ISO 12625-5:2016 specifies a test method for the determination of the wet tensile strength of tissue paper and tissue products after soaking with water, using a tensile-strength-testing apparatus operating with a constant rate of elongation.
Currently, two types of tensile-strength-testing apparatus are commercially available, one where the test piece is positioned vertically and, for the other, horizontally. This document applies for both. For vertical tensile-strength-testing apparatus, a device which is held in the lower grip of the tensile-strength-testing apparatus, called a Finch Cup, is used to achieve the wetting. For horizontal tensile-strength-testing apparatus, the soaking device is placed between the clamps.
In cases where impurities and contraries have to be determined, ISO 15755[6] applies for these detections in tissue paper and tissue products.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a test method for the determination of the wet tensile strength of tissue paper and tissue products after soaking with water, using a tensile-strength-testing apparatus operating with a constant rate of elongation.
Currently, two types of tensile-strength-testing apparatus are commercially available, one where the test piece is positioned vertically and, for the other, horizontally. This document applies for both. For vertical tensile-strength-testing apparatus, a device that is held in the lower grip of the tensile-strength-testing apparatus, called a Finch Cup, is used to achieve the wetting. For horizontal tensile-strength-testing apparatus, the soaking device is placed between the two clamps.
This document is not applicable to cases where impurities and contraries are determined.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 12625-16:2015 specifies the testing procedures for the instrumental determination of the opacity of tissue paper or tissue products by diffuse reflectance using a paper backing.
ISO 12625-16:2015 contains specific instructions for the preparation of test pieces of single-ply and multi-ply products, where special preparation/procedures might be necessary.
It can be used to determine the opacity of tissue paper and tissue products containing fluorescent whitening agents, provided the UV content of the radiation incident on the test piece has been adjusted to conform to that in the CIE illuminant C using a fluorescent reference standard provided by an authorized laboratory as described in ISO 2470-1.
ISO 12625-16:2015 is not applicable to coloured tissue paper and tissue products which incorporate fluorescent dyes or pigments.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a test method for the determination of the wet tensile strength of tissue paper and tissue products after soaking with water, using a tensile-strength-testing apparatus operating with a constant rate of elongation. Currently, two types of tensile-strength-testing apparatus are commercially available, one where the test piece is positioned vertically and, for the other, horizontally. This document applies for both. For vertical tensile-strength-testing apparatus, a device that is held in the lower grip of the tensile-strength-testing apparatus, called a Finch Cup, is used to achieve the wetting. For horizontal tensile-strength-testing apparatus, the soaking device is placed between the two clamps. This document is not applicable to cases where impurities and contraries are determined.

  • Standard
    15 pages
    English language
    sale 15% off
  • Standard
    16 pages
    French language
    sale 15% off

This document specifies the testing procedures for the instrumental determination of the opacity of tissue paper or tissue products by diffuse reflectance using a paper backing.
This document contains specific instructions for the preparation of test pieces of single-ply and multi-ply products, where special preparation/procedures might be necessary.
It can be used to determine the opacity of tissue paper and tissue products containing fluorescent whitening agents, provided the UV content of the radiation incident on the test piece has been adjusted to conform to that in the CIE illuminant C using a fluorescent reference standard provided by an authorized laboratory as described in ISO 2470-1.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the testing procedures for the instrumental determination of the opacity of tissue paper or tissue products by diffuse reflectance using a paper backing. This document contains specific instructions for the preparation of test pieces of single-ply and multi-ply products, where special preparation/procedures might be necessary. It can be used to determine the opacity of tissue paper and tissue products containing fluorescent whitening agents, provided the UV content of the radiation incident on the test piece has been adjusted to conform to that in the CIE illuminant C using a fluorescent reference standard provided by an authorized laboratory as described in ISO 2470-1.

  • Standard
    12 pages
    English language
    sale 15% off
  • Standard
    12 pages
    French language
    sale 15% off

ISO 12625-12:2010 specifies a test method for the determination of the tensile strength of perforated lines of tissue paper. It uses a tensile-testing apparatus operating with a constant rate of elongation.
This method is only used for measuring machine-direction tensile strength, that is for cross-direction perforations on tissue paper.
The calculation of perforation efficiency is also specified in ISO 12625-12:2010.

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a test method for the determination of the tensile strength of perforated lines of tissue paper. It uses a tensile-testing apparatus operating with a constant rate of elongation.
This method is only used for measuring machine-direction tensile strength, that is for cross-direction perforations on tissue paper.
The calculation of perforation efficiency is also specified in this document.

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a test method for the determination of the tensile strength of perforated lines of tissue paper. It uses a tensile-testing apparatus operating with a constant rate of elongation. This method is only used for measuring machine-direction tensile strength, that is for cross-direction perforations on tissue paper. The calculation of perforation efficiency is also specified in this document.

  • Standard
    15 pages
    English language
    sale 15% off
  • Standard
    15 pages
    French language
    sale 15% off

This document specifies testing procedures for the instrumental determination of brightness and
colour of tissue paper and tissue products viewed in indoor daylight conditions. It also gives specific
instructions for the preparation of test pieces (single-ply, multi-ply products) and for the optical
measurements of products, where special precautions can be necessary.
NOTE The properties called D65 brightness and colour are measured with an instrument adjusted to a much
higher UV content than that specified in this document.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a test method for the determination of the surface friction of tissue paper and tissue products using a contact-type surface tester.

  • Standard
    11 pages
    English language
    sale 15% off

This document specifies testing procedures for the instrumental determination of brightness and colour of tissue paper and tissue products viewed in indoor daylight conditions. It also gives specific instructions for the preparation of test pieces (single-ply, multi-ply products) and for the optical measurements of products, where special precautions can be necessary.
NOTE      The properties called D65 brightness and colour are measured with an instrument adjusted to a much higher UV content than that specified in this document.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a test method for the determination of the tensile strength, stretch at
maximum force and tensile energy absorption of tissue paper and tissue products. It uses a tensiletesting apparatus operating with a constant rate of elongation.
It also specifies the method of calculating the tensile index and the tensile energy absorption index.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies testing procedures for the instrumental determination of brightness and colour of tissue paper and tissue products viewed in indoor daylight conditions. It also gives specific instructions for the preparation of test pieces (single-ply, multi-ply products) and for the optical measurements of products, where special precautions can be necessary. NOTE The properties called D65 brightness and colour are measured with an instrument adjusted to a much higher UV content than that specified in this document.

  • Standard
    10 pages
    English language
    sale 15% off
  • Standard
    12 pages
    French language
    sale 15% off

This document specifies a test method for the determination of the tensile strength, stretch at maximum force and tensile energy absorption of tissue paper and tissue products. It uses a tensile-testing apparatus operating with a constant rate of elongation.
It also specifies the method of calculating the tensile index and the tensile energy absorption index.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a test method for the determination of the tensile strength, stretch at maximum force and tensile energy absorption of tissue paper and tissue products. It uses a tensile-testing apparatus operating with a constant rate of elongation. It also specifies the method of calculating the tensile index and the tensile energy absorption index.

  • Standard
    12 pages
    English language
    sale 15% off
  • Standard
    12 pages
    French language
    sale 15% off

This document specifies testing procedures for the instrumental determination of brightness and colour of tissue paper and tissue products viewed under outdoor daylight conditions. It also gives specific instructions for the preparation of test pieces (single-ply, multi-ply products) and for the optical measurements of products, where special precautions can be necessary.
NOTE       The properties called ISO brightness and colour with C/2° (indoor daylight) are measured with an instrument adjusted to a much lower UV content than that specified in this document. The measurements of ISO brightness and colour with C/2° (indoor daylight) are described in ISO 12625-15.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a method to assess the disintegration of tissue paper and tissue products when subjected to mechanical agitation in water.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies testing procedures for the instrumental determination of brightness and
colour of tissue paper and tissue products viewed under outdoor daylight conditions. It also gives
specific instructions for the preparation of test pieces (single-ply, multi-ply products) and for the optical
measurements of products, where special precautions can be necessary.
NOTE The properties called ISO brightness and colour with C/2° (indoor daylight) are measured with an
instrument adjusted to a much lower UV content than that specified in this document. The measurements of ISO
brightness and colour with C/2° (indoor daylight) are described in ISO 12625-15.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies testing procedures for the instrumental determination of brightness and colour of tissue paper and tissue products viewed under outdoor daylight conditions. It also gives specific instructions for the preparation of test pieces (single-ply, multi-ply products) and for the optical measurements of products, where special precautions can be necessary. NOTE The properties called ISO brightness and colour with C/2° (indoor daylight) are measured with an instrument adjusted to a much lower UV content than that specified in this document. The measurements of ISO brightness and colour with C/2° (indoor daylight) are described in ISO 12625-15.

  • Standard
    12 pages
    English language
    sale 15% off
  • Standard
    12 pages
    English language
    sale 15% off
  • Standard
    12 pages
    French language
    sale 15% off
  • Standard
    12 pages
    French language
    sale 15% off

The aim of the present standard is to determine the time necessary to disintegrate a test piece of toilet
paper, in specified conditions.
This test method is applicable to every type of toilet paper, with exception to papers used in toilets with
a specific way of paper removal [for example watertight chemical toilets in some means of transport:
see NF F 31-829 (French standard)].
Removal problems encountered in this latter case may then justify a greater degree of resistance of
the product and thus a very long disintegration time, or even no disintegration at all.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a method to assess the disintegration of tissue paper and tissue products when subjected to mechanical agitation in water.

  • Standard
    14 pages
    English language
    sale 15% off
  • Standard
    14 pages
    English language
    sale 15% off
  • Standard
    14 pages
    French language
    sale 15% off
  • Standard
    14 pages
    French language
    sale 15% off

This document specifies a test method for the determination of the resistance to mechanical penetration (ball burst strength procedure) of tissue paper and tissue products after wetting.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document establishes general principles for the use of terms in the entire working field of tissue paper and tissue products.
It permits the use of a common terminology in industry and commerce.
It is expressly stated that ISO 15755 applies for the detection of impurities and contraries in tissue paper and tissue products.
For the determination of moisture content in tissue paper and tissue products, ISO 287 applies.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a test method for the determination of the resistance to mechanical penetration
(ball burst strength procedure) of tissue paper and tissue products after wetting.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document establishes general principles for the use of terms in the entire working field of tissue
paper and tissue products.
It permits the use of a common terminology in industry and commerce.
It is expressly stated that ISO 15755 applies for the detection of impurities and contraries in tissue
paper and tissue products.
For the determination of moisture content in tissue paper and tissue products, ISO 287 applies.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a test method for the determination of the resistance to mechanical penetration (ball burst strength procedure) of tissue paper and tissue products after wetting.

  • Standard
    9 pages
    English language
    sale 15% off
  • Standard
    9 pages
    English language
    sale 15% off
  • Standard
    10 pages
    French language
    sale 15% off
  • Standard
    10 pages
    French language
    sale 15% off

This document establishes general principles for the use of terms in the entire working field of tissue paper and tissue products. It permits the use of a common terminology in industry and commerce. It is expressly stated that ISO 15755 applies for the detection of impurities and contraries in tissue paper and tissue products. For the determination of moisture content in tissue paper and tissue products, ISO 287 applies.

  • Standard
    18 pages
    English language
    sale 15% off
  • Standard
    18 pages
    English language
    sale 15% off
  • Standard
    20 pages
    French language
    sale 15% off
  • Standard
    20 pages
    French language
    sale 15% off

ISO 12625-6:2016 specifies a test method for the determination of grammage of tissue paper and tissue products.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a test method for the determination of grammage of tissue paper and tissue
products.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 12625-6:2016 specifies a test method for the determination of grammage of tissue paper and tissue products.

  • Standard
    10 pages
    English language
    sale 15% off
  • Standard
    10 pages
    French language
    sale 15% off

ISO 12625-9:2015 specifies a test method for the determination of the resistance to mechanical penetration (ball burst strength procedure) of tissue paper and tissue products.
Currently, two types of clamping devices are available on the market with two different diameters, one is with 50 mm and one is with 89 mm. ISO 12625-9:2015 applies for a 50 mm clamping device to be able to measure all sample sizes of tissue paper and tissue products and to be consistent with ISO 12625-11.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of 12625 specifies a test method for the determination of the resistance to mechanical penetration (ball burst
strength procedure) or tissue paper and tissue products.
It is expressly stated that the detection of impurities and contraries in tissue paper and tissue products should be applied according
to ISO 15755.
For the determination of moisture content in tissue paper and tissue products, ISO 287 should be applied.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 12625-9:2015 specifies a test method for the determination of the resistance to mechanical penetration (ball burst strength procedure) of tissue paper and tissue products. Currently, two types of clamping devices are available on the market with two different diameters, one is with 50 mm and one is with 89 mm. ISO 12625-9:2015 applies for a 50 mm clamping device to be able to measure all sample sizes of tissue paper and tissue products and to be consistent with ISO 12625-11.

  • Standard
    10 pages
    English language
    sale 15% off
  • Standard
    11 pages
    French language
    sale 15% off

ISO 12625-3:2014 specifies a test method for the determination of thickness and bulking thickness and the calculation of apparent bulk density and bulk of tissue papers and tissue products under a pressure of 2,0 kPa.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN ISO 12625 specifies a test method for the determination of thickness, bulking thickness and the calculation of apparent bulk density and bulk of tissue papers and tissue products under a pressure of 2,0 kPa.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 12625-3:2014 specifies a test method for the determination of thickness and bulking thickness and the calculation of apparent bulk density and bulk of tissue papers and tissue products under a pressure of 2,0 kPa.

  • Standard
    11 pages
    English language
    sale 15% off
  • Standard
    11 pages
    English language
    sale 15% off
  • Standard
    11 pages
    French language
    sale 15% off
  • Standard
    11 pages
    French language
    sale 15% off

ISO 12625-8:2010 specifies a basket-immersion test method for the determination of water-absorption time and water-absorption capacity of tissue paper and tissue products.
It is expressly stated that the detection of impurities and contraries in tissue paper and tissue products be applied according to ISO 15755.
For the determination of moisture content in tissue paper and tissue products, ISO 287 is applicable.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of ISO 12625 specifies a basket-immersion test method for the determination of water-absorption time and water-absorption capacity of tissue paper and tissue products. It is expressly stated that the detection of impurities and contraries in tissue paper and tissue products be applied according to ISO 15755. For the determination of moisture content in tissue paper and tissue products, ISO 287 is applicable.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 12625-8:2010 specifies a basket-immersion test method for the determination of water-absorption time and water-absorption capacity of tissue paper and tissue products. It is expressly stated that the detection of impurities and contraries in tissue paper and tissue products be applied according to ISO 15755. For the determination of moisture content in tissue paper and tissue products, ISO 287 is applicable.

  • Standard
    7 pages
    English language
    sale 15% off
  • Standard
    7 pages
    French language
    sale 15% off

This document specifies a test method for the determination of the wet tensile strength of tissue paper
and tissue products after soaking with water, using a tensile-strength-testing apparatus operating with
a constant rate of elongation.
Currently, two types of tensile-strength-testing apparatus are commercially available, one where
the test piece is positioned vertically and, for the other, horizontally. This document applies for both.
For vertical tensile-strength-testing apparatus, a device which is held in the lower grip of the tensilestrength-
testing apparatus, called a Finch Cup, is used to achieve the wetting. For horizontal tensilestrength-
testing apparatus, the soaking device is placed between the clamps.
In cases where impurities and contraries have to be determined, ISO 15755[6] applies for these
detections in tissue paper and tissue products.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of ISO 12625 specifies testing procedures for the instrumental determination of opacity paper backing of
tissue paper and tissue products by diffuse reflectance.
This part of ISO 12625 also gives specific instructions for the preparation of test pieces (single-ply, multi-ply products),
where special precautions may be necessary.
It can be used to determine the opacity of tissue paper and tissue products which contain fluorescent whitening agents,
provided the UV content of the radiation incident on the test piece has been adjusted to conform to that in the CIE
illuminant C using a fluorescent reference standard provided by an ISO/TC 6 authorized laboratory as described in ISO 2470-1.
This International Standard is not applicable to coloured tissue paper and tissue products which incorporate fluorescent
dyes or pigments.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 12625-5:2016 specifies a test method for the determination of the wet tensile strength of tissue paper and tissue products after soaking with water, using a tensile-strength-testing apparatus operating with a constant rate of elongation.
Currently, two types of tensile-strength-testing apparatus are commercially available, one where the test piece is positioned vertically and, for the other, horizontally. This document applies for both. For vertical tensile-strength-testing apparatus, a device which is held in the lower grip of the tensile-strength-testing apparatus, called a Finch Cup, is used to achieve the wetting. For horizontal tensile-strength-testing apparatus, the soaking device is placed between the clamps.
In cases where impurities and contraries have to be determined, ISO 15755[6] applies for these detections in tissue paper and tissue products.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 12625-16:2015 specifies the testing procedures for the instrumental determination of the opacity of tissue paper or tissue products by diffuse reflectance using a paper backing.
ISO 12625-16:2015 contains specific instructions for the preparation of test pieces of single-ply and multi-ply products, where special preparation/procedures might be necessary.
It can be used to determine the opacity of tissue paper and tissue products containing fluorescent whitening agents, provided the UV content of the radiation incident on the test piece has been adjusted to conform to that in the CIE illuminant C using a fluorescent reference standard provided by an authorized laboratory as described in ISO 2470-1.
ISO 12625-16:2015 is not applicable to coloured tissue paper and tissue products which incorporate fluorescent dyes or pigments.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of ISO 12625 specifies a test method for the determination of the tensile strength of perforated lines of tissue paper. It uses a tensile-testing apparatus operating with a constant rate of elongation. This method is only used for measuring machine-direction tensile strength, that is for cross-direction perforations on tissue paper. The calculation of perforation efficiency is also specified in this part of ISO 12625. It is expressly stated that the detection of impurities and contraries in tissue paper and tissue products can be carried out according to ISO 15755. For the determination of moisture content in tissue paper and tissue products, ISO 287 can be applied.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 12625-12:2010 specifies a test method for the determination of the tensile strength of perforated lines of tissue paper. It uses a tensile-testing apparatus operating with a constant rate of elongation.
This method is only used for measuring machine-direction tensile strength, that is for cross-direction perforations on tissue paper.
The calculation of perforation efficiency is also specified in ISO 12625-12:2010.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of ISO 12625 specifies testing procedures for the instrumental determination of brightness and colour of tissue paper and tissue products viewed in indoor daylight conditions. It also gives specific instructions for the preparation of test pieces (single-ply, multi-ply products) and for the optical measurements of products, where special precautions may be necessary.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 12625-15:2015 specifies testing procedures for the instrumental determination of brightness and colour of tissue paper and tissue products viewed in indoor daylight conditions. It also gives specific instructions for the preparation of test pieces (single-ply, multi-ply products) and for the optical measurements of products, where special precautions may be necessary.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a test method for the determination of the tensile strength, stretch at
maximum force and tensile energy absorption of tissue paper and tissue products. It uses a tensiletesting
apparatus operating with a constant rate of elongation.
It also specifies the method of calculating the tensile index and the tensile energy absorption index.
In cases where impurities and contraries have to be determined, ISO 15755[6] applies for these
detections in tissue paper and tissue products.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 12625-4:2016 specifies a test method for the determination of the tensile strength, stretch at maximum force and tensile energy absorption of tissue paper and tissue products. It uses a tensile-testing apparatus operating with a constant rate of elongation.
It also specifies the method of calculating the tensile index and the tensile energy absorption index.
In cases where impurities and contraries have to be determined, ISO 15755[6] applies for these detections in tissue paper and tissue products.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day