- Procedures
- Acceptance criteria
| Clause / part | What it covers |
|---|---|
| Clause 3 | Test chamber and burner requirements |
| Clause 4.1 | Method 1 |
| Clause 4.2 | Method 2 |
| Clause 4.3 | How to complete and record the test |
| Clause 5 | Acceptance criteria |
What are the key requirements of SIST EN 3475-407:2009?
SIST EN 3475-407:2009 gives two different flame tests for a finished cable. Method 1 is the main cable-flammability test, while Method 2 checks flame behavior at the insulation-to-conductor junction. In practice, this lets a manufacturer or lab verify cable behavior under two different exposure conditions.
Test equipment and set-up
SIST EN 3475-407:2009 requires a test chamber of defined minimum size, open at the top and front, and a Bunsen type gas burner with specified geometry and gas capability. The chamber is placed in a draught-free environment, and the note warns that toxic fumes may be released, so the chamber should be in a fume cabinet. This matters because the test result depends on controlled airflow and flame shape.
Method 1 specimen preparation and flame application
SIST EN 3475-407:2009 Method 1 uses two sets of three specimens, each about 900 mm long, taken consecutively from the same coil. The specimens are conditioned at controlled temperature and humidity before testing. The cable is mounted at an angle, the flame is applied for 15 s to one set and 30 s to the other, and the flame is aimed at a defined point on the specimen. This gives a repeatable check of how the finished cable spreads flame along its length.
Method 2 specimen preparation and flame application
SIST EN 3475-407:2009 Method 2 uses three specimens about 450 mm long, also taken consecutively from the same coil and conditioned before testing. One end of the insulation is stripped back, the specimen is mounted vertically, and a 38 mm high soft yellow flame is applied at the junction of insulation and bare conductor for 15 s. This method focuses on ignition and propagation at the exposed conductor end, which is important for cables with stripped terminations.
Completion of the test and acceptance
SIST EN 3475-407:2009 requires the operator to record how long flaming continues after burner removal and the length of cable that burns. For both methods, no flaming droplets or particles are allowed to fall from the specimen during ignition and combustion. Method 1 also requires cessation of flaming within the time stated in the product standard and a total burnt length of 50 mm. Method 2 requires flaming to stop within 10 s and the burnt or charred length to stay within 75 mm. In practice, the product standard controls the Method 1 burn time limit.
What terms does SIST EN 3475-407:2009 use?
- Finished cable - a cable in its final manufactured form, ready for evaluation as a product.
- Flammability characteristics - the cable’s behavior when exposed to a flame, especially how it ignites and how far burning spreads.
- Specimen - the cut test piece taken from the cable coil for the flame test.
- Burnt length - the measured length of cable damaged by flame or charring after the burner is removed.
- Flaming droplets or particles - burning material that falls away from the specimen during the test, which is not permitted.
- Method 1 - the test route that applies flame to a mounted cable specimen at a defined angle and position.
- Method 2 - the test route that applies flame at the insulation-to-conductor junction on a vertically mounted specimen.
Who uses SIST EN 3475-407:2009?
SIST EN 3475-407:2009 is used by aerospace cable manufacturers, test laboratories, quality engineers, and certification or conformity assessment teams. Buyers and technical specifiers also use it when they need a common flammability test for aircraft-use electrical cables. It is relevant wherever cable flammability must be demonstrated against aerospace requirements.
What changed in SIST EN 3475-407:2009 from the previous edition?
SIST EN 3475-407:2009 supersedes EN 3475-407:2005.
Which standards are used with SIST EN 3475-407:2009?
- EN 3475-100 - the general test-method standard that this part is intended to be used with.
- FAR 25, Airworthiness standards - Transport category airplanes - referenced because Method 1 notes that the 30 s burn exposure is needed to assess FAR 25 requirements.
- JAR 25, Large aeroplanes - referenced alongside FAR 25 for the same reason.
What does the SIST EN 3475-407:2009 document contain?
SIST EN 3475-407:2009 contains the equipment description, specimen preparation steps, flame-setting instructions, mounting arrangements, flame application times, and post-test measurements needed to run the two methods. It also includes two figures showing the mounting configurations for the specimens. The document is written for test execution and acceptance, not for design calculation or product construction.
Relations
- Effective Date
- 01-Oct-2009
- Effective Date
- 28-Jan-2026
- Effective Date
- 09-Sep-2026
- Effective Date
- 09-Sep-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
Get Certified
Connect with accredited certification bodies for this standard

BUREAU VERITAS Certification Germany
Bureau Veritas certification in Germany.

Element Materials Technology
Materials testing and product certification.

AQMS Ltd.
AQMS provides ISO certification to SMEs across the UK.
Sponsored listings
Frequently Asked Questions
SIST EN 3475-407:2009 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Aerospace series - Cables, electrical, aircraft use - Test methods - Part 407: Flammability". This standard covers: This standard specifies two methods of determining the flammability characteristics of a finished cable. It is intended to be used together with EN 3475-100.
This standard specifies two methods of determining the flammability characteristics of a finished cable. It is intended to be used together with EN 3475-100.
SIST EN 3475-407:2009 is classified under the following ICS (International Classification for Standards) categories: 13.220.40 - Ignitability and burning behaviour of materials and products; 49.060 - Aerospace electric equipment and systems. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 3475-407:2009 has the following relationships with other standards: It is inter standard links to SIST EN 3475-407:2006, SIST EN 3475-100:2010, SIST EN 4604-009:2026, SIST EN 4604-010:2026, SIST EN 2267-009:2017, SIST EN 2713-007:2006, SIST EN 2714-013:2025, SIST EN 2713-012:2017, SIST EN 2713-012:2022, SIST EN 2714-014:2010, SIST EN 4612-004:2012, SIST EN 4612-002:2019, SIST EN 4612-010:2019, SIST EN 4604-007:2008, SIST EN 2714-006:2009. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN 3475-407:2009 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Luft- und Raumfahrt - Elektrische Leitungen für Luftfahrtverwendung - Prüfverfahren - Teil 407: EntflammbarkeitSérie aérospatiale - Câbles électriques à usage aéronautique - Méthodes d'essais - Partie 407: Tenue à la flammeAerospace series - Cables, electrical, aircraft use - Test methods - Part 407: Flammability49.060Aerospace electric equipment and systems13.220.40Sposobnost vžiga in obnašanje materialov in proizvodov pri gorenjuIgnitability and burning behaviour of materials and productsICS:Ta slovenski standard je istoveten z:EN 3475-407:2009SIST EN 3475-407:2009en01-oktober-2009SIST EN 3475-407:2009SLOVENSKI
STANDARDSIST EN 3475-407:20061DGRPHãþD
EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 3475-407August 2009ICS 13.220.40; 49.060Supersedes EN 3475-407:2005
English VersionAerospace series - Cables, electrical, aircraft use - Testmethods - Part 407: FlammabilitySérie aérospatiale - Câbles électriques à usageaéronautique - Méthodes d'essais - Partie 407 : Tenue à laflammeLuft- und Raumfahrt - Elektrische Leitungen fürLuftfahrtverwendung - Prüfverfahren - Teil 407:EntflammbarkeitThis European Standard was approved by CEN on 20 June 2009.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre:
Avenue Marnix 17,
B-1000 Brussels© 2009 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 3475-407:2009: ESIST EN 3475-407:2009
...



