SIST CLC/R 210-005:2000
(Main)Recommendations for shielded enclosures
Recommendations for shielded enclosures
CENELEC Report * D124/093: To be converted into TS
Recommendations for shielded enclosures
General Information
Relations
This May Also Interest You
This Technical Report applies to shielded enclosures used for EMC testing which are to be validated according to the EN 50147 series of standards and the corresponding international standards. The object of this report is to give guidance to the selection of the shielding materials and components. The frequency range for this document is 10 kHz to 40 GHz.
- Technical report16 pagesEnglish languagesale 10% offe-Library read for×1 day
This Technical Report applies to shielded enclosures used for EMC testing which are to be validated according to the EN 50147 series of standards and the corresponding international standards. The object of this report is to give guidance to the selection of the shielding materials and components. The frequency range for this document is 10 kHz to 40 GHz.
- Technical report16 pagesEnglish languagesale 10% offe-Library read for×1 day
This document gives guidance and requirements for the assessment of conformity of compounds, products, joints and assemblies in accordance with the applicable part(s) of the ISO 16486 series which are intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of certification procedures.
NOTE 1 A basic test matrix in Annex B provides an overview of the testing scheme.
It is recommended for the manufacturer to have a management system such as ISO 9001[4] or equivalent.
NOTE 2 If certification is involved, certification bodies and inspection bodies operating according to ISO/IEC 17065 and ISO/IEC 17020 are considered to be competent.
In conjunction with the other parts of the ISO 16486 series (see Clause 2), this document is applicable to unplasticized polyamide (PA-U) piping systems intended to be buried and used for the supply of gaseous fuels. It is applicable to PA-U pipes, fittings and valves, as well as to their joints and to joints with components of other materials intended to be used under the following conditions:
a) a maximum operating pressure (MOP) up to and including 18 bar[1] (the MOP is limited to 16 bar for CEN member countries, where ISO 16486-6 is replaced by CEN/TS 12007-6[1]);
b) an operating temperature of 20 °C as the reference temperature.
NOTE 3 For operating temperatures different to 20 °C, derating coefficients can be used (see ISO 16486-6). CEN member countries use CEN/TS 12007-6[1] and ISO/TS 16486-7 (this document) as a basis, but they can also request additional requirements. For non-CEN member countries, information for dealing with special cases for PA-U can be found in ISO/TS 16486-7 (this document) and PPI TR-3.[7]
For mechanical fittings conforming to ISO 17885, guidance for assessment of conformity is not given in this document. When requested, a quality plan based on the tests mentioned can be set up in agreement between user and manufacturer.
The ISO 16486 series covers a range of maximum operating pressures and gives requirements concerning colours.
NOTE 4 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
[1] 1 bar = 0,1 MPa = 105 Pa; 1 MPa = 1 N/mm2.
- Technical specification42 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft39 pagesEnglish languagesale 10% offe-Library read for×1 day
DEN/DECT-00359-2
- Standard76 pagesEnglish languagesale 10% offe-Library read for×1 day
- Standard76 pagesEnglish languagesale 15% off
- Standard76 pagesEnglish languagesale 15% off
- Draft76 pagesEnglish languagesale 10% offe-Library read for×1 day
- Amendment67 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft4 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies the external front and rear visibility conditions from cabs of tram
vehicles and the associated assessment method.
This document applies to vehicles operating on tram networks.
This document does not apply to driver's auxiliary desks.
This standard is not intended to be applied for tram train.
- Standard20 pagesEnglish languagesale 10% offe-Library read for×1 day
- Amendment19 pagesEnglish and French languagesale 10% offe-Library read for×1 day
- Draft2 pagesEnglish languagesale 10% offe-Library read for×1 day
- Standard3 pagesEnglish and French languagesale 15% off
- Amendment3 pagesEnglish languagesale 10% offe-Library read for×1 day
- Corrigendum4 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 60050-811:2017 gives the general terminology relating to electric traction used in electrical equipment and systems for railways, as well as general terms pertaining to specific applications and associated technologies. This new edition reviews and complements the previous one. This terminology is consistent with the terminology developed in the other specialized parts of the IEV.
It has the status of a horizontal standard in accordance with IEC Guide 108.
- Standard626 pagesEnglish and French languagesale 10% offe-Library read for×1 day
- Standard612 pagesEnglish and French languagesale 15% off
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.