SIST EN 62386-203:2009
(Main)Digital addressable lighting interface - Part 203: Particular requirements for control gears; discharge lamps (excluding fluorescent lamps) (device type 2) (IEC 62386-203:2009)
Digital addressable lighting interface - Part 203: Particular requirements for control gears; discharge lamps (excluding fluorescent lamps) (device type 2) (IEC 62386-203:2009)
IEC 62386-203:2009 specifies a protocol and test procedures for the control of electronic control gear by digital signals used on a.c. or d.c. supplies, associated with discharge lamps (excluding fluorescent lamps). This Part 203 is intended to be used in conjunction with IEC 62386-101 and IEC 62386-102, which contain general requirements for the relevant product type (control gear or control devices).
Digital adressierbare Schnittstelle für die Beleuchtung - Teil 203: Besondere Anforderungen an Betriebsgeräte - Entladungslampen (ausgenommen Leuchtstofflampen ) (Gerätetyp 2) (IEC 62386-203:2009)
Interface d'éclairage adressable numérique - Partie 203: Exigences particulières pour les appareillages; lampes à décharge (à l'exclusion des lampes fluorescentes) (dispositifs de type 2) (CEI 62386-203:2009)
La CEI 62386-203:2009 spécifie un protocole et des méthodes d'essai pour la commande des appareillages électroniques par des signaux numériques utilisés dans les alimentations alternatives ou continues, associés aux lampes à décharge (à l'exclusion des lampes fluorescentes). Cette Partie 203 est destinée à être utilisée conjointement avec la CEI 62386-101 et la CEI 62386-102, qui contiennent les exigences générales relatives au type de produit concerné (appareillage ou dispositifs de commande).
Digitalni naslovljivi vmesnik za razsvetljavo - 203. del: Posebne zahteve za krmilja - Sijalke (razen fluorescentnih sijalk) (naprava tipa 2) (IEC 62386-203:2009)
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 62386-203:2009
01-november-2009
Digitalni naslovljivi vmesnik za razsvetljavo - 203. del: Posebne zahteve za krmilja -
Sijalke (razen fluorescentnih sijalk) (naprava tipa 2) (IEC 62386-203:2009)
Digital addressable lighting interface - Part 203: Particular requirements for control gears;
discharge lamps (excluding fluorescent lamps) (device type 2) (IEC 62386-203:2009)
Digital adressierbare Schnittstelle für die Beleuchtung - Teil 203: Besondere
Anforderungen an Betriebsgeräte - Entladungslampen (ausgenommen
Leuchtstofflampen ) (Gerätetyp 2) (IEC 62386-203:2009)
Interface d'éclairage adressable numérique - Partie 203: Exigences particulières pour les
appareillages; lampes à décharge (à l'exclusion des lampes fluorescentes) (dispositifs de
type 2) (CEI 62386-203:2009)
Ta slovenski standard je istoveten z: EN 62386-203:2009
ICS:
29.140.30 )OXRUHVFHQþQHVLMDONH6LMDONH Fluorescent lamps.
Discharge lamps
29.140.50 Instalacijski sistemi za Lighting installation systems
razsvetljavo
35.200 Vmesniška in povezovalna Interface and interconnection
oprema equipment
SIST EN 62386-203:2009 en,fr
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 62386-203:2009
---------------------- Page: 2 ----------------------
SIST EN 62386-203:2009
EUROPEAN STANDARD
EN 62386-203
NORME EUROPÉENNE
August 2009
EUROPÄISCHE NORM
ICS 29.140.50; 29.140.99
English version
Digital addressable lighting interface -
Part 203: Particular requirements for control gear -
Discharge lamps (excluding fluorescent lamps)
(device type 2)
(IEC 62386-203:2009)
Interface d'éclairage Digital adressierbare Schnittstelle
adressable numérique - für die Beleuchtung -
Partie 203: Exigences particulières Teil 203: Besondere Anforderungen
pour les appareillages de commande - an Betriebsgeräte -
Lampes à décharge Entladungslampen
(à l'exclusion des lampes fluorescentes) (ausgenommen Leuchtstofflampen)
(dispositif de type 2) (Gerätetyp 2)
(CEI 62386-203:2009) (IEC 62386-203:2009)
This European Standard was approved by CENELEC on 2009-07-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: Avenue Marnix 17, B - 1000 Brussels
© 2009 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 62386-203:2009 E
---------------------- Page: 3 ----------------------
SIST EN 62386-203:2009
EN 62386-203:2009 - 2 -
Foreword
The text of document 34C/875/FDIS, future edition 1 of IEC 62386-203, prepared by SC 34C, Auxiliaries
for lamps, of IEC TC 34, Lamps and related equipment, was submitted to the IEC-CENELEC parallel vote
and was approved by CENELEC as EN 62386-203 on 2009-07-01.
This Part 203 is to be used in conjunction with EN 62386-101 and EN 62386-102, which contain general
requirements for the relevant product type (control gear or control devices).
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2010-04-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2012-07-01
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 62386-203:2009 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:
IEC 60598-1 NOTE Harmonized as EN 60598-1:2008 (modified).
IEC 60669-2-1 NOTE Harmonized as EN 60669-2-1:2004 (modified).
IEC 60921 NOTE Harmonized as EN 60921:2004 (not modified).
IEC 60923 NOTE Harmonized as EN 60923:2005 (not modified).
IEC 60925 NOTE Harmonized as EN 60925:1991 (not modified).
IEC 60929 NOTE Harmonized as EN 60929:2006 (not modified).
IEC 61347-1 NOTE Harmonized as EN 61347-1:2008 (modified).
IEC 61347-2-3 NOTE Harmonized as EN 61347-2-3:2001 (not modified).
IEC 61547 NOTE Harmonized as EN 61547:2009 (not modified).
IEC 62034 NOTE Harmonized as EN 62034:2006 (not modified).
CISPR 15 NOTE Harmonized as EN 55015:2006 (not modified).
__________
---------------------- Page: 4 ----------------------
SIST EN 62386-203:2009
- 3 - EN 62386-203:2009
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year
IEC 62386-101 2009 Digital addressable lighting interface - EN 62386-101 2009
Part 101: General requirements - System
IEC 62386-102 2009 Digital addressable lighting interface - EN 62386-102 2009
Part 102: General requirements - Control gear
---------------------- Page: 5 ----------------------
SIST EN 62386-203:2009
---------------------- Page: 6 ----------------------
SIST EN 62386-203:2009
IEC 62386-203
®
Edition 1.0 2009-06
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Digital addressable lighting interface –
Part 203: Particular requirements for control gear – Discharge lamps (excluding
fluorescent lamps) (device type 2)
Interface d’éclairage adressable numérique –
Partie 203: Exigences particulières pour les appareillages de commande –
Lampes à décharge (à l'exclusion des lampes fluorescentes) (dispositifs de
type 2)
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
U
CODE PRIX
ICS 29.140.50; 29.140.99 ISBN 2-8318-1040-3
® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale
---------------------- Page: 7 ----------------------
SIST EN 62386-203:2009
– 2 – 62386-203 © IEC:2009
CONTENTS
FOREWORD.3
INTRODUCTION.5
1 Scope.6
2 Normative references .6
3 Terms and definitions .6
4 General .7
5 Electrical specifications .7
6 Interface power supply .7
7 Transmission protocol structure.7
8 Timing .7
9 Method of operation .7
10 Declaration of variables .8
11 Definition of commands .9
12 Test procedures .13
Annex A (informative) Examples .25
Bibliography.26
Figure 1 – Example of the use of the "Arc Power At Requested Value" bit .8
Figure 2 – Application extended control or configuration command sequence example .9
Figure 3 – Test sequence “Physical selection supported”.14
Figure 4 – Test sequence 'START IDENTIFICATION' .15
Figure 5 – Test sequence 'MAINS VOLTAGE TOO LOW' .16
Figure 6 – Test sequence 'MAINS VOLTAGE TOO HIGH' .17
Figure 7 – 'LAMP VOLTAGE OUT OF SPECIFICATION' .18
Figure 8 – 'QUERY WAITING FOR IGNITION, IGNITION TIME OUT'.19
Figure 9 – 'QUERY CYCLING FAIL' .20
Figure 10 – 'QUERY THERMAL OVERLOAD'.21
Figure 11 – 'QUERY HID STATUS' .22
Figure 12 – 'QUERY EXTENDED VERSION NUMBER' .23
Figure 13 – 'RESERVED APPLICATION EXTENDED COMMANDS'.24
Table 1 - Declaration of additional variables .9
Table 2 – Summary of the application extended command set .13
---------------------- Page: 8 ----------------------
SIST EN 62386-203:2009
62386-203 © IEC:2009 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
DIGITAL ADDRESSABLE LIGHTING INTERFACE –
Part 203: Particular requirements for control gear –
Discharge lamps (excluding fluorescent lamps)
(device type 2)
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 62386-203 has been prepared by subcommittee 34C: Auxiliaries
for lamps, of IEC technical committee 34: Lamps and related equipment.
The text of this standard is based on the following documents:
FDIS Report on voting
34C/875/FDIS 34C/884/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
---------------------- Page: 9 ----------------------
SIST EN 62386-203:2009
– 4 – 62386-203 © IEC:2009
This Part 203 is intended to be used in conjunction with IEC 62386-101 and IEC 62386-102,
which contain general requirements for the relevant product type (control gear or control
devices).
A list of all parts of IEC 62386 series, under the general title Digital addressable lighting
interface, can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in
the data related to the specific publication. At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition; or
• amended.
---------------------- Page: 10 ----------------------
SIST EN 62386-203:2009
62386-203 © IEC:2009 – 5 –
INTRODUCTION
This first edition of IEC 62386-203 is published in conjunction with IEC 62386-101 and
IEC 62386-102. The division of IEC 62386 into separately published parts provides for ease
of future amendments and revisions. Additional requirements will be added as and when a
need for them is recognised.
This International Standard, and the other parts that make up the IEC 62386-200 series, in
referring to any of the clauses of IEC 62386-101 or IEC 62386-102, specify the extent to
which such a clause is applicable and the order in which the tests are to be performed. The
parts also include additional requirements, as necessary. All parts which make up the
IEC 62386-200 series are self-contained and therefore do not include references to each
other.
Where the requirements of any of the clauses of IEC 62386-101 or IEC 62386-102 are
referred to in this International Standard by the sentence "The requirements of IEC 62386-
1XX, clause ’n’ apply”, this sentence is to be interpreted as meaning that all requirements of
the clause in question of Part 101 or Part 102 apply, except any which are clearly inapplicable
to the specific type of lamp control gear covered by Part 203.
All numbers used in this International Standard are decimal numbers unless otherwise noted.
Hexadecimal numbers are given in the format 0xVV, where VV is the value. Binary numbers
are given in the format XXXXXXXXb or in the format XXXX XXXX, where X is 0 or 1; 'x' in
binary numbers means 'don't care'.
---------------------- Page: 11 ----------------------
SIST EN 62386-203:2009
– 6 – 62386-203 © IEC:2009
DIGITAL ADDRESSABLE LIGHTING INTERFACE –
Part 203: Particular requirements for control gear –
Discharge lamps (excluding fluorescent lamps)
(device type 2)
1 Scope
This International Standard specifies a protocol and test procedures for the control of
electronic control gear by digital signals used on a.c. or d.c. supplies, associated with
discharge lamps (excluding fluorescent lamps).
NOTE Tests in this standard are type tests. Requirements for testing individual control gear during production are
not included.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 62386-101:2009, Digital addressable lighting interface – Part 101: General requirements;
System
IEC 62386-102:2009, Digital addressable lighting interface – Part 102: General requirements
– Control gear
3 Terms and definitions
For the purposes of this document, the terms and definitions given in Clause 3 of IEC 62386-
101:2009 and Clause 3 of IEC 62386-102:2009 apply, with the following additional terms and
definitions.
3.1
lamp cycling
periodic igniting and extinguishing of the lamp
3.2
lamp failure
lamp parameter outside of the tolerances for the normal lamp operation
NOTE The number of attempts to ignite the lamp parameter before final switching off is control gear dependent.
3.3
run-up time
time which the system of control gear and lamp(s) needs to set the lamp output power to its
nominal lamp power value after switching on the lamp
3.4
waiting for ignition
control gear status with ignition function maximal up to the ignition time out without lamp
ignition
---------------------- Page: 12 ----------------------
SIST EN 62386-203:2009
62386-203 © IEC:2009 – 7 –
3.5
ignition time out
status of the control gear after an inefficient ignition time
NOTE The time is specified by the control gear manufacturer.
3.6
arc power at requested value
lamp(s) status with the requested arc power
4 General
The requirements of Clause 4 of IEC 62386-101:2009 and Clause 4 of IEC 62386-102:2009
apply.
5 Electrical specifications
The requirements of Clause 5 of IEC 62386-101:2009 and Clause 5 of IEC 62386-102:2009
apply.
6 Interface power supply
The requirements of Clause 6 of IEC 62386-101:2009 and Clause 6 of IEC 62386-102:2009
apply, if a power supply is integrated with the control gear.
7 Transmission protocol structure
The requirements of Clause 7 of IEC 62386-101:2009 and Clause 7 of IEC 62386-102:2009
apply.
8 Timing
The requirements of Clause 8 of IEC 62386-101:2009 and Clause 8 of IEC 62386-102:2009
apply.
9 Method of operation
The requirements of Clause 9 of IEC 62386-101:2009 and Clause 9 of IEC 62386-102:2009
apply with the following exceptions:
Addition to Clause 9 of IEC 62386-102:2009:
9.9 Arc power at requested value versus fade running
If a new arc power level is requested from a stable arc power level situation, the “Fade
Running” bit indicates fading from the stable arc power level to the newly requested power
level.
If the fading has been finished and the new arc power level has been reached the “Arc Power
At Requested Value” bit indicates whether the arc power is also at the desired value.
Figure 1 gives an example at given time point t:
---------------------- Page: 13 ----------------------
SIST EN 62386-203:2009
– 8 – 62386-203 © IEC:2009
250
200
180
0 1 2 3 4 5 6
IEC 626/09
t Arc power level Arc power level Fade running Arc power Arc power at
target (control gear) (control gear) (lamp) requested value
0 250 250 No 250 Yes
1 200 250 Yes 250 No
2 200 225 Yes 200 to 250 No
3 200 200 No 200 to 250 No
4 180 200 Yes 180 to 250 No
5 180 180 No 180 to 250 No
6 180 180 No 180 Yes
Figure 1 – Example of the use of the "Arc Power At Requested Value" bit
10 Declaration of variables
The requirements of Clause 10 of IEC 62386-102:2009 apply, with the following declaration of
additional variables, given in Table 1.
---------------------- Page: 14 ----------------------
SIST EN 62386-203:2009
62386-203 © IEC:2009 – 9 –
Table 1 - Declaration of additional variables
Default value
a
Memory
Variable Reset value Range of validity
(control gear leaves the
factory)
0 – 254,
'DEVICE TYPE' 2 no change 1 byte ROM
255 (MASK)
b
0000 0000
‘HID STATUS’ 0000 0000 0 – 255 1 byte RAM
‘ACTUAL HID b
0?00 0??? no change 0 – 255 1 byte RAM
FAILURE’
‘STORED HID b
0?00 0??? no change 0 – 255 1 byte RAM
FAILURE’
‘HID FEATURES’ factory burn-in no change 0 – 255 1 byte ROM
‘THERMAL
0 no change 0x0000 – 0xFFFF 2 bytes
OVERLOAD TIME’
b
'THEMAL LOAD' ???? ???? no change 0 – 255 1 byte RAM
'EXTENDED
VERSION 1 no change 0 – 255 1 byte ROM
NUMBER'
? = undefined
a
Persistent memory (storage time indefinite), if not stated otherwise.
b
Power up value
11 Definition of commands
The requirements of Clause 11 of IEC 62386-101:2009 and Clause 11 of IEC 62386-102:2009
apply, with the following exceptions:
Amendment of Clause 11 of IEC 62386-102:2009:
11.3.4 Application extended commands
Replacement:
11.3.4.1 General
Every control command (224) and configuration command (240) shall be received a second
time within 100 ms (nominal) before it is executed in order to reduce the probability of
incorrect reception. No other commands addressing the same control gear shall be sent
between these two commands, otherwise the first such command shall be ignored and the
respective control or configuration sequence shall be aborted.
Command 272 shall be received before the two instances of the application extended
configuration/control command, but not between them (see Figure 2).
Application extended Application extended
control/configuration control/configuration
Command 272
command command
max. 100ms
IEC 627/09
Figure 2 – Application extended control
or configuration command sequence example
---------------------- Page: 15 ----------------------
SIST EN 62386-203:2009
– 10 – 62386-203 © IEC:2009
All values of DTR shall be checked against the values mentioned in Clause 10, Range of
validity, i.e. the value shall be set to the upper / lower limit if it is above / below the valid
range defined in Table 1.
11.3.4.2 Application extended control commands
Command 224: YAAA AAA1 1110 0000 ‘RESET STORED HID FAILURE’
This command shall reset all failure bits defined in command 252 “QUERY STORED HID
FAILURE’.
Command 225: YAAA AAA1 1110 0001
Reserved for future needs. The control gear shall not react in any way.
Commands 226 - 227: YAAA AAA1 1110 001X
Reserved for future needs. The control gear shall not react in any way.
Commands 228 - 231: YAAA AAA1 1110 01XX
Reserved for future needs. The control gear shall not react in any way.
Command 232: YAAA AAA1 1110 1000
Reserved for future needs. The control gear shall not react in any way.
11.3.4.3 Application extended configuration commands
Commands 233: YAAA AAA1 1110 1001
Reserved for future needs. The control gear shall not react in any way.
Commands 234 - 235: YAAA AAA1 1110 101X
Reserved for future needs. The control gear shall not react in any way.
Commands 236 - 239: YAAA AAA1 1110 11XX
Reserved for future needs. The control gear shall not react in any way.
Command 240: YAAA AAA1 1111 0000 ‘START IDENTIFICATION’
The control gear shall start or restart a 10 s identification procedure. The details of this
procedure can only be defined by the manufacturer.
NOTE An appropriate procedure might be to change the arc power so as to facilitate identification of the control
gear by optical means.
11.3.4.4 Application extended query commands
Command 241: YAAA AAA1 1111 0001 ‘QUERY THERMAL LOAD’
Answer shall be the actual thermal load as an 8-bit number. The thermal load is a percentage
in the range from 0 % to 127,5 % with a 0,5 % resolution. A value of 255 means a
temperature load of 127,5 % or above.
This is an optional feature. If this feature is not implemented the control gear shall not react in
any way.
NOTE A value of 0 implies no thermal load, also equivalent to the load being at normal ambient temperature or
lower when switched off. A value of 100 % corresponds to control gear temperature consistent with achieving the
lifetime stated in the installation leaflet or manual. Tolerances can be specified only by the manufacturer.
Command 242: YAAA AAA1 1111 0010 ‘QUERY THERMAL OVERLOAD TIME HB’
Answer shall be the high byte (HHHH HHHHb) of the over-temperature time.
The low byte of the over-temperature time shall be transferred to DTR1.
---------------------- Page: 16 ----------------------
SIST EN 62386-203:2009
62386-203 © IEC:2009 – 11 –
This is an optional feature. If this feature is not implemented the control gear shall not react in
any way.
Command 243: YAAA AAA1 1111 0011 'QUERY THERMAL OVERLOAD TIME LB'
Answer shall be the low byte (LLLL LLLLb) of the over-temperature time.
This is an optional feature. If this feature is not implemented the control gear shall not react in
any way.
The combination of the two bytes (HHHHHHHHLLLLLLLLb) from command 242 and 243 shall
represent the 16-bit over-temperature time in units of 15 min. This is a cumulative value and
cannot be reset. If the 16-bit representation reaches the highest possible value of 65535
(0xFFFF) the over-temperature time is 16 383 h and 45 min or above. Over-temperature is
defined as: ‘thermal load of 100,5 % or above (see command 241).
Commands 244 - 247: YAAA AAA1 1111 01XX
Reserved for future needs. The control gear shall not react in any way.
Commands 248 - 249: YAAA AAA1 1111 100X
Reserved for future needs. The control gear shall not react in any way.
Command 250: YAAA AAA1 1111 1010 ‘QUERY HID FEATURES'
Answer shall be the following ‘HID FEATURES’ information byte about the optional features:
bit 0 ‘mains voltage too low’ can be queried ‘0’ = No
bit 1 ‘mains voltage too high’ can be queried ‘0’ = No
bit 2 ‘converter thermal load/overload time’ can be queried ‘0’ = No
bit 3 reserved ‘0’ = default value
bit 4 reserved ‘0’ = default value
bit 5 reserved ‘0’ = default value
bit 6 ‘lamp voltage out of specification’ can be queried ‘0’ = No
bit 7 physical selection supported ‘0’ = No
Command 251: YAAA AAA1 1111 1011 ‘QUERY ACTUAL HID FAILURE'
Answer shall be the following ‘ACTUAL HID FAILURE’ information byte:
bit 0 mains voltage too low ‘0’ = No
bit 1 mains voltage too high ‘0’ = No
bit 2 converter thermal overload ‘0’ = No
bit 3 reserved ‘0’ = default value
bit 4 ignition time out ‘0’ = No
bit 5 reserved ‘0’ = default value
bit 6 lamp voltage out of specification ‘0’ = No
bit 7 lamp cycling failure ‘0’ = No
The ‘ACTUAL HID FAILURE’ information shall be available in the RAM of the control gear.
Bits shall be set if the corresponding failure occurs and reset if the corresponding failure
disappears.
bit 4 “ignition timeout” shall be cleared on a successful ignition.
As long as bit 4 or bit 7 is set, the control gear shall also set bit 1 “lamp failure” in "STATUS
INFORMATION" and shall also reply “YES” to command 146 “QUERY LAMP FAILURE”.
Command 252: YAAA AAA1 1111 1100 ‘QUERY STORED HID FAILURE'
Answer shall be the following ‘STORED HID FAILURE’ information byte:
bit 0 mains voltage too low ‘0’ = No
bit 1 mains voltage too high ‘0’ = No
bit 2 converter thermal overload ‘0’ = No
bit 3 reserved ‘0’ = default value
bit 4 ignition time out ‘0’ = No
bit 5 reserved ‘0’ = default value
bit 6 lamp voltage out of specification ‘0’ = No
bit 7 lamp cycling failure ‘0’ = No
---------------------- Page: 17 ----------------------
SIST EN 62386-203:2009
– 12 – 62386-203 © IEC:2009
The ‘STORED HID FAILURE’ information shall be available in the RAM of the control gear.
Bits shall be set if the corresponding failure occurs. The bits shal
...